• 제목/요약/키워드: Modes of Operation

검색결과 812건 처리시간 0.026초

Analysis of an Active Superconducting Current Controller (ASCC) Considering the Transient Stability and OCR Operation in Transmission and Distribution Systems

  • Gusheh, Ahmad Ghafari;Soreshjani, Mohsen Hosseinzadeh;Rahat, Omid
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.543-550
    • /
    • 2016
  • The Active Superconducting Current Controller (ASCC) is a new type of Superconducting Fault Current Limiters (SFCL) which can limit the fault current in different modes. It also has the particular abilities of compensating active and reactive powers for electrical networks. In this paper, it is confirmed that the performance of ASCC in different operating modes introduces a limiting impedance in series with the network which can even degrade the transient stability and the operation of the Over-Current Relays (OCR) employed in a power system. In addition, the model of a three-phase ASCC is simulated, and the effect of descriptive modes on the current limiting level is investigated. For the transient stability analysis, a single machine-infinite bus system is tested, and the effect of operation modes is studied based on an equal area criterion obtaining the critical time and the critical angle. Modifying the setting parameters of OCR such as time dial and pick-up current, the protective coordination is also studied in different operating modes.

전투함 하이브리드 전기추진 시스템의 PTO 운전모드 적용 및 연료절감 효과 연구 (A Study on the Adoption of Power Take Off Operation Mode and Fuel-Saving Effect in the Hybrid Electric Propulsion System for a Warship)

  • 김소연
    • 전력전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.40-48
    • /
    • 2019
  • Hybrid electric propulsion systems (H-EPSs) are an intermediate step for integrated full electric propulsion warships. H-EPSs are a dynamic combination of mechanical and electrical propulsion systems to achieve the required mission performances. The system modes could adapt to meet the requirement of the various operation conditions of a warship. This paper presents a configuration and operating modes of H-EPSs considering the operation conditions of a destroyer class warship. The system has three propulsion modes, namely, motoring mode, generating mode [power take off (PTO) mode], and mechanical mode. The PTO mode requires a careful fuel efficiency analysis because the fuel consumption rate of propulsion engines may be low compared with the generator's engines depending on the loading power. Therefore, the calculation of fuel consumption according to the operating modes is performed in this study. Although the economics of the PTO mode depends on system cases, it has an advantage in that it ensures the reliability of electric power in case of blackout or minimum generator operation.

블록 암호 연산 모드 RBF(Random Block Feedback)의 알려진/선택 평문 공격에 대한 안전성 비교 분석 (Safety Comparison Analysis Against Known/Chosen Plaintext Attack of RBF (Random Block Feedback) Mode to Other Block Cipher Modes of Operation)

  • 김윤정;이강
    • 한국통신학회논문지
    • /
    • 제39B권5호
    • /
    • pp.317-322
    • /
    • 2014
  • 데이타 보안과 무결성은 유무선 통신 환경에서 데이터 전송 시에 중요한 요소이다. 대량의 데이터는 전송 전에, 통상 암호 연산 모드를 이용한 블록 암호 알고리즘에 의하여 암호화된다. ECB, CBC 등의 기존 연산 모드 외에 블록 암호 연산 모드로 RBF 모드가 제안된 바 있다. 본 논문에서는, 알려진 평문 공격 (known plaintext attack) 및 선택 평문 공격 (chosen plaintext attack)에 대한, RBF 모드의 안전성을 기존 모드들과 비교 분석한 내용을 소개한다. 분석 결과, 기존의 연산 모드들이 알려진/선택 평문 공격에 취약한데 반하여, RBF 모드는 이들 공격에 안전함을 알 수 있었다.

데이터 기반 이상진단법을 위한 화학공정의 조업모드 판별 (Operation Modes Classification of Chemical Processes for History Data-Based Fault Diagnosis Methods)

  • 이창준;고재욱;이기백
    • Korean Chemical Engineering Research
    • /
    • 제46권2호
    • /
    • pp.383-388
    • /
    • 2008
  • 화학공정의 안전하고 효율적인 운전에 관심이 커지면서 공정이상의 원인을 조기에 진단하기 위한 다양한 이상진단방법이 연구되어 왔다. 최근에는 통계적 모델 등 정량적 데이터에 기반한 이상진단방법이 많이 연구되고 있으나, 특정 조업영역에서 얻어진 통계적 모델을 다른 조업영역에 적용하면 오진단이 많아지게 된다. 따라서 공정특성상 다양한 조업영역이 존재하는 화학공정에 데이터기반 방법론을 적용하기에는 어려움이 있어 화학공정의 조업영역 판별법이 요구되고 있다. 이 연구에서는 유클리드 거리(Euclidean distance), FDA(Fisher's discriminant analysis), PCA(principal component analysis)의 통계모델과 이 모델들에 공정변수의 동특성을 반영한 모델을 제안하였다. 6개의 조업모드를 가진 TE(tennessee eastman) 공정에 대한 사례연구를 통해 동특성을 반영한 PCA 모델의 성능이 가장 우수함을 확인하였다.

녹색 신교통 시스템 바이모달트램의 수송수요 및 운행속도별 운영비용 분포특성 분석 (The Analysis of Distribution Characteristic on the Operation Cost for Respective Transport Volume and Travel Speed of New Transit System Bi-Modal Tram)

  • 배을호;김경만;신철호;김도한;박영곤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.2297-2302
    • /
    • 2010
  • The status and effectiveness of Bi-modal Tram is analyzed through the comparison of the transport effectiveness and operation cost between the public transportation systems (bus, light rail transit) considering the vehicle and operation characteristic of new transit system Bi-modal Tram. The standard operation schedule is established in consideration of the vehicle specification and operation characteristic of main public transportation modes, and then the annual average operation cost is estimated depending on the volume, speed, analysis length for respective public transportation mode. Through analyzing the operation cost and distribution characteristic of public transportation modes depending on the transport volume and travel speed, the operational efficiency suitable for the city is derived. It is concluded that the operational efficiency of Bi-modal Tram is superior to that of the bus and light rail transit on the aspect of travel volume and operation speed.

  • PDF

Master-Slave 기법을 적용한 System Operation의 동작 검증 (Verification of System using Master-Slave Structure)

  • 김인수;민형복
    • 전기학회논문지
    • /
    • 제58권1호
    • /
    • pp.199-202
    • /
    • 2009
  • Scan design is currently the most widely used structured Design For Testability approach. In scan design, all storage elements are replaced with scan cells, which are then configured as one or more shift registers(also called scan chains) during the shift operation. As a result, all inputs to the combinational logic, including those driven by scan cells, can be controlled and all outputs from the combinational logic, including those driving scan cells, can be observed. The scan inserted design, called scan design, is operated in three modes: normal mode, shift mode, and capture mode. Circuit operations with associated clock cycles conducted in these three modes are referred to as normal operation, shift operation, and capture operation, respectively. In spite of these, scan design methodology has defects. They are power dissipation problem and test time during test application. We propose a new methodology about scan shift clock operation and present low power scan design and short test time.

직류형 마이크로그리드의 전운전영역을 고려한 협조제어 (The Coordination Control of DC Microgrid on the Whole Operation Range)

  • 최대희;주수진;민용
    • 전기학회논문지
    • /
    • 제64권6호
    • /
    • pp.864-871
    • /
    • 2015
  • Recently, one of the main research on the power distribution system is the microgrid. The microgrid is a combination of power sources and loads, which is controllable and has separable connection. The main objective of microgrid is the deployment of the renewable clean energy and the enhancement of load-side reliability. The modern power sources and loads have DC I/O interfaces, which is the major advantage of DC microgrid compared to the conventional AC grid. The components in the microgrid have diverse features, so there is need of proper coordination control. For achieving economic feature, the active power of renewable energy resources is regarded as major control parameter and the whole operation modes of DC microgrid are defined, and the proper operations of each component are described. From the inherent characteristics of DC, there are two control variables: voltage and active power. Through analysis of operation modes, it is possible to determine exact control objectives and optimized voltage & power control strategy in each mode. Because of consideration of whole operation modes, regardless of the number and capacity of components, this coordination control method can be used without modification. This paper defines operation mode of DC microgrid with several DC sources and suggests economic and efficient coordinated control methods. Simulation with PSCAD proves effectiveness.

Analysis of MOSFET Failure Modes in Bi-directional Phase-Shift Full-Bridge Converters

  • Oh, Chang-Yeol;Sung, Won-Yong;Kim, Yun-Sung;Lee, Byoung-Kuk
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1692-1699
    • /
    • 2015
  • This paper presents an analysis of the mechanism of failure modes in bi-directional phase-shift full-bridge converters, composed of MOSFET, based on the circuit operation and parasitic parameters of MOSFET. In addition, the relation between circuit operation and parameters is suggested through an experimental comparison. From this relation, the suitable ranges of parameters for stable performance are analyzed. The design criteria of the bi-directional phase-shift full-bridge converter are presented and evaluated from the experimental verification.

Compound-Type Hybrid Energy Storage System and Its Mode Control Strategy for Electric Vehicles

  • Wang, Bin;Xu, Jun;Cao, Binggang;Li, Qiyu;Yang, Qingxia
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.849-859
    • /
    • 2015
  • This paper proposes a novel compound-type hybrid energy storage system (HESS) that inherits the unique advantages of both battery/supercapacitor (SC) and the SC/battery HESSs for electric vehicles (EVs). Eight operation modes are designed to match this system. A mode control strategy is developed for this HESS on the basis of these modes, and five classes of operation modes are established to simplify this strategy. The mode control strategy focuses on high operating efficiency and high power output. Furthermore, the compound-type HESS is designed such that the SC is the main priority in braking energy absorption. Thus, this HESS can operate efficiently and extend battery life. Simulation results also show that the compound-type HESS can not only supply adequate power to the motor inverter but can also determine suitable operation modes in corresponding conditions. Experimental results demonstrate that this HESS can extend battery life as well. The overall efficiency of the compound-type HESS is higher than those of the battery/SC and the SC/battery HESSs.

기상요인 변화에 따른 고객의 교통수단 이용행태 분석 (The analysis of customers patterns selecting transportation modes in accordance with weather change)

  • 박은경
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.746-755
    • /
    • 2009
  • This study will analyze the data of Kyongbu & Honam Line whether how much the weather change has an effect on the change of transportation modes and check the pattern of customer's behavior and investigate the influence on the changing transportation modes. Especially, this study will confine to the rainfall and snowfall out of various weather causes, and the questionnaire investigation is used to know the sensitivity of customer's patterns selecting transportation modes in accordance with weather change, and the research result will be used to make a marketing strategy & efficient train operation.

  • PDF