• Title/Summary/Keyword: Model furnace

Search Result 322, Processing Time 0.023 seconds

The research on CFD turbulance models for comparison according to my secondary air injection into the combustion (연소로 내 2차 공기 분사에 따른 CFD 난류 모델 비교에 관한 연구)

  • Choi, Junhyuk;Choi, Chong-gun;Hwang, Seung-Sik;Shin, Donghoon;Chung, Tae-Yong
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.345-347
    • /
    • 2012
  • The secondary air injection influences the flow of the combustion gas in the furnace. Therefore, the analysis of the furnace should be careful in the selection of the turbulent model with CFD. In this study, CFD results of several turbulent models were compared with experimental results. Analysis results suggest to select turbulent models in the furnace secondary air nozzle.

  • PDF

Development of a Mixed Chaotic Electric Arc Furnace Model (전력 품질 해석을 위한 개선된 전기아크로 모델 개발)

  • Jang, Gil-Soo;Wang, Weiguo;Lee, Byongjun;Kwon, Sae-Hyuk
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.2
    • /
    • pp.90-95
    • /
    • 2001
  • Electric arc furnaces (EAFs) has a process to cause the degradation of the electric power quality such as voltage flicker. In order to adequately understand and analyze the effects on the power system from these loads, obtaining an accurate representation of the characteristics of the loads is crucial. In this paper, a mixed chaotic EAF model to represent the low frequency and high frequency variations of the arc current respectively has been proposed. The Lorenz system may contribute to the low frequency components of arc current and the logistic equation may contribute to the high frequency components, and the proposed mixed model will be a combination of both Lorenz and logistic model. The concept of chaotic parameters, such as chaotic resistance, inductance of admittance has been also proposed for the characterization of arc furnace operation and the highly nonlinear physical processes. The power quality indices are calculated from the simulated waveforms and compared with the actual power quality indices statistics in order to illustrate the model's capabilities.

  • PDF

Analysis of Density Wave Oscillation in Boiler Furnace Wall Tubes with Parallel Channel Modeling (평행관 모델링을 통한 보일러 화로벽관 내 밀도파 불안정의 해석)

  • Kim, Jinil;Choi, Sangmin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.2
    • /
    • pp.187-196
    • /
    • 2013
  • A numerical model was developed to predict the density wave oscillation (DWO) in the furnace wall tubes of a fossil-fired once-through boiler. The transient flow fields in the tubes were obtained using a 1D finite volume method in the time domain. A header model was also implemented to simulate the parallel tube connection of the wall tubes. The inlet and outlet mass flow variation in one of the parallel tubes was examined after a heat perturbation to find the DWO. After successful verification with experimental results reported in literature, the developed model was applied to the wall tubes of a 700-MW boiler furnace. In contrast to the simulation of Takitani's experiment, in which the unstable power thresholds tended to rise in the reduced bypass channel flow, no remarkable changes were observed in the power thresholds in the parallel channel modeling of the wall tubes of the boiler furnace.

Numerical Simulation of NO Emission and Combustion Characteristics in Furnace (연소로에서 NO 배출 및 연소특성에 대한 수치해석적 연구)

  • 전영남
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.12 no.5
    • /
    • pp.577-585
    • /
    • 1996
  • A screening study was performed in order to resolve the flow, combustion and emission characteristics of the gas furmace with co-axial diffusion flane burner. A control-valume based finite-difference method with the power-law scheme was employed for discretization. Numerical procedure for the differential equation was used by SIMPLEST to enclosute rapid converge. A k-.varepsilon. model was incorporated for the closure of turbulence. The mass fraction and mixture fraction were calculated by cinserved scalar method. An equilibrium analysis was employed to determine the concentration of radicals in the product stream and conserbation equations were them solved for N amd NO by Zelovich reaction scheme. The method was exercised in a simple one-dimensional case first, to determine the effects of air ratio, temperature and residence time on NO formation and applied to a furnace with co-axial diffusion flame burner.

  • PDF

Evaluation on the Prediction Model for the Compressive Strength of Concrete mixing Blast Furnace Slag Powder at early-aged by Maturity Method (적산온도에 의한 고로슬래그 미분말 혼입 콘크리트의 초기재령 압축강도의 예측 모델식 적용성 평가)

  • Yang, Hyun-Min;Park, Won-Jun;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.251-252
    • /
    • 2012
  • The exiting studies on the strength prediction by maturity method is mainly focused on concrete using OPC, meanwhile the study on the concrete mixing blast furnace slag powder (BFSP) is insufficient. The purpose of this study is to investigate the relationships between compressive strength and equivalent age by existing Maturity functions, i.e., Nurse-saul function Arrhenius function. This study also compared and examined the strength prediction of concrete mixing BGSP using ACI model and Logistic Curve prediction equation. Therefore, it is intended that fundamental data are presented for quality management and process management of concrete mixing BFSP.

  • PDF

The Study on the Gas Temperature Set by Calculating the Sensitivity of Slab Temperature in Reheating Furnace (소재온도 감도계산을 통한 가열로내 분위기온도 설정방안 연구)

  • Gang, Deok-Hong;Kim, Gi-Hong;Lee, Yong-Guk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.8
    • /
    • pp.1030-1036
    • /
    • 2001
  • A new mathematical model to determine the optimal gas temperatures in reheating furnace was proposed for the good quality of products. This model employs sensitivity method to calculate the optimal gas temperatures in each zone for heating the slab up to its discharging target temperature and for heating it uniformly. This method was validated by showing that the calculated discharging temperature of the slab was in a good agreement with its prescribed discharging target one through an off-line simulation.

The Numerical Simulation of Ultrafine $SiO_2$ Particle Fabrication and Deposition by Using the Tube Furnace Reactor (튜브형 가열로 반응기를 이용한 초미립 $SiO_2$ 입자의 제조 및 증착에 대한 수치모사)

  • 김교선;현봉수
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.11
    • /
    • pp.1246-1254
    • /
    • 1995
  • A numerical model for fabrication and deposition of ultrafine SiO2 particles were proposed in the simplified horizontal MCVD apparatus using tube furnace reactor. The model equations such as energy and mass balance equations and the 0th, 1st and 2nd moment balance equations of aerosols were considered in the reactor. The phenomena of SiCl4 chemical reaction, SiO2 particle formation and coagulation, diffusion and thermophoresis of SiO2 particles were included in the aerosol dynamic equation. The profiles of gas temperature, SiCl4 concentration and SiO2 particle volume were calculated for standard conditions. The concentrations, sizes and deposition efficiencies of SiO2 particles were calculated, changing the process conditions such as tube furnace setting temperature, total gas flow rate and inlet SiCl4 concentration.

  • PDF

Control Strategy of Smoothing Arc for DC Arc Furnace

  • Jung, Kyungsub;Suh, Yongsug;Lee, Yongjoong;Kim, Taewon;Park, Taejun
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.354-355
    • /
    • 2013
  • Fundamental features of the arc stability in DC arc furnace of 720V/100kA/72MW have been investigated. Cassie-Mayr arc model has been employed and applied for the target dc arc furnace. In order to characterize the parameters of Cassie-Mayr arc model and the behavior of unstable arc dynamics, the advanced arc simulations of magneto-hydrodynamics (MHD) has been performed. The MHD based arc simulation has been validated in the subcomponent level, for the free burning arc set up in the laboratory. From the results of MHD simulation, dc arc dynamic resistance is proposed to be an effective arc stability function reflecting the instability of dynamic arc behavior. The experimental result confirms the usefulness of proposed dynamic arc resistance as arc stability function. The proposed arc stability function can be regarded as an effective criterion for the overall power conversion system to maintain highly stable arcing operation leading to better productivity and reliability.

  • PDF

Control Algorithm of Thyristor Rectifier to Improve Arc Stability in DC Arc Furnace

  • Jung, Kyungsub;Suh, Yongsug;Kim, Taewon;Park, Taejun
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.371-372
    • /
    • 2012
  • In this paper fundamental features of the arc stability in DC arc furnace of 720V/100kA/72MW have been investigated. Cassie-Mayr arc model has been employed for the target dc arc furnace. In order to characterize the parameters of Cassie-Mayr arc model and the behavior of unstable arc dynamics, the advanced arc simulations of magneto-hydrodynamics (MHD) has been performed. Based on the results of MHD simulation, dc arc dynamic resistance is proposed to be an effective arc stability function reflecting the instability of dynamic arc behavior. The experimental result confirms the usefulness of proposed dynamic arc resistance as arc stability function. The proposed arc stability function can be regarded as an effective criterion for the overall power conversion system to maintain highly stable arcing operation leading to better productivity and reliability.

  • PDF

Prediction of Compressive Strength Using Setting Time and Apparent Activation Energy of Blast Furnace Slag Concrete (응결시간과 겉보기 활성화 에너지를 이용한 고로슬래그 콘크리트의 압축강도 예측에 관한 연구)

  • Kim, Han-Sol;Yang, Hyun-Min;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.101-102
    • /
    • 2021
  • The compressive strength of concrete is greatly affected by the temperature inside the concrete at the initial age immediately after pouring. The apparent activation energy of cement and the setting time of concrete are major factors influencing the development of compressive strength of concrete. This study measured the apparent activation energy and setting time according to the change in W/B for each mixing rate of Ground Granulated Blast-Furnace Slag (GGBFS). And after calculating the compressive strength prediction model, the accuracy of the prediction model was evaluated by comparing the predicted compressive strength and the compressive strength.

  • PDF