• Title/Summary/Keyword: Model following control

Search Result 940, Processing Time 0.037 seconds

Structural Design of Sliding Mode Controllers Using Robust Inernal-Loop Compensator (강인 내부루프 보상기를 이용한 슬라이딩 모드 제어기의 구조적 설계)

  • Kim, Bong-Keun;Chung, Wan-Kyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.4
    • /
    • pp.351-361
    • /
    • 2001
  • In this paper, a generalized framework called as robust internal-loop compensator(RIC) is presented, and by using this, a structural design method of sliding of sliding mode controller is proposed. First, a general sliding mode controller is derived and a stabilizing control input is designed based on Lyapunov redesign for the system in the presence of uncertainty and disturbance. And adopting the internal model following control, RIC is proposed. Next, using the structural characteristics of the proposed RIC, disturbance attenuation characteristics are analyzed and the performance of the closed-loop system is predicted. Through this analysis, it is shown that if the control gain of RIC is increased by N times, the magnitude of error is reduced to its 1/N. the proposed method is verified through experiments using a high-precision positioning system and the performance is evaluated.

  • PDF

Control Law Design Optimization for Helicopter Handling Qualities Using CONDUIT (CONDUIT을 이용한 헬리콥터 조종성에 대한 비행제어법칙 설계 및 최적화)

  • Lee, Jangho;Kim, Eung-Tai;Lee, Sugchon;Ryu, Hyeok
    • Journal of Aerospace System Engineering
    • /
    • v.6 no.2
    • /
    • pp.23-27
    • /
    • 2012
  • The evaluation of simulation models against ADS-33 quantitative rotorcraft handling qualities metrics has, in the past, been a time consuming effort, involving many individual analyses in both the time and frequency domains. Manual tuning of control system parameters to meet handling qualities and performance specifications has been cumbersome and complicated. Performing rigorous trade-off studies for numerous variations in the control system is too time consuming to be practicable. With the complex interaction of time- and frequency based specifications for the closed- and broken-loop responses, it is difficult to know if the design makes the most effective use of the available control power. The Control Designer's Unified Interface (CONDUIT) software makes possible rapid optimization and trade-offs of design configurations against handling qualities specifications.

Model Predictive Control of Three-Phase Inverter for Uninterruptible Power Supply Applications under a Hexagonal Input Constraint Region (육각형 입력제약 공간을 이용한 무정전 전원장치의 모델예측제어)

  • Kim, Seok-Kyoon;Kim, Jung-Su;Lee, Young Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Using the classical cascade voltage control strategy, this paper proposes an analytical solution to an MPC (Model Predictive Control) problem with a hexagonal input constraint set for the inner-loop to regulate the output voltage of the UPS (Uninterruptible Power Supply). Focus is placed on how to deal with the hexagonal input constraint set without any approximation. Following the conventional cascade voltage control strategy, the PI (Proportional-Integral) controller is used in the outer-loop in order to regulate the output voltage. The simulation results illustrate that the capacitor voltage rapidly goes to its reference in a satisfactory manner while keeping other state variables bounded under an unexpected load changes.

An optimization of activated sludge process in wastewater treatment system utilizing fuzzy graphic simulator (퍼지 그래픽 시뮬레이터를 이용한 하수처리 시스템 활성오니공정의 최적화)

  • Nahm, Eui-Suck;Park, Jong-Jin;Woo, Kwang-Bang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.2
    • /
    • pp.204-213
    • /
    • 1997
  • In this paper, an application of fuzzy-neuron reasoning to the control of an activated sludge plant is presented. The activated sludge process is widely used in modern wastewater treatment plants. The operation control of the activated sludge process, however, is difficult due to the following reasons : 1)The complexity of the wastewater components, 2)the change of the wastewater influent, and 3)the adjustment errors in the control process. Because of these reasons, it is difficult to obtain mathematical model that really reflect the relationship between the variables and parameters in the process of wastewater treatment correctively and effectively. In this paper, the activated sludge process(A.S.P.) is modeled by a new fuzzy-neuron network representing nonlinear characteristics. These fuzzy-neurons have fuzzy rules with complementary membership function. Based on the constructed model, graphic simulator on X-window system as a graphic integrated environment is implemented. The efficacy of the proposed control scheme was evaluated and demonstrated by means of the field test.

  • PDF

High precision position synchronous control in a multi-axes driving system (II) (다축 구동 시스템의 정밀 위치동기 제어(II))

  • 양주호;변정환;김영복;정석권
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.3
    • /
    • pp.98-106
    • /
    • 1997
  • In this paper, a new method of position synchronizing control is proposed for multi-axes driving system. The proposed position synchronizing control system is constituted with speed and synchronizing controller. The speed controller is aimed at the following to speed reference. Furthermore, it is designed to guarantee low sensitivity under some disturbance as well as robustness against model uncertainties using $H_{\infty}$technique. The synchronizing controller is designed to keep minimizing the position error using PID control law which is considered to reduce the dimension of transfer function in the control system. Especially, the proposed method can be easily conducted by controlling only slave axis speed, because it, has variable structure which is decided to master and slave axis by the sign of synchronizing error. Therfore, the master axis which is smaller influenced than another axes by disturbance can be controlled without reducing or increasing its speed for precise position synchronization. The effectiveness of the proposed method is sucessfully confirmed through many experiments.s.

  • PDF

Development of the Competency Model for Prevention of Adolescent Risk Behavior (청소년의 위험행동 예방을 위한 역량모델 개발)

  • Park, Hyun-Sook;Jung, Sun-Young
    • Journal of Korean Academy of Nursing
    • /
    • v.41 no.2
    • /
    • pp.204-213
    • /
    • 2011
  • Purpose: This study was done to identify fundamental data on competency reinforcement programs to prevent adolescent risk behavior by developing and examining a competency model. Methods: In this study, competences on prevention of adolescent risk behavior were identified through competency modeling, and a competency model was developed and tested for validity. Results: Competences for prevention of adolescent risk behavior defined by the competency model included the following: self-control, positive mutual understanding between parents and adolescents, and positive connectedness with peer group. Validation of the competency model showed the model to be appropriate. Conclusion: The competency model for prevention of adolescent risk behavior through competency modeling is expected to be the foundation of an integral approach to enhance competency in adolescents and prevent adolescent risk behavior. This kind of approach can be a school-centered, cost-efficient strategy, which not only reduces adolescent risk behavior but also improves quality of adolescent resources.

Quantization Modeling of Intra Frame for Rate Control (비트율 제어를 위한 인트라 프레임 양자화 모델링)

  • Park, Sang-Hyun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.10
    • /
    • pp.1207-1214
    • /
    • 2014
  • The first frame of a GOP is encoded in intra mode which generates a larger number of bits. In addition, the first frame is used for the inter mode encoding of the following frames. Thus the encoding results of the intra frame affects the first frame as well as the following frames. Traditionally, the quantization parameter for an intra frame is determined only depending on the bpp not considering the characteristics of the intra frame. For accurate intra frame encoding, we should consider not only bpp but also the complexity of the video sequence and the output bandwidth. In this paper, we propose a real-time quantization model which is used to calculate the quantization parameter for an intra frame encoding based on the investigation on the characteristics of a GOP. It is shown by experimental results that the proposed quantization model captures the characteristics of an intra frame effectively and the proposed method for model parameters accurately estimates the real values.

Robust Minimum-Time Control with Coarse/Fine Dual-Stage Mechanism

  • Kwon, Sang-Joo;Cheong, Joo-No
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.11
    • /
    • pp.1834-1847
    • /
    • 2006
  • A robust minimum-time control (RMTC) strategy is addressed and it is extended to the dual-stage servo design. Rather than conventional switching type sub-optimal controls, it is a reference following control approach where the predetermined minimum-time trajectory (MTT) is tracked by the perturbation compensator based feedback controller. First, the minimum-time trajectory for a mass-damper system is derived. Then, the perturbation compensator to achieve robust tracking performance in spite of model uncertainty and external disturbance is suggested. The RMTC is also applied to the dual-stage positioner which consists of coarse actuator and fine one. To best utilize the actuation redundancy of the dual-stage mechanism, a null-motion controller to actively regulate the relative motion between the two stages is formulated. The performance of RMTC is validated through simulation and experiment.

Frame Vibration Suppression Method for Sensorless PMSM Drive Applications

  • Suthep, Supharat;Wang, Yankai;Ishida, Muneaki;Yamamura, Naoki;Yubai, Kazuhiro;Komada, Satoshi
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2182-2191
    • /
    • 2016
  • This study proposes a novel frame anti-vibration controller for position sensorless PMSM drive application. This controller is called specific component reduction controller (SCRC). SCRC can function without an accelerometer and can achieve speed variable control. This study mainly comprises the following phases. First, the position sensorless control method will be provided. Second, the frame vibration model and load torque ripple will be shown. Third, SCRC will be discussed and its stability will be analyzed. Finally, experimental results show that SCRC can achieve speed variable anti-vibration control and compensate target frequency torque ripple.

Attitude Control of Helicopter Simulator System using A Hybrid GA-PID WAVENET Controller (Hybrid GA-PID WAVENET 제어기를 이용한 모형 헬리콥터 시스템의 자세 제어)

  • 박두환;지석준;이준탁
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.6
    • /
    • pp.433-439
    • /
    • 2004
  • The Helicopter Simulator System is non-linear and complex. Futhermore, because of absence of its accurate mathematical model, it is difficult to control accurately its attitudes such as elevation angle and azimuth one. Therefore, we proposed a Hybrid GA-PID WAVENET(Genetic Algorithm Proportional Integral Derivative Wavelet Neural Network)control technique to control efficiently these angles. The proposed Hybrid GA-PID WAVENET is made through the following process. First, the WAVENET fundamental functions are defined. And their dilation and translation values are adjusted by GA to construct the optimal WAVENET controller. Secondly, the proportional, integral, and derivative gain coefficients of PR controller are tuned optimally. Finally, WAVENET controller which has a good transient characteristic and GA-PE controller which has a good steady state characteristic is adequately combined in hybrid type. Through the computer simulations, it is proved that the Hybrid GA-PE WAVENET control technique has a more excellent dynamic response than PID control technique and GA-PID one.