Seismic retrofit of a steel-reinforced concrete hospital building using continuous energy-dissipative steel columns

  • Massimiliano Ferraioli;Biagio Laurenza;Angelo Lavino;Ciro Frattolillo;Gianfranco De Matteis
    • Steel and Composite Structures
    • /
    • 제47권4호
    • /
    • pp.467-488
    • /
    • 2023
  • Seismic retrofit of an existing steel-reinforced concrete hospital building that features innovative use of a continuous energy-dissipative steel column (CEDC) system is presented in this paper. The special system has been adopted to provide an efficient solution taking into account the difficulties of applying traditional intervention techniques to minimize the impact on architectural functionality and avoid the loss of building function and evacuation during the retrofit implementation. The lateral stiffness and strength of the CEDC system were defined based on the geometric and mechanical properties of the steel strip dampers. The hysteretic behavior under cyclic loadings was defined using a simplified numerical model. Its effectiveness was validated by comparing the results of full-scale experimental data available from the literature. All the main design considerations of the retrofitting plan are described in detail. The effectiveness of the proposed retrofitting system was demonstrated by nonlinear time-history analyses under different sets of earthquake-strong ground motions. The analysis results show that the CEDC system is effective in controlling the deformation pattern and significantly reducing damage to the existing structure during major earthquakes.

RC기둥의 내진성능평가를 위한 재료비선형 상사법칙 (Similitude Law on Material Non-linearity for Seismic Performance Evaluation of RC Columns)

  • 이도근;조재열
    • 콘크리트학회논문집
    • /
    • 제22권3호
    • /
    • pp.409-417
    • /
    • 2010
  • 지진에 의한 사회기반 구조물의 손상은 대형참사를 유발할 가능성이 크므로, 적절한 내진성능평가가 이루어져야한다. 특히 지진하중 하에서 구조물의 거동은 상부 하중을 지탱하는 기둥의 거동에 지배되므로 기둥에 대한 해석 및 실험을 통한 내진성능평가는 가장 핵심적인 요소이다. 현재 내진성능평가 실험의 일환으로 준정적실험, 유사동적실험, 진동대실험 등이 대표적으로 수행되고 있으며 이러한 실험을 수행 시 시험체의 크기, 실험장비 성능의 한계, 경제적인 이유 등으로 원형 구조물을 대신하여 축소모형을 통해 실험을 수행하고 있다. 이러한 축소모형실험을 위해서는 적절한 상사법칙을 적용해야 하는데, 현재 일반적으로 적용되고 있는 상사법칙은 탄성범위 내에서 유도가 되어 있기 때문에 지진하중하 구조물의 비탄성 거동을 예측하는데 무리가 있다. 또한 마이크로콘크리트를 사용한 축소모형에 대해서는 필연적으로 재료특성에 있어서 원형재료와 축소모형재료 사이에 왜곡이 발생하여 결과의 신뢰성에 영향을 주게된다. 따라서 이 연구에서는 재료의 왜곡과 비탄성 거동을 고려하여 새로운 상사법칙을 제시하였다.

내진 설계를 위한 에너지 소산량 산정법의 활용 (Application of Energy Dissipation Capacity to Earthquake Design)

  • 임혜정;박홍근;엄태성
    • 한국지진공학회논문집
    • /
    • 제7권6호
    • /
    • pp.109-117
    • /
    • 2003
  • 기존의 비선형 정적 및 동적 해석에서는 철근콘크리트 구조물의 에너지 소산능력을 정확히 고려하지 못하고 있다. 최근 연구에서는 휨지배 철근콘크리트 부재의 에너지 소산능력을 정확히 평가할 수 있는 식이 개발되었으며, 본 연구에서는 이 평가방법을 이용하여 에너지 소산능력을 정확히 고려할 수 있는 비선형 정적 및 동적 해석 방법을 개발하였다. 비선형 정적 해석을 위하여 에너지 스펙트럼 곡선을 개발하고 이를 적용하여 능력스펙트럼법을 개선하였으며, 또한 비선형 동적 해석을 위하여 철근콘크리트 부재의 단순화된 에너지 기초 주기거동모델을 개발하였다. 제안된 모델은 부재의 강성에 기초한 기존의 주기거동모델과는 달리 완전한 주기거동 발생시 소산되는 에너지를 정확하게 반영할 수 있다. 본 연구에서는 제안된 방법에 따라 비선형 정적 및 동적 해석법의 절차를 정립하였으며 이를 적용한 컴퓨터 해석 프로그램을 개발하였다. 제안된 해석 방법은 부재의 단면형태, 철근비, 배근형태 등 설계 변수에 따른 에너지 소산능력을 정확하게 고려하고 지진발생시 에너지 소산능력이 구조물의 성능에 미치는 효과를 반영할 수 있다.

보건소의 환경, 조직구조와 조직유효성과의 관계 (A Study on Relationships Between Environment, Organizational Structure, and Organizational Effectiveness of Public Health Centers in Korea)

  • 윤순녕
    • 지역사회간호학회지
    • /
    • 제6권1호
    • /
    • pp.5-33
    • /
    • 1995
  • The objective of the study are two-fold: one is to explore the relationship between environment, organizational structure, and organizational effectiveness of public health centers in Korea, and the other is to examine the validity of contingency theory for improving the organizational structure of public health care agencies, with special emphasis on public health nursing administration. Accordingly, the conceptual model of the study consisted of three different concepts: environment, organizational structure, and organizational effectiveness, which were built up from the contingency theory. Data were collected during the period from 1st of May through 30th of June, 1990. From the total of 249 health centers in the country, one hundred and five centers were sampled non proportionally, according to the geopolitical distribution. Out of 105, 73 health centers responded to mailed questionnaire. The health centers were the unit of the study, and a various statistical analysis techniques were used: Reliability analysis(Cronbach's Alpha) for 4 measurement tools; Shapiro-Wilk statistic for normality test of measured scores of 6 variables: ANOVA, Pearson Correlaion analysis, regressional analysis, and canonical correlation analysis for the test of the relationships and differences between the variables. The results were. as follows : 1. No significant differences between forma lization, decision-making authority and environmental complexity were found(F=1.383, P=.24 ; F=.801, P=.37). 2. Negative relationships between formalization and decision-making authority for both urban and rural health centers were found(r=-.470, P=.002 ; r=-.348, P=.46). 3. No significant relationship between formalization and job satisfaction for both urban and rural health centers were found (r=-.242, P=.132, r=-.060, P=.739). 4. Significant positive relationship between decision - making authority and job satisfaction were found in urban health centers (r=.504, P=.0009), but no such relationship was observed in rural health centers. Regression coefficient between them was statistically significant($\beta=1.535$, P=.0002), and accuracy of regression line was accepted (W=.975, P= .420). 5. No significant relationships among formalization and family planning services, maternal health services, and tuberculosis control services for both urban and rural health centers were found. 6. Among decision-making authority and family planning services, maternal health services, and tuberculosis control services, significant positive relationship was found between de cision-making authority and family planning services(r=.286, P=.73). 7. A significant difference was found in maternal health services by the type of health centers (F=5.13, P=.026) but no difference was found in tuberculosis control services by the type of health centers, formalization, and decision-making authority. 8. A significant positive relationships were found between family planning services and maternal health services and tuberculosis control services, and between maternal health services and tuberculosis control services (r=-.499, P=.001 ; r=.457, P=.004 ; r=.495, P=.002) in case of urban health centers. In case of rural health centers, relationships between family planning services and tuberculosis control services, and between maternal health services and tuberculosis control services were statistically significant (r=.534, P=.002 ; r=.389, P=.027). No significant relationship was found between family planning and maternal health services. 9. A significant positive canonical correlation was found between the group of independent variables consisted of formalization and de cision-making authority and the group of dependent variables consisted of family planning services, maternal health services and tuberculosis control services(Rc=.455, P=.02). In case of urban health centers, no significant canonical correlation was found between them, but significant canoncial correlation was found in rural health centers(Rc=.578, P=.069), 10. Relationships between job satisfaction and health care productivity was not found significant. Through these results, the assumed relationship between environment and organizational structure was not supported in health centers. Therefore, the relationship between the organizational effectiveness and the congruence between environment and organizational structure that contingency theory proposes to exist was not able to be tested. However decision-making authority was found as an important variable of organizational structure affecting family planning services and job satisfaction in urban health centers. Thus it was suggested that decentralized decision making among health professionals would be a valuable strategy for improvement of organizational effectiveness in public health centers. It is also recommended that further studies to test contingency theory would use variability and uncertainty to define environment of public health centers instead of complexity.

  • PDF

퍼지의사결정을 이용한 RC구조물의 건전성평가 (Integrity Assessment for Reinforced Concrete Structures Using Fuzzy Decision Making)

  • 손용우;정영채;김종길
    • 한국전산구조공학회논문집
    • /
    • 제17권2호
    • /
    • pp.131-140
    • /
    • 2004
  • 철근콘크리트 구조물의 보수ㆍ보강 등의 유지관리를 위해서는 내구성과 내하성을 동시에 고려한 건전성평가의 의사결정기준이 절실히 요구된다. 본 논문은 CART-ANFIS을 사용하는 철근콘크리트 구조물에 대하여 효율적인 모델을 나타내었다. 철근콘크리트 구조물의 손상과 진단 등에 활용되어온 분류형 전문가시스템의 일종인 퍼지이론을 이용한 결정목 구조와 기존의 인공신경망을 이용한 결정목 구조의 건전성평가를 비교 분석한다. 손상된 철근콘크리트의 내구성 회복을 위한 보강설계 이론과 내하력 증가를 위한 보장설계 이론을 정립시켜 손상검출의 산정식을 유도하였다. 본 연구의 건전성 평가시스템 모델을 이용함으로서 보다 효율적인 철근콘크리트 유지관리 뿐만 아니라 생애주기비용 예측을 수행 할 수 있다.

Estimation of fundamental natural period of vibration for reinforced concrete shear walls systems

  • Shatnawi, Anis S.;Al-Beddawe, Esra'a H.;Musmar, Mazen A.
    • Earthquakes and Structures
    • /
    • 제16권3호
    • /
    • pp.295-310
    • /
    • 2019
  • This study attempts to develop new simplified approximate formulas to predict the fundamental natural periods of vibration (T) for bearing wall systems engaged with special reinforced concrete shear walls (RCSW) under seismic loads. Commonly, seismic codes suggested empirical formulas established by regression analysis of measured T for buildings during earthquake motions. These formulas depend on structure type, building height, number, height and length of SW, and ratio of SW area to base area of structure. In this study, a parametric investigation is performed for T of 110 selected models of bearing RCSW systems with varying structural height, configuration of horizontal plans including building width, number and width of bays, presence of middle corridors and core SWs. For this purpose, a 3D non-linear response time history (TH) analysis is implemented using ETABS v16.2.1. New formulas to estimate T are anticipated and compared with those obtained from formulas of IBC 2012 and ASCE/SEI 7-10. Moreover, the study examines responses of an arbitrarily two selected test model of 60 m and 80 m in height with presence of SWs having middle corridors. It is observed that the performance of the tested buildings is different through arising of considerable errors when using codes' formulas for estimating T. Accordingly, using the present proposed formulas exhibits more reasonable and safer design compared to codes' formulas. The results showed that equitable enhancement is promising to improve T formulas approaching enhanced and accurate estimation of T with reliable analysis, design, and evaluation of bearing RCSW systems.

그라우트 주입률 변화에 따른 전단탄성계수 평가 (Evaluation of Shear Elastic Modulus by Changing Injection Ratio of Grout)

  • 백승철;이준대;안광국
    • 한국지반환경공학회 논문집
    • /
    • 제14권2호
    • /
    • pp.51-55
    • /
    • 2013
  • 연약지반을 개량하기 위한 심층혼합처리공법과 같은 다양한 공법은 지반보강을 위하여 그라우트를 광범위하게 사용하고 있다. 반복하중 및 동하중을 받는 지반-구조물계의 설계에 사용되는 중요한 동적변수는 사질토 및 화강풍화토, 암시편에 관하여 많이 연구 발표되었다. 하지만 그라우트로 보강된 지반에 대한 내진설계 연구는 미비한 실정이다. 이에 본 연구에서는 공진주시험기를 이용하여 점성토와 보통 포틀랜드 시멘트의 함수비와 그라우트 주입률의 변화에 따른 전단변형률과 전단탄성계수의 상관관계를 Ramberg-Osgood Model로 정규화하여 비교 분석하였다. 그 결과 동적계수는 함수비와 그라우트 주입율에 의해 영향을 받는 것으로 나타났다.

BIM 기반 프리패브 부재의 용접철근매트 정보교환 시스템 (BIM based Data Exchange System of Welded Wire/bar Mat for Pre-fab RC Members)

  • 정재환;김도형;김현기
    • 한국BIM학회 논문집
    • /
    • 제11권1호
    • /
    • pp.21-30
    • /
    • 2021
  • Reinforcing bars, a major component of the pre-fab structure, adheres to the existing on-site assembly method and attempts to develop and commercialize the technology of the pre-assembly method, but the effect is insignificant. Welded Wire / Bar Mat (WBM) has various advantages such as commercialization of rebar through machine manufacturing to improve workability, but it is different from the existing design and the construction method is different from the previous one. Therefore, to maximize the advantages of WBM and improve productivity, manufacturing, transportation, and construction from the design stage should be considered based on BIM from the initial design stage. In this paper, the concept of the design support system for the WBM was established based on the use of BIM in concrete reinforcement and the preliminary research on the WBM. WBM conversion design was performed for the existing prefabricated members, and based on this, the exchange format and system of the master prefabricated model with the WBM design data were set up. As a result of the pilot test, it was found that the traditional reinforcing bar information extracted from the master prefab model has transmitted 100% accurately. As for the WBM information, 100% of the information on the straight reinforcement was transmitted and represented, and the information on the bent reinforcement was found to have a 90% recall in the master BIM tool.

Structural member stiffness influence on vertical earthquake behaviour of mid-rise R/C frame buildings in Turkey

  • Selcuk Bas
    • Computers and Concrete
    • /
    • 제33권6호
    • /
    • pp.689-706
    • /
    • 2024
  • This study is aimed at identifying structural element stiffness influence on vertical earthquake response of mid-rise R/C frame buildings. To this aim, a mid-rise RC building structure is designed as per the new Turkish Seismic Code for Buildings-2018, and 3D FE model of the building is established. Based on the established FE model, a total number of six buildings are considered depending on certain percentage increase in beam, slab, and column. The time-history response analyses (THA) are performed separately for only horizontal (H) and horizontal +vertical (H+V) earthquake motions to make a comparison between the load cases. The analysis results are presented comparatively in terms of the monitoring parameters of the base overturning moment (Mo), the top-story lateral displacement (dL) and the top-story vertical displacement (dV). The obtained results reveal that the base overturning moment and the top-story vertical displacement are affected by vertical earthquake motion regardless of the increase in the dimension of beam, slab, and column. However, vertical earthquake motion is not effective on the top-story lateral displacement due to no change between H and H+V load. The dimensional increase in either slab or beam leads to a considerable increase in the base overturning moment and the top-story vertical displacement while causing decrease in the top-story lateral displacement. In addition, the dimensional increase in column has a positive effect on the decrease in the monitoring parameters of the base overturning moment (Mo), the top-story lateral displacement (dL) and the top-story vertical displacement (dV).

복부 파형강판을 사용한 PSC 복합 교량의 비틀림 해석모델의 제안 및 변수해석 (A Development of Torsional Analysis Model and Parametric Study for PSC Box Girder Bridge with Corrugated Steel Web)

  • 이한구;김광수
    • 대한토목학회논문집
    • /
    • 제28권2A호
    • /
    • pp.281-288
    • /
    • 2008
  • 콘크리트와 강재의 특성을 살린 복합구조 교량에 있어서 새로운 구조 형식인 복부 파형강판 PSC 박스거더 교량은 시공성 및 경제적인 측면에서 우수한 장점이 있다. 그러나 이와 관련된 기존 연구는 전단 좌굴에 대한 복부 파형강판의 거동 및 접합부의 형상 개발과 관련하여 한정된 측면이 있으며, 교량 자체로서의 비틀림 거동에 대한 연구는 다소 부족한 실정으로 합리적인 비틀림 해석모델의 개발과 거동 예측에 대한 연구가 필요하다고 판단된다. 본 연구에서는 복부 파형강판 PSC 박스거더 교량에 대하여, 공간트러스 모델을 이용한 Rausch의 제안식과 RC 요소의 연화효과가 고려된 평형 방정식, 적합 조건식을 활용하고 복부 파형강판 구조 형태에 의하여 추가적으로 고려해야 할 구성 방정식과 모델, 제안식 등을 적용한 비틀림 해석모델을 제시하고 기존에 수행된 부재 실험결과와의 비교를 통하여 해석모델의 합리성을 검토하였다. 또한 복부 파형강판 PSC 박스의 비틀림 거동에 영향을 미치는 프리스트레싱 힘과 콘크리트 압축강도를 변수로 한 해석을 진행하였으며, 제안된 비틀림 해석모델을 이용하여 복부 파형 강판과 프리스트레스 된 콘크리트 부재의 단면 형상비(H/B)에 따른 해석을 수행하여 보다 합리적인 비틀림 정수와 이와 관련한 수정식을 제안하였다.