• Title/Summary/Keyword: Model Library

Search Result 1,528, Processing Time 0.027 seconds

Development of a Multi-body Dynamics Analysis System Using the Object-Oriented Concept (객체지향 개념을 이용한 다물체 동역학 해석 시스템 개발)

  • 한형석;이재경;서종휘;송현석;박태원
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.8
    • /
    • pp.115-125
    • /
    • 2003
  • To analyze the applications of all types of mechanical systems, general purpose analysis programs have been developed and commercialized. However, it is customary to develop and use customized programs even though they sometimes require more work than a general purpose program. A customized program is simplified to adapt to a particular application from the beginning, is designed for small computers, and developed with hardware-in-the-loop in mind so it can be applied effectively. By adding design knowledge and bundling know-how to an analysis program, analysis time can be reduced. And because an analysis has to work in conjunction with other analysis programs, a proprietary program that the user can easily modify can be useful. In this thesis, a multi-body dynamics analysis system is presented using one of the most useful programming techniques, object-oriented concept. The object-oriented concept defines a problem from the physical world as an abstract object, an abstract model. The object becomes encapsulated with the data and method. Simulation is performed using the object's interface. It is then possible for the user and the developer to modify and upgrade the program without having particular knowledge of the analysis program. The method presented in this thesis has the following advantages. Since the mechanical components of the multi-body system converts independent modeling into a class, the modification, exchange, distribution, and reuse of elements are increased. It becomes easier to employ a new analysis method and interface with other S/W and H/W systems. To employ a new analysis method, there is no need to modify elements of the main solver and the Library. In addition, information can be communicated to each object through messaging. It makes the modeling of new elements easier using inheritance. When developing a S/W for the computer simulation of physical system, it is reasonable to use object-oriented modeling. Also, for multi-body dynamics analysis, it is possible to develop a solver that is user-oriented.

Limited Diagnostic Value of microRNAs for Detecting Colorectal Cancer: A Meta-analysis

  • Zhou, Xuan-Jun;Dong, Zhao-Gang;Yang, Yong-Mei;Du, Lu-Tao;Zhang, Xin;Wang, Chuan-Xin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4699-4704
    • /
    • 2013
  • Background: MicroRNAs have been demonstrated to play important roles in the development and progression of colorectal cancer. Several studies utilizing microRNAs as diagnostic biomarkers for colorectal cancer (CRC) have been reported. The aim of this meta-analysis was to comprehensively and quantitatively summarize the diagnostic value of microRNAs for detecting colorectal cancer. Methods: We searched PubMed, Embase and Cochrane Library for published studies that used microRNAs as biomarkers for the diagnosis of colorectal cancer. Summary estimates for sensitivity, specificity and other measures of accuracy of microRNAs in the diagnosis of colorectal cancer were calculated using the bivariate random effects model. A summary receiver operating characteristic (SROC) curve was also generated to summarize the overall effectiveness of the test. Result: Thirteen studies from twelve published articles met the inclusion criteria and were included. The overall sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odd ratio of microRNAs for the diagnosis of colorectal cancer were 0.81 (95%CI: 0.79-0.84), 0.78 (95%CI: 0.75-0.82), 4.14 (95%CI: 2.90-5.92), 0.24 (95%CI: 0.19-0.30), and 19.2 (95%CI: 11.7-31.5), respectively. The area under the SROC curve was 0.89. Conclusions: The current evidence suggests that the microRNAs test might not be used alone as a screening tool for CRC. Combining microRNAs testing with other conventional tests such as FOBT may improve the diagnostic accuracy for detecting CRC.

Refining and Validating a Two-stage and Web-based Cancer Risk Assessment Tool for Village Doctors in China

  • Shen, Xing-Rong;Chai, Jing;Feng, Rui;Liu, Tong-Zhu;Tong, Gui-Xian;Cheng, Jing;Li, Kai-Chun;Xie, Shao-Yu;Shi, Yong;Wang, De-Bin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.24
    • /
    • pp.10683-10690
    • /
    • 2015
  • The big gap between efficacy of population level prevention and expectations due to heterogeneity and complexity of cancer etiologic factors calls for selective yet personalized interventions based on effective risk assessment. This paper documents our research protocol aimed at refining and validating a two-stage and web-based cancer risk assessment tool, from a tentative one in use by an ongoing project, capable of identifying individuals at elevated risk for one or more types of the 80% leading cancers in rural China with adequate sensitivity and specificity and featuring low cost, easy application and cultural and technical sensitivity for farmers and village doctors. The protocol adopted a modified population-based case control design using 72, 000 non-patients as controls, 2, 200 cancer patients as cases, and another 600 patients as cases for external validation. Factors taken into account comprised 8 domains including diet and nutrition, risk behaviors, family history, precancerous diseases, related medical procedures, exposure to environment hazards, mood and feelings, physical activities and anthropologic and biologic factors. Modeling stresses explored various methodologies like empirical analysis, logistic regression, neuro-network analysis, decision theory and both internal and external validation using concordance statistics, predictive values, etc..

The Design of Hardware MPI Units for MPSoC (MPSoC를 위한 저비용 하드웨어 MPI 유닛 설계)

  • Jeong, Ha-Young;Chung, Won-Young;Lee, Yong-Surk
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.1B
    • /
    • pp.86-92
    • /
    • 2011
  • In this paper, we propose a novel hardware MPI(Message Passing Interface) unit which supports message passing in multiprocessor system which use distributed memory architecture. MPI Hardware unit processes data synchronization, transmission and completion, and it supports processor non-blocking operation so it reduces overhead according to synchronization. Additionally, MPI hardware unit combines ready entry, request entry, reserve entry which save and manage the synchronized messages and performs the multiple outstanding issue and out of order completion. According to BFM(Bus Functional Model) simulation result, the performance is increased by 25% on many to many communication. After we designed MPI unit using HDL, with synopsys design compiler we synthesized, and for synthesis library we used MagnaChip $0.18{\mu}m$. And then we making prototype chip. The proposed message transmission interface hardware shows high performance for its increase in size. Thus, as we consider low-cost design and scalability, MPI hardware unit is useful in increasing overall performance of embedded MPSoC(Multi-Processor System-on-Chip).

Implementation of Finger-Gesture Game Controller using CAMShift and Double Circle Tracing Method (CAMShift와 이중 원형 추적법을 이용한 손 동작 게임 컨트롤러 구현)

  • Lee, Woo-Beom
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.15 no.2
    • /
    • pp.42-47
    • /
    • 2014
  • A finger-gesture game controller using the single camera is implemented in this paper, which is based on the recognition of the number of fingers and the index finger moving direction. Proposed method uses the CAMShift algorithm to trace the end-point of index finger effectively. The number of finger is recognized by using a double circle tracing method. Then, HSI color mode transformation is performed for the CAMShift algorithm, and YCbCr color model is used in the double circle tracing method. Also, all processing tasks are implemented by using the Intel OpenCV library and C++ language. In order to evaluate the performance of the proposed method, we developed a shooting game simulator and validated the proposed method. The proposed method showed the average recognition ratio of more than 90% for each of the game command-mode.

Numerical Investigation on Oil Spill from Damaged Riser (손상된 라이저로부터 유출된 기름 확산에 대한 수치해석)

  • Kim, Hyo Ju;Lee, Sang Chul;Park, Sunho
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.2
    • /
    • pp.99-110
    • /
    • 2016
  • When a riser is damaged, the oil spills to sea. Oil spills cause huge economic losses as well as a destruction of the marine environment. To reduce losses, it is needed to predict spilled oil volume from risers and the excursion of the oil. The present paper simulated the oil spill for a damaged riser using open source libraries, called Open-FOAM. To verify numerical methods, jet flow and Rayleigh-Taylor instability were simulated. The oil spill was simulated for various damaged leak size, spilled oil volume rates, damaged vertical locations of a riser, and current speeds. From results, the maximum excursion of the spilled oil at the certain time was predicted, and a forecasting model for various parameters was suggested.

Review on the Pharmacopuncture Patent in Korea (국내 약침 특허 현황에 대한 분석연구)

  • Woo, Seong-Cheon;Kang, Jun-Chul;Kim, Song-Yi;Park, Ji-Yeun
    • Korean Journal of Acupuncture
    • /
    • v.34 no.4
    • /
    • pp.191-208
    • /
    • 2017
  • Objectives : The purpose of this study was to analyze the trend of pharmacopuncture in Korean patent in order to establish database for patent technology. Methods : Electronic literature searches for Korean patents related to pharmacopuncture were performed in two electronic databases (Korea Intellectual Property Right Information Service and National Digital Science Library) to June 2017. Patents that were not Korean ones, did not use medicinal herb, only described method of manufacture, or had nothing to do with pharmacopuncture were excluded in this study. The status and application date of patents, Medicinal herb, target diseases, International Patent Classification (IPC), model of experiment and extracting methods were analyzed. Results : A total of 379 patents were retrieved. Based on our inclusion/exclusion criteria, 297 patents were excluded. Of 82 included patents, 27 patents did not include experiments using pharmacopuncture, and 9 patents were invented for treating animals such as pig or calf. In IPC analysis, Bee Venom, Panax (ginseng), Angelica, and Paeoniaceae were used frequently. Musculoskeletal diseases were the most targeted diseases followed by nervous diseases. For extracting, hot water extraction, distillation extraction, and solvent extraction using alcohol, ethanol, or methanol for solvent were commonly used. Conclusions : These data are useful for inventing new patent and extending range of pharmacopuncture in clinical use, however, more systematically analyzed patent studies and pharmacopuncture-related studies for new application on various diseases are needed in further studies.

Analysis of Distribution Situation and Management System of Thesis and Dissertations (학위논문의 유통현황 및 관리시스템 분석)

  • Yoon, Hee-Yoon
    • Journal of Information Management
    • /
    • v.35 no.2
    • /
    • pp.1-40
    • /
    • 2004
  • Theses and dissertations are works embodying results of original research on a subject and substantiating a particular point of view by usually graduate students, as a degree requirement. Most theses and dissertations are not controlled by commercial publishing interests, and thus are not obtained in book-form by most libraries. Due to their lack of physical and ready availability and information about the contents, theses and dissertations have been extremely underutilized sources of information without distinction of nations. The goal of this paper is to provide the current informations on the distribution and management systems of theses and dissertations in Foreign and Korea. The findings of this study will provide the basis for developing an standardized management model of theses and dissertations that meets the needs of researchers, students, and librarians in Korea.

Computer Vision Based Measurement, Error Analysis and Calibration (컴퓨터 시각(視覺)에 의거한 측정기술(測定技術) 및 측정오차(測定誤差)의 분석(分析)과 보정(補正))

  • Hwang, H.;Lee, C.H.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • When using a computer vision system for a measurement, the geometrically distorted input image usually restricts the site and size of the measuring window. A geometrically distorted image caused by the image sensing and processing hardware degrades the accuracy of the visual measurement and prohibits the arbitrary selection of the measuring scope. Therefore, an image calibration is inevitable to improve the measuring accuracy. A calibration process is usually done via four steps such as measurement, modeling, parameter estimation, and compensation. In this paper, the efficient error calibration technique of a geometrically distorted input image was developed using a neural network. After calibrating a unit pixel, the distorted image was compensated by training CMLAN(Cerebellar Model Linear Associator Network) without modeling the behavior of any system element. The input/output training pairs for the network was obtained by processing the image of the devised sampled pattern. The generalization property of the network successfully compensates the distortion errors of the untrained arbitrary pixel points on the image space. The error convergence of the trained network with respect to the network control parameters were also presented. The compensated image through the network was then post processed using a simple DDA(Digital Differential Analyzer) to avoid the pixel disconnectivity. The compensation effect was verified using known sized geometric primitives. A way to extract directly a real scaled geometric quantity of the object from the 8-directional chain coding was also devised and coded. Since the developed calibration algorithm does not require any knowledge of modeling system elements and estimating parameters, it can be applied simply to any image processing system. Furthermore, it efficiently enhances the measurement accuracy and allows the arbitrary sizing and locating of the measuring window. The applied and developed algorithms were coded as a menu driven way using MS-C language Ver. 6.0, PC VISION PLUS library functions, and VGA graphic functions.

  • PDF

The Operational Comparison of SPOT GCP Acquisition and Accuracy Evaluation

  • Kim, Kam-Lae;Kim, Uk-Nam;Chun, Ho-Woun;Lee, Ho-Nam
    • Korean Journal of Geomatics
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 2001
  • This paper presents an investigation into the operational comparison of SPOT triangulation to build GCP library by analytical plotter and DPW (digital photogrammetric workstation). GCP database derived from current SPOT images can be used to other image sensors of satellite, if any reasons, such as lack of topographic maps or GCPs. But, general formulation of a photogrammetric process for GCP measurement has to take care of the scene interpretation problem. There are two classical methods depending on whether an analytical plotter or DPW is being used. Regardless of the method used, the measurement of GCPs is the weakest point in the automation of photogrammetric orientation procedures. To make an operational comparison, five models of SPOT panchromatic images (level 1A) and negative films (level 1AP) were used. Ten images and film products were used for the five GRS areas. Photogrammetric measurements were carried out in a manual mode on P2 analytical plotter and LH Systems DPW770. We presented an approach for exterior orientation of SPOT images, which was based on the use of approximately eighty national geodetic control points as GCPs which located on the summit of the mountain. Using sixteen well-spaced geodetic control points per model, all segments consistently showed RMS error just below the pixel at the check points in analytical instrument. In the case of DPW, half of the ground controls could not found or distinguished exactly when we displayed the image on the computer monitor. Experiment results showed that the RMS errors with DPW test was fluctuated case by case. And the magnitudes of the errors were reached more than three pixels due to the lack of image interpretation capability. It showed that the geodetic control points is not suitable as the ground control points in DPW for modeling the SPOT image.

  • PDF