• Title/Summary/Keyword: Mode vectors

Search Result 138, Processing Time 0.025 seconds

Joint-characteristic Function of the First- and Second-order Polarization-mode-dispersion Vectors in Linearly Birefringent Optical Fibers

  • Lee, Jae-Seung
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.228-234
    • /
    • 2010
  • This paper presents the joint characteristic function of the first- and second-order polarization-modedispersion (PMD) vectors in installed optical fibers that are almost linearly birefringent. The joint characteristic function is a Fourier transform of the joint probability density function of these PMD vectors. We regard the random fiber birefringence components as white Gaussian processes and use a Fokker-Planck method. In the limit of a large transmission distance, our joint characteristic function agrees with the previous joint characteristic function obtained for highly birefringent fibers. However, their differences can be noticeable for practical transmission distances.

Comparison of model order reductions using Krylov and modal vectors for transient analysis under seismic loading

  • Han, Jeong Sam
    • Structural Engineering and Mechanics
    • /
    • v.76 no.5
    • /
    • pp.643-651
    • /
    • 2020
  • Generally, it is necessary to perform transient structural analysis in order to verify and improve the seismic performance of high-rise buildings and bridges against earthquake loads. In this paper, we propose the model order reduction (MOR) method using the Krylov vectors to perform seismic analysis for linear and elastic systems in an efficient way. We then compared the proposed method with the mode superposition method (MSM) by using the limited numbers of modal vectors (or eigenvectors) calculated from the modal analysis. In the calculation, the data of the El Centro earthquake in 1940 were adopted for the seismic loading in the transient analysis. The numerical accuracy and efficiency of the two methods were compared in detail in the case of a simplified high-rise building.

Accelerated Starting Vectors for Analysis of Natural Modes of Structures (구조물의 고유모드 해석을 위한 가속화된 초기벡터 구성기법)

  • 김병완;정형조;이인원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.784-787
    • /
    • 2004
  • Modified version of subspace iteration method using accelerated starting vectors is proposed to efficiently calculate free vibration modes of structures. Proposed method employs accelerated Lanczos starting vectors that can reduce the number of iterations in the subspace iteration method. Proposed method is more efficient than the conventional method when the number of required modes is relatively small. To verify the efficiency of proposed method, two numerical examples are presented.

  • PDF

Common-mode Voltage Reduction for Inverters Connected in Parallel Using an MPC Method with Subdivided Voltage Vectors

  • Park, Joon Young;Sin, Jiook;Bak, Yeongsu;Park, Sung-Min;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1212-1222
    • /
    • 2018
  • This paper presents a model predictive control (MPC) method to reduce the common-mode voltage (CMV) for inverters connected in parallel, which increase the capacity of energy storage systems (ESSs). The proposed method is based on subdivided voltage vectors, and the resulting algorithm can be applied to control the inverters. Furthermore, we use more voltage vectors than the conventional MPC algorithm; consequently, the quality of grid currents is improved. Several methods were proposed in order to reduce the CMV appearing during operation and its adverse effects. However, those methods have shown to increase the total harmonic distortion of the grid currents. Our method, however, aims to both avoid this drawback and effectively reduce the CMV. By employing phase difference in the carrier signals to control each inverter, we successfully reduced the CMV for inverters connected in parallel, thus outperforming similar methods. In fact, the validity of the proposed method was verified by simulations and experimental results.

Conducted EMI reduction of Induction Motor Drive System by PWM Switching Technique (PWM 스위칭 기법에 의한 유도전동기 구동시스템의 전도노이즈 저감)

  • Kim H. J.;Lee W. C.;Kim L. H.;Won C. Y.;Choi S. Y.;Kim G. S.;Jeong D. H.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.769-773
    • /
    • 2004
  • Conventional SVPWM method has null switching vectors. Null switching vectors cause high common-mode voltage in induction motor drive system. The newly developed common mode voltage reduction PWM technique don't use zero switching state for inverter control. It is realized by changing software without additional hardware. Simulation and experimental results show that proposed method are reduced common mode voltage more than conventional method.

  • PDF

Temporal Directmode for B Picture in H.264 / MPEG-4 AVC (H.264 / MPEG-4 AVC에서의 B 픽쳐를 위한 시간적 다이렉트 모드)

  • 전병문
    • Journal of Broadcast Engineering
    • /
    • v.7 no.4
    • /
    • pp.300-309
    • /
    • 2002
  • The object of this paper is to make temporal direct mode clear by providing a solution to the following problem : if the co-located block in the list 1 reference picture for direct mode has only the 1ist 1 motion vector or both the 1ist 0 and list 1 motion vectors, then which motion vector will be used for the direct mode motion vector calculation\ulcorner This paper also shows how to derive reference picture index and direct mode motion vector for each list in order to guarantee the high coding efficiency. when the co-located macroblock is in intra mode. Furthermore, the reasonable calculation methods for the direct mode motion vectors in the various cases are presented. Finally, experimental results show that the proposed temporal direct mode provides the comparable performance against the spatial direct mode. Therefore, the simulation proves that the proposed temporal direct mode is acceptable.

Common-Mode Voltage Elimination with an Auxiliary Half-Bridge Circuit for Five-Level Active NPC Inverters

  • Le, Quoc Anh;Park, Do-Hyeon;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.923-932
    • /
    • 2017
  • This paper proposes a novel scheme which can compensate the common-mode voltage (CMV) for five-level active neutralpoint clamped (5L-ANPC) inverters, which is based on modifying the space vector pulse width modulation (SVPWM) and adding an auxiliary leg to the inverter. For the modified SVPWM, only the 55 voltage vectors producing low CMV values among the 125 possible voltage vectors are utilized, which varies over the three voltage levels of $-V_{dc}/12$, 0 V, and $V_{dc}/12$. In addition, the compensating voltage, which is injected into the 5L-ANPC inverter system to cancel the remaining CVM through a common-mode transformer (CMT) is generated by the additional NPC leg. By the proposed method, the CMV of the inverter is fully eliminated, while the utilization of the DC-link voltage is not decreased at all. Furthermore, all of the DC-link and flying capacitor voltages of the inverter are well controlled. Simulation and experimental results have verified the validity of the proposed scheme.

DC-Link Voltage Balance Control Using Fourth-Phase for 3-Phase 3-Level NPC PWM Converters with Common-Mode Voltage Reduction Technique

  • Jung, Jun-Hyung;Park, Jung-Hoon;Kim, Jang-Mok;Son, Yung-Deug
    • Journal of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.108-118
    • /
    • 2019
  • This paper proposes a DC-link voltage balance controller using the fourth-phase of a three-level neutral-point clamped (NPC) PWM converter with medium vector selection (MVS) PWM for common-mode voltage reduction. MVS PWM makes the voltage reference by synthesizing the voltage vectors that cannot generate common-mode voltage. This PWM method is effective for reducing the EMI noise emitted from converter systems. However, the DC-link voltage imbalance problem is caused by the use of limited voltage vectors. Therefore, in this paper, the effect of MVS PWM on the DC-link voltage of a three-level NPC converter is analyzed. Then a proportional-derivative (PD) controller for the DC-link voltage balance is designed from the DC-link modeling. In addition, feedforward compensation of the neutral point current is included in the proposed PD controller. The effectiveness of the proposed controller is verified by experimental results.

Investigation of Convergence of Starting Iteration Vectors for Calculating Natural Modes (고유모드 계산을 위한 초기 반복벡터의 수렴성 연구)

  • Kim, Byoung-Wan;Kyoung, Jo-Hyun;Hong, Sa-Young;Cho, Seok-Kyu;Lee, In-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.717-720
    • /
    • 2004
  • Two modified versions of subspace iteration method using accelerated starting vectors are proposed to efficiently calculate free vibration modes of structures. Proposed methods employ accelerated Lanczos vectors as starting iteration vectors in the subspace iteration method. To investigate the efficiency of proposed methods, two numerical examples are presented.

  • PDF

Modified Component Mode Synthesis Method Using Ritz Vectors (Ritz 벡터를 이용한 수정 분할구조해석법)

  • 이인원;김동옥
    • Journal of KSNVE
    • /
    • v.3 no.1
    • /
    • pp.77-82
    • /
    • 1993
  • In general, the dynamic analysis with FEM(Finite Element Method) of large structures requires large computer memory space and long computational time. For the purpose of economical dynamic analysis of large structures, most of engineers want to use an efficient solution algorithm. This paper reports the modified CMS(Component Mode Synthesis) method which uses more efficient algorithm than the classical CMS method. In this paper, it is shown that Ritz vector sets can play the role of normal mode vector sets of substurctures in the CMS algorithm. The modified CMS method has good convergence performance compared with that of the classical CMS method.

  • PDF