• Title/Summary/Keyword: Mode of Operation

Search Result 2,505, Processing Time 0.031 seconds

Dynamic simulation of a solar absorption cooling system (태양열을 이용한 흡수식 냉방기의 동특성 시뮬레이션)

  • 정시영;조광운
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.784-794
    • /
    • 1998
  • The present study has been directed at developing thermal models to investigate the dynamic behavior of a solar cooling system including an absorption chiller, solar collectors, a hot water storage tank, a fan coil unit, and the air-conditioned space. The operation of the system was simulated for 8 hours in two different operation modes. In the mode 1, the system operated without any capacity control.0 the mode 2, an auxiliary boiler supplied heat to the generator if hot water temperature became lower than a certain value. Moreover, the mass flow rate of hot water to the generator was controlled by comparing the instantaneous room air temperature with the design value. The variation of temperature and concentration in the system components and that of heat transfer rates in the system were obtained for both modes of operation. It was found that the room temperature was maintained near the desired value in the mode 2 by supplying auxiliary heat or controlling the mass flow rate of hot water, while the deviation of room temperature was quite great in the mode 2.

  • PDF

Extending the Single-Mode-Operation Radius of the Oxide-VCSEL by Controlling the Thickness and Position of the Oxide-Layer (Oxide층의 두께와 위치 조절을 통한 oxido-VCSEL의 단일모드 동작반경 확장)

  • 김남길;김상배
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.9
    • /
    • pp.31-37
    • /
    • 2004
  • We have proposed a design methodology for large active-area single-mode VCSELS, which have higher reliability and output power, and are well-suited for high-speed operation. The key idea underlying the design methodology is to reduce the effective index difference between active and cladding regions by controlling the thickness and position of the oxide layer. The idea is confirmed by the self-consistent effective index method. By placing the oxide layer position properly, we can increase the radius of the oxide aperture for single-mode operation by 3 times.

Improved full wave mode ZVT-PWM DC-DC Converters (개선된 전파형 ZVT-PWM DC-DC 컨버터)

  • Kim T.W.;Kang A.J.;Chin G.H.;Kim H.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.777-780
    • /
    • 2003
  • In this paper, an improved full wave mode ZVT-PWM DC-DC Converter is presented to maximize the regeneration ratio of resonant energy by only putting an additional diode in series with auxiliary switch. The operation of auxiliary switch in a half wave mode makes possible the soft switching condition of all switches. Furthermore, the increase of the regeneration ratio to resonant energy results in low conduction losses and minimum voltage and current stresses. The operation principles of the proposed converters are analyzed using the PWM boost converter topology as an example. Theoretically analysis and experimental results verify the validity of the boost converter topology with the proposed full wave mode ZVT-PWM converters

  • PDF

The study of operation mode of ventilation system in the longitudinal ventilation system tunnel (조합환기 방식 터널의 환기기 운전 단계에 관한 연구)

  • Yoo, Ji-Oh;Shin, Hyun-Jun;Lee, Dong-Ho;Lee, Young-hwa
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.4 no.4
    • /
    • pp.343-353
    • /
    • 2002
  • In the past many tunnels have been built to lowest capital investment cost without adequate regard for the cost of operation. But according to increasing the capacity of a ventilation system and to becoming diverse, it is to become more important to come up with the optimal operation stage of ventilation system. In this study, the tunnel ventilation dynamic simulation program had been developed. it is used to calculate the unsteady-state tunnel air velocity and concentration of pollutants according to the assumed average day traffic profile and summarize the energy consumption for the operation of ventilation system. And the operation energy consumption for the electric precipitation system and vertical vent shaft system are evaluated and compared in various operation mode. As the results of this study, the optimal operation stage for these ventilation system are provided.

  • PDF

High Power Single Mode Multi-Oxide Layer VCSEL with Optimized Thicknesses and Aperture Sizes of Oxide Layers

  • Yazdanypoor, Mohammad;Emami, Farzin
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.167-173
    • /
    • 2014
  • A novel multi-oxide layer structure for vertical cavity surface emitting laser (VCSEL) structures is proposed to achieve higher single mode output power. The structure has four oxide layers with different aperture sizes and thicknesses. The oxide layer thicknesses are optimized simultaneously to reach the highest single mode output power. A heuristic method is proposed for plotting the influence of these variable changes on the operation of optical output power. A comprehensive optical-electrical thermal-gain self-consistent VCSEL model is used to simulate the continuous-wave operation of the multi-layer oxide VCSELs. A comparison between optimized VCSELs with different structures is presented. The results show that by using multi-oxide layers with different thicknesses, higher single-mode optical output power could be achieved in comparison with multi-oxide layer structures with the same thicknesses.

Performance of Double Fed Induction Machine at Sub- and Super-Synchronous Speed in Wind Energy Conversion System

  • Eskander, Mona N.;Saleh, Mahmoud A.;El-Hagry, Mohsen M.T.
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.575-581
    • /
    • 2009
  • In this paper two modes of operating a wound rotor induction machine as a generator at sub-and super-synchronous speeds in wind energy conversion systems are investigated. In the first mode, known as double fed induction generator (DFIG), the rotor circuit is fed from the ac mains via a controlled rectifier and a forced commutated inverter. Adjusting the applied rotor voltage magnitude and phase leads to machine operation as a generator at sub-synchronous speeds. In the second mode, the machine is operated in a slip recovery scheme where the slip energy is fed back to the ac mains via a rectifier and line commutated inverter. This mode is described as double output induction generator (DOIG) leading to increase the efficiency of the wind-to electrical energy conversion system. Simulated results of both modes are presented. Experimental verification of the simulated results are presented for the DOIG mode of operation, showing larger amount of power captured and better power factor when compared to conventional induction generators.

Digital Control Techniques for Bidirectional CRM Buck/Boost Converter (양방향 경계모드 벅/부스트 컨버터의 디지털 제어기법)

  • Sang-Youn Lee;Woo-Seok Lee;Il-Oun Lee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.28 no.1
    • /
    • pp.48-58
    • /
    • 2023
  • This paper presents the digital control techniques of a bidirectional CRM(critical-conduction mode) buck(boost) converter, a dead-time design method that optimizes ZVS(zero-voltage switching) and valley-switching operation, and a switching-frequency limitation that ensures stable converter operation. To verify the feasibility of the design, a Si-MOSFET-based bidirectional CRM buck(boost) converter is built with 260-430 V input, 160-240 V output, and 1.0 kW rated capacity. The bidirectional CRM converter achieves an efficiency of up to 99.6% at buck mode and 98.7% at boost mode under rated load conditions.

Design of Variable Average Operation without the Divider for Various Image Sizes (다양한 영상크기에 적합한 나눗셈기를 사용하지 않은 가변적 평균기의 설계)

  • Yang, Jeong-Ju;Jeong, Hyo-Won;Lee, Sung-Mok;Choi, Won-Tae;Kang, Bong-Soon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.4
    • /
    • pp.267-273
    • /
    • 2009
  • In this paper, we proposed a variable average operation for a WDR(Wide Dynamic Range). The previously proposed average operation [5] improves hardware efficiency and complexity by replacing divider with multiplier. However, the previously proposed method has some weak-points. For example, there are counting horizontal and vertical length, and then the multiplier selects a Mode set by the user when the lengths exactly correspond with the image's size in the Mode. To compensate some weak-points, we change a Mode selection methods as a using the image's total size. Also, we propose another feature that it can be applied to various image sizes. To get a more accurate average, we add an external compensation value. We design the variable average operation using a Verilog-HDL and confirm that the Serial Multiplier's structure is better efficiency than Split Multiplier's structure.

  • PDF

A Pilot-Scale Microfiltration/Ultrafiltration system for Drinking Water Treatment (상수처리를 위한 파일롯 규모의 정밀여과/한외여과 시스템)

  • Kim, Hanseung;Oh, Jeongik;Kim, Chunghwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.770-777
    • /
    • 2004
  • Three pilot-scale membrane systems were operated using lake water as influent in this study. Microfiltration (MF) membrane with pore size of 0.01 m was used in Systen I of which filtration mode was set at constant pressure of $1kgf/cm^2$. Ultrafiltration (UF) membranes with molecular cutoff (MWCO) of 80,000 and 13,000 were used in System II-1 and II-2, respectively. Constant flow mode was applied at the range between 0.7 and $1.5m^3/m^2{\cdot}d$ (average of $1.1m^3/m^2${\cdot}d) for System II-1 and between 0.37 and $1.65m^3/m^2{\cdot}d$ (average of $1.18m^3/m^2{\cdot}d$) for System II-2. In System I, the flux changed from $1m^3/m^2{\cdot}d$ to $0.2m^3/m^2{\cdot}d$ during the operation time of 5 months. System II showed recovery of 94% under the allowable maximum pressure of $3kgf/cm^2$ during the same operation period. From these results, the efficient operation was observed in constant flow mode with respect to filtration time and recovery. Average filtrate turbidity showed 0.0071 NTU in System I and 0.0054 NTU in System II, which implied that high turbidity removal was obtained in both MF and UF systems with no significant difference between MF and UF. From the fact that membrane flux depends largely on membrane type and operation mode, a guideline of optimum design and operation should be suggested for application of membrane systems to full scale water treatment.

Analysis of Power Supply System for 8.5 MVA Magnetic Power Supply Using EI (EMTDC를 이용한 8.5 MVA급 Magnetic Power Supply의 전력공급 시스템 분석)

  • Jeong, Yong-Hoo;Nho, Eui-Cheol;Kim, In-Dong;Choi, Jung-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1114-1116
    • /
    • 2002
  • The characteristics of voltage drop and THD for parallel operating 11 PCRs (Phase Controlled Rectifiers) are analysed. The PCRs are used to drive high current (1.6 kA ${\sim}$ 3.7 kADC) electromagnetic coils for electromagnets. All the PCRs operate simultaneously in pulsed mode, and the pulse shot occurs every 150 seconds. During the pulse operation the PCR output current ramps up for 4 seconds, and then keeps flat top state for 2 seconds, and finally ramps down for 4 seconds. For the flat top mode a severe voltage drop and distortion appear in the power system because transformers for the PCRs are designed considering pulsed mode operation. It is expected that the analysis method can be applied to improve the system performance including power factor and design of high power pulsed mode operating power supply systems.

  • PDF