• Title/Summary/Keyword: Mode I Loading

Search Result 212, Processing Time 0.033 seconds

Design and Realization of a Digital PV Simulator with a Push-Pull Forward Circuit

  • Zhang, Jike;Wang, Shengtie;Wang, Zhihe;Tian, Lixin
    • Journal of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.444-457
    • /
    • 2014
  • This paper presents the design and realization of a digital PV simulator with a Push-Pull Forward (PPF) circuit based on the principle of modular hardware and configurable software. A PPF circuit is chosen as the main circuit to restrain the magnetic biasing of the core for a DC-DC converter and to reduce the spike of the turn-off voltage across every switch. Control and I/O interface based on a personal computer (PC) and multifunction data acquisition card, can conveniently achieve the data acquisition and configuration of the control algorithm and interface due to the abundant software resources of computers. In addition, the control program developed in Matlab/Simulink can conveniently construct and adjust both the models and parameters. It can also run in real-time under the external mode of Simulink by loading the modules of the Real-Time Windows Target. The mathematic models of the Push-Pull Forward circuit and the digital PV simulator are established in this paper by the state-space averaging method. The pole-zero cancellation technique is employed and then its controller parameters are systematically designed based on the performance analysis of the root loci of the closed current loop with $k_i$ and $R_L$ as variables. A fuzzy PI controller based on the Takagi-Sugeno fuzzy model is applied to regulate the controller parameters self-adaptively according to the change of $R_L$ and the operating point of the PV simulator to match the controller parameters with $R_L$. The stationary and dynamic performances of the PV simulator are tested by experiments, and the experimental results show that the PV simulator has the merits of a wide effective working range, high steady-state accuracy and good dynamic performances.

Seismic Analysis of Tunnel in Transverse Direction Part I: Estimation of Seismic Tunnel Response via Method of Seismic Displacement (터널 횡방향 지진해석 Part I: 응답변위법을 통한 터널의 지진응답 예측)

  • Park, Du-Hee;Shin, Jong-Ho;Yun, Se-Ung
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.6
    • /
    • pp.57-70
    • /
    • 2010
  • Recent earthquakes have demonstrated that the tunnels, which were once considered to be highly resistant to earthquakes, are susceptible to substantial damage under severe seismic loading. Among various modes of deformation under an earthquake loading, the response of the tunnel in the transverse direction is known to be the critical mode. This paper investigates the seismic response of the tunnel in the transverse direction using the method of seismic displacement, which is a type of pseudo-static analysis. Firstly, the methods of calculating the ground deformation are compared. It is shown that the single and double cosine may not provide an accurate estimation of the ground deformation, and that a one-dimensional site response analysis needs to be performed for a more reliable evaluation. Secondly, the tunnel responses are calculated using the simplified, analytical, and numerical solutions. It is demonstrated that the simplified method provides poor estimates of the tunnel response ground deformation. The analytical solution is shown to be effective in modeling circular tunnels in uniform ground, but has serious limitation in modeling tunnel response in non-uniform ground. Numerical analyses are shown to be applicable to all cases, and give the most accurate estimates of the tunnel response. It is also demonstrated that the linear solutions can be so conservative that the soil nonlinearity needs to be accounted for more accurate evaluation of the tunnel response.

Reliability Analysis of Caisson Type Quaywall (안벽구조물의 신뢰성 해석)

  • Yoon, Gil-Lim;Kim, Dong-Hywan;Kim, Hong-Yeon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.5
    • /
    • pp.498-509
    • /
    • 2008
  • Reliability analyses of Level I, II and III for bearing capacity, overturning and sliding of quaywall are carried out to investigate their safety levels depending upon its failure modes, and sensitivity analyses of each design variable are performed to find their effects on safety levels of quaywall. Reliability indices was 1.416 for both level II and III for case study I, and with 2.201 and 1.880, respectively, for the case study II at the critical loading conditions. Thus we were able to know that Level II (FORM) approach is good enough to use in practical design. Generally, it was found that probabilities of failure of quaywall were higher for sliding and bearing capacity failure modes and lower for overturning failure mode. From sensitivity analyses, the most influential design variables to reliability index of quaywall were coefficient of friction, residual water pressure and resistance moment for the sliding, overturning and bearing capacity failure modes, respectively. Especially, the sensitivity of reliability index due to inertial force and dynamic water pressures, which include a large COV when earthquake occurs, did not change greatly.

A Study on Flexural and Shear Behavior of the Structure with Steel Plate Concrete to Reinforced Concrete Member's Connection (철근 콘크리트와 강판 콘크리트 간 이질접합부로 구성된 구조물의 휨 및 전단거동 특성 연구)

  • Hwang, Kyeong Min;Lee, Kyung Jin;Lee, Jong Bo;Won, Deok Hee
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5A
    • /
    • pp.267-275
    • /
    • 2012
  • This paper describes the experimental study on the structural behavior of the joint plane between a RC(Reinforced Concrete) wall and a SC(Steel Plate Concrete) wall under out-of plane flexural loads and in-plane shear loads. The test specimens were produced with L and I shape to assess efficiently flexural and shear behavior of the structures. In order to consider dynamic loads such as earthquake, cyclic loading tests were carried out. As results of the out-of plane flexural tests, ductile failure mode of vertical bars was shown under a push load and the failure load was more than nominal strength of the specimen. And the latter test was performed to verify the variation which was composition presence of horizontal bars in the SC member. The test results showed that capacity of the specimens was more than their nominal strength regardless of composition presence of horizontal bars.

Damage Analysis of Singly Oriented Ply Fiber Metal Laminate under Concentrated Loading Conditions by Using Acoustic Emission (음향 방출법을 이용한 집중하중을 받는 일방향 섬유 금속 적층판의 손상 해석)

  • 남현욱;김용환;한경섭
    • Composites Research
    • /
    • v.14 no.5
    • /
    • pp.46-53
    • /
    • 2001
  • In this research, damage behavior of singly oriented ply (SOP) fiber metal laminate (FML) subjected to concentrated load was studied. The static indentation tests were conducted to study fiber orientation effect on damage behavior of FML. During the static indentation tests, acoustic emission technique (AE) was adopted to study damage characteristics of FML. AE signals were obtained by using AE sensor with 150kHz resonance frequency and the signals were compared with indentation curves of FML. The damage process of SOP FML was divided by three parts, i.e., crack initiation, crack propagation, and penetration. The AE characteristics during crack initiation show that the micro crack is initiated at lower ply of the plate, then propagate along the thickness of the plate with creating tiber debonding. The crack grow along the fiber direction with occurring 60∼80dB AE signal. During the penetration, the fiber breakage was observed. As fiber orientation increases, talc fiber breakage occurs more frequently. The AE signal behaviors support these results. Cumulative AE counts could well predict crack initiation and crack propagation and AE amplitude were useful for the prediction of damage failure mode.

  • PDF

Fracture Mechanics Analysis of the Weldment in Pulley for Belt Conveyor (컨베이어용 풀리의 용접부위에 관한 파괴역학 설계기술 개발)

  • Han, Seung-U;Lee, Hak-Ju;U, Chang-Su;Lee, Sang-Rok
    • 연구논문집
    • /
    • s.23
    • /
    • pp.127-140
    • /
    • 1993
  • The drive pulley, which is employed for loading and unloading raw materials in a steel mill, is usually manufactured by use of various welding processes. In this study the weldment in the pulley, in which TIG and $CO_2$ welding processes are used, has been analyzed from view point of fracture mechanics. Fracture toughness tests have been performed according to ASTM E813. A servo-hydraulic testing machine (10kN) has been employed. Also the crack propagation tests (Mode I) have been performed with compact tension specimen in compliance with ASTM E647. To predict the critical crack size in the weldment, finite element stress analysis for the drive pulley under real operating conditions have been performed. In addition, the residual stresses at the weldment and in heat-affected zone have been obtained by hole drilling method. The planar critical crack size have been predicted for the drive pulley by considering the stress analysis results and the residual stresses due to welding process. For the drive pulley considered in this study, it has been concluded that the most important factor in determining the critical crack size is the welding residual stress in the transverse direction. Also the effect of stress concentration at the root of the weldment have been noticeable. For the planar crack, the fatigue crack growth life from an initial crack size of 2mm to the critical crack size obtained as in the above have been predicted. The predicted lives were between 55, 900 and 72, 000 cycles depending on the shape of the elliptical crack. The predicted lives were in fairly good agreement for the drive pulley considered in this study.

  • PDF

A Study of Bearing Strength on Composite Pinned-Joint at Low Temperature (저온환경에서 복합재료 핀 연결부의 Bearing 강도에 관한 연구)

  • Her, N.I.;Lee, S.Y.;Kim, J.H.;Lee, Y.S.;Sa, J.W.;Cho, S.;Im, K.H.;Oh, Y.K.;Choi, C.H.;Do, C.J.;Kwon, M.;Lee, G.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.413-418
    • /
    • 2001
  • Fundamental failure mode in a laminated composite pinned-joint is proposed to assess damage resulting from stress concentration in the plate. The joint area is a region with stress concentrations thus a complicated stress state exists. The modeling of damage in a laminated composite pinned-joint presents many difficulties because of the complexity of the failure process. In order to model progressive from initial to final, finite element methods are used rather than closed form stress analyses. Failure analysis must be a logical combination of suitable failure criteria and appropriate material properties degradation rules. In this study, the material properties which were obtained in previous study, the preparing process of the bearing strength test for a pinned joint CFRP composite plate subjected to in-plane loading at low temperature, and the FEM result of progressive damage model using ANSYS program are summarized to assess the structural safety of CFRP plate used in the magnetic supporting post of KSTAR(Korea Superconducting Tokamak Advanced Research).

  • PDF

Numerical Analysis of Thermal Effect on Axial Load and Pile Settlements in PHC Energy Piles (PHC 에너지파일의 열응력에 따른 축하중-침하 수치해석)

  • Lee, Dae-Soo;Min, Hye-Sun;Lim, Hyun-Sung;Jeong, Sang-Seom
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.5
    • /
    • pp.5-17
    • /
    • 2013
  • This study investigates the effect of thermal stress on axial load and pile settlement of PHC energy piles. A series of numerical analyses were performed by controlling major influencing parameters such as pile arrangement, pile spacing, end-bearing condition, soil condition and pile cap stiffness. It is found that the characteristics of pile-load transfer are significantly affected by seasonal operation mode (i.e., cooling and heating) throughout the year. Also, the axial load under thermal loading increases with increasing the pile spacing. The settlement of the pile in sand is larger than that in clay because of the thermal stress generated. It is also found that thermal stress highly influences on the end-bearing pile, corner pile and rigidity of pile cap.

Ductile Fracture Predictions of High Strength Steel (EH36) using Linear and Non-Linear Damage Evolution Models (선형 및 비선형 손상 발전 모델을 이용한 고장력강(EH36)의 연성 파단 예측)

  • Park, Sung-Ju;Park, Byoungjae;Choung, Joonmo
    • Journal of Ocean Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.288-298
    • /
    • 2017
  • A study of the damage evolution laws for ductile materials was carried out to predict the ductile fracture behavior of a marine structural steel (EH36). We conducted proportional and non-proportional stress tests in the experiments. The existing 3-D fracture strain surface was newly calibrated using two fracture parameters: the average stress triaxiality and average normalized load angle taken from the proportional tests. Linear and non-linear damage evolution models were taken into account in this study. A damage exponent of 3.0 for the non-linear damage model was determined based on a simple optimization technique, for which proportional and non-proportional stress tests were simultaneously used. We verified the validity of the three fracture models: the newly calibrated fracture strain model, linear damage evolution model, and non-linear damage evolution model for the tensile tests of the asymmetric notch specimens. Because the stress evolution pattern for the verification tests remained at mode I in terms of the linear elastic fracture mechanics, the three models did not show significant differences in their fracture initiation predictions.

Reliability Analysis of a Quay Wall Constructed on the Deep-Cement-Mixed Ground(Part I: External Stability of the Improved Soil System) (심층혼합처리지반에 설치된 안벽의 신뢰성해석(Part I: 개량지반의 외부안정))

  • Huh, Jung-Won;Park, Ock-Joo;Kim, Young-Sang;Hur, Dong-Soo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.22 no.2
    • /
    • pp.79-87
    • /
    • 2010
  • This is the first of the two papers dealing with reliability analyses for external and internal stability of a quay wall constructed on a special foundation. A new practical reliability analysis method is proposed in this paper to evaluate the quantitative risk associated with external stability of a quay wall constructed on the deep cement mixed ground. The method can consider uncertainties in various design variables. For the risk estimation to external stability of the improved soil-quay wall, three corresponding limit state functions of sliding, overturning and bearing capacity are fully defined by introducing concept of the secondary random variable. Three representative reliability methods, MVFOSM, FORM and MCS are then applied to evaluate the failure probabilities of the three limit state functions explicitly expressed in terms of the basic and secondary random variables. From the reliability analysis results, the failure probabilities obtained from the three approaches are very close to each other, and the sliding failure mode appears to be the most critical when the earthquake loading is under consideration.