• Title/Summary/Keyword: Mode 3 services

Search Result 114, Processing Time 0.019 seconds

Financial performance analysis based on efficiency evaluation of Regional Public Hospital (지방의료원의 운영효율성 평가에 따른 재무성과 분석)

  • Lee, Jin-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.614-623
    • /
    • 2017
  • The purpose of this study is to analyze the impact of the financial performance of regional public hospitals on their efficiency. In addition, the analysis of their efficiency using environmental factors, such as the market share, operating mode, and size of the regional public hospitals, as well as the factors influencing their efficiency, are selected by selecting the input and output factors of the hospitals and some differences were found between them. The DEA index and financial performance of the 31 regional public hospitals were calculated for the three years from 2012 to 2014. ANOVA and hierarchical regression analysis were used. As a result, there was a significant difference in their efficiency according to the environmental factors, such as the city scale of the regional public hospital, the number of hospital beds, and their business performance, productivity, and publicness. The medical profit margin (p<0.05), labor cost investment efficiency (p<0.05) and HHI (p<0.05) were found to affect the efficiency. In order to identify the inefficiencies of the regional public hospitals and increase their efficiency, it is necessary to measure the efficiency of the input resources and to reduce their cost. In addition, if the regional public hospitals were to provide specialized services, such as specialized functions of medical care that would give them a competitive advantage over private hospitals, their operational efficiency would be enhanced and they would be able to fulfill their role as public medical institutions.

KTX Impact on the Inter-Regional Transportation System (고속철도 개통후 지역간 교통체계의 변화)

  • Lee, Jin-Seon;Kim, Gyeong-Tae
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.2
    • /
    • pp.75-82
    • /
    • 2005
  • To relieve congestion in the current system of intercity transportation, the Korea decided in 1990 to construct a high-speed railroad between Seoul and Busan and it is now in operation. This new mode of transportation significantly cut travel time between major cities and a trip from Seoul to the southeastern port of Busan. Since the KTX opening, average daily passenger numbers on both the Gyeongbu and Honam lines have increased about 1.3 fold over 2003 levels. As of December 2004, the KTX trains are carrying about 81,000 people a day. On KTX routes, the daily number of airline passengers dropped. Express long-distance bus traffic also dropped by 20% to 30%, while that on short-distance routes (100km or less) increased by about 20%. These figures clearly indicate that the Korean transportation network is becoming railroad-centric. However, the number of KTX passengers is fewer than anticipated possibly due to the Korean economic downturn and the operation of the KTX will leave many existing Saemaul and Mugunghwa train sets idle, which will be put into operation for areas, not covered by the KTX. When all the existing major lines have been electrified, more high-speed rail services will be phased in using direct connections to maximize operational efficiency. And also, the dual management by KTX and conventional rail will be regarded as the promotion of the benefit of the public.

Inhibitory Effects of PLM-WE1 Formulated from Extract of Phellinus linteus Mycelium against Plant Viruses Infection and Identification of Active Compound (목질진흙버섯(Phellinus linteus) 균사체 추출물 제제 PLM-WE1의 식물 바이러스에 대한 감염억제 효과 및 활성성분의 동정)

  • Kwon, Soon-Bae;Bae, Seon-Hwa;Choi, Jang-Kyung;Lee, Sang-Yong;Kim, Byung-Sup;Kwon, Yong-Soo
    • Research in Plant Disease
    • /
    • v.16 no.3
    • /
    • pp.259-265
    • /
    • 2010
  • Pepper mild mosaic virus(PMMoV) and Cucumber mosaic virus (CMV) are important pathogens in various vegetable crops worldwide. We have found that hot water extract of Phellinus linteus mycelium strongly inhibit PMMoV and CMV infection. Based on these results, the inhibitor named as 'PLM-WE1' formulated from extract of Phellinus linteus mycelium was tested for its inhibitory effects on PMMoV and CMV infection to each local lesion host plant (Nicotiana glutinosa: PMMoV, Chenopodium amaranticolor: CMV). Pretreatment effect of PLM-WE1 against infections of each virus (PMMoV and CMV) to local host plant was measured to be 99.2% to PMMoV and 80.3% to CMV, and its permeability effect was measured to be 45.0% to PMMoV and 41.9% to CMV. Duration of inhibitory activity of PLM-WE1 against PMMoV infection on N. glutinosa was maintained for 3 days at 75% inhibition level and CMV infection on C. amaranticolor maintained for 3 days at 62% inhibition level. Inhibitory effects on systemic host plants of PLM-WE1 were measured to be 75~85% to PMMoV and 75% to CMV. Under electron microscope, PMMoV particles were not denatured or aggregated by mixing PLM-WE1. It is suggested that the mode of action of PLM-WE1 differ from that of inactivation due to the aggregation of viruses. The methanol extract of P. linteus mycelium was sequentially partitioned with haxane, ethyl acetate, BuOH and $H_2O$. The $H_2O$ fraction was showed high activity than the other fractions. The active compound was isolated with a partial acid hydrolysis, fractional precipitation with ethanol. The inhibitory effect of the precipitate isolated from 70% ethanol fraction was 99.1% to PMMoV and 88.0% to CMV. The structure of isolated compound was determined by $^1H$-NMR and $^{13}C$-NMR. This compound was identified as a polysaccharide consisting alpha or beta-glucan.

A Study on Mobile Antenna System Design with Tri-band Operation for Broadband Satellite Communications and DBS Reception (광대역 위성 통신/방송용 삼중 대역 이동형 안테나 시스템 설계에 관한 연구)

  • Eom Soon-Young;Jung Young-Bae;Son Seong-Ho;Yun Jae-Seung;Jeon Soon-Ick
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.5 s.108
    • /
    • pp.461-475
    • /
    • 2006
  • In this paper, it is described about the tri-band mobile antenna system design to provide broadband multimedia and direct broadcasting services using goo-stationary Koreasat 3, simultaneously operated in Ka/K/Ku band. The radiating part of the antenna system with a fan beam characteristic in the elevation plane is composed of the quasi-offset dual shaped reflector and the tri-band feeder. The tri-band feeder is also composed of the Ka/K dual band feeder with the protruding dielectric rod, the circular polarizer, the ortho-mode transducer and the circular-polarized Ku band feed array. Especially, the Ka/K dual band circular polarizer was realized firstly using the comb-type structure. For fast satellite-tracking on the movement, the Ku band feed array has the structure of the $2{\times}2$ active phased array which can make electrical beams. And, the circular-polarized characteristic in the feed array was improved by $90^{\circ}$ rotating arrangement of four radiating elements polarized circularly by a $90^{\circ}$ hybrid coupler, respectively. Four beam forming channels to make electrical beams at Ku band are divided into the main beam channel and the tracking beam channel in the output, and noise temperature characteristics of each channel were analyzed on the basis of the contributions of internal sub_units. From the fabricated antenna system, the output power at $P_{1dBc}$ of Ka_Tx channel was measured more than 34.1 dBm and the measured noise figures of K/Ku_Rx channels were less than 2.4 dB and 1.5 dB, respectively, over the operating band. The radiation patterns with co- and cross-polarization in the tri-band were measured using a near-field measurement in the anechoic chamber. Especially, Ku radiation patterns were measured after correcting each initial phase of active channels with partial radiation patterns obtained from the independent excitation of each channel. The antenna gains measured in Ka/K/Ku band of the antenna system were more than 39.6 dBi, 37.5 dBi, 29.6 dBi, respectively. And, the antenna system showed good system performances such as Ka_Tx EIRP more than 43.7 dBW and K/Ku_Rx G/T more than 13.2 dB/K and 7.12 dB/K, respectively.