• 제목/요약/키워드: Mock-up experiment

검색결과 97건 처리시간 0.02초

Mock-up모델을 이용한 황토 및 시멘트의 환경요소 평가 연구 (Mock-up Model of the Environment Assessment Study on Red-clay and Cement)

  • 최율;송현근
    • KIEAE Journal
    • /
    • 제11권2호
    • /
    • pp.91-96
    • /
    • 2011
  • The purpose of this study is to measure the environmental effects of different alternative building materials. The following building materials were tested: clay bricks, cement wall, and red-clay plaster. Four mock-up models were constructed using clay bricks, cement wall, red-clay plaster and the last model as the control model. The effects of the above four building materials on temperature, humidity, the emissions of formaldehyde, and V.O.C were measured. This experiment was conducted during September. The conclusions are as follows. Clay bricks were able to control temperature, humidity and filter formaldehyde by itself. The environment within the cement wall was not affected by the humidity changes outside. Red-clay plaster walls had little impact on the environment because it is very thin.!

구획화재실험을 통한 온도 변화 예측 기법 연구 (The Study on the Prediction of Temperature Curve by Compartment Fire Experiment)

  • 권오상
    • 한국화재소방학회논문지
    • /
    • 제28권5호
    • /
    • pp.44-51
    • /
    • 2014
  • 본 연구에서는 건축물에서의 성능기반 화재안전 설계 시에 사용되는 구획공간에서의 화재 성상 분석을 위해서 사무실 공간을 대상으로 하여 $2.4(L){\times}3.6(W){\times}2.4(H)m$의 크기의 구획 Mock-up을 제작하고 구획 내부에는 화재하중 $18.74kg/m^2$을 적용하여 책상, 의자, 컴퓨터 등과 같은 실제 가연물을 배치하여 화재실험을 실시하였다. 화재실험 결과, 구획 공간의 내부 중앙에서는 394~408 s 사이에 $600^{\circ}C$에 도달하였고 구획 입구 모서리에서는 404~420 s 사이에 $600^{\circ}C$에 도달하였다. 본 연구에서는 화재실험을 통해 측정된 온도변화 데이터를 BFD 곡선에 적용하여 화재시 구획 공간내의 온도변화 예측 기법을 분석하고자 하였으며, 화재실험을 통해 BFD 곡선 인자는 최대온도 $900^{\circ}C$, 최대온도 도달시간 7분과 형태계수 1.5로 결정하였다. BFD 곡선에 적용된 사무실 공간의 시간에 따른 온도 곡선은 화재초기에 빠르게 상승한 이후에 약 9분경 이후에 감소하는 형태를 나타내고 있다.

첨단채광시스템 실험용 Mock-Up 모형의 형상 및 모니터링 프로토콜 시스템에 관한 비교분석 - IEA SHC Task21을 중심으로- (Comparative Analysis on the Mock-ups' Configuration and Monitoring Protocol System of Advanced Daylighting Systems for Daylighting Experiment - Focused on IEA SHC Task21-)

  • 정인영;최상현;김정태
    • KIEAE Journal
    • /
    • 제4권1호
    • /
    • pp.11-20
    • /
    • 2004
  • Innovative daylighting systems in buildings in various climatic zones around the world have been developed under the IEA SHC Task21. The performance assessment were obtained by monitoring the most systems using full-scale test model rooms or actual buildings under real sky conditions. This study aims to analyze the configuration and monitoring system of the nine Mock-up models of the IEA SHC Task21 comparatively. For the purpose, the geometry of the test rooms (length, width, height, window area, glazed area and occupied), reflectance of walls, floor and ceiling, transmittance of glazing (transmittance for hemispherical irradiation, normal irradiation and U-value) were compared. And equipment for measurement (manufacturer, range, calibration, maximum calibration error, cosine response error, fatigue error), and data acquisition system (manufacturer, type, number of differential analogue input channels, A/D converter resolution in bits, data acquisition software) were also analyzed comparatively. Some findings of these experimental methodology of standard monitoring have been proven to be a valuable one for future assessment of advanced daylighting systems in our country.

건축실내 인공조명의 불쾌글레어 평가실험에 적용된 실험변수의 민감도 분석에 관한 연구 (Study on Sensitivity of Variables of the Experiment to Evaluate Discomfort Glare of Interior Artificial Illumination)

  • 이진숙;김원도;김창순
    • 조명전기설비학회논문지
    • /
    • 제22권1호
    • /
    • pp.24-32
    • /
    • 2008
  • 본 연구에서는 한국인의 시각적 특성을 반영한 불쾌글레어의 합리적인 예측을 위해 국내에 실제적으로 적용 가능한 불쾌글레어 예측식을 작성하는 것이 최종목표로 하고 있으며, 본 논문에서는 주변의 일반적인 사무실 건물의 조명환경을 대상으로 기본 단위로 구획하여 실물대모형(Mock-up)을 제작하여 실험을 진행하고 글레어에 최대 영향요인인 광원휘도를 비롯한 배경휘도, 입체각, 광원면적, 루버종류와 불쾌글레어의 관계를 도출하는 것을 목적으로 하였다. 본 연구는 다음과 같이 4단계로 나누어 연구를 진행하였다. 첫째, 불쾌글레어 평가등급을 정의하고 분류하기 위하여 선행연구에서 사용된 평가등급을 조사하여 연구목적에 부합되도록 수정하여 실험에 적용할 수 있도록 하였다. 둘째, 기존 불쾌글레어 평가실험식에 대한 검토를 통해 실험변수, 변수범위, 평가대상, 평가내용 등을 선정하였다. 셋째, 연구의 목적에 부합되도록 실험변인을 조절할 수 있는 실물대모형(Mock-up)을 제작하여 불쾌글레어 평가실험을 실시하였다. 최종적으로 불쾌글레어감과 광원휘도, 루버종류, 광원면적, 피험자위치간의 관계분석을 통해 실험변수의 민감도를 분석하였다. 연구 결과 인공광원의 불쾌글레어감에 영향을 주는 주요 변수는 광원휘도, 루버의 유무, 광원면적, 피험자위치(입체각) 순으로 영향을 미치는 것으로 나타났다.

이산화티탄 광촉매 환기장치의 오염물질 저감 실험 (Experiment on Reduction of Pollutants in Titanium Dioxide Photocatalytic Ventilation System)

  • 송용우
    • 토지주택연구
    • /
    • 제13권2호
    • /
    • pp.117-123
    • /
    • 2022
  • 본 연구는 대표적인 미세먼지와 실내유해물질인 질소산화물의 저감을 위해 이산화티탄 광촉매를 환기장치에 적용한 것으로 그 내용은 다음과 같다. 기존 연구는 실내에 자외선 적용의 한계로 인해 주로 건축자재에 광촉매 혼입을 통해 실외 자재를 대상으로 진행되었다. 자외선 실내 적용 한계를 극복하고자 기존 선행연구를 통해 확인된 이산화티탄 광촉매의 오염물질 분해 효과를 실내에 적용이 가능하도록 자외선램프의 설치가 가능한 반응장치를 설계 및 제작하였다. 해당 반응장치를 실내 환기장치에 적용하여 Mock-Up에 적용하였다. Mock-Up 실험은 그 체적을 시간당 1회, 5회 환기하는 풍량을 변화시켜 NOx 저감 성능을 확인하였다. 그 결과, 환기 풍량이 증가함에 따라 NOx 저감시간이 비례하여 감소되어 그 성능이 증가하는 것을 확인하였다. 해당 연구를 통해 오염물질 저감 효과를 가진 이산화티탄 광촉매의 실내 활용 방안과 그 성능을 확인할 수 있는 기초적인 연구 결과를 도출하였다.

재료 융합 단계와 임시 스트럿의 경계조건을 이용한 기둥-보 강결 구조물의 효율적인 거동 연구 (A Study for Efficient Behavior of Beam-column Joint Structure Using Material Convergence Section Stage and a Temporary Boundary Condition by Strut)

  • 조재형;송재호
    • 한국산업융합학회 논문집
    • /
    • 제23권2_2호
    • /
    • pp.361-374
    • /
    • 2020
  • Recently, small and medium-sized rahmen-type bridges have been developed as a technology that ensures the stability of structural behavior and the safety of use at the same time by using efficient and economical materials that make up the convergence section of reinforced bar, structural steel and concrete. This study is about a rahmen-type structure applied with the installation and dismantling of the strut. It improves the serviceability of the structure by forming multi-points and efficiently applies the convergence section of structural steel and concrete materials to the structural system changes to induce the displacement improvement effect additionally. By constructing mock-up models for the beam-column joint, the displacement was calculated and compared, and this was compared and analyzed by numerical analysis. The final displacement showed an improvement effect of 13.46% to 36.28% based on the vertical displacement of the existing structure without struts through the experiment of the mock-up models. As a result of analysis by numerical analysis method, the displacement improvement effect of 42.89% could be derived.

광선반 채광시스템의 시각적 성능 평가 (Visual Performance Evaluation of Daylighting System with Sloped Lightshelves)

  • 김정태;심인보
    • KIEAE Journal
    • /
    • 제6권2호
    • /
    • pp.3-10
    • /
    • 2006
  • This study assessed the visual performance of luminous environment by the lightshelf. The subject survey method was used and results are presented and analyzed. The lightshelf daylighting system was developed by LAEL at KH University and was applied on the window of a mock-up office. The questionnaire for assessing visual performance contains 9 questions with 7 grade bipolar scales. The experiment was conducted during the bright part of the day from noon to one thirty on June 7, 2006. The questionnaire for assessing visual performance contains 9 questions with 7 grade bipolar scales. During the experiment was carrying out, the work plane illuminance and luminous distribution at surrounding the windows was measured. The semantic differential rating data of experiment were analyzed by t-test and factor analysis using SPSS 12.0 statistics package. The visual performance of the lightshelf was more positive. The factors affecting the visual performance are task performance and visual comfort. The subjects were more comfortable in a room installed with lightshelves on both the task performance and the visual comfort aspect. Therefore, the application of sloped lightshelf daylighting system improves visual performance of luminous environment.

Mock-up을 이용한 일반창호 및 경사형 광선반 창호의 채광성능에 관한 비교 실험 (Comparative Daylighting Performance of an Interior with Lightshelves and Conventional Glazing; A Mock-Up Experiment)

  • 김정태;신화영
    • KIEAE Journal
    • /
    • 제6권2호
    • /
    • pp.67-74
    • /
    • 2006
  • As sustainable design technologies, advanced daylighting systems with lightshelves have been developed and are currently under monitoring the daylighting performance. This study aims to evaluate the comparative daylighting performance of sloped lightshelf and conventional glazing window with mock-up model, reconstructed as a prototype of Korean office building, sized $12.0m{\times}7.3m{\times}3.7m$ ($w{\times}d{\times}h$) and $1.8m{\times}4.8m$($w{\times}h$) for the south facing side-window was installed on the rooftop of engineering building, Kyung Hee University in Korea. It has an identical configuration of reference room and the test room. For the test room, the sloped type lightshelf system was designed as 10mm transparency sheet glass, tilt angle degree $29^{\circ}$, and total sized 1.28m (interior length 0.88m, exterior length 0.49m). It consisted of daylighting collector, entrance glazing and reflector. To assess daylighting performance, the totally 37 measuring points for illuminance and 2 view points of luminance were monitored in every 30 minutes from 12:00 to 15:00. For the detailed analysis, photometric sensors of each room were installed at work-plane (8 points), wall (7 points), ceiling (3points), and exterior horizontal illuminance (1 point). Luminance of window, rare of the room was measured under clear sky. It is to be monitored by Agilent data logger, photometric sensor Li-cor and the Radiant Imaging ProMetric 1400. Comparisons with a light factor, increase-decrease ratio, uniformity, and luminance are discussed.

고강도-고성능 콘크리트의 모의 부재 및 실대 구조물 시공 실험 (An Constructive Experiment through Mock-up and Monolith of High-Strength High-Performance Concrete)

  • 김태영;이영호;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.357-364
    • /
    • 1997
  • In this experiment high-strength concrete of good workability is made by means of either replacing unit cement quantity to fly-ash by 20% or using low heat cement to reduce the internal hydration heat suggested as the fault of concrete. Concrete is poured through ready mixed concrete to test the ability of applying to the substantial works and is carried out the test of flowing and core strength and record of temperature of imitating specimens. It is capable to apply high-strength concrete replaced to fly-adh 20% to the substantial works through the experiment

  • PDF

유화처리 정제식용유를 사용한 고성능 콘크리트의 자기수축 Mock-up 실험 (Autogenous Shrinkage Mock-up Test of High Performance Concrete by Emulsified Refined Cooking Oil)

  • 조만기;한천구
    • 한국건설순환자원학회논문집
    • /
    • 제4권3호
    • /
    • pp.307-315
    • /
    • 2016
  • 본 연구에서는 CFT에 사용하는 70 및 100MPa급 고강도 콘크리트의 ERCO 적용 유무에 따른 기초적 물성 및 강도특성을 분석하고, Mock-up 시험을 통해 자기수축 저감성능 및 활용성을 검토하고자 하였는데, 그 결과 굳지않은 콘크리트의 유동특성으로 ERCO를 사용함에 따라 슬럼프 플로는 약간 저하하는 경향을 나타내었으나, 슬럼프는 증가하였고, 재료분리 저항성(EIS)은 2.5 이하로 양호하게 나타났다. 공기량의 경우는 모두 목표범위를 만족하는 것으로 나타났는데, 단위용적질량은 증가하였으며, 응결시간은 약간 지연되는 것으로 나타났다. 강도 특성의 경우 ERCO를 0.5% 사용함에 따라 호칭강도 별 모든 배합에서 ERCO 0%에 비해 약 5~10%정도의 높은 압축강도 발현율을 나타내었다. 자기수축 특성은 전반적으로 ERCO를 사용한 배합의 경우 사용하지 않은 배합에 비해 20~30%정도 높은 자기수축저감 성능을 나타내었는데, 이는 ERCO의 주성분인 지방산($C_3H_5(OCOR)_3$)이 콘크리트 경화체중 수화생성물인 수산화칼슘($Ca(OH)_2$)에 가수분해 되어지방산칼슘(2RCOOCa), 즉 비누입자를 생성시켜, 콘크리트 경화체 내부의 모세관 공극을 충전함으로써 자기수축이 저감된 것으로 분석된다. 종합적으로 ERCO를 사용한 70 및 100MPa 고성능 콘크리트는 유동성 및 강도를 충분히 확보하였고, 자기수축 저감에도 효과적인 것으로 나타나, 이를 CFT 실구조체에 타설하는 것으로 결정하였다.