• 제목/요약/키워드: Mock-Up Specimen

검색결과 50건 처리시간 0.022초

In-Situ Application of High-Strength Antiwashout Underwater Concrete

  • 문한영;송용규
    • 콘크리트학회논문집
    • /
    • 제16권2호
    • /
    • pp.283-291
    • /
    • 2004
  • Recently, the construction of underwater structures has been gradually increased, but underwater concrete got some problems of quality deterioration and water contamination around cast-in-situ of construction. In addition, massive underwater structures such as LNG tank, underwater concrete structures of large and continuous high- strength subterranean wall under water are being demanded lower heat of hydration. In this paper, the mechanical properties of high-strength antiwashout underwater concrete (HAWC) containing with two kinds of mineral admixtures respectively were investigated. On the basis of these results, the pH value and suspended solids of HAWC manufactured in the mock-up test were 10.0$\Box$11.0 and 51 mg/${\iota}$ at 30 minutes later, respectively, initial and final setting time were about 30,37 hours, and the slump flow was 530$\pm$20Tm. In the placement at a speed of $27 m^3/hr$, there was no large difference in flowing velocity with or without reinforcing bar, and flowing slope was maintained at horizontal level. Compressive strength and elastic modulus of the cored specimen somewhat decreased as flowing distance was far; however, those of central area showed the highest value.

폴리론 화이버를 혼입한 고강도 RC 보 및 슬래브의 내화특성 분석을 위한 Mock-Up 실험 (Mock-Up Test for the Fire Resistance Analysis of High Strength RC Beam and Slab Using the Polylon Fiber)

  • 손호정;황동규;한창평;한민철;양성환;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2009년도 추계 학술논문 발표대회
    • /
    • pp.93-96
    • /
    • 2009
  • The objective of this study is to analyze the insulation characteristics of the polylon hybrid fiber inserted high-strength RC beam and slab produced as a single body and the results of this study can be summarized as follows. In the spalling mechanism as an insulation characteristic, the slab of the single body type specimen shows an exposure in concrete covers at the center of slab and that leads to the spalling, which exposures reinforcing bars. In the case of the beam, the spalling was presented at several sections as a type of peel spalling before and after 10 minutes from the insulation test. Whereas, although the internal temperature history of concrete represents the highest range as 581℃ in the case of the center of the bottom of beam base, it can be considered that it satisfies the regulation of insulation certification.

  • PDF

모의 시험편에 대한 TOFD와 방사선투과시험의 비교 (Comparison of TOFD and Radiographic Testing for a Mock-up Specimen)

  • 김중직;전종건;김진택
    • 비파괴검사학회지
    • /
    • 제28권1호
    • /
    • pp.64-69
    • /
    • 2008
  • 압력용기 및 구조물 용접부의 내부결함을 검출하기 위해서는 방사선투과시험과 초음파탐상시험을 시행한다. 그러나 방사선투과시험은 방사선 노출 위험성과 필름 현상처리 소요 등으로 결과의 확인에 상대적으로 긴 시간이 소요되어 제작 공정에 영향을 준다. 일반적인 수동 초음파탐상시험은 결과의 재현이 용이하지 않으며 검사자의 기량에 대한 의존도가 높다는 문제점을 가지고 있다. 이에 대한 대안으로 자동 초음파탐상시험 기법의 하나인 TOFD의 적용이 확산되고 있다. 본 연구는 결함을 포함한 시험편에 대하여 방사선투과 시험과 TOFD 기법을 적용하고 비교한 결과를 기술하였다. TOFD 기법은 초음파 시험기법의 객관적 신뢰도 향상에 기여하게 될 것으로 판단된다.

혼화제를 사용한 공동주택 바닥마감 모르타르의 균열저감에 관한 연구 (A Study on the Crack Prevention of the Floor Surface Finishing Mortar adding Chemical Admixtures in Apartment Houses)

  • 이동운
    • 한국산학기술학회논문지
    • /
    • 제16권2호
    • /
    • pp.1541-1548
    • /
    • 2015
  • 본 연구에서는 공동주택 바닥미장 모르타르의 균열을 저감하기 위하여 균열 방지제, 고성능 감수제, 수지 등의 재료혼입에 따른 균열촉진실험을 실시하였다. 그 결과 고성능 감수제와 수지를 혼입한 시편이 균열방지제를 사용한 시편보다 균열수와 압축강도에서 더 우수한 결과를 나타내었다. 그리고 가장 높은 압축강도를 나타낸 시편이 상대적으로 매우 적은 균열을 나타냈으며, 가장 낮은 압축강도를 나타낸 시편에서 많은 균열을 관찰할 수 있었다. 그러므로 압축강도가 우수한 시편이 균열 저항성도 우수한 것으로 나타나 압축강도와 균열저항성은 비례하는 것으로 측정되었다. 모의부재 실험을 바탕으로 실제 아파트 현장에 적용된 배합 3의 장기 모니터링 결과, 장기 재령에서 균열발생이 전혀 관찰되지 않았다.

전단파 토모그래피를 활용한 철도 콘크리트 궤도 슬래브 층분리 결함 평가 (Evaluation of Debonding Defects in Railway Concrete Slabs Using Shear Wave Tomography)

  • 이진욱;기성훈;이강석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권3호
    • /
    • pp.11-20
    • /
    • 2022
  • 이 연구의 주요 목적은 고속철도 콘크리트 궤도 슬래브의 콘크리트 슬래브(track concrete layer, TCL)와 도상안정층(hydraulically stabilized based course, HSB) 사이 층분리를 평가하기 위한 비파괴검사법으로 전단파 토모그래피 기술의 활용가능성을 실험적으로 확인하는 것이다. 이를 위하여 다채널 전단파 측정 장치(MIRA)를 활용하여 실물 크기로 제작된 고속철도 콘크리트 궤도 슬래브 실험체 내부의 층분리 결함을 평가하였다. 실물실험체는 Rheda 2000 시스템에 따라 설계 및 시공되었으며, 노반 위에 HSB를 타설하고, 그 위에 TCL이 타설된 2층 슬래브 구조를 갖는다. 실물실험체는 일부구간의 HSB상부에 스티로폼으로 제작된 인공결함(가로 및 세로가 각각 400mm이고 두께가 각각 5mm, 15mm인 압출폴리스티렌폼(XPS)보드 2개)을 삽입하여, TCL과 HSB 사이에 층분리 결함이 생기도록 시공하였다. 시험체의 층분리 구간에서 얻은 콘크리트 단층이미지는 층분리에 따른 균열 및 HSB와 지반사이의 계면에서 반사되는 신호를 효과적으로 보여 주었다. 한편 초음파 토모그래피 이미지에서 TCL 콘크리트의 매입물(철근, 트러스, 인서트 등)에서 반사된 신호와 층분리 결함 신호를 구분하기 위한 노이즈 제거를 위한 이미지 처리방법을 적용하여 층분리 결함을 효과적으로 분리하였다. 토모그래피 이미지에서 추출된 층분리 결함의 크기정보와 공간정보를 통합하여 층분리 지도로 재구성하였으며, 층분리 결함의 위치 및 크기를 시각화하는데 효과적인 것을 확인하였다.

한국형 전술차량 방탄유리 환경 및 방호력 시험 적용 기법 연구 (A Study of Environment & Bullet-Proof Capability Test Method for KLTV's Transparent Armour)

  • 박진원;박영찬;김선진
    • 한국군사과학기술학회지
    • /
    • 제21권1호
    • /
    • pp.69-73
    • /
    • 2018
  • Korean-peacekeeper's transparent armors in Iraq showed delamination, cracking and clouding a decade ago. And there were also similar deterioration recurrences in KLTV during the operational test a few years ago. Also, the differences between operational capability & lab Bullet-proof test condition, and insufficiency of military protection spec resulted in incomplete bullet-proof results. Moreover, although so many ground weapon systems have been developed, there were not secure test & evaluation codes to verify transparent armoured glasses equal to advanced-overseas products. So in this study, first, environmental test codes were established that all tests should be carried out as the application of only one specimen with newly adopted thermal shock test instead of completing each test with different one. Second, protection standards were integrated through the analysis of global developed country's specifications and reinforced as adding to the real mock-up condition if vehicle's glasses are smaller than standard specimen. Hereby, by applying to test-codes which including actual operational & vehicular conditions, the gap between development test and operational environment was minimized.

확대기초의 신구 콘크리트 접합 모형실험 (Mock-Up Test for Connection of New-Old Concrete of Footing)

  • 황철성;유성원
    • 한국건설순환자원학회논문집
    • /
    • 제6권1호
    • /
    • pp.66-71
    • /
    • 2018
  • 일반적으로 소구경 말뚝을 이용한 기존교각의 확대보강을 시행하는 경우 접합부의 일체성을 유지하기 위해 후 설치 앵커 중에서 이형철근을 사용한 부착식 앵커를 사용한다. 그러나 부착식 앵커의 경우 접합재의 종류 등에 따라 성능이 크게 좌우됨에도 불구하고 기계식 앵커와는 달리 설계방법의 표준화와 함께 적절한 성능평가를 위한 표준적인 실험방법도 제시되지 않고 있는 실정이다. 이에 따라 본 연구에서는 철근의 겹이음 및 앵커철근을 이용한 모형실험을 실시하여 부착식 앵커의 성능에 대한 평가를 수행하였다. 실험 결과, 접합하지 않은 시험체의 구조 성능이 가장 우수하게 나타났으며, 파괴양상은 펀칭전단 파괴로 나타났다. 연결되지 않은 부재가 연결된 부재보다는 부재 끝단의 처짐이 더 작게 발생되며, 큰 크기로 연결된 부재의 처짐이 작게 연결된 부재의 처짐보다는 크게 나타나, 하중이 증가할수록 앵커 철근 또는 겹이음 철근의 미끌림 등의 현상이 발생될 가능성이 큰 것으로 나타났다.

EMAT의 유도초음파 비틀림 모드를 이용한 가압중수로 피더관의 균열 검출 (Detection of Cracks in feeder Pipes of Pressurized Heavy Water Reactor Using an EMAT Torsional Guided Wave)

  • 정용무;김상수;이동훈;정현규
    • 비파괴검사학회지
    • /
    • 제24권2호
    • /
    • pp.136-141
    • /
    • 2004
  • 배관에서의 균열 탐지를 위해서 비틀림 모드 유도초음파 검사법을 적용하였다. 배관에서 비틀림 모드의 생성 및 수신을 위하여 배열형 전자기음향 탐촉자 (EMAT, electromagnetic acoustic transducer)를 설계, 제작하였다. 직경 2.5 인치의 배관에 대해 주파수 2000kHz의 비틀림 모드 유도초음파를 적용하였으며 가진용으로 4개의 배열형 EMAT를 제작하였으며, 별도의 수신용 EMAT를 설계 제작하였다. 실제 중수로 피더관 mock-up에 대해 곡관부에 다양한 깊이의 인공 결함을 가공한 뒤 약 2 hi 거리에서 각각의 탐지능을 실험하였다. 결함 깊이가 관 두께 대비 5% 인 경우에도 결함 신호를 탐지할 수 있었으나 결함의 깊이와 신호 진폭과의 관계성은 나타나지 않았다.

150MPa급 초고강도 노출콘크리트의 현장적용에 관한 연구 (A Study on Field Application of 150MPa Ultra Strength Surface-Exposed Concrete)

  • 공태웅;이수형;장재환;이한백
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.989-992
    • /
    • 2008
  • 본 연구에서는 선일공업(주)의 축적된 기술력을 바탕으로 초고강도(150MPa급) 콘크리트를 당사 기술 연구소 신축시 노출콘크리트에 적용함으로써, 이에 대한 사례를 소개하고자 한다. 현장적용에 앞서 실내실험 및 레미콘 배치플랜트 실험(이하 B/P Test)을 통해 콘크리트의 기초물성(슬럼프플로우, 공기량, 50cm도달시간, 경시변화, 압축강도) 및 생산성을 평가하였으며, 다음으로 실구조물과 동일한 벽체두께 거푸집종류 노출콘크리트용 콘 등을 고려하여 제작한 모의부재를 대상으로 Mock-up Test를 실시하여 충진성, 표면마감성(육안관찰) 및 수화열을 평가하였다. 그 결과 슬럼프플로우, 공기량, 50cm도달시간, 경시변화 및 압축강도는 요구조건에 만족한 결과를 보였으며, 수화열 계측결과는 온도균열지수 0.78로 유해한 균열발생을 제한할 지수를 나타냈다. 현장타설시 초고강도 콘크리트의 높은 단위용적중량으로 인해 거푸집 터짐현상이 발생하였기 때문에, 재타설시에는 재발방지를 위해 거푸집을 보강하고 타설시간을 조정하였다. 또한 노출표면의 극대화를 위해 저주파(1차) 및 고주파(2차)로 2회에 걸쳐 진동다짐을 실시하였지만 표면곰보가 발생하였다. 따라서 향후 초고강도 콘크리트를 노출콘크리트에 적용할 경우, 다양한 변수조건에 대한 체계적인 시공관리계획 및 시공방법개선이 중요할 것으로 판단된다.

  • PDF

부상식 매스콘크리트 기초의 수화열 관리 및 온도균열 제어 (Heat of Hydration and Thermal Crack Control for Floating Concrete Mass Foundation)

  • 이인규;김광돈;김태욱;이준석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권1호
    • /
    • pp.156-164
    • /
    • 2010
  • 부상식 면진기초 매스콘크리트의 시공이 6차에 걸쳐 분리타설로 이루어졌다. 선행 Mock-up실험을 통하여 각각 온도이력계측과 수화열해석이 병행되었고 최선의 양생조건과 시공순서가 부여되었다. 그 결과 수화발열과 냉각시 발생가능한 온도균열은 나타나지 않았다. 그러나 현행 콘크리트 시방서 매스콘크리트편의 온도균열지수의 간이식, 정밀식 모두 낮은 범위의 지수를 나타내었다. 이는 수화열 거동 및 균열예측에 있어 온도균열 발생확률이 높은 것으로 나타나, 실제 타설경과 내용과 상이함을 알 수 있었다. 각 시공단계의 계측 및 해석결과는 대상 부재의 크기와 형상을 고려하여 부재내부를 등온도분포영역과 상대적으로 온도경사가 높은 영역으로 분리할 필요가 있음을 추정케 하였다. 결론적으로, 구조형태별 수화발열/냉각시 온도변화에 보다 민감한 특성두께를 정의하여, 현실적인 온도균열지수를 계산하는 과정과 방법이 필요하다고 사료된다.