• Title/Summary/Keyword: Mobile-lP

Search Result 150, Processing Time 0.034 seconds

Development of Interactive Mobile Learning Media on Teaching Terms of Mental Status Examination (MSE) for Nursing Students

  • PRIYONO, Djoko;Harlia PUTRI, Triyana;MAULANA, M. Ali;YANTI, Irma;PRABOWO, Thoriq Tri
    • Educational Technology International
    • /
    • v.23 no.2
    • /
    • pp.183-205
    • /
    • 2022
  • Mental status examination is an important stage in the assessment process because it serves as the foundation for establishing nursing diagnosis and intervention. Until now many students still feel difficult to understand the terms in the assessment of mental status. Interactive Mobile Learning in one of the media that is currently being developed. The use of this media will provide more in-depth learning opportunities, and students can practice their skills in carrying out practicals because of the mobility principle possessed by smartphones. The purpose of this study was to develop a smartphone-based app and evaluate the app's effectiveness by measuring nursing students' knowledge of mental status examination. Design: A randomized trial with a pre-and post-test design was conducted at a university in Indonesia. A total of seventy junior nursing students participated in this study. The intervention group received a smartphone-based app, and the control group received one-time lecture-based learning. We offered the experimental group the app and information about how to use it, and we encouraged them to use it. The control group received classroom instruction. Results: The intervention group scored significantly higher than the control group on knowledge score (t = 19.40, p = 0.000) and satisfaction with the learning method (t = 0.640, p = 0.021) Conclusion: These findings suggest that smartphonebased education could be an effective method in nursing education for teaching mental status examinations.

Separation of Two Amino Acids by Microemulsion Bulk Liquid Membrane

  • Salabat, Alireza;Sanij, Fereshteh Dehghani
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.10
    • /
    • pp.3387-3390
    • /
    • 2012
  • In this research work the potentialities of microemulsion bulk liquid membrane for the selective transport of L-tryptophan (L-Trp) and L-tyrosine (L-Tyr) are investigated at 298.15 K. Reversed micelle formed by sodium bis(2-ethylhexyl)sulfosuccinate (AOT) in dichloroethane, was used as mobile carrier to transport amino acids between a source and a receiving aqueous phase. The effects of pH, surfactant concentration and initial amino acid concentration on the extraction efficiency and transfer rate of the amino acids were studied. It is verified that for a mixture of two amino acids, L-Trp can be extracted selectively by using this type of the bulk liquid membrane with optimized condition.

DETERMINATION OF THE APPARENT ILEAL DIGESTIBILITY OF PROTEIN AND AMINO ACIDS IN FEEDSTUFFS AND MIXED DIETS FOR GROWIG-FINSHING PIGS WITH THE MOBILE NYLON BAG TECHNIQUE

  • Yin, Y.L.;Zhong, H.Y.;Huang, R.L.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.8 no.5
    • /
    • pp.433-441
    • /
    • 1995
  • A series of experiments was conducted to determine the influence of various pepsin-HCL pretreatment factor, hereby the factors of duration of washing for the retrieved bags, inherent to the mobile nylon bag technique (MNBT), on apparent ileal digestibility of crude protein (AIDCP) and apparent ileal digestibility of dry matter (AIDDM). At last, the AIDCP and apparent ileal digestibility of amino acids (AIDAA) in maize, barley, wheat, rapeseed meal, cottonseed meal and three mixed diets were determined with the MNBT and ileo-rectal anastomis pigs (IRAT). For the MNBT techniques, bag measuring $25{\times}40$ MM and containing 0.75 g feedstuff samples, after pre-digestion in vitro, were introduced into the ileo-rectal anastomis pigs (IRAT) gastrointestinal tract through a duodenal cannula and recovered in the ileal digesta between 6 and 12 h. later. 1. The apparent ileal digestibility of dry matter (AIDDM) and crude protein (AIDCP) of the tested samples, with the exception of fish meal, determined by MNBT were not affected by the different pepsin-HCL pretreatment times in vitro between 2.5 h. and 4 h. 2. There was no significant (p > 0.05) difference of the AIDCP and AIDDM of maize determined by the MNBT among different pepsin concentration (0.03%, 0.07% and 0.1 %) treatment in vitro. 3. The AIDCP determined with the MNBT was affected by the washed and unwashed recovered bags from the ileal digesta. 4. The AIDCP and AID amino acids (AIDAA) of maize, barley, wheat, rapeseed meal, soya-bean meal, cottonseed meal and three mixed diets from the MNBT, with a solution of 0.01N HCL (PH 2) and 0.1% of pepsin concentration, a pepsin-HCL pretreatment time in vitro or 4h. and a washing time of the recovered bag from the ileal digesta compared well with those from the IRAT. The linear regression analysis showed a significant correlation (p < 0.01) of AIDCP and AIDDA between the IRAT and MNBT.

Simultaneous Determination of Isoegomaketone and Perillaketone in Perilla frutescens (L.) Britton Leaves by HPLC-DAD (HPLC-DAD를 이용한 차조기 잎의 Isoegomaketone 및 Perillaketone의 동시분석법 확립)

  • Nam, Bo Mi;Lee, Seung Young;Kim, Jin-Baek;Kang, Si-Yong;Jin, Chang Hyun
    • Korean Journal of Pharmacognosy
    • /
    • v.47 no.1
    • /
    • pp.79-83
    • /
    • 2016
  • This study developed an HPLC analysis method for the determination of isoegomaketone (IK) and perillaketone (PK) in Perilla frutescens (L.) Britton leaves. P. frutescens ethanol extract was optimized through an HPLC analysis using a C18 column ($250{\times}4.6mml$, D, $S-5{\mu}m$, 12 nm) with gradient elution of water and acetonitrile as the mobile phase at a flow rate of 1 mL/min and a UV detection wavelength of 254 nm. The results of this method showed linearity in the calibration curve at a coefficient of correlation ($R^2$) of IK 0.9995, PK 0.9998. The limits of detection (LOD) for IK and PK were $0.234{\mu}g/mL$ and $0.952{\mu}g/mL$. The limits of quantification (LOQ) for IK and PK were $0.017{\mu}g/mL$ and $0.043{\mu}g/mL$. The inter-day precision RSDs of IK and PK in the P. frutescens were 1.25 to 2.69% and 0.36 to 1.10%, respectively, and the intra-day precision RSDs of IK and PK were 0.96 to 2.51% and 0.90 to 1.93%, respectively. The accuracies of IK and PK were 96.31 to 97.92% and 101.26 to 105.14%. In conclusion, this method was applied successfully to the detection of IK and PK in P. frutescens.

Validation of a HPLC Method for Determination of Pentoxifylline in Human Serum and Its Application to Single-dose Pharmacokinetics (인체혈청 중 펜톡시필린의 정량을 위한 HPLC 분석법의 점증 및 단일용량 투여에 의한 약물동태)

  • Sung, Min Kyung;Park, Hyo Min;Kim, Na Hyung;Chung, Soo Yeon;Go, Eun Jung;Lee, Hwa Jeong
    • Korean Journal of Clinical Pharmacy
    • /
    • v.15 no.1
    • /
    • pp.46-49
    • /
    • 2005
  • A simple HPLC method was employed for the determination of pentoxifylline in human serum. After addition of internal standard (IS, 50 uL of 3 ug/mL chloramphenicol methanol solution) into the serum sample, the drug and IS were extracted by dichloromethane. Following a 1-min vortex-mixing and a 15-min centrifugation at 3500 게m, the organic phase was transferred and evaporated to dryness under a vacuum. The residue was reconstituted with 120 ${\mu}L$ of mobile phase and 50 ${\mu}L$ was injected into C18 column with a mobile phase composed of 0.034 M phosphoric acid adjusted to pH 4 with 10 M NaOH and acetonitrile (75:25, v/v). The samples were detected using an ultraviolet detector at 273 nm. The method was simple, specific and validated with a limit of 10 ng/mL. Intra- and inter-day precision and accuracy were acceptable for all quality control samples including the lower limit of quantification. The applicability of this method was evaluated by analysis of human serum after oral administration of a single 400 mg dose to 8 healthy subjects. The pharmacokinetic parameters for pentoxifylline in human subjects were calculated using WinNonlin program. As a result, $AUC_{t},\;C_{max},\;T_{max}$ and $t_{1/2}$ were $962.28{\pm}645.69\;ng{\cdot}/mL$, $132.82{\pm}42.05$ ng/mL, $2.06{\pm}2.68$ hr and $8.74{\pm}4.38$ hr, respectively. Based on the results, this validated method appears to be useful fur the pharmnacokinetic study of pentoxifylline in humans.

  • PDF

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Etodolac in Human (에토돌락 체내동태 연구를 위한 혈청 중 에토돌락의 HPLC 정량법 개발 및 검증)

  • Cho, Hea-Young;Kang, Hyun-Ah;Moon, Jai-Dong;Choi, Hoo-Kyun;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.4
    • /
    • pp.265-271
    • /
    • 2005
  • A rapid, selective and sensitive reversed-phase HPLC method for the determination of etodolac in human serum was developed, validated, and applied to the pharmacokinetic study of etodolac. Etodolac and internal standard, ibuprofen were extracted from human serum by liquid-liquid extraction with hexane/isopropanol (95:5, v/v) and analyzed on a Luna C18(2) column with the mobile phase of 1% aqueous acetic acid-acetonitrile (4:6, v/v). Detection wavelength of 227 nm and flow rate of 1.0 mL/min were fixed for the study. The assay robustness for the changes of mobile phase pH, organic solvent content, and flow rate was confirmed by $3^3$ factorial design using a fixed etodolac concentration $(1\;{\mu}g/mL)$ with respect to its peak area and retention time. And also, the ruggedness of this method was investigated at three different laboratories using same quality control (QC) samples. This method showed linear response over the concentration range of $0.05-40\;{\mu}g/mL$ with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of serum was 0.05 ${\mu}g/mL$, which was sensitive enough for pharmacokinetic studies. The overall accuracy of the quality control samples ranged from 92.00 to 110.00% for etodolac with overall precision (% C.V.) being 1.08-10.11%. The percent recovery for human serum was in the range of 76.73-115.30%. Stability studies showed that etodolac was stable during storage, or during the assay procedure in human serum. The peak area and retention time of etodolac were not significantly affected by the changes of mobile phase pH, organic solvent content, and flow rate under the conditions studied. This method showed good ruggedness (within 15% C.V.) and was successfully used for the analysis of etodolac in human serum samples for the pharmacokinetic studies of orally administered Lodin XL tablet (400 mg as etodolac) at three different laboratories, demonstrating the suitability of the method.

Separation of Optical Isomers of Amino Acids with Addition of Benzyl-L-proline Copper (II) Chelate by Reversed Phase Liquid Chromatography

  • Lee, Sun-Haing;Oh, Dae-Sub;Kim, Byoung-Eog
    • Bulletin of the Korean Chemical Society
    • /
    • v.9 no.6
    • /
    • pp.341-345
    • /
    • 1988
  • Separation of optical isomers of dansyl amino acids by a reversed phase liquid chromatography has been accomplished by adding a copper (II) chelate of N-benzyl-L-proline to the mobile phase. The pH, the eluent composition and the concentration of copper (II) chelate all affect the optical separations. The elution orders between D and L DNS-amino acids were consistant except dansyl phenylalanine showing that D forms of DNS-amino acids elute earlier than L forms. These behaviors are different from the results obtained by the use of copper (II) proline. The retention mechanism for the optical separation of the dansyl amino acids can be explained by the equilibrium of liqand exchange and by hydrophobic interaction.

Determination of carvedilol in human plasma by high-performance liquid chromatography

  • Lee, Jung-Ae;Lee, Ye-Rie;Kim, Ho-Hyun;Lee, Hee-Joo;Lee, Kyung-Ryul
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.220.1-220.1
    • /
    • 2003
  • A sensitive and selective liquid chromatographic method for the determination of carvedilol in human plasma was developed and validated. Analytes were separated on a XTerra C18 column with acetonitrile-methanol-30 mM KH$_2$PO$_4$ (pH 2.5) (20 : 20 : 60, v/v/v), as mobile phase. One mL plasma were pipetted into glass tubes and spiked with 0.05 mL of internal standard solution. After adding 7 mL of diethyl ether, the plasma sample was then shacked for 15 min. A centrifuged upper layer was back-extracted with 150 uL of 0.05 M sulfuric acid. (omitted)

  • PDF

Simultaneous Determination of Tin, Nickel, Lead, Cadmium and Mercury in Cigarette Material by Solid Phase Extraction and HPLC

  • Hu, Qun;Yang, Guangyu;Ma, Jing;Liu, Jikai
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.10
    • /
    • pp.1433-1436
    • /
    • 2003
  • A new method for the simultaneous determination of heavy metal ions in cigarette material by microwave digestion and reversed-phase high-performance liquid chromatography (RP-HPLC) has been developed. The cigarette material was digested by microwave digestion. Lead, cadmium, mercury, nickel and tin ions in the digested samples were pre-column derivatized with tetra-(2-chlorophenyl)-porphyrin ($T_2$-CPP) to form color chelates, which were then enriched by solid phase extraction with a $C_{18}$ cartridge. The chelates were separated on a Waters Xterra$^{TM}RP_{18}$ column by gradient elution with methanol (containing 0.05 mol/L pyrrolidine-aceticacid buffer salt, pH = 10.0) and acetone (containin0.05 mol/L pyrrolidine-acetic acid buffer salt, pH = 10.0)as mobile phase at a flow rate of 0.5mL/min and analyzed with a photodiode array detector from 350-600 nm. The detection limits of lead, cadmium, mercury, nickel and tin were 4,3,3,8 and 5 ng/L, respectively, in the original samples. This method was afforded good results.

Separation and Determination of Co(II) and Ni(II) Ion as their 4-(2-Pyridylazo) resorcinol Chelates by Reversed-Phase Capillary High-Performance Liquid Chromatography (역상 모세관-고성능 액체 크로마토그래피에 의한 코발트와 니켈 이온의 4-(2-피리딜아조)레조루신올 킬레이트로서의 분리 및 정량)

  • Chung, Yong-Soon;Chung, Won-Seog
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.6
    • /
    • pp.547-552
    • /
    • 2003
  • Separation and determinations of Co(II) and Ni(II) ions as their 4-(2-pyridylazo)resorcinol(PAR) chelates by reversed-phase capillary high-performance liquid chromatography(RP-CpHPLC) were performed. Among many capillary columns, Vydac C4 column was selected and acetonitrile solution was used as mobile phase. The effect of pH and MeCN concentration(%) on the retention factor, k and peak intensity was examined and discussed. As a results, it was found that 22.5% MeCN and pH 5.60 was adequate as mobile phase for the separation of the two metal ions and determination of Co(II) ion, but the mobile phase condition for Ni(II) ion determination was 22.5% MeCN of pH 7.20. Detection limit(D.L., S/N=3) of Co(II) and Ni(II) ions were $2.0{\times}10{-7}$ M(14.9 ppb) and $1.0{\times}10{-6}$ M(59.2 ppb), respectively.