• Title/Summary/Keyword: Mobile-lP

Search Result 150, Processing Time 0.023 seconds

Determination of Fructooligosaccharides and Raffinose in Infant Formula by High Performance Liquid Chromatography with Evaporative Light Scattering Detector (HPLC-ELSC를 이용한 조제분유 중 fructooligosaccharides 및 raffinose 분석)

  • Shin, Man-Sub;Park, Jae-Woo;Cho, Mi-Ran;Song, Sung-Ok;Kim, Chun-Sun;Choi, Chun-Bae;Lee, Seoung-Won;Lee, Ki-Woong;Chang, Chi-Hoon;Kwak, Byung-Man
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.725-729
    • /
    • 2006
  • A method was developed for the determination of fructooligosaccharides and raffinose contents in infant formula. The samples were extracted and analyzed by liquid chromatography equipped with carbohydrate column and evaporative light scattering detector. The mobile phase used for the gradient mode was water-acetonitrile, at a flow rate of 1.0mL/min. The method showed a mean recovery of 95-99%, the relative standard deviation obtained in the precision study was 0.774-8.982%, the quantification and detection limits were 25-50mg/L.

Development and Validation of an HPLC Method for the Pharmacokinetic Study of Pentoxifylline in Human Serum (체내동태 연구를 위한 혈청 중 펜톡시필린의 HPLC 정량법 개발 및 검증)

  • Cho, Hea-Young;Kang, Hyun-Ah;Yoo, Hee-Doo;Lee, Hwa-Jeong;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.2
    • /
    • pp.89-95
    • /
    • 2006
  • A selective and sensitive reversed-phase HPLC method for the determination of pentoxifylline in human serum was developed, validated, and applied to the pharmacokinetic study of pentoxifylline. Pentoxifylline and internal standard, chloramphenicol, were extracted from the serum by liquid-liquid extraction with dichloromethane and analyzed on a Luna CI8(2) column with the mobile phase of acetonitrile-0.034 M phosphoric acid (25:75, v/v, adjusted to pH 4.0 with 10 M NaOH). Detection wavelength of 273 nm and flow rate of 0.8 mL/min were used. This method showed linear response over the concentration range of 10-500 ng/mL with correlation coefficients greater than 0.999. The lower limit of quantification using 0.5 mL of the serum was 10 ng/mL, which was sensitive enough for pharmacokinetic studies of pentoxifylline. The overall accuracy of the quality control samples ranged from 89.3 to 92.7% for pentoxifylline with overall precision (% C.V.) being 4.1-9.2%. The relative mean recovery of pentoxifylline for human serum was 105.8%. Stability (stock solution, short and long-term) studies showed that pentoxifylline was not stable during storage. But three freeze-thaw cycles and extracted serum samples were stable. This method showed good ruggedness (within 15% C.V.) and was successfully applied for the analysis of pentoxifylline in human serum samples for the pharmacokinetic studies of orally administered $Trental^{\circledR}$ tablet (400 mg pentoxifylline), demonstrating the suitability of the method.

Simultaneous Determination of Synephrine and N-Methyltyramine in Orange Fruit and Juice from Korean Market by UPLC-FLD (UPLC-FLD를 이용한 국내 시판 오렌지 및 오렌지 주스 중 시네프린 및 n-메틸티라민 동시분석)

  • Kim, Hyo Jin;Kwak, Byung-Man;Ahn, Jang-Hyuk;Park, Jong-Su
    • Korean Journal of Food Science and Technology
    • /
    • v.46 no.3
    • /
    • pp.276-282
    • /
    • 2014
  • An accurate and sensitive analytical method was established for the simultaneous determination of synephrine and n-methyltyramine contents by ultra-performance liquid chromatography (UPLC) with a fluorescence detector (FLD). A 70:30 (v/v) mixture of 10 mM sodium dodecyl sulfate (SDS) and acetonitrile was used as the mobile phase. The coefficient of correlation ($r^2$) was 0.9999 for both synephrine and n-methyltyramine, and their limits of detection (LOD) were 0.02 and 0.01 mg/kg, respectively. The percentage recoveries for synephrine and n-methyltyramine were 96.4% and 100.9%, respectively, from bitter orange (Citrus aurantium) samples. The synephrine and n-methyltyramine contents were 38.07-118.21 mg/kg and 0.27-0.56 mg/kg, respectively, in the orange fruit samples, while they were 14.61-120.39 mg/kg and up to 3.34 mg/kg, respectively, in the tested commercial orange juice samples. The differences in synephrine and n-methyltyramine content between orange fruit and commercial orange juice were not significant (p<0.05). These results suggest that UPLC-FLD can be applied to develop an analytical method of quality control for commercial orange juice.

Analytical Method for Sodium Polyacrylate in Processed Food Products by Using Size-exclusion Chromatography (Size-exclusion Chromatography를 활용한 가공식품 중 폴리아크릴산나트륨 분석법 확립)

  • Jeong, Eun-Jeong;Choi, Yoo-Jeong;Lee, Gunyoung;Yun, Sang Soon;Lim, Ho Soo;Kim, MeeKyung;Kim, Yong-Suk
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.6
    • /
    • pp.466-473
    • /
    • 2018
  • An analytical method of sodium polyacrylate in processed food products was developed and monitored by using size-exclusion chromatography. GF-7M HQ column and UV/VIS detector were selected based on peak shape and linearity. Flow rate, column oven temperature, and mobile phase were selected as 0.6 mL/min, $45^{\circ}C$, and 50 mM sodium phosphate buffer of pH 9.0, respectively. Samples for analysis of sodium polyacrylate were extracted with 50 mM sodium phosphate buffer of pH 7.0 for 3 hr at $20^{\circ}C$ and 150 rpm. Analytical method validation revealed proper selectivity and calibration curve was selected in the range of 50-500 mg/L, and correlation coefficient of calibration curve was more than 0.9985. Limit of detection of sodium polyacrylate was 10.95 mg/kg and limit of quantification was 33.19 mg/kg. Accuracy and coefficient of variation for sodium polyacrylate analysis was 99.6-127.6%, 3.0-8.3% for intra-day and 94.3-121.9%, 1.3-2.6% for inter-day, respectively. Sodium polyacrylate was detected in 40 samples among monitored 125 processed food products. Detected contents were less than 0.2%, limited by the Food Additives Code. Results suggest the established size-exclusion chromatography method could be used to analyze sodium polyacrylate in processed food products.

Analysis of Four Pesticides, Isoproturon, Phenmedipham, Pyridate and Nitenpyram Residues by High-Performance Liquid Chromatography with Diode-Array Detector (HPLC를 이용한 Isoproturon, Phenmedipham, Pyridate 및 Nitenpyram 4종 성분의 잔류농약 분석법 개발)

  • Yang, Sung-Yong;Koo, Yun-Chang;Wang, Zeng;Heo, Kyeong;Kim, Hyeong-Kook;An, Eun-Mi;Shin, Han-Seung;Lee, Jin-Won;Lee, Kwang-Won
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.8
    • /
    • pp.1165-1170
    • /
    • 2010
  • A method for the determination of four pesticide compounds, urea (isoproturon), bis-carbamate (phenmedipham), thiocarbamate (pyridate) and vinyllidenediamine (nitenpyram) were examined and analyzed by HPLC with C-18 column ($250\;mm{\times}4.6\;mm$, $5\;{\mu}m$ diameter particle size). Mobile phase consisted of deionized water, acetonitrile and 50 mM $KH_2PO_4$ (pH 2.5). Isoproturon and phenmedipham analytical condition was isocratic elution of the column with 50% solvent A (acetonitrile) and 50% solvent B (deionized water); pyridate was 85% solvent A (acetonitrile) and 15% solvent B (deionized water) at a flow rate of 1 mL/min; and nitenpyram analytical condition was 90% solvent A (50 mM $KH_2PO_4$, pH 2.5) and 10% solvent B (acetonitrile) at a flow rate of 1 mL/min. In results, retention times were 6.12, 8.63, 9.40 and 12.76 min for isoproturon, phenmedipham, pyridate and nitenpyram, respectively. All injection volumes were $10\;{\mu}L$ and the limit of quantitation was 0.05 mg/kg for four pesticide compounds, respectively. Recovery rate test was performed with three farm products, rice, apple and soybean. Four pesticide compounds were spiked at concentrations of 0.05, 0.1 and 0.5 mg/kg. The recovery rates were ranged from 70.18% to 118.08% and the standard deviations of all experiments were within 10%.

Rapid HPLC Method for the Simultaneous Determination of Eight Urinary Metabolites of Toluene, Xylene and Styrene

  • Lee, Cheol-Woo;Lee, Jeong-Mi;Lee, Jae-Hyun;Eom, Han-Young;Kim, Min-Kyung;Suh, Joon-Hyuk;Yeom, Hye-Sun;Kim, Un-Yong;Youm, Jeong-Rok;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.9
    • /
    • pp.2021-2026
    • /
    • 2009
  • Toluene, xylene and styrene are volatile organic solvents that are commonly used in mixtures in many industries. Because these solvents are metabolized and then excreted in urine, their urinary metabolites are thought to be biomarkers of occupational exposure to these solvents. Therefore, a simple, rapid, and yet reliable analytical method for determining the metabolites is required for accurate biological monitoring. In the present study, a simple and rapid HPLC-UV method was developed for the simultaneous determination of eight major metabolites of toluene, xylene and styrene: hippuric acid (HA), mandelic acid (MA), o-, m- and p-methylhippuric acids (o-, m- and p-MHAs), and o-, m- and p-cresols. A monolithic column was employed as the stationary phase and several conditions, including flow rate, composition of mobile phase and column temperature, were variables for the optimization of the chromatographic resolution. All eight metabolites were successfully resolved within 5 minutes in 10% aqueous ethanol containing 0.3% acetic acid and 1.6% $\beta$-cyclodextrin, using a flow rate gradient of 1.0 - 5.0 mL/min at 25 ${^{\circ}C}$. The performance of this method was validated by linearity, intra- and inter-day accuracy, and precision. The linearity was observed with correlation coefficients of 0.9998 for HA, 0.9999 for MA, 0.9989 for o-MHA, 0.9998 for m-MHA, 0.9991 for p-MHA, 0.9997 for o-cresol, 0.9998 for m-cresol, and 0.9986 for p-cresol. The intra- and inter-day precision of the method were less than 5.89% (CV) and the accuracy ranged from 92.95 to 106.62%. The validity was further confirmed by analysis of reference samples that were prepared by the inter-laboratory quality assurance program of the Korea Occupational Safety and Health Agency (KOSHA, Seoul, Korea). All measured concentrations of the analytes agreed with the certified values.

A Study on Fabrication and Performance Evaluation of Wideband 2-Mode HPA for the Satellite Mobile Communications System (이동위성 통신용 광대역 2단 전력제어 HPA의 구현 및 성능평가에 관한 연구)

  • 전중성;김동일;배정철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.3
    • /
    • pp.517-531
    • /
    • 1999
  • This paper presents the development of the 2-mode variable gain high power amplifier for a transmitter of INMARSAT-M operating at L-band(1626.5-1646.5 MHz). This SSPA(Solid State Power Amplifier) is amplified 42 dBm in high power mode and 36 dBm in low power mode for INMARSAT-M. The allowable error sets +1 dBm of an upper limit and -2 dBm of a lower limit, respectively. To simplify the fabrication process, the whole system is designed by two parts composed of a driving amplifier and a high power amplifier, The HP's MGA-64135 and Motorola's MRF-6401 are used for driving amplifier, and the ERICSSON's PTE-10114 and PTF-10021 are used the high power amplifier. The SSPA was fabricated by the circuits of RF, temperature compensation and 2-mode gain control circuit in aluminum housing. The gain control method was proposed by controlling the voltage for the 2-mode. In addition, It has been experimentally verified that the gain is controlled for single tone signal as well as two tone signals. The realized SSPA has 42 dB and 36 dB for small signal gain within 20 MHz bandwidth, and the VSWR of input and output port is less than 1.5:1 The minimum value of the 1 dB compression point gets 5 dBm for 2-mode variable gain high power amplifier. A typical two tone intermodulation point has 32.5 dBc maximum which is single carrier backed off 3 dB from 1 dB compression point. The maximum output power of 43 dBm was achieved at the 1636.5 MHz. These results reveal a high power of 20 Watt, which was the design target.the design target.

  • PDF

Liquid Chromatography Quadrupole Time-Of-Flight Tandem Mass Spectrometry for Selective Determination of Usnic Acid and Application in Pharmacokinetic Study

  • Fang, Minfeng;Wang, Hui;Wu, Yang;Wang, Qilin;Zhao, Xinfeng;Zheng, Xiaohui;Wang, Shixiang;Zhao, Guifang
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1684-1688
    • /
    • 2013
  • A rapid and sensitive method for determining usnic acid of Lethariella cladonioides in rat was established using high performance liquid chromatography (HPLC) quadrupole time-of-flight (QTOF) tandem mass (MS/MS). Rat plasma was pretreated by mixture of acetonitrile and chloroform to precipitate plasma proteins. Chromatographic separation was achieved on a column ($50{\times}2.1$ mm, $5{\mu}m$) with a mobile phase consisting of water (containing $5{\times}10^{-3}$ M ammonium formate, pH was adjusted to 3.0 with formic acid) and acetonitrile (20:80, v/v) at a flow rate of 0.3 mL/min. A tandem mass spectrometric detection with an electrospray ionization (ESI) interface was conducted via collision induced dissociation (CID) under negative ionization mode. The MS/MS transitions monitored were m/z 343.0448 ${\rightarrow}$ m/z 313.2017 for usnic acid and m/z 153.1024 ${\rightarrow}$ m/z 136.2136 for protocatechuic acid (internal standard). The linear range was calculated to be 2.0-160.0 ng/mL with a detection limit of 3.0 pg/mL. The inter- and intra-day accuracy and precision were within ${\pm}7.0%$. Pharmacokinetic study showed that the apartment of usnic acid in vivo confirmed to be a two compartment open model. The method was fully valid and will probably be an alternative for pharmacokinetic study of usnic acid.

Optimized Conditions for In Situ Immobilization of Lipase in Aldehyde-silica Packed Columns

  • Seo Woo Yong;Lee Kisay
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.6
    • /
    • pp.465-470
    • /
    • 2004
  • Optimal conditions for the in situ immobilization of lipase in aldehyde-silica packed columns, via reductive amination, were investigated. A reactant mixture, containing lipase and sodium borohydride (NaCBH), was recirculated through an aldehyde-silica packed column, such that the covalent bonding of the lipase, via amination between the amine group of the enzyme and the aldehyde terminal of the silica, and the reduction of the resulting imine group by NaCBH, could occur inside the bed, in situ. Mobile phase conditions in the ranges of pH $7.0{\~}7.8$, temperatures between $22{\~}28^{circ}C$ and flow rates from $0.8{\~}1.5\;BV/min$ were found to be optimal for the in situ immobilization, which routinely resulted in an immobilization of more than 70 mg­lipase/g-silica. Also, the optimal ratio and concentration for feed reactants in the in situ immobilization: mass ratio [NaCBH]/[lipase] of 0.3, at NaCBH and lipase concentrations of 0.75 and 2.5 g/L, respectively, were found to display the best immobilization characteristics for concentrations of up to 80 mg-lipase/g-silica, which was more than a 2-fold increase in immobilization compared to that obtained by batch immobilization. For tributyrin hydrolysis, the in situ immobilized lipase displayed lower activity per unit mass of enzyme than the batch-immobilized or free lipase, while allowing more than a $45\%$ increase in lipase activity per unit mass of silica compared to batch immobilization, because the quantity of the immobilization on silica was aug­mented by the in situ immobilization methodology used in this study.

Development of 'Children's Food Avatar' Application for Dietary Education (식생활교육용 '어린이 푸드 아바타' 애플리케이션 개발)

  • Cho, Joo-Han;Kim, Sook-Bae;Kim, Soon-Kyung;Kim, Mi-Hyun;Kim, Gap-Soo;Kim, Se-Na;Kim, So-Young;Kim, Jeong-Weon
    • Korean Journal of Community Nutrition
    • /
    • v.18 no.4
    • /
    • pp.299-311
    • /
    • 2013
  • An educational application (App) called 'Children's Food Avatar' was developed in this study by using a food DB of nutrition and functionality from Rural Development Administration (RDA) as a smart-learning mobile device for elementary school students. This App was designed for the development of children's desirable dietary habits through an on-line activity of food choices for a meal from food DB of RDA provided as Green Water Mill guide. A customized avatar system was introduced as an element of fun and interactive animation for children which provides nutritional evaluation of selected foods by changing its appearance, facial look, and speech balloon, and consequently providing chances of correcting their food choices for balanced diet. In addition, nutrition information menu was included in the App to help children understand various nutrients, their function and healthy dietary life. When the App was applied to 54 elementary school students for a week in November, 2012, significant increases in the levels of knowledge, attitude and behavior in their diet were observed compared with those of the control group (p < 0.05, 0.01). Both elementary students and teachers showed high levels of satisfaction ranging from 4.30 to 4.89 for the App, therefore, it could be widely used for the dietary education for elementary school students as a smart-learning device.