• Title/Summary/Keyword: MoS$_2$ Film

Search Result 169, Processing Time 0.029 seconds

A Survey on Radiation Exposure of Patient in Mammography (유방 X선촬영 시 피폭선량에 대한 조사 연구)

  • Kim, Hyung-Chul;Cho, Pyung-Gon;Kim, Sung-Soo;Choi, Jong-Hak;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.27 no.4
    • /
    • pp.55-60
    • /
    • 2004
  • The purpose of this study was to examine both patient exposure dose during mammography and the utility status of mammograpy equipments. The data of this study were collected through questionnaire survey for 278 medical facilities registered at Korean Hospital Association and finally 161 medical facilities's data were analyzed. According to data analysis, medical facilities of 14.9% used the average glandular dose of less than 0.5 mGy, $0.51{\sim}1.0\;mGy$ 8.6%, $1.01{\sim}1.5\;mGy$ 14.9%, $1.51{\sim}2.0\;mGy$ 11.1%, $2.01{\sim}2.5\;mGy$ 9.8%, $2.51{\sim}3.0\;mGy$ 33.3%, and 7.4% more than 3.01 mGy. It was found that medical facilities of 92.6% used less than 3 mGy, showing that this figure is similar to the limit value of 3 mGy recommended by Korea Food & Drug Administration(KFDA). Recently, international organizations such as ICRP associated with radiation protection suggests that less than 3 mGy of average mammary gland dose be used during mammography in case of using Mo target+Mo filter, film/screen system and craniocaudal projection with the breast pressed to 4.2 cm. The standard dose is being strictly observed and that of the limits is going down to 2 mGy or 1.5 mGy. The major results of this study indicate that interests and a counterplan to reduce patient dose during mammography should be considered. Based on this study, the authors of this study will continue to measure exposure dose to set a new standard for patient exposure dose during mammography.

  • PDF

Dosimetric Characteristics of Multileaf Collimator-based Intensity-modulated Arc Therapy for Stereotactic Radiosurgery (방사선수술 시 다엽 콜리메이터를 기초로 한 IMAT의 선량분포)

  • Yun, Sang-Mo;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.18 no.2
    • /
    • pp.93-97
    • /
    • 2007
  • This study was designed to evaluate radiosurgery technique using multiple noncoplanar arc therapy with intensity modulated fine MLC shaped photon beam. The stereotactic radiosurgery was performed with 6-MV X-ray beams from a Clinac 21EX LINAC (Varian, Palo Alto, CA, USA) with a MLC-120, which features a full $40{\times}40cm$ field and is the first MLC for general use that offers 0.5 cm resolution for high precision treatment of small and irregular fields. We used a single isocenter and five gantry-couch combinations with a set of intensity modulated arc therapy. We investigated dosimetric characteristics of 2 cm sized spherical target volume with film (X-OMAT V2 film, Kodak Inc, Rochester NY, USA) dosimetry within $25{\times}25cm$ acrylic phantom. A simulated single isocentric treatment using inversely Planned 3D radiotherapy planning system demonstrated the ability to conform the dose distribution to an spherical target volume. The 80% dose level was adequate to encompass the target volume in frontal, sagittal, and transverse planes, and the region between the 40% and 80% isodose lines was $4.0{\sim}4.5mm$ and comparable to the dose distribution of the Boston Arcs. We expect that our radiosurgery technique could be a treatment option for irregular-shaped large intracranial target.

  • PDF

Effect of Degraded Al-doped ZnO Thin Films on Performance Deterioration of CIGS Solar Cell (고온 및 고온고습 환경 내에서 ZnO:Al 투명전극의 열화가 CIGS 박막형 태양전지의 성능 저하에 미치는 영향)

  • Kim, Do-Wan;Lee, Dong-Won;Lee, Hee-Soo;Kim, Seung-Tae;Park, Chi-Hong;Kim, Yong-Nam
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.4
    • /
    • pp.328-333
    • /
    • 2011
  • The influence of Al-doped ZnO (AZO) thin films degraded under high temperature and damp heat on the performance deterioration of Cu(In,Ga)$Se_2$ (CIGS) solar cells was investigated. CIGS solar cells with AZO/CdS/CIGS/Mo structure were prepared on glass substrate and exposed to high temperature ($85^{\circ}C$) and damp heat ($85^{\circ}C$/85% RH) for 1000 h. As-prepared CIGS solar cells had 64.91% in fill factor (FF) and 12.04% in conversion efficiency. After exposed to high temperature, CIGS solar cell had 59.14% in FF and 9.78% in efficiency, while after exposed to damp heat, it had 54.00% in FF and 8.78% in efficiency. AZO thin films in the deteriorated CIGS solar cells showed increases in resistivity up to 3.1 times and 4.4 times compared to their initial resistivity after 1000 h of high temperature and damp heat exposure, respectively. These results can be explained by the decreases in carrier concentration and mobility due to diffusion or adsorption of oxygen and moisture in AZO thin films. It can be inferred that decreases in FF and conversion efficiency were caused by an increase in series resistance, which resulted from an increase in resistivity of AZO thin films degraded under high temperature and damp heat.

인공관절의 수명 향상을 위해 PIII&D (Plasma Immersion Ion Implantation & Deposition) 기술로 제조된 인공관절용 NbN 박막의 마모 특성 평가

  • Park, Won-Ung;Jeon, Jun-Hong;Mun, Seon-U;Choe, Jin-Yeong;Im, Sang-Ho;Han, Seung-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.189-189
    • /
    • 2011
  • 인공관절은 노인성 질환이나 자가 면역질환, 신체적인 외상 등으로 인하여 발생하는 관절의 손상 부위를 대체하기 위해 고안된 관절의 인공 대용물이다. 인공 관절 중 인공 고관절의 경우 관절 운동을 하는 라이너(Liner)와 헤드(Head) 부분이 인공관절의 수명을 결정하게 되는데, 헤드 부분에 메탈소재와 라이너 부분에 고분자 소재를 사용하는 MOP (metal on polymer) 구조의 인공관절은 충격흡수의 장점이 있는 반면 wear debris에 의한 골용해로 인하여 관절이 느슨해지는 문제점이 발생하여 재 시술의 주요 원인이 되고 있다. 또한 메탈 헤드의 마모로 인한 금속이온의 용출은 세포 독성의 문제를 야기하여 인공관절의 수명을 낮추는 또 하나의 요인이 되고 있다. 따라서 인공관절의 수명을 늘리기 위해 DLC, ZrO, TiN 등의 높은 경도 값을 갖는 박막을 금속 헤드 위에 증착하여 상대재인 인공관절용 고분자 소재의 마모량을 줄이고자 하는 연구가 활발하게 진행 되고 있다. 본 연구에서는 PIII&D (Plasma Immersion Ion Implantation & Deposition)공정을 이용하여 Co-Cr-Mo 합금 소재 niobium nitride (NbN) 박막을 증착하여 상대제인 UHMWPE (ultra high molecular polyethylene)의 마모를 줄이고자 하는 연구를 진행하였다. 마모량을 감소시키기 위하여, 박막 증착전에 질소를 이온주입하는 pre-ion implantation 공정을 도입하였으며, 또한 Co-Cr 합금과 NbN박막 사이의 접착력을 증가시키기 위하여 박막의 증착 초기에 이온주입과 증착을 동시에 수행하는 dynamic ion mixing공정을 수행하였다. NbN 박막의 특성을 평가하기 위해 XRD, XPS, AFM 등의 분석을 수행하였으며, 상대재인 초고분자량 폴리에틸렌의 마모량을 측정하기 위해 Pin-on-disk tester를 이용하여 마모 실험을 진행하였다. 마모 실험 결과, pre-ion implantation 공정을 도입한 경우 현재 상용화 되어있는 Co-Cr 합금에 비하여 마모량을 2배 이상 감소시키는 것을 확인 할 수 있었으며, dynamic ion mixing 공정을 도입한 경우 장시간의 마모 시험에 대한 마모 특성이 향상 되는 것을 확인 할 수 있었다.

  • PDF

Growth Characteristics of Ginseng Seedlings as Affected by Mixed Nursery Soil under Polyethylene Film Covered Greenhouse (비닐하우스에서 상토의 조성에 따른 묘삼의 생장특성)

  • Park, Hong Woo;Jang, In Bae;Kim, Young Chang;Mo, Hwang Sung;Park, Kee Choon;Yu, Jin;Kim, Jang Uk;Lee, Eung Ho;Kim, Ki Hong;Hyun, Dong Yun
    • Korean Journal of Medicinal Crop Science
    • /
    • v.22 no.5
    • /
    • pp.363-368
    • /
    • 2014
  • This study was conducted to find out the optimum composition of nursery soil for raising seedling of ginseng (Panax ginseng C. A. Meyer). Total 9 kinds of raw materials were used such as peat-moss, perlite, leaf mould, rice bran, gull's guano, castor-oil plant bark, palm bark, cow manure and chicken manure for optimum composition of nursery soil in ginseng. Occurrence of damping-off in ginseng was lowered about 50% in nursery soil type 1, 2 and 4 than in other types nursery soil in June, and occurrence rate of rusty root also lowest in nursery soil type 1. As the salinity of nursery soil increased, so did the occurrence of physiological disorder in ginseng seedling. The cause of salinity increasing in nursery soil has closely relation to $NO_3-N$, $P_2O_5$ and $Na^+$ content. Plant height, root length, diameter and weight were longer and heavier in nursery soil type 1 (mixing ratio of peat-moss, perlite and leaf mould was 50 : 20 : 30 based in volume) than in other types of nursery soil. So nursery soil type 1 was selected for raising seedling of ginseng. pH and electric conductivity (EC) of selected nursery soil type 1 was 5.55 and 0.13 dS/m. Contents of $NO_3-N$ and $P_2O_5$ were 21.0 and 40.0 mg/L, and $K^+$ 0.36, $Ca^{2+}$ 3.38, $Mg^{2+}$ 2.01 and $Na^+$ $0.09cmol^+/L$, respectively.

Effect of exposure time and image resolution on fractal dimension (노출 시간과 영상 해상도가 프랙탈 차원값에 미치는 영향)

  • An Byung-Mo;Heo Min-Suk;Lee Seung-Pyo;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;Kim Jong-Dae
    • Imaging Science in Dentistry
    • /
    • v.32 no.2
    • /
    • pp.75-79
    • /
    • 2002
  • Purpose : To evaluate the effect of exposure time and image resolution on fractal dimension calculations for determining the optimal range of these two variances. Materials and Methods : Thirty-one radiographs of the mandibular angle area of sixteen human dry mandibles were taken at different exposure times (0.01, 0.08, 0.16, 0.25, 0.40, 0.64, and 0.80 s). Each radiograph was digitized at 1200 dpi, 8 bit, 256 gray level using a film scanner. We selected an Region of Interest (ROI) that corresponded to the same region as in each radiograph, but the resolution of ROI was degraded to 1000, 800, 600, 500, 400, 300, 200, and 100 dpi. The fractal dimension was calculated by using the tile-counting method for each image, and the calculated values were then compared statistically. Results: As the exposure time and the image resolution increased, the mean value of the fractal dimension decreased, except the case where exposure time was set at 0.01 seconds (α = 0.05). The exposure time and image resolution affected the fractal dimension by interaction (p<0.001). When the exposure time was set to either 0.64 seconds or 0.80 seconds, the resulting fractal dimensions were lower, irrespective of image resolution, than at shorter exposure times (α = 0.05). The optimal range for exposure time and resolution was determined to be 0.08- 0.40 seconds and from 400-1000 dpi, respectively. Conclusion : Adequate exposure time and image resolution is essential for acquiring the fractal dimension using tile-counting method for evaluation of the mandible.

  • PDF

Export Competitiveness of Busan Port: Market Comparative Advantage Index (시장비교우위지수를 이용한 부산항의 수출경쟁력 분석)

  • Mo, Soo-Won;Chung, Hong-Young;Lee, Kwang-Bae
    • Journal of Korea Port Economic Association
    • /
    • v.31 no.3
    • /
    • pp.141-153
    • /
    • 2015
  • This paper is an attempt to analyze the comparative advantage of Busan Port to China. For this, we use the market comparative advantage index, which is a version of the revealed comparative advantage index. The market comparative advantage index (MCA) uses trade patterns to identify the sectors in which a region has a comparative advantage, in this case by comparing Busan Port's trade profile with the world average (China). The indices are calculated at the commodity level of the HS four-digit classification. The export data used in this study are obtained from the Korea International Trade Association. Exports to China accounted for almost one third of Korean exports in 2014. There are, however, structural differences among the main export items of Busan Port. This paper, therefore, employs MCA indices to reveal the behaviors of the ten main export items, which are "HS3920-other plates/sheets/film/foil of plastics," "HS7606-aluminum plates/sheets/strip," "HS8479-unspecified machines/medical appliances," "HS8486-machines for semiconductor devices or wafers," "HS8529-parts for transmission apparatus for television," "HS8703-motor vehicles for the transport of persons," "HS8708-parts of motor vehicles," "HS9001-optical fibers," and "HS9013-liquid crystal devices." The study shows that export competitiveness of nine items increases, the exception being HS8703. However, China's import ratios of seven of the nine items for which the MCA indices go up are on the decrease, which means that it would be hard to expand the export market for these seven items, despite the higher MCA indices. Since the shares of the port's total exports to China of HS3907, HS8486, HS8529, HS9001, and HS9013 in total exports to China increase together with China's import ratio decreasing, these items may have promising export markets. MCA increases of HS7606 and HS8479 are attributable to China's lower import ratio, rather than a higher export share, so higher MCA indices do not guarantee higher export competitiveness for these items.

ALVEOLAR BONE CHANGES AROUND THE NATURAL TEETH OPPOSING THE POSTERIOR IMPLANTS IN MANDIBLE (임플랜트로 수복된 하악 구치부에 대합되는 자연치 주변의 골변화)

  • Jung, Won-Mo;Kim, Dae-Gon;Yi, Yang-Jin;Park, Chan-Jin;Cho, Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.2
    • /
    • pp.263-273
    • /
    • 2007
  • Statement of problem: Alteration of tooth function is assumed to be changed by stress/strain on the adjacent alveolar bone, producing changes in morphology similar to those described for other load-bearing bones. When teeth are removed, opposing teeth will not be functioned. When edentulous area is restored by implant prostheses, opposing teeth will be received physiologic mechanical stimuli. Purpose: The aim of this study was to evaluate the bone changes around the teeth opposing implant restoration installed mandibular posterior area. Material and method: Eight patients who had mandibular posterior edentulous area were treated with implants. Radiographs of the opposing teeth were taken at implant prostheses delivery(baseline), 3 months, and 6 months later. Customized film holding device was fabricated to standardize the projection geometry for serial radiographs of opposing teeth. Direct digital image was obtained. Gray values of region of interest at each digital image were measured and compared according to time lapse. Repeated measured analysis of variance and post-hoc Scheffe's test were performed at the 95% significance level. Results: Alveolar bone changes around the natural teeth opposing the posterior implant in mandible showed statistically significant difference compared to control group(P<0.05). And gray values of alveolar bone around the teeth opposing implants were increased. There were no statistically significant differences of alveolar bone changes between crestal group and middle group and between mesial group and distal group according to time lapse(P>0.05). There were no statistically significant differences of alveolar bone changes among mesial-crestal group, mesial-middle group, distal-crestal group, distal-middle group, and control group(P>0.05). Conclusion: Alveolar bone around the natural teeth opposing the implant prosthesis showed gradual bony apposition.

Biodistribution and Scintigraphy of Iodine-131-Iododeoxyadenosine in Rats Bearing Breast Cancer (흰쥐에서 Iodine-131-Iododeoxyadenosine의 생체분포 및 유방암 영상화에 관한 연구)

  • Kim, Seon-Gu;Kim, Chang-Guhn;Lee, Kang-Mo;Kim, Hye-Won;Min Byung-Cheol;Choi, See-Sung;Lee, Jong-Deuk;Yang, David J.;Kim, E. Edmund;Lee, Hyun-Chul;Won Jong-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.374-381
    • /
    • 1998
  • Purpose: I-131 labeled (2'-deoxy-2'-iodo-${\beta}$-D-arabinofuranosyl) adenine (IAD) may be involved in DNA synthesis during active proliferation of tumor cells. We conducted this study to find out the biodistribution of IAD and it's feasibility for scintigraphic tumor imaging. Materials and Methods: Tosyl acetyl-adenosine was dissolved in acetonitrile, and I-131-NaI was added and heated to synthesize IAD. Female Fisher 344 rats innoculated with breast tumor cells were injected with 0.27 MBq of IAD. Rats were sacrificed at 0.5, 1, 2, 4, 24h and the % of injected dose per gram of tissue (%ID/g) was determined. For scintigraphy, rats bearing breast cancer were administered with 1.11 MBq of IAD and imaging was performed after 2 and 24h. Then, rat body was fixed and microtomized slice was placed on radiographic film for autoradiography. Results: %ID/g of tumor was 0.74 (0.5h),0.73 (1h), 0.55 (2h), 0.38 (4h), and 0.05 (24h), respectively. At 1h after injection, %ID/g of tumor was higher than that of heart (0.34), liver (0.42), spleen (0.47), kidney (0.69), muscle (0.14), bone (0.33) and intestine (0.51). However, %ID/g of tumor was lower than blood (1.06), lung (0.77), and thyroid (177.71). At 4h, %ID/g of tumor in comparison with other tissue did not change. Tumor contrast expressed by tumor to blood ratio was 0.69 and tumor to muscle ratio was 5.11 at 1h. However, these ratios did not improve through 24h. On autoradiogram and scintigraphy at 2 and 24 hour, the tumor was well visualized. Conclusion: This results suggest that IAD may have a potential for tumor scintigraphy. However, further work is needed to improve localization in tumor tissue.

  • PDF