• 제목/요약/키워드: Mo filter

검색결과 193건 처리시간 0.034초

잡음 영상에서의 에지 검출 (Edge detection for noisy image)

  • 구윤모;김영로
    • 디지털산업정보학회논문지
    • /
    • 제8권3호
    • /
    • pp.41-48
    • /
    • 2012
  • In this paper, we propose a method of edge detection for noisy image. The proposed method uses a progressive filter for noise reduction and a Sobel operator for edge detection. The progressive filter combines a median filter and a modified rational filter. The proposed method for noise reduction adjusts rational filter direction according to an edge in the image which is obtained by median filtering. Our method effectively attenuates the noise while preserving the image details. Edge detection is performed by a Sobel operator. This operator can be implemented by integer operation and is therefore relatively fast. Our proposed method not only preserves edge, but also reduces noise in uniform region. Thus, edge detection is well performed. Our proposed method could improve results using further developed Sobel operator. Experimental results show that our proposed method has better edge detection with correct positions than those by existing median and rational filtering methods for noisy image.

유방영상시스템에서 수학적 모의피폭체를 이용한 선량평가 (Dose Evaluation Using Mathematical Simulation of Radiation Exposure Body in Mammography System)

  • 이진수
    • 한국방사선학회논문지
    • /
    • 제8권4호
    • /
    • pp.155-161
    • /
    • 2014
  • 유방촬영의 경우 대부분 양쪽 유방에 대해 연속촬영이 시행되고 있으며, 검사 시 규정하고 있는 3 mGy의 평균유선선량 보다 낮다 하더라도 추가 검사 및 연속촬영으로 인해 실제는 더 많은 선량을 받게 된다. 또한 검사 유방 외에 주변장기선량에 대해 인지하기 어렵다. 이에 본 연구는 유방영상시스템에서 수학적 모의피폭체를 이용하여 필터의 두께 변화(25, 30, $50{\mu}m$)에 따른 주변장기 선량분포와 검사측 유방을 기준으로 한 상대적 흡수선량률을 알아보았다. 그 결과 검사 반대 유방의 선량이 검사 유방을 기준으로 79.26~86.31%정도로 많은 영향이 미치는 것으로 나타났으며, Mo/Mo, W/Rh 조합에서 실제 사용되고 있는 필터 두께 $30{\mu}m$, $50{\mu}m$ 보다 얇은 $25{\mu}m$를 사용했을 때 검사 반대 유방과 주변장기의 상대적 흡수선량률이 낮게 나타났다.

방향성 2차원 타원형 필터를 이용한 스테레오 기반 포즈에 강인한 사람 검출 (Stereo-based Robust Human Detection on Pose Variation Using Multiple Oriented 2D Elliptical Filters)

  • 조상호;김태완;김대진
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제35권10호
    • /
    • pp.600-607
    • /
    • 2008
  • 이 논문은 방향성 2차원 타원형 필터(Multiple Oriented 2D Elliptical Filters;MO2DEFs)를 사용하여 스테레오 영상으로부터 포즈에 강인한 사람 검출을 제안한다. 기존의 물체 지향 크기 적응 필터(Object Oriented Scale Adaptive Filter;OOSAF)는 정면을 보고 있는 사람만을 검출하는 단점을 지니고 있는데 반해 제안한 방향성 2차원 타원형 필터는 사람의 크기나 포즈에 관계없이 사람을 검출하고 추적한다. 2D 공간-깊이 히스토그램에 특정 각도로 향하는 4개의 2차원 타원형 필터들을 적용하고, 필터링 된 히스토그램에서 임계값을 통해서 사람을 검출한 다음, MO2D2EFs 중 승적 결과가 가장 큰 2차원 타원형 필터의 방향을 사람의 방향으로 판단한다. 사람 후보들은 얼굴을 검출하거나 검출된 사람의 선택된 방향의 머리-어께 형태를 정합함으로서 검증한다. 실험 결과는 (1) 포즈 각도 예측의 정확도는 약 88%이고, (2) 제안한 MO2DEFs를 사용한 사람 검출의 성능이 OOSAF를 사용한 사람 검출의 성능보다 $15{\sim}20%$만큼 향상되었으며, 특히 정면이 아닌 사람의 경우에 더 향상이 있었다.

13.56MHz RF시스템에서의 필터 설계 및 시뮬레이션 (Design and Simulation for the Filter of RFID System Operated at 13.56MHz)

  • 류형선;진인수;양경록;송성호;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3145-3147
    • /
    • 2000
  • A passive RFID system consists of reader and tag. Reader is required the filter to modulate the data from backscattering signal which is transmitted by tag. The filter in the reader consists of envelope detector, amplifier, filter, and pulse shaping circuit, In this paper, design and analysis of filter in the RFID system which is operated at l3.56MHz carrier and 70KHz backscattering signal frequency is presented and is confirmed by simulation using Pspice.

  • PDF

유방촬영 시 몬테칼로 전사모사를 이용한 유방 성형 환자의 장기선량 평가 (Assessment of Organ Dose in Mammoplasty Patient by Monte Carlo Simulation during Mammography)

  • 김지수;조용인;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권5호
    • /
    • pp.337-341
    • /
    • 2020
  • Although the screening with a mammography has been shown to be economical, simple and effective in detecting breast cancer, it is accompanied by the risk from radiation. Therefore, this study analyzed the glandular dose and organ dose according to the target-filter combination and the presence and absence of implants using Monte Carlo simulation. The results indicate that at a tube voltage of 30 kV and a tube current of 50 mAs, the dose increased in the order of Mo/Mo. Mo/Rh, Rh/Rh and W/Rh in proportion to the atomic number of the target-filter. In addition, in phantom without implant a reduction in dose was seen when compared to the phantom with implant. The organ dose was highest in the lens except for the breast on the examination side regardless of the presence or absence of the implant. These results may contribute to use basic data for the diagnostic reference level of breast plastic surgery patients.

인버터구동 고압전동기 열화특성 분석 및 필터 설계기법 확립 (Insulation System and Filter Design for Inverter-Fed Motor)

  • 최영찬;이상동;김익모;정명길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.711-713
    • /
    • 2000
  • Recently, the insulation breakdown accident happened at 6.6kV inverter driving motor brings out the reliability decrease to the motor driving system. We need to find the solution with system engineering level. The objectives of this study are developing the appropriate filter for the drive to protect the motor and the insulation system of motor which is driven by inverter. The circuit parameters of cable are calculated by EMTP(Electromagnetic Transient Program) to simulate the system. And we use MATLAB to find the appropriate filter parameter. The simulation and the test results are compared to verify the suitability of the filter parameter. We clarify the cause of the deterioration of the inverter driving motor through the analysis of insulation breakdown accidents. The endurance test scheme and the configuration method of insulation system are established.

  • PDF

A Finite Memory Filter for Discrete-Time Stochastic Linear Delay Systems

  • Song, Il Young;Song, Jin Mo;Jeong, Woong Ji;Gong, Myoung Sool
    • 센서학회지
    • /
    • 제28권4호
    • /
    • pp.216-220
    • /
    • 2019
  • In this paper, we propose a finite memory filter (estimator) for discrete-time stochastic linear systems with delays in state and measurement. A novel filtering algorithm is designed based on finite memory strategies, to achieve high estimation accuracy and stability under parametric uncertainties. The new finite memory filter uses a set of recent observations with appropriately chosen initial horizon conditions. The key contribution is the derivation of Lyapunov-like equations for finite memory mean and covariance of system state with an arbitrary number of time delays. A numerical example demonstrates that the proposed algorithm is more robust and accurate than the Kalman filter against dynamic model uncertainties.