• 제목/요약/키워드: Mixing vane

검색결과 79건 처리시간 0.028초

Mixing Vane Effect on the Critical Heat Flux

  • Ahn, Seung-Hoon;Kim, Hyong-Chol;Koo, Bon-Hyun
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 춘계학술발표회논문집(1)
    • /
    • pp.316-321
    • /
    • 1997
  • The mixing vane effect on the Critical Heat Flux (CHF) is discussed with focus on the vortex now effect. In the subchannel approach, this effect is not quantified by the calculation model, but directly taken into account by the CHF correlation itself through data analysis. The vortex now effect is identified the two Westinghouse correlations, and then the CHF margin issue given rise to by the Vantage-5H design change is evaluated and discussed. It is noted that deficiency about CHF dependency on the vortex flow effect could induce an error in the Departure from Nucleate Boiling Ratio (DNBR) sensitivity Calculation.

  • PDF

베인 타입 스태틱 믹서의 기하학적 변수에 따른 디젤 배기관 내 유동특성에 관한 연구 (Numerical Study of the Flow Characteristics in a Diesel Exhaust System with a Vane-Type Static Mixer)

  • 강경남;이지근;김만영
    • 대한기계학회논문집B
    • /
    • 제36권4호
    • /
    • pp.397-404
    • /
    • 2012
  • 디젤엔진 SCR 시스템 내에서 $NO_x$를 저감을 위한 베인 타입 스태틱 믹서의 혼합유동특성을 수치적으로 연구하였다. 믹서는 원형관의 입구로부터 유동방향으로 직경의 57배 떨어진 구간에 설치하였다. 베인이 유동 축과 이루는 각과 베인의 크기 그리고 위치의 변화에 따른 유동 및 혼합특성을 고찰하였다. 원형관내에서 믹서를 통과하는 유동의 특성은 UI, 선회비, 그리고 압력계수와 같은 특성화된 성능지수로 나타내었다. 해석결과 성능지수들은 베인 각과 차단비, 베인 위치와 같은 기하학적 변수에 영향을 받음을 확인하였다. 특히, 베인 각, 베인 크기가 커지거나 원형관내의 벽면에 가까이 설치될수록 선회비는 증가하는 것을 확인하였다.

복합혼합날개를 장착한 5${\times}$5 봉다발에서 부수로 혼합 및 임계열유속 실험 연구 (Experimental Study on the Thermal Mixing and the Critical Heat Flux in the 5${\times}$5 Rod Bundle with the Hybrid Mixing Vane)

  • 강경호;신창환;추연준;윤영중;박종국;문상기;천세영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2303-2308
    • /
    • 2007
  • Experiments were performed to determine the thermal (or turbulent) diffusion coefficient (TDC) and to investigate the critical heat flux (CHF) performance in the 5${\times}$5 rod bundle with 5 unheated rods which are supported by Hybrid Mixing Vane. In this study, HFC-134a fluid was used as working fluid and the fluid temperature were measured in the important subchannels. To determine the TDC value, the measured fluid temperatures were compared with the predicted values obtained from the MATRA code. The best optimized value of ${\beta}$ was found to be 0.02 by considering prediction statistics, i.e., average and standard deviations of the differences between the experimental results and code calculations. Using the best optimized value of ${\beta}$ as 0.02, the MATRA code predicts the test results of the fluid temperature within ${\pm}$1.0 % of error. According to the experimental results on CHF of 5 non-heating guide tubes, the case with non-heating guide tube showed a little good performance in terms of CHF.

  • PDF

EFFECTS OF GRID SPACER WITH MIXING VANE ON ENTRAINMENTS AND DEPOSITIONS IN TWO-PHASE ANNULAR FLOWS

  • KAWAHARA, AKIMARO;SADATOMI, MICHIO;IMAMURA, SHOGO;SHIMOHARAI, YUTA;HIRAKATA, YUDAI;ENDO, MASATO
    • Nuclear Engineering and Technology
    • /
    • 제47권4호
    • /
    • pp.389-397
    • /
    • 2015
  • The effects of mixing vanes (MVs) attached to a grid spacer on the characteristics of air-water annular flows were experimentally investigated. To know the effects, a grid spacer with or without MV was inserted in a vertical circular pipe of 16-mm internal diameter. For three cases (i.e., no spacer, spacer without MV, and spacer with MV), the liquid film thickness, liquid entrainment fraction, and deposition rate were measured by the constant current method, single liquid film extraction method, and double liquid film extraction method, respectively. The MVs significantly promote the re-deposition of liquid droplets in the gas core flow into the liquid film on the channel walls. The deposition mass transfer coefficient is three times higher for the spacer with MV than for the spacer without MV, even for cases 0.3-m downstream from the spacer. The liquid film thickness becomes thicker upstream and downstream for the spacer with MV, compared with the thickness for the spacer without MV and for the case with no spacer.

이중냉각 환형핵연료 집합체를 위한 비틀림 혼합날개 지지격자의 강제대류열전달 성능 검토 (Examination of Forced Convection Heat Transfer Performance of a Twist-Vane Spacer Grid for a Dual-Cooled Annular Fuel Assembly)

  • 이치영
    • 대한기계학회논문집B
    • /
    • 제41권1호
    • /
    • pp.53-62
    • /
    • 2017
  • 이중냉각 환형핵연료 집합체를 위한 비틀림 혼합날개 지지격자의 강제대류열전달 성능을 실험적으로 평가하였다. 비틀림 혼합날개 지지격자는 부수로 간 혼합뿐 아니라 부수로 내 혼합을 동시에 증대시킬 수 있도록 설계되었다. 실험을 위한 이중냉각 환형핵연료 모의 집합체로, 봉 중심 간 거리와 봉 외경의 비가 1.08인 봉 간격이 좁은 $4{\times}4$ 정사각 배열의 봉다발을 준비하였다. 실험은 봉다발 유동의 축방향 평균속도가 1.5 m/s, 열유속은 $26kW/m^2$인 조건에서 수행하였다. 원주방향 온도 분포의 경우, 지지격자 상류에서는 부수로 중심 벽면에서, 하류에서는 비틀림 혼합날개 끝이 향하는 벽면에서 온도가 가장 낮게 나타났다. 축방향 온도 분포의 경우, 지지격자 하류 근처에서 온도가 급격하게 감소하는 것으로 측정되었고, 비틀림 혼합날개에 의해 누셀트 수는 최대 56 % 증대되는 것으로 나타났다. 본 실험결과를 토대로 봉 간격이 좁은 이중냉각 환형핵연료 집합체에서 비틀림 혼합날개 지지격자에 의해 강제대류열 전달 성능이 효과적으로 증대될 수 있음을 확인하였다.