• 제목/요약/키워드: Mixed system

검색결과 3,640건 처리시간 0.038초

FAST 시스템에 의한 신사복지의 외관성능 평가 (Evaluation of Appearance Capacity of Fabrics for Men's Suit by FAST System)

  • 김정숙
    • 한국의류산업학회지
    • /
    • 제8권5호
    • /
    • pp.591-596
    • /
    • 2006
  • In order to analyze the tailorbility of different fabrics for men's suit, FAST system has been used for measuring the distribution of mechanical properties in this study. As results, cashmere mixed woolen fabrics showed the minimum degree in relaxation shrinkage, formability, and shear rigidity than any other fabrics, and also showed more than 6% as maximum level of extensibility. Thus, cashmere mixed woolen fabrics requires careful tailoring in lay-out, marking, and cutting. It is necessary to establish new tailoring criteria for automatic sewing with cashmere mixed woolen fabrics than any other fabrics, because they show more failure rate of tailorbility. There have been noticeably more variation of shrinkage and extension for woolen fabrics with cashmere mixed than 100% woolen fabrics by evaluating the formability of the suits when these are completed to suits through cutting and tailoring from fabrics. Especially nylon mixed woolen fabrics showed shrinkage overall, but polyester mixed woolen fabrics showed extension at waist area. Thus, it is necessary to adjust the appropriate overfeed rate considering the amount of shrinkage and extension while tailoring.

500 PS SCR 반응기 혼합증발관 길이와 각도 변화에 따른 유동균일도에 대한 수치해석적 연구 (A Study on Numerical Analysis of Flow Uniformity According to Length and Degree Change of Mixed-Evaporator in 500 PS SCR Reactor)

  • 성홍석;이충호;서정세
    • 설비공학논문집
    • /
    • 제28권8호
    • /
    • pp.337-342
    • /
    • 2016
  • A marine SCR System is emerging as an alternative to comply with NOx Tier III Emission standards, a restriction on greenhouse gas from vessels implemented by the International Maritime Organization. The system is greatly affected by the uniformity of the fluid flowing into the catalyst, so the performance of the catalyst of an SCR system needs to be guaranteed. This study conducted research on a mixed evaporator of an SCR system, which is one of the factors affecting the uniformity of the fluid. When the angle of the mixed evaporator is set to $90^{\circ}$, the fluid uniformity is at its highest at 83%, under the condition that the length of the mixed evaporator be 3.5 D. When the length was 3.5 D and less, the fluid uniformity had a tendency to improve relative to the case without a bent pipe. However, a longer mixed evaporator results in a more perfect liquidity development in the pipe with a liquidity distribution similar to the case where no curved pipe is formed in front of the catalyst. A lower angle for the mixed evaporator results in a lower flow uniformity, and a longer length of the mixed evaporator results in a lower difference in the flow uniformity caused by the angle. The flow uniformity can be improved by 6% with a mixed evaporator, which confirmed that all factors applied to an SCR system have a close relationship with the efficiency.

ASYMPTOTIC STUDY OF MIXED ROTATING MHD SYSTEM

  • Selmi, Ridha
    • 대한수학회보
    • /
    • 제47권2호
    • /
    • pp.231-249
    • /
    • 2010
  • Asymptotic behavior of three-dimensional mixed, periodic and rotating magnetohydrodynamic system is investigated as the Rossby number goes to zero. The system presents the difficulty to be singular and mixed, that is hyperbolic in the vertical direction and parabolic in the horizontal one. The divergence free condition and the spectral properties of the penalization operator are crucial in the proofs. The main tools are the energy method, the Schochet's method and products laws in anisotropic Sobolev spaces.

혼합 공조 시스템의 EER(A) 평가 (Evaluation of energy efficiency ratio in the mixed air conditioner system)

  • 김병순;이승홍
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.542-548
    • /
    • 1999
  • Instead of testing split air conditioners, an empirically based calculation procedure may be used to estimate the Energy Efficiency Ratio at ARI A test conditions. Typically, the system involving the indoor unit well sold and the given outdoor unit is called the matched system. All other systems involving a given outdoor unit and other indoor units are called the mixed systems. To estimate the EER(A) for the mixed systems, EER(A) for the matched system must be known, Generally, the EER(A) for the matched system is known. This procedure relies on independent measurements and calculations made on an outdoor unit in conjunction with a matched indoor and a mixed indoor coil. A heat pump simulation model was used to quantify the effects of individual system components on the system performance. The procedure is applicable to all air-conditioning units having rated cooling capacities less than 19,000W and charged with refrigerant 22.

  • PDF

THE RIEMANN PROBLEM FOR A SYSTEM OF CONSERVATION LAWS OF MIXED TYPE (II)

  • Lee, Choon-Ho
    • 대한수학회논문집
    • /
    • 제13권1호
    • /
    • pp.37-59
    • /
    • 1998
  • We prove that solutions $u^\epsilon$ for the mixed hyperbolic-elliptic system of conservation laws with the viscosity term are total variation bounded uniformly in $\epsilon$ and that the solution $u^\epsilon$ converges to the solution for the mixed hyperbolic-elliptic Riemann problem as $\epsilon \to 0$.

  • PDF

A NEW SYSTEM OF GENERALIZED NONLINEAR MIXED QUASIVARIATIONAL INEQUALITIES AND ITERATIVE ALGORITHMS IN HILBERT SPACES

  • Kim, Jong-Kyu;Kim, Kyung-Soo
    • 대한수학회지
    • /
    • 제44권4호
    • /
    • pp.823-834
    • /
    • 2007
  • We introduce a new system of generalized nonlinear mixed quasivariational inequalities and prove the existence and uniqueness of the solution for the system in Hilbert spaces. The main result of this paper is an extension and improvement of the well-known corresponding results in Kim-Kim [16], Noor [21]-[23] and Verma [24]-[26].

The effect of an EML sequence and an interlayer on the performance of the phosphorescent-fluorescent mixed WOLEDs

  • Baek, Heume-Il;Lee, Chang-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1215-1218
    • /
    • 2008
  • We investigate the effect of a light emitting layer (EML) sequence and an interlayer on the performance of the phosphorescent-fluorescent mixed white organic light emitting diodes. Two types of phosphorescent-fluorescent mixed system were evaluated. The proper position of each primary color EML was crucial to obtain best performance in each system whereas the effect of an interlayer was found to be different in both systems.

  • PDF

비행 VR 시뮬레이터를 위한 혼합 현실 환경의 구축 (Building Mixed Reality System for a VR Flight Simulator)

  • 이종환;한순흥
    • 한국시뮬레이션학회논문지
    • /
    • 제13권2호
    • /
    • pp.45-52
    • /
    • 2004
  • This paper presents a prototype visualization system of mixed reality for a VR flight simulator. The chroma key technique is used to build the mixed reality model for a VR flight simulator. The Daedeok science town can be visualized in real time according to the rider control. He can also see his own hand/foot operating the control stick/rudder as well as virtual environment projected to the blue-screen using a video-see-through HMD.

  • PDF

중국 전문대학의 혼합소유제 개혁에 관한 연구 (A Study on the Mixed Ownership Reform in Vocational Colleges in China)

  • 조원;임령;이도
    • 디지털융복합연구
    • /
    • 제20권1호
    • /
    • pp.87-94
    • /
    • 2022
  • 중국 직업대학의 혼합소유제 개혁은 직업교육 발전의 중요한 원동력이다. 본 논문의 목적은 중국 직업교육개혁의 지침에 따라 현 단계의 전문대학 혼합소유제 개편의 운영방향을 논의하는 것이다. 따라서 본 연구는 문헌연구방법을 활용하여 전문대학의 혼합소유제 개혁의 필요성과 존재하는 문제점을 분석하였다. 연구결과, 전문대학의 혼합소유제 개혁은 법률지원, 인센티브 제공, 평가제도 개선 등 측면에서 대책을 마련하여 지속적으로 발전시켜야 한다는 것을 발견하였다. 본 연구는 중국 전문대학의 혼합소유제 개혁의 필요성을 시사하고 문제점을 분석하였으며 정책적 대책을 마련하였다는 점에서 학술적×실무적 의의가 있다.

하중 혼합감도함수를 이용한 RTP 시스템의 견실제어기 설계 (Robust controller design for RTP system using weighted mixed sensitivity minimization)

  • 이상경;오도창;박홍배
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.434-437
    • /
    • 1997
  • In this paper, we present an $H^{\infty}$ controller design of RTP system satisfying robust stability and performance using weighted mixed sensitivity minimization. In industrial fields, RTP system is widely used for improving the oxidation and the annealing in semiconductor manufacturing process. The main control factors are temperature control of wafer and uniformity in the wafer. The control of temperature and uniformity has been solved by PI control method. We improve robust stability and performance of RTP system by the design of $H^{\infty}$ controller using the weighted mixed sensivity function. An example is proposed to show the validity of proposed method.d.

  • PDF