• Title/Summary/Keyword: Mixed load

Search Result 465, Processing Time 0.028 seconds

A Study for Evaluation of Hot Mixed Asphalt Mixtures with Tack-Coat Regarding High-Frequency Dynamic Resistance Performance and Bonding Property (택코트 첨가 가열아스팔트 혼합물의 고주파 동적저항 특성 및 접착성능 평가에 대한 연구)

  • Kim, Dowan;Mun, Sungho
    • International Journal of Highway Engineering
    • /
    • v.17 no.3
    • /
    • pp.35-47
    • /
    • 2015
  • PURPOSES : A tack coat has been utilized to increase the bond performance between the surface layer and base course (intermediate course) at various road pavement sites. This is similarly true in other nations. Based on this connection, the objective of the present study is to evaluate the properties of hot mix asphalt (HMA) mixtures with an RSC-4 or BD-Coat and determine the application rate of the tack coat. METHODS : The HMA specimens were manufactured using superpave gyratory compaction. The HMA mixtures were composed of a 5-cm thick surface layer and a 10-cm thick base course. An impact hammer resonance test (IHRT) and a static load shear test were conducted to evaluate the performance of the HMA mixtures with a tack coat. From these tests, the dynamic moduli related to the high-frequency resistance and interlayer shear strength (ISS) of HMA could be obtained. RESULTS : The results of the dynamic moduli of HMA are discussed based on the resonance frequency (RF). To check the accuracy of the IHRT, we conducted a coherence analysis. A direct shear test using the application of a static load test was carried out to evaluate the interlayer shear strength (ISS) of HMA. CONCLUSIONS : The maximum ISS was demonstrated at an RSC-4 application rate of 462 gsm, and the maximum dynamic modulus was demonstrated at an RSC-4 application rate of 306 gsm. By averaging the results of the ISS, the maximum ISS values were obtained when a BD-Coat application rate of 602 gsm was applied.

Simple Material Budget Modeling for the Paldang Reservoir in the Spring Season (팔당호의 춘계 단순물질수지 모델링)

  • Kong, Dongsoo
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.6
    • /
    • pp.696-714
    • /
    • 2017
  • Simple material budget models were developed to predict the spring season (March ~ May) water quality for a river-type reservoir Paldang, in the Republic of Korea. These models are available at mixed water bodies whose light intensity is negligible at the bottom. The calculated data from the models fit quite well with field data collected for 30 years, from 1988 to 2017. The apparent settling velocity of total phosphorus was estimated to be $110m\;d^{-1}$. The critical hydraulic load that determines the usability of phosphorus for algal production appeared to be about $2.0m\;d^{-1}$. When a hydraulic load was larger than the critical value, the concentrations of chlorophyll ${\alpha}$ ($Chl.{\alpha}$), chemical oxygen demand (COD), and 5-day biochemical oxygen demand BOD in the reservoir water became insensitive to internal algal reactions. The model analysis showed that the allochthonous COD continued to increase while the allochthonous BOD slightly decreased after 1999. The decrease of allochthonous BOD is due to the expansion of sewage and wastewater treatment plants in the watershed. The increase of allochthonous COD seems to result from the increase in anthropogenic non-point sources as well as the increase in the discharge of natural organic matters due to climate change. Organic matter of algal origin continued to increase until the mid-2000s, but recently it has decreased as the phosphorus concentration has decreased. The COD and BOD of algal origin increased from 35 % and 27 % during 1988 ~ 1994 to 43 % and 40 % during 2000 ~ 2010, respectively, and then decreased to 25 % and 28 % during 2011 ~ 2017.

Correlation between operation factors and nitritation using anaerobic digester supernatant at ordinary temperature (상온 조건에서 혐기 소화 상징액을 이용한 아질산화 반응과 운전 인자의 상관성 분석)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.18 no.3
    • /
    • pp.244-249
    • /
    • 2016
  • Anaerobic digester supernatant including high concentrations of nitrogen is recycled to water treatment line and make pollutant load increase in municipal wastewater treatment plant(MWTP). To treat nitrogen in anaerobic digester supernatant is suggested the method of MWTP retrofit. In this study, the lab scale reactor was operated about 200 days using supernatant of anaerobic digester. The results could draw operation condition that ammonium nitrogen removal efficiency more than 90% and nitrite conversion efficiency over 70%. Correlation between operation efficiency and operation factors was analyzed based on the operation results. Ammonium nitrogen remove efficiency and nitrite conversion efficiency were related to solid retention time (SRT), ammonium nitrogen load and ammonium nitrogen loading per unit mixed liquer suspended solid (MLSS). Results of this study can be used effective data on nitritation of supernatant of anaerobic digester, and be expected to increase availability of nitritation.

Blood Triglycerides Levels and Dietary Carbohydrate Indices in Healthy Koreans

  • Min, Hye Sook;Kang, Ji Yeon;Sung, Joohon;Kim, Mi Kyung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.49 no.3
    • /
    • pp.153-164
    • /
    • 2016
  • Objectives: Previous studies have obtained conflicting findings regarding possible associations between indices measuring carbohydrate intake and dyslipidemia, which is an established risk factor of coronary heart disease. In the present study, we examined crosssectional associations between carbohydrate indices, including the dietary glycemic index (GI), glycemic load (GL), total amount of carbohydrates, and the percentage of energy from carbohydrates, and a range of blood lipid parameters. Methods: This study included 1530 participants (554 men and 976 women) from 246 families within the Healthy Twin Study. We analyzed the associations using a generalized linear mixed model to control for familial relationships. Results: Levels of the Apo B were inversely associated with dietary GI, GL, and the amount of carbohydrate intake for men, but these relationships were not significant when fat-adjusted values of the carbohydrate indices were used. Triglyceride levels were positively associated with dietary GI and GL in women, and this pattern was more notable in overweight participants (body mass index [BMI] ${\geq}25kg/m^2$). However, total, low-density lipoprotein and high-density lipoprotein cholesterol levels were not significantly related with carbohydrate intake overall. Conclusions: Of the blood lipid parameters we investigated, only triglyceride levels were positively related with dietary carbohydrate indices among women participants in the Healthy Twin Study, with an interactive role observed for BMI. However, these associations were not observed in men, suggesting that the association between blood lipid levels and carbohydrate intake depends on the type of lipid, specific carbohydrate indices, gender, and BMI.

Priority Based Medium Access Control and Load Balancing Scheme for Shared Situational Awareness in Airborne Tactical Data Link (공중 전술 데이터링크에서 상황인식 공유를 위한 우선순위 기반 매체접속제어와 부하분산 기법)

  • Yang, Kyeongseok;Baek, Hoki;Park, Kyungmi;Lim, Jaesung;Park, Ji Hyeon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.10
    • /
    • pp.1210-1220
    • /
    • 2016
  • As modern warfare has changed into network centered, the ability to share situational awareness among allies become a core competency for performing operational missions. In an airborne environment, it uses a tactical data link such as Link-16 for shared situational awareness. There exist problems when it shares situational awareness over the existing data link that can not allocate slots dynamically or that can not change the number of a slot to be allocated. In addition, there was a problem that can not share this failure so that failed to improves situation awareness because of finite time slot resources. In this paper, we accommodate dynamic slot allocation and changes of slot allocation with mixed structure of TDMA (time division multiple access) and random access. We propose a technique that can be used when available slots are exhausted, and a load balancing method to prevent slot allocation delay when slot requesting or message sending is concentrated on a single subframe.

Investigation of shear behavior of soil-concrete interface

  • Haeri, Hadi;Sarfarazi, Vahab;Zhu, Zheming;Marji, Mohammad Fatehi;Masoumi, Alireza
    • Smart Structures and Systems
    • /
    • v.23 no.1
    • /
    • pp.81-90
    • /
    • 2019
  • The shear behavior of soil-concrete interface is mainly affected by the surface roughness of the two contact surfaces. The present research emphasizes on investigating the effect of roughness of soil-concrete interface on the interface shear behavior in two-layered laboratory testing samples. In these specially prepared samples, clay silt layer with density of $2027kg/m^3$ was selected to be in contact a concrete layer for simplifying the laboratory testing. The particle size testing and direct shear tests are performed to determine the appropriate particles sizes and their shear strength properties such as cohesion and friction angle. Then, the surface undulations in form of teeth are provided on the surfaces of both concrete and soil layers in different testing carried out on these mixed specimens. The soil-concrete samples are prepared in form of cubes of 10*10*30 cm. in dimension. The undulations (inter-surface roughness) are provided in form of one tooth or two teeth having angles $15^{\circ}$ and $30^{\circ}$, respectively. Several direct shear tests were carried out under four different normal loads of 80, 150, 300 and 500 KPa with a constant displacement rate of 0.02 mm/min. These testing results show that the shear failure mechanism is affected by the tooth number, the roughness angle and the applied normal stress on the sample. The teeth are sheared from the base under low normal load while the oblique cracks may lead to a failure under a higher normal load. As the number of teeth increase the shear strength of the sample also increases. When the tooth roughness angle increases a wider portion of the tooth base will be failed which means the shear strength of the sample is increased.

Micro-silica Mixed Aqua-epoxy for Concrete Module Connection in Water : Part 2 - Structural Application and Evaluation (해상 프리캐스트 콘크리트 부유체 모듈 가접합을 위한 마이크로 실리카 혼입 수중용 에폭시 접합 성능 검토 : Part 2 - 구조 접합 성능 평가)

  • Choi, Jin-Won;You, Young-Jun;Jeong, Youn-Ju;Kwon, Seung-Jun;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.1
    • /
    • pp.29-35
    • /
    • 2015
  • Recent studies to develop Very Large Floating Structure(VLFS) has shown that the construction procedure of the structure needs to acquire precast concrete module connection system using prestressing. However, the loads occurring on water are complex combinations of various condition, so the safe and stable performance of the module joints and bonding materials are key to the success of the construction. Therefore, micro-silica mixed aqua-epoxy development was introduced in Part 1 using a bonding material developed in this study. The performance of the micro-silica mixed aqua-epoxy(MSAE) applied joint of concrete module specimens connected by prestressing tendon was evaluated to verify the usability and safety of the material. RC beam, spliced beam connected by prestressing tendon and MSAE, and continuous prestressed concrete beam were tested for their initial cracking and maximum loads as well as cracking procedure and pattern. The results showed that the MSAE can control the stress concentration effect of the shear key and the crack propagation, and the maximum load capacity of MSAE joint specimens are only 5% less than that of continuous RC specimen. The details of the study are discussed in detail in the paper.

Review of Minimum Curve Radius and Cant Range Setting for Mixed Section of Low and High speed Trains in Conventional Railway Line (일반철도의 저속 및 고속열차 혼용구간 최소곡선반경 및 설정캔트범위 검토)

  • Lee, Jae-Hyuk;Kim, Jeong-Hyeok;Park, Young-Gul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.345-353
    • /
    • 2020
  • On conventional railway lines, trains with different speeds are operated. Therefore, trains moving on curved sections with cants must accept various ranges of balanced cants, cant deficiency, and cant excess, which is essential for the comfort and safety of train operation. In this study, the correlation between the curve radius, cant, and train speed on a track was analyzed to check the cant range that satisfies the criteria of train types, operation speed, cant deficiency, and cant excess. Also, the range of setting the cant by the curve radius and balanced cant were calculated by a regression analysis of train speed according to the frequency of operation in the case of mixed trains. The results could make it possible to improve the speed of the operation route, reduce the loss of ride quality, reduce the risk of derailing caused by cant deficiency, and minimize the load deflection by excess cant. This will ensure the safety of trains running on curves and improve the efficiency of track maintenance.

Establishment of Plasma Working Standards for the Performance and Quality Assurance of NAT Screening Tests for HIV, HCV and HBV (HIV, HCV와 HBV 유전자 분석시약의 성능 및 품질관리용 Plasma Working Standards 제조에 관한 연구)

  • Kim, Myung Han;Cho, Youn Jung;Kwon, So-Yong;Cho, Nam Sun
    • The Korean Journal of Blood Transfusion
    • /
    • v.23 no.2
    • /
    • pp.152-161
    • /
    • 2012
  • Background: Since Jan. 2012, for performance evaluation of viral reagents, analysis of domestic samples has been recommended in order to obtain approval from the KFDA when they are first introduced to Korea. This regulation requires the standard domestic materials driven from locally infected samples. We tried manufacturing the plasma working standards of HBV, HCV, and HIV NAT using a mixed titer of viral loads. Methods: Forty three HBV DNA positive plasmas, 25 HCV RNA positive plasmas, and 26 HIV RNA positive plasmas were evaluated according to viral load and genotype. Several plasma units, which had high-titer viral loads and the common viral genotypes in Korea, were selected as the source materials for each viral standard. To adjust the appropriate concentration based on the detectable range of variable viral reagents, the source plasma was diluted to several concentrations, divided into small vials, and analyzed for quantification. Results: The 13 plasma working standards, which had variable viral loads for the mixed titer performance panel of HIV, HCV, and HBV NAT, were produced. Conclusion: These national standard materials were first produced in order to supply the mixed titer performance panel for the viral NAT reagent of the level IV transfusion related high-risk group in Korea.

Performance Enhancement of Solar Thermal Storage Tank with Heat Exchange Coils (Part 1 : Verification Experiment) (열교환코일 내장형 태양열 축열조의 성능향상 (제1보 실증실험))

  • Lee, Uk-Jae;Hong, Hiki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.213-219
    • /
    • 2015
  • A thermal storage tank with internal heat exchange coils is commonly used in solar thermal systems with a collector area below $100m^2$. The coils are installed in the lower part of the tank because the temperature of the upper part of the tank can drop if the outlet temperature of the collector becomes lower than the upper temperature of the tank, which is a kind of temperature reversal. As an alternative to the well-mixed storage tank with lower coil only, we have proposed a tank with lower and upper coils and have achieved superior thermal stratification in the tank, which results in increased collector efficiency and solar fraction. But, the phenomenon of temperature reversal was often observed in the tank when the load or solar radiation changed rapidly. In the present work, revised control was successfully applied, i.e., to heat only the lower coil using a three way valve if temperature reversal occurs and to operate the collector at a low flow rate when the quality of solar radiation is not good.