• Title/Summary/Keyword: Mixed Building Structure

Search Result 102, Processing Time 0.024 seconds

A study of the Method on the Packing ability of Concrete Filled in Steel Tube Structure by High Strength and High Flowable Concrete (고강도 고유동 콘크리트를 이용한 콘크리트충전강관(CFT)구조의 충전성에 관한 공법 연구)

  • Kang, Yong-Hak;Jung, Keun-Ho;Lim, Nam-Ki;Lee, Young-Do;Jung, Jae-Young;Jung, Sang-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.1
    • /
    • pp.163-169
    • /
    • 2002
  • In this study, there are kind of property experiments like fluidity, compressive strength, bleeding measurement, concrete sink for CFT use high fluidity concrete. The property difference between before transmit and after transmit concrete in the mock up test with ready mixed concrete equipment is examined. The variable factors in mock up are diaphragm existence and nonexistence, diaphragm placing hole sizes. To investing the concrete Property under diaphragm, concrete packing ability, hydration heat, core specimen strength tests are performed.

Fabrication of Ordered or Disordered Macroporous Structures with Various Ceramic Materials from Metal Oxide Nanoparticles or Precursors

  • Cho, Young-Sang;Moon, Jun-Hyuk;Kim, Young-Kuk;Choi, Chul-Jin
    • Journal of Powder Materials
    • /
    • v.18 no.4
    • /
    • pp.347-358
    • /
    • 2011
  • Two different schemes were adopted to fabricate ordered macroporous structures with face centered cubic lattice of air spheres. Monodisperse polymeric latex suspension, which was synthesized by emulsifier-free emulsion polymerization, was mixed with metal oxide ceramic nanoparticles, followed by evaporation-induced self-assembly of the mixed hetero-colloidal particles. After calcination, inverse opal was generated during burning out the organic nanospheres. Inverse opals made of silica or iron oxide were fabricated according to this procedure. Other approach, which utilizes ceramic precursors instead of nanoparticles was adopted successfully to prepare ordered macroporous structure of titania with skeleton structures as well as lithium niobate inverted structures. Similarly, two different schemes were utilized to obtain disordered macroporous structures with random arrays of macropores. Disordered macroporous structure made of indium tin oxide (ITO) was obtained by fabricating colloidal glass of polystyrene microspheres with low monodispersity and subsequent infiltration of the ITO nanoparticles followed by heat treatment at high temperature for burning out the organic microspheres. Similar random structure of titania was also fabricated by mixing polystyrene building block particles with titania nanoparticles having large particle size followed by the calcinations of the samples.

An Experimental Study on Freezing-Thawing and Mechanical Properties of Lightweight Foamed Concrete Using Micro Foaming Agent (기포제를 사용한 경량 콘크리트의 역학적 특성 및 동결융해 평가에 관한 실험적 연구)

  • Min, Tae-Beom;Woo, Young-Je;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.69-72
    • /
    • 2009
  • This research is focused on the applying of the foaming agent which can make the independent pore in the concrete structure in order to make a lightweight concrete structure. This lightweight foamed concrete can satisfy both the required strength and the mechanical properties as structural members. In addition, anti freezing-thawing properties also required. As a result of the unit volume-weight measurement, when the foaming agent mixed at 0.5% to 1%, the lightweight foamed concrete can be applied for the structural member. Also the density and compressive strength measurement results reveals that it will be suitable as structural member with 21MPa strength, when the density is betweenity8 to 1.9 and foaming agent quantities are 0.5% to 1%. Finally the result of freezing-thawing experiment, the effect freezing-thawing damage reduced according to adding foaming agent because those foaming agent make micro-pores in the structure which are not seen in the ordinary concrete structure.

  • PDF

Pore Structure and Fractal Characters of Cement Mortar Containing γ-C2S (γ-C2S 혼입 시멘트 모르타르의 공극구조 및 Fractal특성)

  • Chen, Zheng-Xin;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.24-25
    • /
    • 2017
  • Gamma-C2S (γ-C2S) is a substance that is difficult to react with water under normal temperature but can absorb a large amount of CO2 in the air. The addition of γ-C2S to cementitious materials through the curing of CO2 can improve the pore structure and improve the durability of the material. In this study, three kind of Ca-bearing materials : CaO, Ca(OH)2, CaCO3, were calcined 2.5h at 1450℃ to synthesize γ-C2S after mixing with SiO2 respectively. Among them, Ca(OH)2 mixed with SiO2 after calcining shows highest content. Synthesized γ-C2S was added to the cement mortar, after water curing for 1 month, accelerated carbonation test was experimented. After 28d accelerated carbonation test, pore structure will be detectived by MIP. Based on the MIP result, following the calculation method of Fractal theory, the pore structure will be quantitative described.

  • PDF

Evaluation of vibration damping rate performance according to polymer mixing rate of polymer mixed mortar through ultrasonic pulse analysis (초음파 펄스 분석을 통한 폴리머 혼입 모르타르의 폴리머 혼입률에 따른 진동감쇠율 성능 평가)

  • Jeong, Min-Goo;Jang, Jong-Min;Lee, Gwang-Su;Lee, Han-Seung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.71-72
    • /
    • 2022
  • In this paper, the performance evaluation of the vibration damping ratio according to the polymer mixing ratio of the polymer modified mortar used as the floor finishing material of the apartment building structure was evaluated. To compare the vibration damping rate, ordinary potland cement (OPC) mortar and polymer modified mortar (PMM) were prepared. In addition, the mixed polymer was mixed with Styrene Butadiene Rubber (SBR) liquid polymer with a solid content of about 49%. Accordingly, the W/C of the test specimen was adjusted and compounded, and the experiment was conducted by mixing 5 types of the test specimen: OPC-60, PMM-5%, PMM-10%, PMM-15%, and PMM-20%. In addition, in order to adjust the W/C of the specimen, the fluidity of each specimen was set as 210 (±5) mm. The specimens measured density and flow in fresh mortar and after curing for 28 days, flexural strength, compressive strength and ultrasonic pulse were measured. The attenuation rate was shown. The experimental results showed that the density increased according to the mixing of the polymer, the flexural strength increased as the mixing rate of the polymer increased, and the compressive strength was decreased. In addition, it was shown that the vibration damping rate increases with the increase in the amount of polymer incorporated.

  • PDF

Microbiological Contamination in Office Buildings by Work Space Structure (사무공간 구조에 따른 실내공기 중 생물학적 오염분포 특성)

  • Won, Dong-Hwan;Huh, Eun-Hae;Jeong, Ho-Chul;Moon, Kyong-Whan
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.3
    • /
    • pp.213-222
    • /
    • 2012
  • Objectives: This study was undertaken in order to evaluate by work space zoning and structure the concentrations of biological contaminants in the indoor air of domestic office buildings. Methods: Air samples were collected in the office spaces of 15 office buildings in Seoul from June 28 to July 28, 2011. Prior to the sampling, each office was classified into 'open-plan office', 'cellular office' and 'mixed office' according to the work space zoning. To evaluate the biological contamination of indoor air, total suspended bacteria (TSB), Gram positive bacteria (GPB), Staphylococcus aureus (S.A), Methicillin-resistant Staphylococcus aureus (MRSA), Gram negative bacteria (GNB) and fungi were investigated. During the sampling, temperature, relative humidity and carbon dioxide ($CO_2$) were measured. Results: The TSB concentrations ($GM{\pm}GSD$) were $452({\pm}1.3)cfu/m^3$ in open-plan offices, $366({\pm}1.3)cfu/m^3$ in cellular offices and $287({\pm}1.5)cfu/m^3$ in mixed offices, and there were significant differences between the three groups (p<0.05). The highest concentrations ($GM{\pm}GSD$) of fungi were found in the indoor air of cellular offices $128({\pm}1.0)cfu/m^3$, which was at least three times higher than the concentrations in mixed offices $43({\pm}1.0)cfu/m^3$ (p<0.05). Conclusions: Microbiological contamination in the indoor air of office buildings by work space structure was the highest with the open-plan office layout which includes no high walls or doors separating the occupants.

A Study on Process of Change and Assumption of Archetype of Winsborough Hall at Speer Girls' School in Gwangju (광주구수피아여학교 윈스브로우홀의 변화와 원형추정 연구)

  • Shin, Woong-Ju;Sung, Dae-Chul
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.14 no.4
    • /
    • pp.97-105
    • /
    • 2012
  • Winsborough Hall built by Martin L. Winehart who was the missionary of the Presbyterian Church of America in 1927 was built by Mrs. Winsborough's birthday contribution. Winsborough Hall was clearly divided into the original form built in 1927 and remodelled form by extension. Most of walls were constructed with several kinds of bricks for both sides and opening in the original form and remodelled form. Each room divided by inner wall was kept with original form because it is difficult to remodel it on the characteristics of building. But, it was confirmed through the related literatures that security of opening at some rooms and annexation of rooms through removal of the wall on the 2nd floor which was relatively easy to transform wall compared to the first floor were made. Variability of the wall affected the truss structure of roof and it created rare double truss structure. Architectural value of Winsborough Hall was in its first architectural trial using red brick in Gwangju region since 1920s. It suggested that it was differential architectural trial from Korean-Western mixed building constructed by the missionaries from 1940 to 1910 and buildings made of gray bricks prevailed from 1911 to 1920 and it showed the advancement in the architectural structure and materials.

Improvement for Classification System of Building Use on Neighborhood Living Facility (근린생활시설 용도분류체계 개선방안 연구)

  • Lee, Sung-Ok;Hwang, Eun-Kyoung
    • Journal of architectural history
    • /
    • v.21 no.6
    • /
    • pp.53-62
    • /
    • 2012
  • The purpose of this study is to present improvement for classification system of current neighborhood living facility to correspond rapid social change and various industries after understanding its status and problem. In current Building Standard Law, various kinds of buildings are classified for their structure, purpose of use, and building types. The Neighborhood Living Facility is divided into First Neighborhood Living Facility and Second Neighborhood Living Facility with applying area standards, according to facilities of convenience degree for neighborhood inhabitants. This classification, however, has problem in an arbitrary decision and applying of buildings without any definition or standards to adopt. And, there are some mixed neighborhood public functional facilities and amusement business affecting public morals among the Neighborhood Living Facility, so hazard environmental problems are also existed. According to the improved program, the study presents a prompt adoption of new facilities according to various industry increase, with minimum public discontent over adopted area standards. This study suggests making a clear scope through reclassification of Neighborhood Living Facility within the scope of the law on current Neighborhood Living Facility and an improvement plan of introducing necessary definitions on purpose of facility.

Properties of Light-weight Concrete containing Foamed Glass as a part of Fine Aggregate (발포유리소재를 잔골재로 부분 치환한 경량콘크리트의 특성)

  • Lee, Jin-Woo;Park, Hee-Gon;Bae, Yeoun-Ki;Lee, Jae-Sam;Lee, Keun-Haeng;Moon, Sung-Whan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.113-116
    • /
    • 2008
  • In these days, properties of concrete has been demanded to be high performance because concrete structure was bigger and higher. So studies on high strength concrete and lightweight concrete has been frequently done. But lightweight concrete has been used to limited non-structural elements in th country. Lightweight aggregate mixed with lightweight concrete was only coarse aggregate in case of the structural lightweight concrete. In the country studies on the lightweight concrete was poor and unvaried. Also it is difficult to be practical use of lightweight concrete was that it has been expensive. It was study on the using fine lightweight aggregate with lightweight concrete to crushed by-products and wastes to get to make foamed glass with recycled glass. So it was tested by fine aggregate standard and mixed with.

  • PDF

The Regionally Specific Residential Characteristics of ′Residential-Commercial Mixed Use Buildings′ in Seoul (서울시 주상복합건물의 지역별 주거 특성)

  • 정은진
    • Journal of the Korean Geographical Society
    • /
    • v.38 no.5
    • /
    • pp.741-753
    • /
    • 2003
  • This study begins with paying attention to the agglomeration of 'Residential-Commercial Mixed Use Buildings(hereafter, R-C MU Buildings)', which tend to be a high grade and large sized building cluster at various neighboring areas in Seoul. The purpose of this study is to understand the relationship between emerging new housing type and residential area by analyzing the characteristics of residential neighborhood that is mainly created by R-C MU Buildings. For this purpose, the specialization and the regional characteristics(in connection with the hierarchy in urban spatial structure) of R-C MU Building's residential neighborhood were analyzed. In the end, the specific type of housing reveals the tendency to be differentiated in terms of income, education and occupation related with housing and residential area. And the residential characteristics also seem to be different according to the regions based on the central place hierarchical structure. It means that the social and class factors are important in choosing house, but the characteristics of the neighborhood area play an important role in the selection of resident area. Finally, the location of certain type of housing can influence the selecting process of residence and it can also determine the characteristics of the resident area in turn.