Background: Primary cardiac tumors are extremely rare. The most common type are benign myxomas, and these are almost completely curable with early surgery. Malignant tumors, however, such as sarcomas, are difficult to remove surgically, and their prognosis is known to be poor. In this study, data on patients who had undergone surgical treatment of cardiac tumor in the authors' hospital were collected and analyzed. Material and Method: The subjects included 28 patients who had undergone surgical treatment of cardiac tumor from August 1993 to December 2008. Their medical records were reviewed and retrospectively analyzed. Result: The patients were aged from 20 to 76 years (mean age: $54.2{\pm}15.6$), and 11 were male (39%) and 17 female (61%). Fifteen of them (54%) underwent emergency surgery to improve heart failure symptoms. The most common preoperative symptom was dyspnea (15 cases, 54%). Preoperative echocardiography was performed on all the patients. The average size of the tumor as measured during the operation was $7.0{\pm}6.9cm$ (the average length of the long axis was 2∼40 cm), and the sites of tumor attachment were the interatrial septum (18 cases, 64%), the left atrium (9 cases, 32%), the mitral valve annulus (2 cases, 7%), and the left ventricle (2 cases, 7%). The operation was performed with an incision through both atria in all the patients, and a complete excision was made in 25 cases (89%). According to the biopsy results, there were 4 cases of sarcoma (14%), 1 case of lipoma (4%), and 23 cases of myxoma (82%). The three cases in which the tumors were not completely excised were sarcomas. No operative deaths occurred after the operations. Outpatient follow-up was possible for 24 cases (86%), with a mean follow-up period of $46.8{\pm}42.7$ months. Late death occurred in 3 of the 24 patients; each of these patients had sarcomas. Of these patients, the first had undergone two repeat surgeries, the second had metastatic sites removed, and the last had only chemotherapy. The average recurrence time was $12.7{\pm}10.8$ months, and the average metastasis time was $20.5{\pm}16.8$ months. Conclusion: Most cardiac tumors are benign myxomas. In principle, they should be surgically treated because they can create risks such as embolism, and can be radically treated when surgically removed. In most cases, however, malignant sarcomas are already considerably advanced with severe infiltration into the neighboring tissues at the time of diagnosis. The surgical removal of malignant sarcomas is known to be difficult because of the advanced stage and degree of infiltration. We suggest that excision of the removable portion of the tumor sites to alleviate symptoms such as heart failure can improve quality of life.
Ahn, Hye Mi;Jung, Sun Ok;Kwon, Jung Hyun;Hong, Young Mi
Clinical and Experimental Pediatrics
/
v.53
no.1
/
pp.72-79
/
2010
Purpose: Left ventricular (LV) hypertrophy and impaired diastolic function may occur early in systemic hypertension. Diastolic dysfunction is associated with increased cardiovascular risk. Tissue Doppler imaging (TDI)-derived tissue velocity and strain rate are new parameters for assessing diastolic dysfunction. The aim of this study is to determine whether TDI and strain rate imaging (SRI) would improve the ability to recognize early impaired diastolic and systolic functions compared with conventional echocardiography in hypertensive adolescents. Methods: We included 38 hypertensive patients with systolic blood pressure above 140 mmHg or diastolic blood pressure above 90 mmHg. Ejection fraction and myocardial performance index (MPI) were estimated by conventional echocardiography. Peak systolic myocardial velocity, early diastolic myocardial velocity (Em), and peak late diastolic myocardial velocity (Am) were obtained by using TDI and SRI. Results: In the hypertensive group, interventricular septal thickness was significantly increased on M-mode echocardiography. Em/Am was significantly decreased at the mitral valve annulus. Among hypertensive subjects, the E strain rate at basal, mid, and apex was significantly decreased. Systolic strain was significantly decreased at the septum in the hypertensive group. Conclusion: Strain rate might be a useful new parameter for the quantification of both regional and global LV functions and could be used in long-term follow up in hypertensive patients. Early identification by SRI of subjects at risk for hypertensive and ventricular dysfunction may help to stratify risk and guide therapy. Further studies, including serial assessment of LV structure and function in a larger number of adolescents with hypertension, is necessary.
Hur, Kyong;Kim, Jeong Eun;Kim, Yuria;Kwon, Hae Sik;Yoo, Byung Won;Choi, Jae Young;Sul, Jun Hee
Clinical and Experimental Pediatrics
/
v.50
no.10
/
pp.970-975
/
2007
Purpose : Accurate measurement of defect size is important in transcatheter closure of atrial septal defect (ASD). We performed this study to analyze the difference between the measured ASD size and balloon occlusive diameter (BOD) by transthoracic (TTE) or transesophageal echocardiography (TEE). Methods : We investigated 78 patients who underwent transcatheter closure of ASD. The defect size and the distance between the surrounding structures were measured by TTE and TEE. The BOD was measured by TEE during cardiac catheterization. Clinical characteristics and echocardiographic data were compared and analyzed. Results : The difference between BOD and diameter by TTE was $4.8{\pm}3.6mm$ on short axis view, $5.4{\pm}3.2mm$ on long axis view. The difference between BOD and diameter by TEE was $3.6{\pm}2.2mm$ on short axis view, $4.2{\pm}3.1mm$ on long axis view. The difference between BOD and the diameter of defects on TTE, TEE had statistically significant positive correlations with the age of the patients, distance between the, defect and posterior atrial septal wall, the distance between the defect and the mitral valve leaflet, and the diameter of defects and the length of the atrial septum on TTE (P<0.05). Conclusion : BOD of ASD can be estimated by the diameter on TTE and TEE. BOD is expected to measure larger, depending on the size of defects, the distance from surrounding structures and the location of defects on echocardiography. Our data offers important information on details of transcatheter ASD closure which can be helpful in predicting suitability and judging the procedural appropriateness during the procedure.
Background: Interrupted aortic arch is a rare congenital heart anomaly which still shows high surgical mortality. In this study, we investigated the causes of and the risk factors for mortality to improve the surgical outcomes for this difficult disease entity. Material and Method: From 1984 to 2004, 42 patients diagnosed as IAA were reviewed retrospectively. Age, body weight at operation, preoperative diagnosis, preoperative PGE1 requirement, type of interrupted aortic arch, degree of left ventricular outflow stenosis, CPB time, and ACC time were the possible risk factors for mortality. Result: There were .14 hospital deaths. Preoperative use of PGE1, need for circulartory assist and aortic cross clamp time proved to be positive risk factors for mortality on univariate analysis. Preoperative left ventricular outflow stenosis was considered a risk factor for mortality but it did not show statistical significance (p-value=0.61). Causes of death included hypoxia due to pulmonary banding, left ventricular outtract stenosis, infection, mitral valve regurgitation, long cardiopulmonary bypass time and failure of coronary transfer failure in TGA patients. Conclusion: In this study, we demonstrated that surgical mortality is still high due to the risk factors including preoperative status and long operative time. However preoperative subaortic dimension was not related statistically to operative death statistically. Adequate preoperative management and short operation time are mandatory for better survival outcome.
Background : Coronary artery bypass graft(CABG) in patients with advanced left ventricular dysfunction has often been regarded as having high mortality rate, despite the great improvement in operative result of CABG. With recent advances in surgical technique and myocardial protection, surgical revascularization improved the symptom and long-term survival of these high risk patients more than the medical conservative treatment. Material and Methold : Clinical data of 31(4.1%) patients with preoperative ejection fraction less than 30% among 864 CABGs performed between January 1995 and March 1999 were retrospectively analyzed and pre- and postoperative changes of the ejection fraction on echocardiography were analyzed. There were 26 men and 5 women. The mean age was 60.7 years(range 41 to 72 years). History of myocardial infarction(30 cases, 98%) was the most common preoperative risk factor. There were seven irreversible myocardial infarction on thallium scan. Most patients had triple vessel diseases(26 cases, 84%) and first degree of Rentrop classification(16 cases, 52%) on coronary angiography. The mean number of distal anastomosis during CABG was per patient was 4.9${\pm}$0.8 sites in each patient. In addition to long saphenous veins, the internal mammary artery was used in 20 patients. Total bypass time was 244.7${\pm}$3.7 minutes(range, 117 to 567 minutes), and mean aortic cross-clamp time was 77.9 ${\pm}$ 1.6 minutes(range, 30 to 178 minutes). There were five other reparative procedures such as two left ventricular aneurysrmectomy, two mitral repair, and one aortic valve replacement. There were twelve postoperative complications such as three cardiac arrhythmia, two bleeding(re-operation), one delayed sternal closure, eleven usage of intra-aortic balloon counterpulsation for low cardiac output. Two patients died, postoperative mortality was 6.5% . Twenty-nine patients were relieved of chest pain and left ventricular ejection fraction after operation was significantly higher(38.5${\pm}$11.6%, p 0.001) as compared with preoperative left ventricular ejection fraction(25.3${\pm}$2.3%). The follow up period of out patient was 25. 3 months. Conclusion: In patients with coronary artery disease and advanced left ventricular dysfunction, coronary artery bypass grafting can be performed relatively safely with improvement in left ventricular function, but it will be necessary to study long term results.
Seong, Ji Hye;Lee, Dong Hun;Kim, Eun Hye;Jung, Woo Young
The Korean Journal of Nuclear Medicine Technology
/
v.23
no.1
/
pp.75-79
/
2019
Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at $0.25{\pm}1.00$, $0.24{\pm}0.96$ and $0.25{\pm}0.82cm$ respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.
Background: The improvements in endoscopic equipment and surgical robots has encouraged the performance of minimally invasive cardiac operations. Yet only a few Korean studies have compared this procedure with the sternotomy approach. Material and Method: Between December 2005 and July 2007, 48 patients (group A) underwent minimally invasive cardiac surgery with AESOP through a small right thoracotomy. During the same period, 50 patients (group B) underwent conventional surgery. We compared the operative time, the operative results, the post-operative pain and the recovery of both groups. Result: There was no hospital mortality and there were no significant differences in the incidence of operative complications between the two groups. The operative $(292.7{\pm}61.7\;and\;264.0{\pm}47.9min$, respectively; p=0.01) and CPB times ($128.4{\pm}37.6\;and\;101.7{\pm}32.5min$, respectively; <0.01) were longer for group A, whereas there was no difference between the aortic cross clamp times ($82.1{\pm}35.0\;and\;87.8{\pm}113.5min$, respectively; p=0.74) and ventilator times ($18.0{\pm}18.4\;and\;19.7{\pm}9.7$ hr, respectively; p=0.57) between the groups. The stay on the ICU $(53.2{\pm}40.2\;and\;72.8{\pm}42.1hr$, respectively; p=0.02) and the hospitalization time ($9.7{\pm}7.2\;and\;14.8{\pm}11.9days$, respectively; p=0.01) were shorter for group A. The Patients in group B had more transfusions, but the difference was not significant. For the overall operative intervals, which ranged from one to four weeks, the pair score was significantly lower for the patients of group A than for the patients of group B. In terms of the postoperative activities, which were measured by the Duke Activity Scale questionnaire, the functional status score was clearly higher for group A compared to group B. The analysis showed no difference in the severity of either post-repair of mitral ($0.7{\pm}1.0\;and\;0.9{\pm}0.9$, respectively; p=0.60) and tricuspid regurgitation ($1.0{\pm}0.9\;and\;1.1{\pm}1.0$, respectively; p=0.89). In both groups, there were no valve related complications, except for one patient with paravalvular leakage in each group. Conclusion: These results show that compared with the median sternotomy patients, the patients who underwent minimally invasive surgery enjoyed significant postoperative advantages such as less pain, a more rapid return to full activity, improved cosmetics and a reduced hospital stay. The minimally invasive surgery can be done with similar clinical safety compared to the conventional surgery that's done through a median sternotomy.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.