• Title/Summary/Keyword: Mishima

Search Result 94, Processing Time 0.022 seconds

Studies on Seed Germination Characters and Germination Inhibitors of Bupleurum falcatum L. (자호(紫胡)의 발아특성(發芽特性)과 발아억제물질(發芽抑制物質)에 관(關)한 연구(硏究))

  • Lee, Sang-Hyun;Lee, Sang-Chul
    • Korean Journal of Medicinal Crop Science
    • /
    • v.5 no.4
    • /
    • pp.276-283
    • /
    • 1997
  • This experiment was conducted to investigate the optimum temperature and the effects of sulfuric acid, flowing water and $GA_3$ on the germination of Bupleurum falcatum. At the same time, the effect of germination-related compounds in Bupleurum falcatum seed was tested. Among the tested temperatures $(15,\;20,\;25\;and\;30^{\circ}C)$ the highest germination rate was obtained at $15^{\circ}C$. The optimum soaking time of sulfuric acid was 5 minutes at the concentration of both 0.1 and 1.0%. At the same time, the germination rate was highest when Bupleurum falcatum seed was washed for 2 days in the flowing water before germination test. The effect of $GA_3$ on the germination was highest at 100 ppm out of 10, 50 and 100 ppm. Regardless of treatments, the germination rate of Jeongseon species was higher than that of Mishima species. SEM photographs revealed that most of germination-inhibiting substances in the seed coat were washed away by rinsing in the flowing water for 2 days thus the seed coat became more smooth. The 4, 000 ppm alcohol extract of Bupleurum falcatum seeds inhibited the germination of lettuce seeds as much as 41.7% in Jeongseon species and 58.3% in Mishima species. The higher extract concentration from seed of Bupleurum falcatum, the lower the germination of lettuce seeds was obtained. Out of phenolic acids, the contents of orchinol, pyrogallol, and p-hydroxybenzoic acid were highest in both varieties. Compared with Mishima species, Jeongseon species showed much higher content of salicylic and vanillic acid.

  • PDF

Vertical Upward Air-Water Two-Phase Flow Regime Identification (수직상향류 공기-물 이상유동영역 판별)

  • Lee, Ba-Ro;Jang, Young-Jun;Ko, Min-Seok;Lee, Bo-An;Lee, Yeon-Gun;Kim, Sin
    • Journal of Energy Engineering
    • /
    • v.22 no.4
    • /
    • pp.362-369
    • /
    • 2013
  • Two-phase flow is frequently observed in many industries such as nuclear power plants and oil transportation. Two-phase flow regime depends on the flow rates, the fluid properties and the structure of flow channels. Since the identification of the flow regime is of great importance in the system design and the safety analysis, a number of theoretical and experimental investigations have been performed. This paper presents a basic research on the characteristics of each flow regime and transition boundary in the two-phase flows. The flow regime of the upward air-water flow in the vertical tube, 30 mm in the inner diameter, is distinguished by using the high-speed camera and the Wire-mesh sensor(WMS). The identified experimental data are compared with the flow regime maps proposed by Taitel et al, Mishima and Ishii. Even though there is slight difference in the transition boundary, the experimental data show general agreement with these flow regime maps.

Experimental Study and Correlation Development of Critical Heat Flux under Low Pressure and Low Flow Condition

  • Kim, Hong-Chae;Baek, Won-Pil;Kim, Han-Kon;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.356-361
    • /
    • 1997
  • To investigate parametric effect on CHF and to get CHF data, experimental study has been performed with vertical round tubes under the condition of low pressure and low flow (LPLF). Test sections are made of Inconel-625 tube and have the geometry of 8 and 10 mm in diameter, and 0.5 and 1.0 m in heated length. All experiments have been conducted at the pressure of under 9 bar, the mass flux of under 250 kg/$m^2$ and the inlet subcooling of 350 and 450 kJ/kg, for stable upward flow with water as a coolant. Flow regime analysis has been performed for obtained CHF data with Mishima's flow regime map, which reveals that most of the CHF occur in the annular-mist flow regime. General parametric trends of the collected CHF data are consistent with those of previous studies. However, for the pressure effect on CHF, two different are observed; For relatively high mass flux, CHF increases with pressure and far lower mass flux, CHF decrease with pressure. Using modern data regression tool, ACE algorithm, two new CHF correlations for LPLF condition are developed based on local condition and inlet condition, respectively. The developed CHF correlations show better prediction accuracy compared with existing CHF prediction methods.

  • PDF

Design of Real-Time Monitoring System for Recycling Agricultural Resourcing Based on USN

  • Ji, Geun-Seok;Min, Byoung-Won;Oh, Yong-Sun;Mishima, Nobuo
    • International Journal of Contents
    • /
    • v.9 no.4
    • /
    • pp.22-29
    • /
    • 2013
  • In this paper, we propose a integrated real-time monitoring system for recycling agriculture resourcing based on USN. We design and implement the monitoring system so that we can integrate the quality control of farmyard and liquid manures, barn environment monitoring, and positioning information control into a total management system performing recycling of excrement and manure. Selection of sensors and sensor-node construction and requirements, structure of wire/wireless communication networks, and design of monitoring program are also presented. As a result of operating our system, we can get over various drawbacks of conventional separated system and promote the proper circulation of excrement up to the farmyard. We confirm that these advanced effects arise from the effective management of the total system integrating quality control of farmyard/liquid manure, barn/farmhouse information, and vehicle moving monitoring information etc. Moreover, this monitoring system is able to exchange real-time information throughout communication networks so that we can construct a convenient information environment for agricultural community by converging IT technology with farm and stockbreeding industries. Finally we present some results of processing using our monitoring system. Sensing data and their graphs are processed in real-time, positioning information on the v-world map offers various moving paths of vehicles, and statistical analysis shows all the procedure from excrement occurrence to recycling and resourcing.

Immune activation and radioprotection by Echinacea purpurea (American herb)

  • Mishima, Satoshi;Gu, Yeun-Hwa;Saito, Kiyoto;Yamashita, Takenori;Maruyama, Hiroe;Inoue, Makoto;Ahn, Kyoo-Seok
    • Advances in Traditional Medicine
    • /
    • v.4 no.3
    • /
    • pp.163-170
    • /
    • 2004
  • The effect of immune activation by Echinacea purpurea was investigated by measuring total immunoglobulin (Ig) G, IgM. and the radioprotective effect of immune activation by Echinacea purpurea was investigated by measuring T lymphocyte subsets in the peripheral blood of mice following whole body irradiation. Echinacea purpurea activated macrophages to stimulate $IFN-{\gamma}$ production in association with the secondary activation of T lymphocytes, resulting in a decrease in IgG and IgM production. Cytokines released from macrophages in mouse peripheral blood after Echinacea purpurea administration activated helper T cells to proliferate. In addition, activated macrophages in association with the secondary T lymphocyte activation increased $IFN-{\gamma}$ production and stimulated proliferation of cytotoxic T cells and suppressor T cells, indicating the activation of cell-mediated immune responses.

A High Frequency-Link Bidirectional DC-DC Converter for Super Capacitor-Based Automotive Auxiliary Electric Power Systems

  • Mishima, Tomokazu;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.27-33
    • /
    • 2010
  • This paper presents a bidirectional DC-DC converter suitable for low-voltage super capacitor-based electric energy storage systems. The DC-DC converter presented here consists of a full-bridge circuit and a current-fed push-pull circuit with a high frequency (HF) transformer-link. In order to reduce the device-conduction losses due to the large current of the super capacitor as well as unnecessary ringing, synchronous rectification is employed in the super capacitor-charging mode. A wide range of voltage regulation between the battery and the super capacitor can be realized by employing a Phase-Shifting (PS) Pulse Width Modulation (PWM) scheme in the full-bridge circuit for the super capacitor charging mode as well as the overlapping PWM scheme of the gate signals to the active power devices in the push-pull circuit for the super capacitor discharging mode. Essential performance of the bidirectional DC-DC converter is demonstrated with simulation and experiment results, and the practical effectiveness of the DC-DC converter is discussed.

Computation of Change Time for Migrate Dynamic Workflow Changes

  • Shingo Yamaguchi;Akira Mishima;Ge, Qi-Wei;Minoru Tanaka
    • Proceedings of the IEEK Conference
    • /
    • 2002.07b
    • /
    • pp.955-958
    • /
    • 2002
  • A workflow is a flow of work supported by computers. An instance of a workflow is called case. Companies need to constantly refine their current workflows in order to meet various requirements. The change of current workflows is called dynamic change of the workflow. Since Ellis et al. proposed three change types, Flush, Abort, and Synthetic Cut-Over in 1995, various change types have been proposed. A promising change type is Migrate proposed by Sadiq et al., because Migrate changes workflow definitions immediately and makes the redo of cases minimum. However, the formal modeling and time-dependent analysis of Migrate has not been done. This paper proposes a method of computing change time of Migrate dynamic changes for time-dependent analysis. Change time is a measure for evaluating dynamic changes. We first show a Petri-nets-based model of Migrate dynamic changes. Then we present a method of computing change time based on the net model. Finally, we apply the method to 270 examples, and show experimental results, and comparison with Ellis et al..'s three change types.

  • PDF

Counter-Current Gas-Liquid Two-Phase Flow Regimes in Narrow Rectangular Channels (협소 사각 유로에서 대향류 기/액 2상 유동양식)

  • Sohn, B.H.;Kim, B.J.;Jeong, S.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.136-141
    • /
    • 2000
  • A study of counter-current two-phase flow in narrow rectangular channels has been performed. Two-phase flow regimes were experimentally studied in 760 mm long and 100 mm wide test sections with 2.0 and 3.0mm gaps. The resulting data have been compared to previous transition models. For the transition from bubbly to slug flow the superficial velocity of gas increased as the gap width increased. The comparison of experimental data to the transition model developed by Taitel and Barnea showed relatively good agreement for the bubbly-to-slug transition in the case of 2mm gap width. For the criteria of Mishima and Ishii to be applicable to the slug-to-churn transition the distribution parameter should be well defined for narrow channels. Even though the gap width of narrow channels increased the superficial gas velocity did not change for the transition form chum to annular flow regime. For the chum-to-annular transition the model of Taitel and Barnea showed discrepancies with experimental data, especially in the channel with larger gap.

  • PDF

Experimental study on two-phase flow behavior inside a vertical tube evaporator under flashing phenomenon (후래시 현상을 수반하는 수직증발관내에서의 2상유동에 관한 실험적 연구)

  • 이상용;송시홍;이상호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.4
    • /
    • pp.833-846
    • /
    • 1988
  • Two-phase flow heat transfer phenomena with flash evaporation inside a vertical tube were studied experimentally. Void fractions were measured using electrical probes, and the flow patterns were identified from the output voltage signal itself. The flow pattern as well as the beat transfer rates were changing along the axial distance from the tube inlet with the system pressure. As the pressure inside the tube decreases with fixed inlet temperature, the overall heat transfer coefficient through the tube wall and the boiling heat transfer coefficient inside the tube increase whereas the condensation heat transfer coefficient outside the tube decreases. The boiling heat transfer coefficient inside the tube measured by the experiments appeared to be somewhat larger than the value obtained from the Chen's correlation. Also, the flow patterns identified from present experiments are at the larger quality region of the low pattern map based on the transition criteria of Mishima and Ishii. This may be due to the non-equilibrium flashing phenomenon occurred at the nozzle exit and the tube inlet ; this also implies that the flow pattern of the two-phase flow depends strongly on the inlet conditions.

Open-slip coupled model for simulating three-dimensional bond behavior of reinforcing bars in concrete

  • Shang, Feng;An, Xuhui;Kawai, Seji;Mishima, Tetsuya
    • Computers and Concrete
    • /
    • v.7 no.5
    • /
    • pp.403-419
    • /
    • 2010
  • The bond mechanism for reinforcing bars in concrete is equivalent to the normal contact and friction between the inclined ribs and the surrounding concrete. Based on the contact density model for the computation of shear transfer across cracks, an open-slip coupled model was developed for simulating three-dimensional bond behavior for reinforcing bars in concrete. A parameter study was performed and verified by simulating pull-out experiments of extremely different boundary conditions: short bar embedment with a huge concrete cover, extremely long bar embedment with a huge concrete cover, embedded aluminum bar and short bar embedded length with an insufficient concrete cover. The bar strain effect and splitting of the concrete cover on a local bond can be explained by finite element (FE) analysis. The analysis shows that the strain effect results from a large local slip and the splitting effect of a large opening of the interface. Finally, the sensitivity of rebar geometry was also checked by FE analysis and implies that the open-slip coupled model can be extended to the case of plain bar.