• 제목/요약/키워드: Mirror System

검색결과 834건 처리시간 0.029초

머시닝센터의 체적오차 보상을 통한 구면 가공형상 측정 OMM시스템 연구 (A Study of an OMM System for Machined Spherical form Using the Volumetric Error Calibration of Machining Center)

  • 김성청;김옥현;이응석;오창진;이찬호
    • 한국정밀공학회지
    • /
    • 제18권7호
    • /
    • pp.98-105
    • /
    • 2001
  • The machining accuracy is affected by geometric, volumetric errors of the machine tools. To improve the product quality, we need to enhance the machining accuracy of the machine tools. To this point of view, measurement and inspection of finished part as error analysis of machine tools ahas been studied for last several decades. This paper suggests the enhancement method of machining accuracy for precision machining of high quality metal reflection mirror or optics lens, etc. In this paper, we study 1) the compensation of linear pitch error with NC controller compensation function using laser interferometer measurement, 2) the method for enhancing the accuracy of NC milling machining by modeling and compensation of volumetric error, 3) the spherical surface manufacturing by modeling and compensation of volumetric error of the machine tool, 4) the system development of OMM without detaching work piece from a bed of machine tool after working, 5) the generation of the finished part profile by OMM. Furthermore, the output of OMM is compared with that of CMM, and verified the feasibility of the measurement system.

  • PDF

과학교육 연구자료의 정보 전산화 체제(II) -서울대학교 대학원 과학교육과의 학위 눈문 분석- (Data base system for the information on science education research and development: (II) Analysis of master's theses and doctoral dissertations from the Department of Science Education, Seoul National University)

  • 이원식;박승재;김영수
    • 한국과학교육학회지
    • /
    • 제11권2호
    • /
    • pp.143-159
    • /
    • 1991
  • The purpose of this study is to develop a data base system for the infromation on research and development of science education. As a part of this development, an analysis of master's theses and doctoral dissertations from the Department of Science Education, Seoul National University was done, and using authors' classification system for the research and development materials of science education, those theses were classified. From the analysis and classification, the following conclusion was drawn: 1) The Department of Science Education, Seoul National University had produced 468 masters of education for about 30 years. Among them, only 107 theses were on the science education and the other 361 theses on the pure science. This means that department has not taken root as a department of science education. If it does not carry out its own purpose of establishment, it will not be able to justify its existence any longer 2) As compared to the increased number of students applying for the doctoral program, the number of faculty is very few in the field of science education. Without more supplement of the faculty member majored science education, there will be increased conflict and disorder among faculty and students. 3) The proportion of the theses on science education to those on science vanes greatly by the major of the department. This is the mirror of the faculty attitude to and recognition of science education and the faculty composition. 4) The classification of master theses and doctoral dissertations on science education showed that most of them focused on the secondary school science education and were survey studies. But recently it is noticeable that the theme of the study became diversified and has kept in step with the international research trends.

  • PDF

공초점 원리와 광섬유 광원 변조를 이용한 무한보정 현미경 자동초점 (Autofocus of Infinity-Corrected Optical Microscopes by Confocal Principle and Fiber Source Modulation Technique)

  • 박정재;김승우;이호재
    • 한국광학회지
    • /
    • 제15권6호
    • /
    • pp.583-590
    • /
    • 2004
  • 비전을 이용한 광학식 검사공정이나 그 밖의 광학 현미경을 이용한 측정에 있어서 초점조절은 곧바로 측정 정밀도에 영향을 주는 중요한 요소이다. 본 논문에서는 핀홀 대신 광섬유를 사용하는 공초점 현미경 구조와 하나의 광섬유가 광원과 검출기의 역할을 동시에 수행하는 상반구성(reciprocal scheme)을 적용함으로써 간결하게 시스템을 구성하면서 광축 정렬을 용이하게 하였으며, 압전소자(PZT)를 이용한 광섬유 광원의 광축 방향 변조를 통해 방향 정보가 실린 초점오차 신호를 획득함으로써 빠른 초점조절을 구현하였다. 대물렌즈 변조방식과 달리 광원 변조방식은 현미경 시스템에 미치는 물리적 영향을 줄일 수 있으며, 기존의 장치에 탑재가 비교적 용이하다는 장점을 갖는다. 본 논문에서는 변조 진폭과 시편의 반사도 및 기울기 변화에 따른 초점오차 신호의 변화를 측정하였으며, 거울 시편에 대한 초점조절을 통해 본 시스템의 성능을 평가해 보았다. 또한 종방향 특성곡선의 반치폭 비교실험을 통해 광원 변조는 광축 방향 분해능에 영향을 주지 않음을 확인하였다.

전자포탈영상장치의 제작과 방사선치료장치의 QA 적용에 관한 연구 (A Study on QA for Radiation Therapy Machine by Using Implemented Electronic Portal Imaging Device)

  • 이동훈
    • 전자공학회논문지SC
    • /
    • 제43권6호
    • /
    • pp.68-75
    • /
    • 2006
  • 고 에너지 방사선을 이용하여 종양을 치료하는 과정 중 발생되는 오차를 확인하여 보다 정교한 치료를 수행함으로써 방사선치료 효율을 향상시킬 수 있다. 본 논문에서는 지금까지 주로 사용되어진 필름을 이용한 아날로그 방식대신 실 시간적으로 영상을 얻을 수 있는 디지털 방식의 비디오 기반 전자 포탈 영상 장치를 개발하였다. 시스템은 $Gd_2O_2S$ 인광판, $45^{\circ}$반사경 및 후레임 그래버를 이용 비디오 기반 전자 포탈 영상 장치를 제작하였으며 이를 방사선치료기의 QA장치로 활용하고자 하였다. 이 장치를 이용 치료기 자체의 정확도를 검증하기 위해 방사선 조사면 검증을 수행하였다. 방사선 조사면이 콜리메이터 회전오차에 의해 약 $0.6^{\circ}$틀어짐을 전자 포탈 영상 장치를 통해 획득된 영상의 윤곽선을 검출한 후 알 수 있어서 치료 위치 설정 중 발생할 수 있는 오차 확인을 위한 방사선 치료장치의 Q.A도구로 사용할 수 있었다.

Electrochromic Device for the Reflective Type Display Using Reversible Electrodeposition System

  • Kim, Tae-Youb;Cho, Seong M.;Ah, Chil Seong;Suh, Kyung-Soo;Ryu, Hojun;Chu, Hye Yong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.232.1-232.1
    • /
    • 2014
  • The green displays are the human friendly displays, the nature friendly displays, and the economical displays. Electrochromic displays are low cost and environmental devices because they do have more choice of colours and use much less power. The elements of the electrochromic devices consist of at least two conductors, an electrochromic material and an electrolyte. The optical properties were obtained using the optical contrast between the transparency of the substrate and the coloured state of the electrochromic materials. These devices can be fully flexible and printable. Due to the characteristics of the high coloration efficiency and memory effects, the electrochromic devices have been used in various applications such as information displays, smart windows, light shutters and electronic papers. Among these technical fields switchable mirrors have been received much attention in the applicative point of view of various electronic devices production. We have developed a novel silver (Ag) deposition-based electrochromic device for the reversible electrodeposition (RED) system. The electrochromic device can switch between transparent states and mirror states in response to a change in the applied voltage. The dynamic range of transmittance percent (%) for the fabricated device is about 90% at 550 nm wavelength. Also, we successfully fabricated the large area RED display system using the parted electrochromic cells of the honey comb structure.

  • PDF

층 밀리 간섭계를 이용한 고체침지렌즈의 광학적 성능 평가 (Optical Performance Evaluation of SIL Assembly with Lateral Shearing Interferometer)

  • 이진의;김완진;최현;김태섭;윤용중;박노철;박영필
    • 정보저장시스템학회논문집
    • /
    • 제2권4호
    • /
    • pp.224-229
    • /
    • 2006
  • There has been studied flow to minimize the spot size to increase data capacity. Optical data storage devices are being developed near practical limits with wavelength and NA of 405nm and 0.85. There has been studied many types of next generation storage devices such as blu-ray multilayer system, probe based data storage and holographic data storage. Among these data storage devices, solid immersion lens(SIL) based near field recording (NFR) has been widely studied. In this system, SIL is the key component that focuses the laser beam with a very small size which enables ultra high data capacity. Therefore, optical performance evaluation system is required for SIL assembly. In this dissertation, a simple and accurate SIL assembly measurement method is proposed with wedge plate lateral shearing interferometer(LSI). Wedge plate LSI is cheaper than commercialized interferometer, robust to the vibration and the moving distance for phase shifting is large that is order of micrometer. We designed the thickness, wedge angle, material, surface quality and wavelength of wedge plate as 1mm, 0.02degree, fused silica, lamda/10(10-5) and 405nm, respectively. Also, we confirmed simulation and experimental results with quantitative analysis. This simple wedge plate LSI can be applied to different types of SIL such as solid immersion mirror(SIM), hemispherical, super-hemispherical and elliptical SIL.

  • PDF

직경 300 mm 광집속장치의 광학정렬 (Assembly of diameter 300 mm optical beam director)

  • 양호순;이윤우;김정주;엄해동;이수상;김연수;김현숙
    • 한국광학회지
    • /
    • 제16권6호
    • /
    • pp.521-526
    • /
    • 2005
  • 우리는 국내에서 처음으로 직경 300 mm인 광집속장치를 정렬 및 조립하였다. 이 장치는 주경, 부경 그리고 5개의 연결 거울로 구성된다. 이중에서 가장 중요한 부품인 주경은 각 구조물들과의 조립때마다 발생할 수 있는 변형을 정밀 측정하였다. 또한 사용되는 거울의 개수가 많기 때문에 광학정렬에는 체계적인 정렬 알고리즘을 도입하였다. 최종 조립결과 파면수차는 1.9 wave rms(wave =633 nm)로 예상치의 7배정도 큰 값이었다. 이것의 주원인은 조립 과정에서 발생한 연결 거울들의 변형인 것으로 확인되었다. 본 광집속장치를 정렬하면서 발생했던 문제점들에 대한 고찰은 향후 대형광학계를 만들 때 유용하게 사용될 수 있다.

AUTO-GUIDING SYSTEM FOR CQUEAN (CAMERA FOR QUASARS IN EARLY UNIVERSE)

  • Kim, Eun-Bin;Park, Won-Kee;Jeong, Hyeon-Ju;Kim, Jin-Young;Kuehne, John;Kim, Dong-Han;Kim, Han-Geun;Odoms, Peter S.;Chang, Seung-Hyuk;Im, Myung-Shin;Pak, Soo-Jong
    • 천문학회지
    • /
    • 제44권4호
    • /
    • pp.115-123
    • /
    • 2011
  • To perform imaging observations of optically red objects such as high redshift quasars and brown dwarfs, the Center for the Exploration of the Origin of the Universe (CEOU) recently developed an optical CCD camera, Camera for QUasars in EArly uNiverse (CQUEAN), which is sensitive at 0.7-1.1 ${\mu}m$. To enable observations with long exposures, we develop an auto-guiding system for CQUEAN. This system consists of an off-axis mirror, a baffle, a CCD camera, a motor and a differential decelerator. To increase the number of available guiding stars, we design a rotating mechanism for the off-axis guiding camera. The guiding field can be scanned along the 10 arcmin ring offset from the optical axis of the telescope. Combined with the auto-guiding software of the McDonald Observatory, we confirm that a stable image can be obtained with an exposure time as long as 1200 seconds.

Development of Respiration Sensors Using Plastic Optical Fiber for Respiratory Monitoring Inside MRI System

  • Yoo, Wook-Jae;Jang, Kyoung-Won;Seo, Jeong-Ki;Heo, Ji-Yeon;Moon, Jin-Soo;Park, Jang-Yeon;Lee, Bong-Soo
    • Journal of the Optical Society of Korea
    • /
    • 제14권3호
    • /
    • pp.235-239
    • /
    • 2010
  • In this study, we have fabricated two types of non-invasive fiber-optic respiration sensors that can measure respiratory signals during magnetic resonance (MR) image acquisition. One is a nasal-cavity attached sensor that can measure the temperature variation of air-flow using a thermochromic pigment. The other is an abdomen attached sensor that can measure the abdominal circumference change using a sensing part composed of polymethyl-methacrylate (PMMA) tubes, a mirror and a spring. We have measured modulated light guided to detectors in the MRI control room via optical fibers due to the respiratory movements of the patient in the MR room, and the respiratory signals of the fiber-optic respiration sensors are compared with those of the BIOPAC$^{(R)}$ system. We have verified that respiratory signals can be obtained without deteriorating the MR image. It is anticipated that the proposed fiber-optic respiration sensors would be highly suitable for respiratory monitoring during surgical procedures performed inside an MRI system.

거창 우주물체 레이저 추적 시스템의 추적마운트 지향 정밀도 분석 (Pointing Accuracy Analysis of Space Object Laser Tracking System at Geochang Observatory)

  • 성기평;임형철;박종욱;최만수;유성열;박은서;류재철
    • 한국항공우주학회지
    • /
    • 제49권11호
    • /
    • pp.953-960
    • /
    • 2021
  • 거창 우주물체 레이저 추적 시스템은 인공위성 레이저 추적, 적응광학, 우주쓰레기 레이저 추적 등 과학 연구 및 국가적 미션을 수행하기 위해 100cm 크기의 광학 망원경을 가지고 있으며, 빠르고 정밀한 구동을 위하여 경위대식 방식의 추적마운트를 개발하여 테스트 관측 중에 있다. 최근 레이저 추적 시스템의 자동 관측 및 응용 연구 분야에서 추적 대상을 정밀하게 추적할 수 있는 능력은 시스템 성능을 판단할 수 있는 중요한 지표 중 하나이다. 그러기 위해서는 정밀 추적을 저해하는 요인을 파악하고 보정하기 위한 지향 보정 모델이 요구된다. 따라서 본 논문에서는 추적마운트 제작, 조립 및 설치 과정에서 발생 할 수 있는 정적 지향 오차 발생 원인들을 분석하였으며, 거창 우주물체 레이저 시스템의 추적마운트에 적용된 지향 보정 모델 및 최소자승법을 통해 추적마운트 파라미터를 추정하고, 지향 정밀도 분석 결과를 제시하였다.