• Title/Summary/Keyword: Mirror 2.0

Search Result 272, Processing Time 0.029 seconds

Flexible Optical Waveguide Film with Embedded Mirrors for Short-distance Optical Interconnection (근거리 광연결용 미러 내장형 연성 광도파로 필름)

  • An, Jong Bae;Lee, Woo-Jin;Hwang, Sung Hwan;Kim, Gye Won;Kim, Myoung Jin;Jung, Eun Joo;Rho, Byung Sup
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • In the paper, we fabricated a Ni master with $45^{\circ}$-mirror structures for flexible waveguide fabrication. The flexible waveguide films with embedded $45^{\circ}$-angled mirrors at the waveguide ends were successfully fabricated using a UV-imprint process. Next, in order to enhance the reflectivity of the mirrors, Ni(3 nm)-Au(200 nm) bilayers were evaporated on the $45^{\circ}$-angled facets through a locally opened thin mask using an electron beam evaporator. We measured propagation loss, bending loss, mirror loss and bending reliability of the fabricated waveguide.

Analysis of Gain and Frequency in a DFB laser with Cleaved Facets (결정 벽개면을 갖는 DFB 레이저의 이득과 주파수 분석)

  • Lee, Chang-Seok;Kwon, Kee-Young;Ki, Jang-Geun;Cho, Hyun-Mook
    • Journal of Software Assessment and Valuation
    • /
    • v.16 no.2
    • /
    • pp.117-125
    • /
    • 2020
  • In this paper, when both the refractive index grating and the gain grating exist in a 1.55um DFB laser with two cleaved mirror facets, when the phase of ρl is fixed to 0 and the phase of ρr is changed to -π/2, π, π/2, 0, the change in frequency and oscillation gain was theoretically analyzed. In the case of δL<0, the oscillation gain required for lasing is the lowest and the most stable frequency operation is obtained in the case of (ρl phase=0, ρr phase=0) and κL=10, when κL is varied from 0.1 to 10. In the case of δL>0, when (ρl phase=0, ρr phase=π) and κL=10, the oscillation gain required for lasing is the lowest and the difference between the oscillation gains of the higher-order modes is large so that the most stable frequency operation is obtained.

유도결합 $Cl_2/CHF_3, Cl_2/CH_4, Cl_2/Ar $플라즈마를 이용한 InGaN 건식 식각 반응 기구 연구

  • 이도행;김현수;염근영;이재원;김태일
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.249-249
    • /
    • 1999
  • GaN과 같은 III-nitride 반도체 관한 식각 기술의 연구는 blue-emitting laser diode(LD)를 위한 경면(mirror facet)의 형성뿐만아니라 새로운 display 용도의 light emitting diodes (LED), 고온에서 작동되는 광전소자 제조 등에도 그 중요성이 증대되고 있다. 최근에는 III-nitride 물질의 높은 식각속도와 미려하고 수직한 식각형상을 이루기 위하여 ECR(Electron Cyclotron Resonance)이나 ICP(Inductively Coupled Plasma)와 같은 고밀도 플라즈마 식각과 CAIBE(Chemically assisted ion beam etching)를 이용한 연구가 진행되고 있다. 현재 제조되어 지고 있는 LED 및 LD와 같은 광소자의 구조의 대부분은 p-GaN/AlGaN/InGaN(Q.W)/AlGaN/n-GaN 와 같은 여러 층의 형태로 이루어져 있다. 이중 InGaN는 광소자나 전자소자의 특성에 영향을 주는 가장 중요한 부분으로써 현재까지 보고된 식각연구는 undoped GaN에 대부분 집중되고 있고 이에 비해 소자 특성에 핵심을 이루는 InGaN의 식각특성에 관한 연구는 미흡한 상황이다. 본 연구에서는 고밀도 플라즈마원인 ICP 장비를 이용하여 InGaN를 식각하였고, 식각에는 Cl2/CH4, Cl2/Ar 플라즈마를 사용하였다. InGaN의 식각특성에 영향을 미치는 플라즈마의 특성을 관찰하기 위하여 quadrupole mass spectrometry(QMS)와 optical emission spectroscopy(PES)를 사용하였다. 기판 온도는 5$0^{\circ}C$, 공정 압력은 5,Torr에서 30mTorr로 변화시켰고 inductive power는 200~800watt, bias voltage는 0~-200voltage로 변화시켰으며 식각마스크로는 SiO2를 patterning 하여 사용하였다. n-GaN, p-GaN 층 이외에 광소자 제조시 필수적인 InGaN 층을 100% Cl2로 식각한 경우에 InGaN의 식각속도가 GaN에 비해 매우 낮은 식각속도를 보였다. Cl2 gas에 소량의 CH4나 Ar gas를 첨가하는 경우와 공정압력을 감소시키는 경우 식각속도는 증가하였고, Cl2/10%Ar 플라즈마에서 공정 압력을 감소시키는 경우 식각속도는 증가하였고, Cl2/10%CHF3 와 Cl2/10%Ar 플라즈마에서 공정압력을 15mTorr로 감소시키는 경우 InGaN과 GaNrks의 선택적인 식각이 가능하였다. InGaN의 식각속도는 Cl2/Ar 플라즈마의 이온에 의한 Cl2/CHF3(CH4) 플라즈마에서의 CHx radical 형성에 의하여 증가하는 것으로 사료되어 진다.

  • PDF

Numerical and Experimental Investigation of the Heating Process of Glass Thermal Slumping

  • Zhao, Dachun;Liu, Peng;He, Lingping;Chen, Bo
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.2
    • /
    • pp.314-320
    • /
    • 2016
  • The glass thermal forming process provides a high volume, low cost approach to producing aspherical reflectors for x-ray optics. Thin glass sheets are shaped into mirror segments by replicating the mold shape at high temperature. Heating parameters in the glass thermal slumping process are crucial to improve surface quality of the formed glass. In this research, the heating process of a thermal slumping glass sheet on a concave parabolic mold was simulated with the finite-element method (FEM) to investigate the effects of heating rate and soaking temperature. Based on the optimized heating conditions, glass samples 0.5 mm thick were formed in a furnace with a steel concave parabolic mold. The figure errors of the formed glass were measured and discussed in detail. It was found that the formed glass was not fully slumped at the edges, and should be trimmed to achieve better surface deviation. The root-mean-square (RMS) deviation and peak-valley (PV) deviation between formed glass and mold along the axial direction were 2.3 μm and 4.7 μm respectively.

High-speed angular-scan pulse-echo ultrasonic propagation imager for in situ non-destructive evaluation

  • Abbas, Syed H.;Lee, Jung-Ryul
    • Smart Structures and Systems
    • /
    • v.22 no.2
    • /
    • pp.223-230
    • /
    • 2018
  • This study examines a non-contact laser scanning-based ultrasound system, called an angular scan pulse-echo ultrasonic propagation imager (A-PE-UPI), that uses coincided laser beams for ultrasonic sensing and generation. A laser Doppler vibrometer is used for sensing, while a diode pumped solid state (DPSS) Q-switched laser is used for generation of thermoelastic waves. A high-speed raster scanning of up to 10-kHz is achieved using a galvano-motorized mirror scanner that allows for coincided sensing and for the generation beam to perform two-dimensional scanning without causing any harm to the surface under inspection. This process allows for the visualization of longitudinal wave propagation through-the-thickness. A pulse-echo ultrasonic wave propagation imaging algorithm (PE-UWPI) is used for on-the-fly damage visualization of the structure. The presented system is very effective for high-speed, localized, non-contact, and non-destructive inspection of aerospace structures. The system is tested on an aluminum honeycomb sandwich with disbonds and a carbon fiber-reinforced plastic (CFRP) honeycomb sandwich with a layer overlap. Inspection is performed at a 10-kHz scanning speed that takes 16 seconds to scan a $100{\times}100mm^2$ area with a scan interval of 0.25 mm. Finally, a comparison is presented between angular-scanning and a linear-scanning-based pulse-echo UPI system. The results show that the proposed system can successfully visualize defects in the inspected specimens.

Optical Encryption of Binary Information using 2-step Phase-shifting Digital Holography (2-단계 위상 천이 디지털 홀로그래피를 이용한 이진 정보 광 암호화 기법)

  • Byun, Hyun-Joong;Gil, Sang-Keun
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.5
    • /
    • pp.401-411
    • /
    • 2006
  • We propose an optical encryption/decryption technique for a security system based on 2-step phase-shifting digital holography. Phase-shilling digital holography is used for recording phase and amplitude information on a CCD device. 2-step phase-shifting is implemented by moving the PZT mirror with phase step of 0 or ${\pi}/2$. The binary data and the key are expressed with random code and random phase patterns. The digital hologram is a Fourier transform hologram and is recorded on CCD with 256 gray level quantization. We remove the DC term of the digital hologram fur data reconstruction, which is essential to reconstruct the original binary input data/image. The error evaluation fer the decrypted binary data is analyzed. One of errors is a quantization error in detecting the hologram intensity on CCD, and the other is generated from decrypting the data with the incorrect key. The technique using 2-step phase-shifting holography is more efficient than a 4-step method because 2-step phase-shifting holography system uses less data than the 4-step method for data storage or transmission. The simulation shows that the proposed technique gives good results fur the optical encryption of binary information.

Dielectric Thin Film Mirror Embedded Optical Fiber Couplers (유전체 박막 거울 내장형 광섬유 결합기)

  • 신종덕
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.420-427
    • /
    • 1993
  • Dielectric thin film mirrors are embedded in multimode and single-mode fibers by a fusion splicing technique. The fibers with $45{\circ}$ angled embedded mirrors serve as ultra-compact directional couplers with low excess optical loss of 0.2 dB for multimode and 0.5 dB for single mode at 1.3 ${\mu}m$ and excellent mechanical properties. The reflectance is wavelength dependent and strongly polarization depencient. Far-field scans of the reflected output power measured with a white-light source show a pattern which is almost circularly symmetric with aspect ratio of 1.09 at 5% of the peak power. The splitting ratio in a multimode coupler measured with a diode laser source is much less dependent on input coupling conditions than in conventional fused biconical-taper couplers, indicating that these couplers are less susceptible to modal noise occuring in optical fiber communication systems. Spectral properties of multilayer internal mirrors normal to the fiber axis have been investigated experimentally, and a matrix analysis has been used to explain the results.

  • PDF

A Study on the temperature sensing circuit using MOS applicable for the IC internal temperature measurement (IC 내부 온도측정이 가능한 MOS 온도센싱 회로에 관한 연구)

  • Kang, Byung-jun;Lee, Min-woo;Kim, Han-seul;Han, Jung-woo;Son, Sang-hee;Jung, on-sup
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.695-697
    • /
    • 2013
  • In this paper, temperature sensing circuit using by MOS is proposed. It produces the voltage as output and is applicable for the internal IC temperature measurement. It is designed by two current mirrors using MOS to implement the IC in the CMOS fabrication and is applicable for the various applications. It operates in two mode, temperature mode and sleep mode. From the simulation results, output voltage is measured from 0V to 1.2V by sweeping $0^{\circ}C{\sim}125^{\circ}C$ in temperature mode and output current flows under 100pA in sleep mode.

  • PDF

Direct Bonding of Si || SiO2/Si3N4 || Si Wafer Pairs With a Furnace (전기로를 이용한 Si || SiO2/Si3N4 || Si 이종기판쌍의 직접접합)

  • Lee, Sang-Hyeon;Lee, Sang-Don;Seo, Tae-Yun;Song, O-Seong
    • Korean Journal of Materials Research
    • /
    • v.12 no.2
    • /
    • pp.117-120
    • /
    • 2002
  • We investigated the possibility of direct bonding of the Si ∥SiO$_2$/Si$_3$N$_4$∥Si wafers for Oxide-Nitride-Oxide(ONO) gate oxide applications. 10cm-diameter 2000$\AA$-thick thermal oxide/Si(100) and 500$\AA$-Si$_3$N$_4$LPCVD/Si (100) wafers were prepared, and wet cleaned to activate the surface as hydrophilic and hydrophobic states, respectively. Cleaned wafers were premated wish facing the mirror planes by a specially designed aligner in class-100 clean room immediately. Premated wafer pairs were annealed by an electric furnace at the temperatures of 400, 600, 800, 1000, and 120$0^{\circ}C$ for 2hours, respectively. Direct bonded wafer pairs were characterized the bond area with a infrared(IR) analyzer, and measured the bonding interface energy by a razor blade crack opening method. We confirmed that the bond interface energy became 2,344mJ/$\m^2$ when annealing temperature reached 100$0^{\circ}C$, which were comparable with the interface energy of homeogenous wafer pairs of Si/Si.

Effects on Lethal Concentration 50%, Hematological Parameters and Plasma Components of Crucian carp, Carassius carassius Exposed to Waterborne Zinc (수인성 아연 급성 노출이 붕어, Carassius carassius의 반수치사농도, 혈액학적 성상 및 혈장 성분에 미치는 영향)

  • Ji-Ho, Jeong;Chang-Hoon, Joo;A-Hyun, Jo;Su-Min, Hong;Yun-A, Ryu;Seock-Won, Jo;Jun-Hwan, Kim
    • Journal of Marine Life Science
    • /
    • v.7 no.2
    • /
    • pp.129-138
    • /
    • 2022
  • Crucian carp, Carassius carassius (Weight 42.4 ± 9.0 g, Length 15.0 ± 1.0 cm) were exposed to waterborne zinc at 0, 5, 10, 20, 40 and 80 mg Zn2+/l for 96 hours. The lethal concentration 50 (LC50) at 96 hours of crucian carp, C. carassius exposed to waterborne zinc was 51.58 mg Zn2+/l. In hematological parameters, the RBC count was significantly decreased in the concentration of 40 mg Zn2+/l at 48 hours, whereas the hematocrit was significantly increased by zinc exposure. The MCV (mean corpuscular volume) (µl) and MCH (mean corpuscular hemoglobin) (pg) were significantly increased in the concentration of 40 mg Zn2+/l at 48 hours. The plasma components such as calcium, magnesium, glucose, cholesterol, total protein and ALT (Alanine aminotransminase) were significantly changed by zinc exposure. The results of this study suggest that the zinc exposure to C. carassius induced the significant physiological changes in the hematological parameters and plasma components as toxicity.