• Title/Summary/Keyword: Minimum damage

Search Result 392, Processing Time 0.027 seconds

Study on Fire Hazard Analysis along with Heater Use in the Public Use Facility Traditional Market in Winter (겨울철 다중이용시설인 전통재래시장 난방기구 사용에 따른 화재 위험성 분석에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.4
    • /
    • pp.583-597
    • /
    • 2014
  • Fire caused by heater has various causes as many as the types of heater. also, lots of damage of human life and property loss are caused, since annually continuous fire accident by heater in traditional market is frequently occurring. There are not many cases of fire due to heater in most of residential facilities such as general house, apartments, etc., because they are supplied with heating boiler, however the restaurant, store and office of the market, sports center, factory, workplace, etc. still use heater, e.g. oilstove, electric heater, etc., so that they are exposed to fire hazard. Also, when investigating the number of fire due to heater, it was analyzed to occur in order of home boiler, charcoal stove, oilstove, gas heater/stove, electric stove/heater, the number of fire per human life damage was analyzed in order of gas heater/stove, oil heater/stove, electric heater/stove, briquette/coal heater. Also, gas and oil related heater were analyzed to have low frequency, however, with high fire intensity. Therefore, this research aimed at considering more scientific fire inspection and identification approach by reenacting and reviewing fire outbreak possibility caused by combustibles' contact and conductivity under the normal condition and abnormal condition in respect of ignition hazard, i.e. minimum ignition temperature, carbonization degree and heat flux along with it, due to oilstove and electric stove, which are still frequently used in public use facility, traditional market, and, of which actual fire occurrence is the most frequent. As the result of reenact test, ignition hazard appeared very small, as long as enough heat storage condition is not made in both test objects(oilstove/electric stove), however carbonization condition was analyzed to be proceeded per each part respectively. Eventually, transition to fire is the ignition due to heat storage, so that it was analyzed to ignite when minimum heat storage temperature condition of fire place is over $500^{\circ}C$. Particularly, in case of quartz pipe, the heating element of electric stove, it is rapidly heated over the temperature of $600^{\circ}C$ within the shortest time(10sec), so that the heat flux of this appears 6.26kW/m2, which was analyzed to result in damage of thermal PVC cable and second-degree burn in human body. Also, the researcher recognized that the temperature change along with Geometric View Factor and Fire Load, which display decrease of heat, are also important variables to be considered, along with distance change besides temperature condition. Therefore, the researcher considers that a manual of careful fire inspection and identification on this is necessary, also, expects that scientific and rational efforts of this research can contribute to establish manual composition and theoretical basis on henceforth fire inspection and identification.

Antibacterial and Antioxidant Activity of Spermidine, a Natural Polyamine, on Fish Pathogenic Bacteria and C2C12 Myoblast Cells (어류병원성 세균 및 C2C12 근원세포에 대한 polyamine 계열 물질인 spermidine의 항균 및 항산화 활성)

  • Hwang-Bo, Hyun;Choi, Eun-Ok;Kim, Min Young;Ji, Seon Yeong;Hong, Su Hyun;Park, Cheol;Cha, Hee-Jae;Kim, Suhkmann;Kim, Heui-Soo;Hwang, Hye-Jin;Choi, Yung Hyun
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.11 no.2
    • /
    • pp.42-51
    • /
    • 2019
  • We compared the antibacterial activities of spermidine and astaxanthin against two gram-positive bacteria such as Streptococcus parauberis and S. iniae to find new antibacterial candidates. We also evaluated the preventive effects of spermidine against oxidative stress-induced cytotoxicity in C2C12 myoblasts. Our results indicated that spermidine has more significant antibacterial activities than astaxanthin against both two fish pathogenic bacteria as well as gram-negative bacteria Escherichia coli used as a control group. Minimum inhibitory concentration and minimum bactericidal concentration of spermidine were 0.25 mM and 1 mM against S. parauberis, 1 mM and 3 mM against S. iniae, and 0.5 mM and 1.5 mM against E. coli, respectively. In addition, the postantibiotic effect lasted from 7 h, 5 h and 6 h for S. parauberis, S. iniae and E. coli, respectively. The results also showed that the decreased C2C12 cell viability by H2O2 could be attributed to the induction of DNA damage and apoptosis accompanied by the increased production of reactive oxygen species, which was remarkably protected by spermidine. Additionally, the antioxidant effect of spermidine was associated with the activation of Nrf2 signaling pathway. According to the data, spermidine may be a potential lead compound which can be further optimized to discover novel antibacterial and antioxidant agents.

Evaluation of Structural Response of Cylindrical Structures Based on 2D Wave-Tank Test Due to Wave Impact (파랑충격력에 의한 원형실린더구조물의 구조응답평가)

  • Lee, Kangsu;Ha, Yoon-Jin;Nam, Bo Woo;Kim, Kyong-Hwan;Hong, Sa Young
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.5
    • /
    • pp.287-296
    • /
    • 2020
  • The wave-impact load on offshore structures can be divided into green-water and wave-slamming impact loads. These wave impact loads are known to have strong nonlinear characteristics. Although the wave impact loads are dealt with in the current classification rules in the shipping industry, their strong nonlinear characteristics are not considered in detail. Therefore, to investigate these characteristics, wave-impact loads induced by a breaking wave on a circular cylinder were analyzed. A model test was carried out to measure the wave-impact loads due to breaking waves in a two-dimensional (2D) wave tank. To generate a breaking wave, the focusing wave method was applied. A series of 2D tank tests under a horizontal wave impact was carried out to investigate the structural responses of the cylindrical structure, which were obtained from the measured model test data. According to the results, we proposed a structural damage-estimation procedure of an offshore tubular member due to a wave impact load. Furthermore, a recommended wave-impact load is suggested that considers the minimum required thickness of each member. From the experimental results, we found that the required minimum thickness is dependent on the impact pressure located in a three-dimensional space on the surface of a tubular member.

Evaluation of Hydraulic Stability Using Real Scale Experimental on Porous Concrete Revetment Block (다공성콘크리트 호안블록의 실규모 실험을 통한 수리안정성 평가)

  • Kim, Bong-Kyun;Seo, Dae-Seuk;Park, Jun-Seok;Kim, Yun-Yung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.2
    • /
    • pp.122-130
    • /
    • 2016
  • The past few decades of industrialization enabled human-centered stream developments, which in turn resulted in constructing straight or covered streams, which are used only for sewage disposal purpose. However, these types of streams have become the cause of flood damages such as localized heavy rain. In response, various construction methods have been implemented to prevent stream and embankment damages. However, regulations regarding these measures only lay out minimum standards such as the height of slopes and the minimum angle of inclination. Moreover, examination of tractive force, the most crucial factor in preventing flood damage, is nonexistent. Therefore, this study evaluates various tractive forces by implementing a porous concrete tetrapod at a full scale artificial stream for experiment, controlling the rate of inflow, and measuring the velocity and depth of the stream under different experiment conditions. The test results of the compressive strength, and porosity and density of rock of the porous concrete tetrapod was between 16.6 and 23.2 MPa, and the actual measurement of air void was 10.1%, thus satisfying domestic standard. The result of tractive force experiment showed a limiting tractive force of $47.202N/m^2$, not satisfying the tractive force scope of $67N/m^2$ the stream design working expertise proposes. However, there was neither damage nor loss of blocks and hardpan. Based on previous researches, it can be expected that there will be resistance against a stronger tractive force. Therefore, it is necessary to conduct another experiment on practical limiting tractive force by adjusting some experimental conditions.

Agrometeorological Analysis on the Freeze Damage Occurrence of Yuzu Trees in Goheung, Jeonnam Province in 2018 (2018년 전라남도 고흥 유자나무 동해 발생에 대한 기상학적 구명)

  • Kim, Gyoung Hee;Koh, Young Jin;Kim, Kwang-Hyung
    • Research in Plant Disease
    • /
    • v.25 no.2
    • /
    • pp.71-78
    • /
    • 2019
  • In 2018, severe diebacks have occurred on yuzu trees cultivated in Goheung, Jeonnam Province. On-farm surveys at 18 randomly selected orchards revealed the dieback incidence ranged from 7.5% to 100% with an average of 43.6%, and 56.6% of the affected yuzu trees were eventually killed. In order to find the reason for this sudden epidemic, we investigated the weather conditions that are exclusively distinct from previous years, hypothesizing that certain weather extremes might have caused the dieback epidemic on yuzu trees. Since different temperatures can cause freeze damage to plants depending on their dormancy stages, we investigated both periods when yuzu becomes hardy under deep dormancy (January-February) and when yuzu loses its cold hardiness (March-April). First, we found that daily minimum air temperatures below $-10^{\circ}C$ were recorded for 7 days in Goheung for January and February in 2018, while no occasions in 2017. In particular, there were two extreme temperature drops ($-12.6^{\circ}C$ and $-11.5^{\circ}C$) beyond the yuzu cold hardiness limit in 2018. In addition, another occasion of two sudden temperature drops to nearly $0^{\circ}C$ were occurred right after abnormally-warm-temperature-rises to $13^{\circ}C$ of daily minimum air temperatures in mid-March and early April. In conclusion, we estimated that the possible damages by several extreme freeze events during the winter of 2018 could be a major cause of severe diebacks and subsequently killed the severely affected yuzu trees.

A Study on the Disputable Issues of the Standard Form of Korea Service Contract - Focusing on Liquidated Damage and Minimum Quantity Commitment - (한국 컨테이너 해상화물 표준장기운송계약서 쟁점에 관한 연구 - 손해배상예정액과 최소약정물량을 중심으로 -)

  • Jae-woong Yoon;Yun-seok Hur
    • Korea Trade Review
    • /
    • v.48 no.2
    • /
    • pp.217-243
    • /
    • 2023
  • This study revealed practical implications by analyzing the clauses and disputable issues of the Korea Service Contract. Korea introduced Servcie Contract in the container part since Hanjin Shipping's bankrupcy and distributed the standard form(2019). After that, the standard form was revised during the supply chain crisis(2022). In the standard form, there are clause that require agreement due to conflicting interests of shipper and carrier. Therefore, the main clauses of the standard form were analyzed to derive the practical meaning to the both parties. In addition, in the process of introducing the standard form, the most disputable issues, liquidated damages and minimum quality commitment, were deeply analyzed to explain how shipper and carriers' benefit and loss differ as the clause changes. In conclusion, both parties must set LD at a very reasonable level so that they do not proceed separately with penalty. In addition, 'evenly' is a much more important than quantity for carrier in the establishment of MQC, so extra box option for shipper even during the peak season is needed to accommodate with service contract.

Proximal Policy Optimization Reinforcement Learning based Optimal Path Planning Study of Surion Agent against Enemy Air Defense Threats (근접 정책 최적화 기반의 적 대공 방어 위협하 수리온 에이전트의 최적 기동경로 도출 연구)

  • Jae-Hwan Kim;Jong-Hwan Kim
    • Journal of the Korea Society for Simulation
    • /
    • v.33 no.2
    • /
    • pp.37-44
    • /
    • 2024
  • The Korean Helicopter Development Program has successfully introduced the Surion helicopter, a versatile multi-domain operational aircraft that replaces the aging UH-1 and 500MD helicopters. Specifically designed for maneuverability, the Surion plays a crucial role in low-altitude tactical maneuvers for personnel transportation and specific missions, emphasizing the helicopter's survivability. Despite the significance of its low-altitude tactical maneuver capability, there is a notable gap in research focusing on multi-mission tactical maneuvers that consider the risk factors associated with deploying the Surion in the presence of enemy air defenses. This study addresses this gap by exploring a method to enhance the Surion's low-altitude maneuvering paths, incorporating information about enemy air defenses. Leveraging the Proximal Policy Optimization (PPO) algorithm, a reinforcement learning-based approach, the research aims to optimize the helicopter's path planning. Visualized experiments were conducted using a Surion model implemented in the Unity environment and ML-Agents library. The proposed method resulted in a rapid and stable policy convergence for generating optimal maneuvering paths for the Surion. The experiments, based on two key criteria, "operation time" and "minimum damage," revealed distinct optimal paths. This divergence suggests the potential for effective tactical maneuvers in low-altitude situations, considering the risk factors associated with enemy air defenses. Importantly, the Surion's capability for remote control in all directions enhances its adaptability in complex operational environments.

Predicting Highway Concrete Pavement Damage using XGBoost (XGBoost를 활용한 고속도로 콘크리트 포장 파손 예측)

  • Lee, Yongjun;Sun, Jongwan
    • Korean Journal of Construction Engineering and Management
    • /
    • v.21 no.6
    • /
    • pp.46-55
    • /
    • 2020
  • The maintenance cost for highway pavement is gradually increasing due to the continuous increase in road extension as well as increase in the number of old routes that have passed the public period. As a result, there is a need for a method of minimizing costs through preventative grievance Preventive maintenance requires the establishment of a strategic plan through accurate prediction old Highway pavement. herefore, in this study, the XGBoost among machine learning classification-based models was used to develop a highway pavement damage prediction model. First, we solved the imbalanced data issue through data sampling, then developed a predictive model using the XGBoost. This predictive model was evaluated through performance indicators such as accuracy and F1 score. As a result, the over-sampling method showed the best performance result. On the other hand, the main variables affecting road damage were calculated in the order of the number of years of service, ESAL, and the number of days below the minimum temperature -2 degrees Celsius. If the performance of the prediction model is improved through more data accumulation and detailed data pre-processing in the future, it is expected that more accurate prediction of maintenance-required sections will be possible. In addition, it is expected to be used as important basic information for estimating the highway pavement maintenance budget in the future.

Cytogenetic and Physiological Studies in Natural Populations of Torreya nucifera (비자나무 천연생집단(天然生集團)의 세포유전학적(細胞遺傳學的) 및 생리학적(生理學的) 연구(硏究))

  • Kim, Yeung Du;Kwon, Yeong Cheol
    • Journal of Korean Society of Forest Science
    • /
    • v.78 no.1
    • /
    • pp.42-54
    • /
    • 1989
  • These studies were carried out to examine the anatomical, karyological characteristics, the variation of isozymes in needle and the frost damage of tissue for the purpose of investigating the relationships among the three natural Torreya nucifera populations of Cheju-do, Namhae, and Mt. Naejang in Korea. The results obtained can be summed up as follows : 1. The numbers of endodermal cells and inner layer cells of mucilage canal of needle conductive tissue were different in each population. The number of those of Cheju-do population was the largest. 2. In somatic chromosome, Namhae population showed one more secondary constriction. The values of $b^{arm}/a^{arm}$ were the same in all the three populations, but Cheju-do population particularly showed a different minimum value. And the karyotype formulas of each population showed difference. 3. During the meiosis, each population showed no significant difference in the irregular phenomena of chromosome. 4. In isoperoxidase and esterase variations of needle, each population showed its particular number and variation of bands. Cheju-do population showed the largest number and greatest variation of bands. 5. Under the same freeging conditions, the frost damage of Mt. Naejang population was comparatively slight, and Cheju-do population suffered from a greater frost damage than the others.

  • PDF

Assessment of Composite Material Flaws on the Type III Cylinders for Compressed Natural Gas Vehicles (압축천연가스자동차용 Type III 용기의 복합재 결함 평가)

  • Kim, Young-Seob;Kim, Lae-Hyun;Yang, Dong-Ju
    • Journal of Energy Engineering
    • /
    • v.20 no.2
    • /
    • pp.90-95
    • /
    • 2011
  • This study was conducted to judge requalification of cylinders by assessing composite flaws such as scratches, cuts, and gouges damaging on the composite of Type III cylinders for compressed natural gas vehicles. As a result of the flaw tolerance test, all specimens have satisfied with minimum requirement cycles according to damage levels based on ISO 19078 and cyclic performance for pressure showed beyond twenty thousands in damage level 1 and 2, and did eighteen thousands to twenty-one thousands in damage level 3. Eight of twelve specimens failed the test due to composite flaws and the rest of the cylinders failed regardless of flaws. The results of Finite Element Method followed by the computer simulation indicated that the stress of 79.5 MPa calculated on the flaw model of $1.25\;mm{\times}200\;mm$ and the stress of 66.6 MPa on the non-flaw model when the service pressure applied to inside of cylinder. The difference between the models is about 19.37%. We concluded that this difference influences fatigue life and this flaw model is a critical value affecting cyclic performance of cylinders.