• Title/Summary/Keyword: Mini implant

Search Result 114, Processing Time 0.025 seconds

Analysis of time to failure of orthodontic mini-implants after insertion or loading

  • Jeong, Jong-Wha;Kim, Jong-Wan;Lee, Nam-Ki;Kim, Young-Kyun;Lee, Jong-Ho;Kim, Tae-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.5
    • /
    • pp.240-245
    • /
    • 2015
  • Objectives: This study was performed to evaluate patterns of failure time after insertion, failure rate according to loading time after insertion, and the patterns of failure after loading. Materials and Methods: A total of 331 mini-implants were classified into the non-failure group (NFG) and failure group (FG), which was divided into failed group before loading (FGB) and failed group after loading (FGA). Orthodontic force was applied to both the NFG and FGA. Failed mini-implants after insertion, ratio of FGA to NFG according to loading time after insertion, and failed mini-implants according to failed time after loading were analyzed. Results: Percentages of failed mini-implants after insertion were 15.79%, 36.84%, 12.28%, and 10.53% at 4, 8, 12, and 16 weeks, respectively. Mini-implant failure demonstrated a peak from 4 to 5 weeks after insertion. The failure rates according to loading time after insertion were 13.56%, 8.97%, 11.32%, and 5.00% at 4, 8, 12, and 16 weeks, respectively. Percentages of failed mini-implants after loading were 13.79%, 24.14%, 20.69%, and 6.9% at 4, 8, 12, and 16 weeks, respectively. Conclusion: Mini-implant stability is typically acquired 12 to 16 weeks after insertion, and immediate loading can cause failure of the mini-implant. Failure after loading was observed during the first 12 weeks.

TWO PART MINI-IMPLANT AS AN EFFICIENT TOOL FOR INTERMAXILLARY FIXATION (분리형 미니 임플란트를 이용한 효과적인 악간고정법의 소개)

  • Lee, Won;Kim, In-Soo;Seo, Woon-Kyung;Heo, Hyun-A;Kim, Seong-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.5
    • /
    • pp.477-482
    • /
    • 2006
  • The new type of orthodontic mini-implant named C-implant can be an effective alternative to conventional one-component mini-implant in the intermaxillary fixation (IMF) cases because of its particular design. The small size, two-part design, efficiency, and low cost of the C-implant make it applicable to various types of IMF cases easily such as fracture reduction and orthognathic surgery. The two part design resists highly to the fracture or deformation during implantation and removal. The long span head allows the patient to easily attach intermaxillary elastics, so that the patient can apply intermaxillary elastics for traction easily. Through this article, we tried to show the possibility of this appliance as a good adjunct for the IMF screw.

EFFECTIVE REDUCTION OF MANDIBULAR ANGLE FRACTURE WITH MINI-IMPLANT; CASE REPORT (Mini-implant를 이용한 하악골 우각부 골절의 효과적인 정복; 증례보고)

  • Yang, Byoung-Eun;Choi, Young-Jun;Choi, Won-Cheul
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.397-400
    • /
    • 2007
  • In an open reduction of the mandibular angle fracture, it is crucial to approximate each fracture segment as closer as possible for the reduction of the healing period. In this case report, we proposed a new technique for the mandibular angle fracture. This was designed to minimize the gap between two separated segments using mini-implants and surgical wires. Mini-implants were placed around the fracture line, followed by wire ligation to minimize the fracture gap. And then internal fixation was easily employed with plates and screws. The advantages of this technique were reduced time for operation, the promotion of healing, rapid functional recovery, and few complications.

Factors Associated with the Stability of Two-part Mini-implants for Intermaxillary Fixation

  • Kim, Seong-Hun;Seo, Woon-Kyung;Lee, Won;Kim, In-Soo;Chung, Kyu-Rhim;Kook, Yoon-Ah
    • Journal of Korean Dental Science
    • /
    • v.2 no.2
    • /
    • pp.24-30
    • /
    • 2009
  • Two component orthodontic C-implants have been introduced as intermaxillary fixation (IMF) screws in cases of periodontal problems with bone loss, severely damaged teeth, or short roots. This retrospective research sought to investigate the complications and risk factors associated with the failure of two-part C-implants for IMF cases and to show the possible indications compared to one-component mini-implants. The study sample consisted of 46 randomly selected patients who had a total of 203 implants. Pearson chi-square tests of independence were used to test for associations among categorical variables. At least 19 of the total 203 implants failed (9.3%). There was no significant difference in implant failure due to gender, oral hygiene, and placement, although a significant difference due to soft tissue characteristics and root contact was observed. The two-component design of the mini-implant is reliable for difficult IMF cases. Note, however, that the factors influencing implant failure were found to be age, root damage, and condition of soft tissues.

  • PDF

Peri-implant crevicular fluid levels of cathepsin-K, RANKL, and OPG around standard, short, and mini dental implants after prosthodontic loading

  • Alan, Raif;Marakoglu, Ismail;Haliloglu, Seyfullah
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.5
    • /
    • pp.169-177
    • /
    • 2015
  • Purpose: Despite the high success rates of endosseous dental implants, their placement is restricted according to the height and volume of bone available. The use of short or mini dental implants could be one way to overcome this limitation. Thus, this study aimed to compare standard, short, and mini dental implants with regard to associated clinical parameters and peri-implant crevicular fluid (PICF) levels of cathepsin-K (CTSK), RANK ligand (RANKL), and osteoprotegerin (OPG), after prosthodontic loading. Methods: A total of 78 non-submerged implants (Euroteknika, $Aesthetica^{+2}$, Sallanches, France) were installed in 30 subjects (13 male, 17 female; range, 26-62 years) who visited the clinic of the Periodontology Department, Faculty of Dentistry, Selcuk University. Sampling and measurements were performed on the loading date (baseline) and 2, 14, and 90 days after loading. Assessment of the peri-implant status for the implant sites was performed using the pocket probing depth (PPD), modified plaque index, modified gingival index, modified sulcular bleeding index, and radiographic signs of bone loss. PICF samples collected from each implant were evaluated for CTSK, RANKL, and OPG levels using the ELISA method. Keratinized tissue and marginal bone loss (MBL) were also noted. Results: Clinical parameters statistically significantly increased in each group but did not show statistical differences between groups without PPD. Although implant groups showed a higher MBL in the upper jaw, only the standard dental group demonstrated a statistically significant difference. At 90 days, the OPG:sRANKL ratio and total amounts of CTSK for each group did not differ from baseline. Conclusions: Within the limitations of this study, both short and mini dental implants were achieving the same outcomes as the standard dental implants in the early period after loading.

Removal torque of sandblasted large grit, acid etched treated mini-implant (Sandblasted large grit, acid etched 표면처리에 따른 교정용 미니 임플랜트의 제거회전력에 관한 연구)

  • Oh, Nam-Hee;Kim, Seong-Hun;Kook, Yoon-Ah;Lee, Keun-Hye;Kang, Yoon-Goo;Mo, Sung-Seo
    • The korean journal of orthodontics
    • /
    • v.36 no.5
    • /
    • pp.324-330
    • /
    • 2006
  • Objective: The purposes of this study were to evaluate the differences between sand blasted, large grit and acid-etched (SLA) treated mini-implants and smooth surface orthodontic mini-implants in relation to the removal torque as well as the histologic analysis. Methods: Custom-made, screw-shaped, titanium implants with a length of 9.5 mm and an outer diameter of 1.8 mm were divided into 2 groups; the SLA group (20 SLA treated orthodontic mini-implants) and the smooth surface group (20 smooth surface mini-implants), and placed In the tibia metaphysis of 10 rabbits. Each rabbit had 4 mini-implants placed, 2 in each tibia. The right tibia were implanted with the SLA group mini-implants and the left tibia had the smooth group mini-implants placed. Each mini-implant group were immediately applied with a continuous traction force of 150 g using a Ni-Ti coil spring. The rabbits were sacrificed 6 weeks post-surgically. Subsequently, the legs were stabilized, the Ni-Ti coil springs were removed and the mini-implants were removed under reverse torque rotation with a digital torque gauge. Results: 6 weeks after placement, the SIA group presented a higher mean removal torque value (8.29 Ncm) than the smooth group (3.34 Ncm) and histologic analysis revealed a higher new bone formation aspect along the screw in the SLA group. Conclusion: Results of this study indicates that SLA treated mini-implants may endure higher orthodontic forces without loosening.

MINI-IMPLANTS TO RESTORE MISSING TEETH IN SEVERE RIDGE DEFICIENCY AND SMALL INTERDENTAL SPACE (치조정 골 소실이 심한 경우와 치간 사이 공간이 부족한 경우에서의 미니 임프란트 식립)

  • Seo, Mi-Hyun;Yoo, Chung-Kyu;Lee, Eun-Kyung;Jung, Da-Unn;Suh, Je-Duck;Chung, Il-Hyuk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.31 no.1
    • /
    • pp.67-70
    • /
    • 2009
  • Purpose: This study presents the use of mini implants for fixed restoration and implant supported overdenture to enable the practitioner to overcome the anatomic obstacles of ridge width and narrow interdental space. Patients and methods: This study consisted of 9 patients who required single implants for one or two teeth replacement and 1 patient who required implant supported overdenture after mandiblectomy, iliac bone graft due to ghost cell tumor. The ages ranged from 29 to 70 years (mean 51). All patients were in good health. Clinical and radiographs were taken pretreatment, postoperatively, during rehabilitation, and at follow ups. Results: Total implant survival rate was 94.7%. One implant was removed due to its mobility as a result of bad bone quality (Type IV) and patient's carelessness (Heavy smoker). All patients except one reported complete satisfaction regarding to function, aesthetics, and phonetics. Radiographic follow up every 3months postoperatively showed success in achieving function and maintaining marginal bone level. Conclusion: Clinician can overcome both severe ridge deficiency and small interdental space with mini implant.

Effects of surface treatment on the osseointegration potential of orthodontic mini-implant (분사처리 후 산부식 표면처리된 교정용 미니 임플랜트의 골유착능에 관한 연구)

  • Jeon, Mi-Sun;Kang, Yoon-Goo;Mo, Sung-Seo;Lee, Keun-Bye;Kook, Yoon-Ah;Kim, Seong-Hun
    • The korean journal of orthodontics
    • /
    • v.38 no.5
    • /
    • pp.328-336
    • /
    • 2008
  • Objective: The purpose of this study was to compare the torque resistance to removal of sandblasted large grit and acid etched (SLA) surface treated orthodontic mini-implants and smooth surface orthodontic mini-implants as well as performing histologic observations. Methods: Two groups of custom screw shaped orthodontic mini-implants (C-implant, 1.8 mm outer diameter $\times$ 9.5 mm length, Cimplant, Seoul, Korea) were designated. 22 SLA treated C-implants (SLA group) and 22 machined surface C-implants (machined group) were placed in the tibia metaphysis of 11 adult New Zealand white rabbits. Following a 6-week healing period, the rabbits were sacrificed. Subsequently, the C-implants were removed under reverse torque rotation with a digital torque measuring device and independent t-test was performed. Selected tissues were prepared for histologic observation. Results: The SLA group presented a higher mean removal torque value (6.286 Ncm) than the machined group (4.491 Ncm) which was statistically significant (p < 0.005). Histologic observation revealed a trend of more new bone formation in contact with the screw surface in the SLA group than the smooth group. Conclusions: The results of this study suggested that SLA surface treatment can enhance the osseintegration potential for C-orthodontic mini-implants.

Correction of a maxillary canine-first premolar transposition using mini-implant anchorage (미니 임플란트 고정원을 이용한 전위된 상악 견치-제1소구치의 교정치료)

  • Oztoprak, Mehmet Oguz;Demircan, Cigdem;Arun, Tulin
    • The korean journal of orthodontics
    • /
    • v.41 no.5
    • /
    • pp.371-378
    • /
    • 2011
  • Transposition is defined as a dental anomaly manifested by a positional interchange of 2 adjacent teeth within the same quadrant of the dental arch. Maxillary canine-first premolar [Mx4-3] transposition is the most frequent tooth transposition reported in the literature. In this case report, an orthodontic correction of a transposition of the maxillary left canine and first premolar with the help of palatally located mini-implant anchorage is described. Esthetic and occlusal evaluations suggested alignment of the transposed teeth to their correct anatomic positions in the dental arch. The clinical result at the end of the treatment was satisfactory. Alignment was obtained, and intercuspation was adequate. Nevertheless, the maxillary canine showed facial recession, probably because it was initially positioned buccally. Supporting tissue was examined after treatment and no alveolar bone damage was observed.