MINI-IMPLANTS TO RESTORE MISSING TEETH IN SEVERE RIDGE DEFICIENCY AND SMALL INTERDENTAL SPACE

치조정 골 소실이 심한 경우와 치간 사이 공간이 부족한 경우에서의 미니 임프란트 식립

  • Seo, Mi-Hyun (Department of Dentistry-Oral and Maxillofacial Surgery, Seoul National University Boramae Hospital) ;
  • Yoo, Chung-Kyu (Department of Dentistry-Oral and Maxillofacial Surgery, Seoul National University Boramae Hospital) ;
  • Lee, Eun-Kyung (Department of Dentistry-Oral and Maxillofacial Surgery, Seoul National University Boramae Hospital) ;
  • Jung, Da-Unn (Department of Dentistry-Prosthodontics, Seoul National University Boramae Hospital) ;
  • Suh, Je-Duck (Department of Dentistry-Oral and Maxillofacial Surgery, Seoul National University Boramae Hospital) ;
  • Chung, Il-Hyuk (Department of Dentistry-Oral and Maxillofacial Surgery, Seoul National University Boramae Hospital)
  • 서미현 (서울대학교 보라매 병원 구강악안면외과) ;
  • 유충규 (서울대학교 보라매 병원 구강악안면외과) ;
  • 이은경 (서울대학교 보라매 병원 구강악안면외과) ;
  • 정다운 (서울대학교 보라매 병원 보철과) ;
  • 서제덕 (서울대학교 보라매 병원 구강악안면외과) ;
  • 정일혁 (서울대학교 보라매 병원 구강악안면외과)
  • Published : 2009.01.31

Abstract

Purpose: This study presents the use of mini implants for fixed restoration and implant supported overdenture to enable the practitioner to overcome the anatomic obstacles of ridge width and narrow interdental space. Patients and methods: This study consisted of 9 patients who required single implants for one or two teeth replacement and 1 patient who required implant supported overdenture after mandiblectomy, iliac bone graft due to ghost cell tumor. The ages ranged from 29 to 70 years (mean 51). All patients were in good health. Clinical and radiographs were taken pretreatment, postoperatively, during rehabilitation, and at follow ups. Results: Total implant survival rate was 94.7%. One implant was removed due to its mobility as a result of bad bone quality (Type IV) and patient's carelessness (Heavy smoker). All patients except one reported complete satisfaction regarding to function, aesthetics, and phonetics. Radiographic follow up every 3months postoperatively showed success in achieving function and maintaining marginal bone level. Conclusion: Clinician can overcome both severe ridge deficiency and small interdental space with mini implant.

Keywords

References

  1. Lazzara R. Criteria for implant selection: surgical and prosthetic considerations. Pract Periodontics Aesthet Dent 1994;6;55-62
  2. Hobo S, Icida E, Garcia LT. Osseointegration and occlusal rehabilitation. Chicago, Quintessence Publ Co Inc; 1989
  3. Azfar A. Siddiqui, Mark Sosovicka, Mark Goetz: Use of mini implants for replacement and immediate loading of 2 single-tooth restorations: a clinical case report. J Oral Implantol. 2006;32,2;Health Module:82-6 https://doi.org/10.1563/794.1
  4. Ivanoff CJ., Sennerby L., Johansson C., Rangert B., Lekholm U.,: Influence of implant diameters on the integration of screw implants: an experimental study in rabbits. Int J Oral Maxillofac Surg 1997;26:141-8 https://doi.org/10.1016/S0901-5027(05)80837-9
  5. Block MS., Delgado A., Fontenot MG.: The effect of diameter and length of hydroxylapatite-coated dental implants on ultimate pull out force in dog alveolar bone. J Oral Maxillofac surg 1990;48:174-8 https://doi.org/10.1016/S0278-2391(10)80206-X
  6. Paolo Vigolo, Andrea Givani: Clinical evaluation of singletooth mini-implant restoration: a five-year retrospective study. J Prosthet Dent 2000;84:50-4 https://doi.org/10.1067/mpr.2000.107674
  7. Trevor McClain Griffitts, Chad Patrick Collins, Patrick Charles Collins: Mini dental implants: an adjunct for retention. Stability, and comfort for the edentulous patient. Oral Surg Oral ed Oral Pathol Oral Radiol Endod 2005;100:E81-4 https://doi.org/10.1016/j.tripleo.2005.06.018
  8. Mi-Ra Ahn, Kyung-Mi An, Jung-Hwan Choi, Dong-Seok Sohn: Immediate loading with mini dental implants in the fully edentulous mandible. Implant Dent 2004;13:367-372
  9. Gargiulo AW, Wentz FM, Orban B. Dimensions and relations of the dentogingival junction in humans. J periodontal, 1961;32:261-267 https://doi.org/10.1902/jop.1961.32.3.261
  10. Tarnow DP, Cho SC, Wallace SS. The effect of interimplant distance on the height of inter-implant bone crest. J Periodontol. 2000;71:546-549 https://doi.org/10.1902/jop.2000.71.4.546
  11. Ziv Mazor, Marius Steigmann, Roy Leshem, Michael Peleg: Mini-implants to reconstruct missing teeth in severe ridge deficiency and small interdental space: a 5-year case series. Implant Dent 2004;13:336-341
  12. Bulard R. A., Vance J. B.: Multi-clinic evaluation using mini-dental implants for long-term denture stabilization: a preliminary biometric evaluation. Compend Contin Educ Dent 2005 Dec;26(12):892-7
  13. Rossein KD.: Retaining and stabilizing dentures with narrow-bodied implants. Dent Today. 2005;24:100, 102-106
  14. Christensen G. J.: The 'mini'-implant has arrived. J Am Dent Assoc 2006 Mar;137(3):387-90
  15. Shatkin T., Shatkin S., Oppenheimer A., Oppenheimer B.: A simplified approach to implant dentistry with mini dental implants. Alpha Omegan 2003;96:7-15
  16. Kido H., Schulz EE., Kumar A., Lozada J., Saha S.: Implant diameter and bone density: effect on initial stability and pull out resistance. J Oral Implantol 1997;23:163-9
  17. Kan JY, Rungcharassaeng K et al: Effects of smoking on implant success in grafted maxillary sinuses. J Prosthet Dent. 82: 307,1999 https://doi.org/10.1016/S0022-3913(99)70085-5
  18. Mazor Z.: Using transitional implants for immediate fixed temporary prosthesis. Dent Implantol Update. 2000;11:29-31
  19. Brown M, Tarnow D.: Fixed provisionallization with transitional implants for partially edentulous patients: a case study. Pract Periodontics Aesthet Dent. 2001;13:123-7