• Title/Summary/Keyword: Millimeter

Search Result 884, Processing Time 0.028 seconds

Developing an Instrument Ensuring Reliable Contact Conditions for Contact-Type Area-varying Capacitive Displacement Sensors (접촉식 면적변화형 정전용량 변위센서의 접촉 안정성을 위한 기구의 개발)

  • Kim, Sung-Joo;Lee, Won-Goo;Moon, Won-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1147-1156
    • /
    • 2011
  • A contact-type area-varying capacitive displacement sensor, or CLECDiS, can measure displacements over millimeter ranges with nanometer resolution. However, a small changes in the contact condition due to the surface profile or friction, which are inherent characteristics of contact-type sensors, lead to significant distortion of the output signal. Therefore, ensuring reliable contact conditions during CLECDiS measurements is the most important area to be improved in their actual use. Herein, in order to design an instrument for ensuring reliable contact conditions, the contact condition is analyzed by characterizing the signal distortion, observing the pressure distribution between the contacting surfaces, and measuring the motional errors of the sensor using a laser Doppler vibrometer (LDV). The manufactured instrument enables a CLECDiS to be used in an ultraprecise positioning system with improved reliability.

A Study on the Thermal-Hydraulic Characteristics of Molten Salt in Minichannels of an Intermediate Heat Exchanger for a Very High Temperature Reactor (VHTR) (초고온원자로 중간열교환기 미니챈널에서의 Molten Salt 열수력 특성 연구)

  • Jeong, Hui-Seong;Hwang, In-Seon;Bang, Kwang-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1093-1099
    • /
    • 2010
  • For Very High Temperature Reactors (VHTR), the designs of the Intermediate Heat Transport Loop (IHTL) and the Intermediate Heat Exchanger (IHX) are particularly difficult because of the high-temperature operation (up to $950^{\circ}C$). In this study, Flinak molten salt, a eutectic mixture of LiF, NaF, and KF (46.5:11.5:42.0 mole %) is considered as the heat transporting fluid in the IHTL. To evaluate the flow and heat transfer performance of the Flinak molten salt in small channels with hydraulic diameters in the millimeter range, a double-pipe heat exchanger was constructed using small-diameter tubes for the heat exchange between the Flinak and the gas flow. The experimental data showed that, for laminar Flinak flow, the measured friction factors were close to the 64/Re curve and the Nusselt numbers were generally between 3.66 and 4.36.

Novel Model for Nonlinearity of Traveling-Wave Electroabsorption Modulator according to Microwave Characteristics (마이크로파 특성에 따른 진행파형 전계흡수 변조기의 비선형 모델)

  • 윤영설;이정훈;최영완
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.8
    • /
    • pp.580-587
    • /
    • 2003
  • In this paper, we introduce a novel model to analyze the linearity of a TW-EAM (traveling-wave electroabsorption modulator). The device length, microwave loss (ML), and internal reflection (IR) due to impedance mismatch have effect on the linearity of a TW-EAM. The longer devices have characteristics of lower biases with minimum IMDS (intermodulation distortions). ML decreases the output power as well as the IMD value. Internal reflection has different nonlinear characteristics according to the wavelength of the input frequency and the device length. There is little change in SFDR (spurious-free dynamic range) due to ML or IR. As a result, for a 50 GHz band RF-optical communication system, a 0.8 mm-long TW-EAM with the lowest ML would have better properties by using n, which is caused by impedance, mismatch at the output port.

A Multi-Section Complex-Coupled DFB Laser with a Very Wide Range of Self-Pulsation Frequency and High Modulation Index (매우 넓은 영역의 Self-Pulsation 주파수와 높은 변조 지수를 가자는 다중 영역 복소 결합 DFB 레이저)

  • Kim, Boo-Gyoun;Kim, Tae-Young;Kim, Sang-Taek;Kim, Sun-Ho;Park, Kyung-Hyun
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.191-197
    • /
    • 2006
  • We analyze the self-pulsation(SP) characteristics due to mode beating of two modes emitted in a multi-section complex-coupled (CC) DFB laser composed of two DFB sections and a phase control section between them. SP frequency due to mode beating of the two modes is determined by the difference of grating periods in the two CC DFB regions. As the difference of grating periods in the two CC DFB regions increases, the SP frequency increases from very low frequency to the THz region. In the case of a mode which is not located in the stop band of the other DFB region, the mode propagates into the other DFB region without a high reflection, so that output powers emitted in a multi-section CC DFB laser have high modulation indexes due to the large interaction between the two modes.

Development of Ceramic Filter Using Non Radiative Microstrip Line In Millimeter-Wave (비방사 마이크로 스트립 선로를 이용한 밀리미터 대역의 세라믹 필터 개발)

  • Shin, Cheon-Woo;Kim, Tae-Heon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.6A
    • /
    • pp.648-656
    • /
    • 2007
  • This paper is about band pass filter, using Ceramics in the condition of center frequency 370Hz at milli-wave. The band pass filter is applied to Broadband Convergence Network, representing WLL(Wireless Local Loop) and LMDS(Local Multi-point Distribution Service). Sticking ceramic between strip line on a dielectric material substrate with which conductor's covers upper and basal surface, One will house the exterior by using structural resonance. In this Non Radiative Microstrip Line Filter structure, based upon simulations, generalized the two formulas finding resonant frequency of 1step ceramic resonator and bandwidth of 4step ceramic resonator. Also, As a result of experiment, using Network Analyzer, about created a experiment of structure based on the simulation result of 4-step ceramic resonator, It showed good characteristic of targeted bandwidth, comparing simulated result of 36.58GHz$\sim$37.650GHz with experimented result of 36.6GHz$\sim$37.65GHz.

Design and Fabrication of a Ka-Band 10 W Power Amplifier Module (Ka-대역 10 W 전력증폭기 모듈의 설계 및 제작)

  • Kim, Kyeong-Hak;Park, Mi-Ra;Kim, Dong-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.3
    • /
    • pp.264-272
    • /
    • 2009
  • In this paper, a Ka-band 10 W power amplifier module is designed and fabricated using MIC(Microwave Integrated Circuit) module technology which combines multiple power MMIC(Monolithic Microwave Integrated Circuit) chips on a thin film substrate. Modified Wilkinson power dividers/combiners are used for millimeter wave modules and CBFGC-PW-Microstrip transitions are utilized for reducing connection loss and suppressing resonance in the high-gain and high-power modules. The power amplifier module consists of seven MMIC chips and operates in a pulsed mode. for the pulsed mode operation, a gate pulse control circuit supplying the control voltage pulses to MMIC chips is designed and applied. The fabricated power amplifier module shows a power gain of about 58 dB and a saturated output power of 39.6 dBm at a center frequency of the interested frequency band.

Millimeter-Wave(W-Band) Forward-Looking Super-Resolution Radar Imaging via Reweighted ℓ1-Minimization (재가중치 ℓ1-최소화를 통한 밀리미터파(W밴드) 전방 관측 초해상도 레이다 영상 기법)

  • Lee, Hyukjung;Chun, Joohwan;Song, Sungchan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.8
    • /
    • pp.636-645
    • /
    • 2017
  • A scanning radar is exploited widely such as for ground surveillance, disaster rescue, and etc. However, the range resolution is limited by transmitted bandwidth and cross-range resolution is limited by beam width. In this paper, we propose a method for super-resolution radar imaging. If the distribution of reflectivity is sparse, the distribution is called sparse signal. That is, the problem could be formulated as compressive sensing problem. In this paper, 2D super-resolution radar image is generated via reweighted ${\ell}_1-Minimization$. In the simulation results, we compared the images obtained by the proposed method with those of the conventional Orthogonal Matching Pursuit(OMP) and Synthetic Aperture Radar(SAR).

A Study on the Unified Method of Coordinate Registration in Cadastral Map Information (지적도면정보 좌표등록의 통일화 방안 연구)

  • Hong, Sung-Eon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.11
    • /
    • pp.7855-7862
    • /
    • 2015
  • Cadastral map information is created by registering parcel information such as location, lot number, land category and boundary through the cadastral survey. However, with regard to boundary point coordinate, computerized cadastral information data was registered to either two decimal places (unit in centimeter) or three decimal places (unit in millimeter) so that a confusion in cadastral administration and cadastral survey has been caused. Therefore, the purpose of this study is to look for a method of matching two different coordinate systems through the consideration of registration of cadastral information data and area calculation. In conclusion, the result of the investigation not only shows that areal change and the creation of minute polygons resulted from land alteration could be solved by changing boundary point coordinate from two decimal places to three decimal places, but also suggests that the related laws and regulations to register boundary point coordinate to three decimal places should be institutionally corrected and applied.

APICAL SEALING OF THERMAFIL OBTURATORS IN CURVED CANALS (만곡근관에서 Thermafil의 근단폐쇄성에 관한 실험적 연구)

  • Ha, Joo-Hee;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.671-684
    • /
    • 1995
  • The purpose of this study was to compare the apical sealing ability, overfilling and obturation of lateral canals using two gutta-percha techniques: Thermafil obturators and cold lateral condensation. Eighty numbered epoxide blocks with one major and five lateral canals were divided into four experimental groups and obturated according to experimental groups. Four experimental groups were as follows: Group 1 : Filling with Thermafil plastic obturators and sealer(ThermaSeal) Group 2 : Filling with Thermafil plastic obturators only, without sealer(ThermaSeal) Group 3 : Fillng using lateral condensation with sealer(AH-26) Group 4 : Fillng using lateral condensation without sealer(AH-26) All the blocks were stored in 100% relative humidor at room temperature for 7 days. Each block was placed in centrifuge tube filled with India ink, and then centrifuged for 20 minutes at 3,000 rpm. Apical leakage was measured from the apical foramen to the most coronal level of dye penetration in millimeter under a stereoscope. The length of gutta-percha and sealer in each of the lateral canals was measured, too. The presence or absence of overfilling of gutta-percha and sealer was recorded. The data was analyzed by one-way ANOVA. The obtained results were as follows: l. Apical dye leakage was almost: not occurred in Group Willed with Thermafil and sealer) and Group 3(filled using lateral condensation with sealer), and there was no significant difference in linear leakage between two groups(p>0.01). 2. In both Thermafil and lateral condensation groups, linear leakage of Group I, 3(filled with sealer) was less than that of Group 2, 4(filled without sealer), and there was no significant difference in linear leakage between Group 1, 2, 3(p> 0.01). 3. Overfilling during obturation of Group 1, 2(filled with Thermafil) was more than Group 3, 4(filled using lateral condensation), and there was no significant difference between groups(p> 0.05). 4. Groups filled with Thermafil had significantly more gutta-percha than groups filled using lateral condensation in all lateral canals(p <0.01), the total length of gutta-percha and sealer found in all lateral canals were similar in Group 1 and Group 3.

  • PDF

EVALUATION OF APICAL PLUG MATERIALS USED FOR THE CONTROL OF EXTRUSION OF HIGH-TEMPERATURE THERMOPLASTICIZED GUTTA-PERCHA (수종의 apical plug 재료의 근단 폐쇄성에 관한 실험적 연구)

  • Hur, Eun-Jung;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.205-216
    • /
    • 1994
  • The purpose of this study is to evaluate of apical plug materials for the contral of extrusion and sealing ability of high-temperature thermoplasticized gutta-percha in plastic root canal blocks. Seventy seven plastic blocks with canal preformed were instrumented with # 50K file 1 mm beyond apical foramen. Blocks were randomly divided into 5 groups of 15 blocks each. Group 1 was filled by high-temperature thermoplasticized gutta-percha only. The another 4 groups were placed with apical plug materials each other and then remaining space was back filled with high temperature thermoplasticized gutta-percha Apical plug materials were used as follows; Group 2: Thermoplasticized gutta-percha (Thermoplasticized gutta-percha group) Group 3 :. Calcium hydroxide powder (Calcium hydroxide group) Group 4 : Silver point (Silver point group) Group 5 : Gutta-percha cone softened by chloroform (Gutta-percha cone group) All the blocks were stored in 100 % relative humidor at room temperature for 14 days. Filling material extruded was removed carefully and then weighed in analytic balance. Each block was placed in centrifuge tube filled with India ink, and then centrifuged for 20 minutes at 3,000 rpm. Apical leakage was measured from the apical foramen to the most coronal level of dye leakage in millimeter by two examiners under a stereoscope. The data were analysed statistically by Student's t-test The obtained results were as follows; 1. The amounts of material extruded through the foramen decreased in all of groups used apical plug materials (P<0.01). 2. Silver point group and gutta-percha cone group were similar linear leakage to high-temperature thermoplasticised gutta-percha technique only (P>0..5). 3. Calcium hydroxide group and thermoplasticized gutta-percha group showed more liner leakage than high-temperature thermoplasticized gutta-percha only (P<0.01, P<0.05). 4. High-temperature thermoplasticized gutta-percha technique with silver point and gutta-percha cone as apical plugs showed less linear leakage and less extrusion of filling material.

  • PDF