• 제목/요약/키워드: Microwave absorption

검색결과 172건 처리시간 0.026초

Effects of Size and Permittivity of Rat Brain on SAR Values at 900 MHz and 1,800 MHz

  • Hyun Jong-Chul;Oh Yi-Sok
    • Journal of electromagnetic engineering and science
    • /
    • 제6권1호
    • /
    • pp.47-52
    • /
    • 2006
  • The objective of this study is to evaluate the effects of size and permittivity on the specific absorption rate(SAR) values of rat brains during microwave exposure at mobile phone frequency bands. A finite difference time domain (FDTD) technique with perfect matching layer(PML) absorbing boundaries is used for this evaluation process. A color coded digital image of the Sprague Dawley(SD) rat based on magnetic resonance imaging(MRI) is used in FDTD calculation with appropriate permittivity values corresponding to different tissues for 3, 4, 7, and 10 week old rats. This study is comprised of three major parts. First, the rat model structure is scaled uniformly, i.e., the rat size is increased without change in permittivity. The simulated SAR values are compared with other experimental and numerical results. Second, the effect of permittivity on SAR values is examined by simulating the microwave exposure on rat brains with various permittivity values for a fixed rat size. Finally, the SAR distributions in depth, and the brain-averaged SAR and brain 1 voxel peak SAR values are computed during the microwave exposure on a rat model structure when both size and permittivity have varied corresponding to different ages ranging from 3 to 10 weeks. At 900 MHz, the simulation results show that the brain-averaged SAR values decreased by about 54 % for size variation from the 3 week to the 10 week-old rat model, while the SAR values decreased only by about 16 % for permittivity variation. It is found that the brain averaged SAR values decreased by about 63 % when the variations in size and permittivity are taken together. At 1,800 MHz, the brain-averaged SAR value is decreased by 200 % for size variation, 9.7 % for permittivity variation, and 207 % for both size and permittivity variations.

28 GHz 초전도 ECRIS 플라즈마에서의 마이크로파 전파 (Microwave Propagation in the Plasma for 28 GHz Superconducting ECRIS)

  • 왕선정;원미숙;이병섭;김선호;곽종구;정승호;김성규;안찬용
    • 한국진공학회지
    • /
    • 제19권6호
    • /
    • pp.467-474
    • /
    • 2010
  • 한국기초과학지원연구원 부산센터에서 개발 중인 28 GHz ECRIS에 대한 마이크로파 패킷의 전파와 흡수에 대한 분석을 제한된 변수 범위 내에서 실시하였다. 28 GHz 자이로트론에서 발생된 마이크로파는 도파관 시스템을 거쳐 자기장 및 플라즈마 캐비티의 축방향으로 입사된다. 축방향 자기장만을 고려한 분석적 Ray Tracying에 의하면 고자기장 영역에서 준 종파로 입사된 전자기 파동의 패킷은 전자 사이클로트론 공명 영역으로 진행함에 따라 바깥 방향에서 안쪽 방향으로 방향을 바꾼다. 따라서 일정 수준의 전자밀도가 유지되면 입사 초기에 발산하던 파동은 공명에 의하여 플라즈마로 흡수되기 전에 전도체인 플라즈마 캐비티 벽에 충돌할 가능성이 크지 않음을 확인하였다. 또한 플라즈마로의 흡수율이 매우 크므로 인출부 벽에서 반사될 가능성도 크지 않다.

정재파측정법과 Time Domain법에 의한 전파흡수능측정법의 비교 연구 (A Comparative Study on Measuring Methods of Absorption Characteristics for Electromagnetic Wave Using Standing Wave Measurement Method and Time Domain Method.)

  • 김동일;김상태;박지용;정세모
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1994년도 추계학술발표회
    • /
    • pp.79-90
    • /
    • 1994
  • The goal of this research is to get a measuring system for absorption characteristics of electromagnetic wave absorbers in ferrite type which are lat grid-type special type etc. It is however very difficult to measure the absorption characteristics as in low frequency as in 30 MHz, To solve the problem therefore we propose a standing wave method and a measurement method in time domain using parallel striplines construct the measuring system and measure the characteristics of ferrite microwave absorbers in grid type using the proposed measuring system.

  • PDF

Time Domain법에 의한 전파흡수체의 흡수능 측정법의 비교연구 (A Comparative Study on Measuring Methods of Absorption Characteristics for Electromagnetic Wave Absorber Using Time Domain Method)

  • 김동일;김상태;박지용;정세모
    • 한국전자파학회지:전자파기술
    • /
    • 제6권2호
    • /
    • pp.11-18
    • /
    • 1995
  • 본 연구는 평판형, 그리드형, 특수형상 등의 페라이트 전파흡스체의 흡수능 측정시스템을 구축하는 데에 목적이 있다. 그러나 30MHz와 같이 낮은 주파수에서 흡수능을 측정하느 것은 대단히 곤란 . 이와같은 문제를 해결하기 위하여 평행평판 스 라인을 사용하여 정재파측정법 및 시간영역법을 제안하였으며, 실제 측정시스템을 구성하요 제안한 측정볍으로 그리드형 페라이트 전자파흡수체의 특성을 측정. 평가하였다.특성을 측정. 평가하였다.

  • PDF

휴대전화 단말기용 전파흡수체의 개발에 관한 연구 (A Study on Development of EM Wave Absorbers for Mobile Phones)

  • 정재현;김동일
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 후기학술대회논문집
    • /
    • pp.67-68
    • /
    • 2005
  • This thesis is concerned with basic research for development of EM wave absorbers in sheet type for mobile phones. By controlling the sendust ratio, the $Al(OH)_3$ coating, the thickness, the kind of binders, EM wave absorbers were prepared and examined. Centeral frequency shifts toward lower with increasing thickness of the absorber, and absorption ability controlled to adjust Sendust amount. The absorption band of the EM wave absorber coated with $Al(OH)_3$ becomes larger than that of non-coated one. Sendust composite microwave absorbers mixed with CPE were prepared at $70^{\circ}C$ in temperature. The fabricated EM wave absorbers show a reflection coefficient 5.56 dB at 1.8 GHz in thickness of 0.85 mm.

  • PDF

Comparative simulation of microwave probes for plasma density measurement and its application

  • 김대웅;유신재;김시준;이장재;김광기;이영석;염희중;이바다;김정형;오왕열
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.185.2-185.2
    • /
    • 2016
  • The plasma density is an essential plasma parameter describing plasma physics. Furthermore, it affects the throughput and uniformity of plasma processing (etching, deposition, ashing, etc). Therefore, a novel technique for plasma density measurement has been attracting considerable attention. Microwave probe is a promising diagnostic technique. Various type of cutoff, hairpin, impedance, transmission, and absorption probes have been developed and investigated. Recently, based on the basic type of probes, modified flat probe (curling and multipole probes), have been developing for in situ processing plasma monitoring. There is a need for comparative study between the probes. It can give some hints on choosing the reliable probe and application of the probes. In this presentation, we make attempt of numerical study of different kinds of microwave probes. Characteristics of frequency spectrum from probes were analyzed by using three-dimensional electromagnetic simulation. The plasma density, obtained from the spectrum, was compared with simulation input plasma density. The different microwave probe behavior with changes of plasma density, sheath and pressure were found. To confirm the result experimentally, we performed the comparative experiment between cutoff and hairpin probes. The sheath and collision effects are corrected for each probe. The results were reasonably interpreted based on the above simulation.

  • PDF

마이크로파 조사에 따른 개질화 활성탄의 온도특성 및 벤젠흡착 (Temperature Characteristics of the Modified GAC by Microwave Irradiation and Benzene Adsorption)

  • 최성우;김윤갑
    • 한국환경과학회지
    • /
    • 제15권6호
    • /
    • pp.579-586
    • /
    • 2006
  • The purposes of this paper were to monitor the temperature rising courses and spark discharge of the modified granular activated carbon (GAC) by microwave (MW) irradiation and to evaluate absorption of benzene. The GAC coated on $SiO_2$, boron, talc, ferrite was named as the modified GAC. Thermal and spark discharge measurement of virgin GAC and modifed GAC has been carried out using a MW device operating at 2450 MHz under various energy conditions. The results of this paper as follows. First, the modified GAC is more efficient than the virgin GAC in temperature control. Temperature gradient of the modified GAC is more lower than that of virgin GAC. The temperature gradient of GAC was observed in the following order : virgin GAC, Mn-Zn ferrite/GAC, Ni-Zn ferrite,/GAC, $SiO_2/GAC$, Boron/GAC, Talc/GAC. Second, the spark discharge of the modified GAC was diminished, compared with that of virgin GAC. Because of its excellent electrical insulating properties, the coating material prevents the spark discharge. Finally, the benzene adsorption capacity of the modified GAC decreased due to diminishing of adsorption site by the coating material. Considering the temperature gradient and spark discharge of GAC, the GAC coated $SiO_2$ would be appropriate absorbent under irradiation of MW.

마이크로파 나선형 안테나의 제작과 온열분포 (Design and Thermal Distribution of Microwave Spiral Antenna)

  • 이경자
    • Radiation Oncology Journal
    • /
    • 제8권2호
    • /
    • pp.155-162
    • /
    • 1990
  • 마이크로파온열요법은 피부 및 국소종양에 대한 방사선과 병행요법으로서 치료성과를 얻고 있다. 저자들은 가정용 전기오븐을 이용하여 온도측정 및 조절장치를 할 수 있는 마이크로파온열기를 개발하여 적용가능한 환자를 치료하여 왔다. 그러나 선형단극 안테나로 제작된 applicator는 가열 깊이가 2\~4\;cm$로 낮고 온도분포가 불균일하여 많은 어려움이 있었다. 저자들은 안테나의 길이를 마이크로파의 파장과 같거나 배수로 하여 효율을 높게 하고 모양을 나선형으로 한 applicator를 여러개 제작하여 온열분포를 측정하였다. 안테나 길이가 파장과 같은 12.2cm이고 직경 4 cm 의 나선형모양을 가진 applicator의 온열분포가 대칭적이고 넓으며 (FWHM =3.5 cm) 보다 깊이 가열할 수 있어 ($D_{eff}=4\;cm$) 온열치료에 많은 도움을 줄 수 있다고 사료된다.

  • PDF

촉매 화학 기상 증착법의 제조 조건에 따른 탄소 나노튜브의 특성 (Characteristics of Carbon Nanotube with Synthetic Conditions in Catalytic Chemical Vapor Deposition)

  • 김현진;이임렬
    • 한국재료학회지
    • /
    • 제12권6호
    • /
    • pp.458-463
    • /
    • 2002
  • Carbon nanotubes were synthesized at various conditions using Ni-catalytic thermal chemical vapor deposition method and their characteristic properties were investigated by SEM, TEM and Raman spectroscopy. Carbon nanotubes were formed on very fine Ni-catalytic particles. The carbon nanotubes synthesized by thermal decomposition of acetylene at $700^{\circ}C$ had a coiled shape, while those synthesized at $850^{\circ}C$ showed a curved and Y-shape having a bamboo-like morphology. It was found that the carbon nanotube was also made on the fine Ni-catalytic particles formed on the surface of 100~400nm sized large ones after pretreatment with $NH_3$.ber composites show the high dielectric constant and large conduction loss which is increased with anisotropy of fiber arrangement. It is, therefore, proposed that the glass and carbon fiber composites can be used as the impedance transformer (surface layer) and microwave reflector, respectively. By inserting the foam core or honeycomb core (which can be treated as an air layer) between glass and carbon fiber composites, microwave absorption above 10 dB (90% absorbance) in 4-12 GHz can be obtained. The proposed fiber composites laminates with sandwitch structure have high potential as lightweight and high strength microwave absorbers.

Large Area Diamond Nucleation and Si (001) Using Magnetoactive Microwave Plasma Chemical Vapor Deposition

  • Hyeongmin Jeon;Akimitsu Hatta;Hidetoshi Suzuki;Nam Jiang;Jaihyung Won;Toshimichi Ito;Takatomo Sasaki;Chongmu Lee;Akio Hiraki
    • The Korean Journal of Ceramics
    • /
    • 제3권3호
    • /
    • pp.159-162
    • /
    • 1997
  • Diamond was uniformly nucleated on large area Si(001) substrate (3cm$\times$4cm) using the low pressure magnetoactive microwave plasma chemical vapor deposition. $CH_4/He$ gas mixture was used as source gas in order to obtain high radical density in the nucleation enhancement step. $CH_3$radical density was measured by means of infrared laser absorption spectroscopy. The effect of substrate bias voltage on diamond nucleation was examined. The results showed that a suitable positive bias voltage appled to the substrate with respect to the chamber could enhance diamond nucleation while a negative bias voltages leaded to deposition of only non-diamond phase carbon.

  • PDF