• Title/Summary/Keyword: Microwave Antennas

Search Result 109, Processing Time 0.028 seconds

Performance Analysis of Distributed Antenna Systems with Antenna Selection over MIMO Rayleigh Fading Channel

  • Yu, Xiangbin;Tan, Wenting;Wang, Ying;Liu, Xiaoshuai;Rui, Yun;Chen, Ming
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.8 no.9
    • /
    • pp.3016-3033
    • /
    • 2014
  • The downlink performance of distributed antenna systems (DAS) with antennas selection is investigated in Rayleigh fading multicell environment, and the corresponding system capacity and bit error rate (BER) analysis are presented. Based on the moment generating function, the probability density function (PDF) and cumulative distribution function (CDF) of the effective signal to interference plus noise ratio (SINR) of the system are first derived, respectively. Then, with the available CDF and PDF, the accurate closed-form expressions of average channel capacity and average BER are further derived for exact performance evaluation. To simplify the expression, a simple closed-form approximate expression of average channel capacity is obtained by means of Taylor series expansion, with the performance results close to the accurate expression. Besides, the system outage capacity is analyzed, and an accurate closed-form expression of outage capacity probability is derived. These theoretical expressions can provide good performance evaluation for DAS downlink. It can be shown by simulation that the theoretical analysis and simulation are consistent, and DAS with antenna selection outperforms that with conventional blanket transmission. Moreover, the system performance can be effectively improved as the number of receive antennas increases.

A 2.4 GHz-Band 100 W GaN-HEMT High-Efficiency Power Amplifier for Microwave Heating

  • Nakatani, Keigo;Ishizaki, Toshio
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.2
    • /
    • pp.82-88
    • /
    • 2015
  • The magnetron, a vacuum tube, is currently the usual high-power microwave power source used for microwave heating. However, the oscillating frequency and output power are unstable and noisy due to the low quality of the high-voltage power supply and low Q of the oscillation circuit. A heating system with enhanced reliability and the capability for control of chemical reactions is desired, because microwave absorption efficiency differs greatly depending on the object being heated. Recent studies on microwave high-efficiency power amplifiers have used harmonic processing techniques, such as class-F and inverse class-F. The present study describes a high-efficiency 100 W GaN-HEMT amplifier that uses a harmonic processing technique that shapes the current and voltage waveforms to improve efficiency. The fabricated GaN power amplifier obtained an output power of 50.4 dBm, a drain efficiency of 72.9%, and a power added efficiency (PAE) of 64.0% at 2.45 GHz for continuous wave operation. A prototype microwave heating system was also developed using this GaN power amplifier. Microwaves totaling 400 W are fed from patch antennas mounted on the top and bottom of the microwave chamber. Preliminary heating experiments with this system have just been initiated.

Experimental Measurement System for 3-6 GHz Microwave Breast Tomography

  • Son, Seong-Ho;Kim, Hyuk-Je;Lee, Kwang-Jae;Kim, Jang-Yeol;Lee, Joon-Moon;Jeon, Soon-Ik;Choi, Hyung-Do
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.4
    • /
    • pp.250-257
    • /
    • 2015
  • This paper presents an experimental measurement system for 3-6 GHz microwave tomography (MT) of the breast. The measurement system is constructed as a minimal test bed to verify key components such as the sensing antennas, radio frequency (RF) transceiver, sensing mechanism, and image reconstruction method for our advanced MT system detecting breast cancer at an early stage. The test bed has eight RF channels operating at 3 to 6 GHz for high spatial resolution and a two-axis scanning mechanism for three-dimensional measurement. The measurement results from the test bed are shown and discussed.

2D Microwave Image Reconstruction of Breast Cancer Detector Using a Simplex Method and Method of Moments

  • Kim, Ki-Chai;Cho, Byung-Doo;Kim, Tae-Hong;Lee, Jong-Moon;Jeon, Soon-Ik;Pack, Jeong-Ki
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.199-205
    • /
    • 2010
  • This paper presents a tumor detection system for breast cancer that utilizes two-dimensional (2D) image reconstruction with microwave tomographic imaging. The breast cancer detection system under development consists of 16 transmit/receive antennas, and the microwave tomography system operates at 900 MHz. To solve a 2D inverse scattering problem, the method of moments (MoM) is employed for forward problem solving, and the simplex method employed as an optimization algorithm. The results of the reconstructed image show that the method accurately shows the position of a breast tumor.

On the measurement of characteristics of antennas for indoor digital TV (실내 디지털 TV용 안테나 특성 측정에 관하여)

  • Park, Jin-Taek;Lee, Jong-Ig;Yeo, Junho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2345-2350
    • /
    • 2014
  • In this paper, measurement methods for the characteristics of antennas for indoor digital TV (DTV), having 75-ohm port impedance, are introduced. Reference impedance of typical radio frequency (or microwave) systems and measurement equipments is 50 ohm. However, the reference impedance of antennas for indoor DTV is 75 ohm, and the characteristics of the antennas cannot be measured directly using the measurement equipments. Measurement methods, using test equipments with reference impedance of 50 ohm, for the characteristics(impedance, radiation patterns, and gain) of antennas designed to fit for 75 ohm port are introduced.

On the measurement of characteristics of planar antennas for indoor digital TV (실내 디지털 TV용 평면 안테나 특성 측정에 관하여)

  • Lee, Jong-Ig;Yeo, Junho;Kim, Soo-Min;Yang, Myung-Kyu;Eun, Jang-Soo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.45-46
    • /
    • 2014
  • In this paper, measurement methods for the characteristics of antennas for indoor digital TV (DTV), having 75-ohm port impedance, are introduced. Reference impedance of typical radio frequency (or microwave) systems and measurement equipments is 50 ohm. However, the reference impedance of antennas for indoor DTV is 75 ohm, and the characteristics of the antennas cannot be measured directly using the measurement equipments. Measurement methods, using test equipments with reference impedance of 50 ohm, for the characteristics(impedance, radiation patterns, and gains) of antennas designed to fit for 75 ohm port are introduced.

  • PDF

Characterizations of Spherical Luneburg Lens Antennas with Air-gaps and Dielectric Losses

  • Kim, Kang-Wook
    • Journal of electromagnetic engineering and science
    • /
    • v.1 no.1
    • /
    • pp.11-17
    • /
    • 2001
  • In this paper, spherical Luneburg lens antennas have been systematically analyzed using the Eigenfunction Expansion Method (EEM), The developed technique has capability of performing a complete 3-D analysis to characterize the multi-layered dielectric spherical lens with arbitrary permittivity and permeability. This paper describes the analysis technique, and presents the results of the parametric study of Luneburg lens antennas by varying design parameters suoh as the diameter of the lens antenna (up to 80 wavelength), number of spherical shells (up to 30 shells), air-gaps between spherical shells, and dielectric loss of the material. Many representative engineering design curves including the far-field patterns, wide-angle sidelobe characterizations, antenna efficiency have been presented.

  • PDF

2003 Asia Pacific Microwave Conference (2003아시아 태평양 마이크로파 학술회의)

  • 김동일;이혁재;박동철;명로훈;윤상원;조영기;남상욱;윤영중;이해영
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2004.01a
    • /
    • pp.1-226
    • /
    • 2004
  • I. Title APMC'03(2003 Asia Pacific Microwave Conference) II. Objecuve $\bigcirc$Investigation of new trend in the field of microwave engineering $\bigcirc$Establishment of R&D track for wireless and high speed communication III. Scope of investigation $\bigcirc$R&D trend in various microwave engineering areas-Solid state Devices and circuits-Electromagnetic Field Theory-EMI&EMC-Phased & Active Array Antennas-Scattering & Propagation $\bigcirc$Discussions with various technical topics-New research & development topics-Establishment of wireless & high speed communications IV. Results During the conference, very active academic exchange were possible between Korean and foreign microwave engineering scholars. It was also possible to introduce the level and activities of Korean microwave engineering researches to foreign countries. Also, it was good opportunity to contact foreign scholars and researchers for valuable academic discussion using technical paper presentations and inquiries.

  • PDF

Fabrication and characteristic analysis of High-Tc superconducting microstrip antennas using direct inset feeding technique (직접삽입 급전 방식을 이용한 고온초전도 마이크로스트립 안테나의 제작 및 특성 해석)

  • Chung, Dong-Chul;Han, Byoung-Sung;Kim, Jin;Ryu, Ki-Su;Hong, Suck-Yong;Lee, Jong-Ha
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.37 no.1
    • /
    • pp.70-78
    • /
    • 2000
  • In applying high-${\underline{T_c}}$ superconducting material to microwave devices, Uncertainty of electromagnetics of high-${\underline{T_c}}$ superconductor(HTS) and the temperature dependence of the substrate fits with HTS thin film cause difficulty in realization of such antenna for industrial applications. It must be noted to characteristic the HTS antenna in contrast with normal conducting counterpart for this real application. In this paper, a comparative study between HTS microstrip antennas and gold antennas was reported in terms of the return loss, the characteristic impedance, efficiency, and other various characteristics. HTS thin films were $YBa_2Cu_3O_{7-x}$ (YBCO) on MgO substrates. Superconducting microstrip antennas used in this work were to directly inset a microstrip transmission line into the 50 ${\Omega}$ region of the radiating patch. Measurement results of HTS antennas and gold antennas showed that usable antennas can be made using this architecture.

  • PDF

A Free-Space Method for Measurement and Analysis of Dielectric Characteristics of Electromagnetic Absorbing Materials at Microwave Frequencies (자유공간 기법을 적응한 마이크로파 대역 전파흡수재의 유전 특성 분석)

  • 배근식
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.73-82
    • /
    • 2003
  • For measurements and analysis of dielectric characteristics of planar slabs of microwave absorbing materials, I have applied a free-space method in the frequency range of 8~14 GHz. The measurement system for free-space method consists of transmit and receive antennas, mode transitions, precision coaxal cables, the network analyzer, and a computer Special Spot-focused horn lens antenna was used to eliminate diffraction effects. Diffraction effects at the edges of the sample are minimized by satisfying the condition for minimum transverse dimension of the plate and the beamwidth of the antennas at the focus. The time-domain gating feature of the network analyzer and the thru, reflect, and line(TRL) calibration technique were used to eliminate the effects of undesirable multiple reflections. The complex coefficients of reflection and transmission, $S_{11}$ and $S_{21}$, of planar samples were measured for standard materials such as Teflon, Rexolite$\textregistered$ 2200. The results were compared with existing measurement method. And I applied a free-space method for measurement to measure dielectric constants of some electromagnetic absorbing materials. Dielectric properties for the same samples were also measured with a 7mm coxial transmission line method for purposes of comparison with the free-space method.