• Title/Summary/Keyword: Microtron

Search Result 11, Processing Time 0.022 seconds

MM-22 Medical Microtron Accelerator for Radiotherapy (방사선 치료용 MM-22 의학용 마이크로트론 가속기)

  • Lee Dong-Hun;Bak Joo-Shik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.4 no.1
    • /
    • pp.47-52
    • /
    • 1990
  • The MM-22 medical microtron at Korea Cancer Center Hospital has been running for radiotherapy since it was installed in 1986. The microtron is a very flexible radiation therapy device with excellent radiation field for photon or electron therapy. The microtron accelerates elections from an energy of minimun 5.3MeV to an energy of maximum 22.5MeV. The electrons are led from the microtron to the treatment head via a beam transport system and are used for radiotherapy. Present paper describes the system structures and operating characteristics of the MM-22 microtron and its therapy unit.

  • PDF

The Emission and Characteristics Measurement of Electron Beam and Basis Construction for Education Usage (전자빔 인출 및 빔 계측과 교육 활용을 위한 기반구축)

  • Lee, Dong-Hoon
    • Journal of IKEEE
    • /
    • v.11 no.4
    • /
    • pp.257-264
    • /
    • 2007
  • The MM22 microtron has used as a cancer therapy machine from Nov. 1986 to Feb. 2006. This machine was moved and installed to a radiation research center to use as an education and research tool from treatment machine because of aging of MM22 microtron. In this paper, for extracting the electron beam from microtron, operation principle of the microtron, system characteristics of each module, and pulse structures were reviewed. The beam extraction and measurement were performed after measuring pulses of each major module and extraction trials in the beam line. After finishing the movement of MM22 microtron, the 30mA target current in the case of 10 MV X-ray beam was extracted and the beam flatness of radiation distribution was acquired within 3% error ratio after 100 MU was irradiated on X-omatV Film at SSD 100 cm and field size $10{\times}10cm^2$. As a result, the microtron movement and new installation was performed with success.

  • PDF

A Study on the dose distribution and the accuracy of the system for small fields of high energy x-rays (고에너지 X-선 소조사야의 선량분포 및 계측에 관한 연구)

  • 이호남;지광수;김재휴;지영훈
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.32-44
    • /
    • 1995
  • I. 제 목 고에너지 X-선 소조사야의 선량분포 및 계측에 관한 연구 II. 연구의 목적 및 중요성 최근 수술이 어려운 뇌종양등에 대한 방사선수술법(Radiosurgery)이 관심의 대상이 되고 있다. 방사선수술법은 크게 나누어 200여개의 Co-60이 장착된 장치(Gamma Knife)를 이용하는 방법과, X-선치료기를 이용하는 방법은 몇개의 보조기구를 설치하면 가능한 매우 경제적인 방법이다. 따라서 Microtron을 이용한 방사선수술의 기초자료확보를 위하여 소조사야에 대한 선량과 선량분포의 측정 및 계산을 실시하였다. III. 연구의 내용 및 범위 Microtron으로부터 조사되는 6MV, 10MV, 21MV X-선의 지름 3cm이하 소조사야에 대한 정확한 선량 및 선량분포 자료를 확보하기 위해, 가. Microtron치료기와 보조장치등에 대한 정밀도 계측 및 평가 나. 보조 Collimator의 적당한 크기와 재료의 선택 및 설계, 제작. 다. 에너지와 조사야 크기 각각에 대한 여러측정장치(Ion chamber, Diode detector, TLD 및 Film등)를 이용한 선량 및 선량분포 측정. 라. 측정값들의 비교, 검토 및 측정된 자료에 의한 선량 및 선량분포의 계산을 수행했다. IV. 연구결과 및 활용에 대한 건의 본 연구에서 얻은 결과는 다음과 같다. 가. Microtron치료기와 보조장치등의 정확도의 허용 오차범위내에서 잘 일치하였다. 나. 보조 collimater adpator는 총 길이 24cm로 하였으며 재질로는 두랄미늄을 사용하였고, 보조 collimator는 low melting alloy를 사용하였으며 소조사야 크기의 정확도는 0.5mm이내에서 매우 잘 일치 하였다. 다. 방사선 수술법의 에너지 선택에 중요한 요소중의 하나인 penumbra는 6MV X-선에서 가장 적게 나타났으며 라. 소조사면에 대한 깊이-선량 백분율곡선은 모든 에너지에서 조사면이 작아질수록 표면으로 이동하는 경향을 보였다. 이상의 결과로부터 방사선 수술을 시행할 경우 수십억원에 이르는 장비의 도입이나 새로운 시설 없이 Microtron에서 조사되는 고에너지 X-선을 이용할 수 있을 것으로 사료된다. 또한 새로 구입한 측정기나 보조 Collimator를 이용하여 소조사야에 대한 선량측정기술을 습득함으로써 일반적인 소조사야의 방사선치료나 회전치료등에 활용할 수 있다.

  • PDF

ACTIVATION ANALYSIS OF ENVIRONMENTAL SAMPLES USING THE MT-25 MICROTRON OF THE FLNR

  • Maslov, O.D.;Belov, A.G.;Starodub, G.Ya.;Dmitriev, S.N.
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.815-820
    • /
    • 1995
  • Instrumental neutron and gamma activation analysis of coal and combustion products, determination of platinum content in natural samples by radiochemical gamma activation analysis and high-sensitive track method of thorium determination has been studied with the use of the MT-25 microtron.The optimal conditions for complete elemental analysis of coal and combustion products, isolation and determination of platinum and thorium are recommended.

  • PDF

Design Features and Operating Characteristics of the MM-22 Microtron for Radiotherapy (방사선 치료용 MM-22 마이크로트론의 설계 특징과 동작 특성)

  • Bak, Joo-Shik;Lee, Dong-Hun
    • Nuclear Engineering and Technology
    • /
    • v.22 no.4
    • /
    • pp.380-388
    • /
    • 1990
  • The MM-22 medical microtron at Korea Cancer Center Hospital is now operational for high energy electron and photon therapy, This microtron is designed to produce 5.3-22.5 MeV electron beams and deliver these to the treatment head through beam transport system with an intensity and stability suitable for cancer treatment. The availability of high quality radiation modalities from the MM-22 shows new possibilities in the treatment of deep seated tumours. Principle of operation, system structures and operating characteristics of the MM-22 are described in this paper.

  • PDF

A Study on Photon Dosimetry System with Diode Defectors (다이오드를 이용한 광자선 선량측정에 관한 연구)

  • Lee, D.H.;Kang, J.K.;Jang, Y.G.;Jee, Y.H.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.148-151
    • /
    • 1992
  • There is a definite requirement to continuously monitor the operating characteristics of radiation therapy machines. It is advisable to monitor the symmetry, flatness, and energy stability of x-ray beams. The semiconductor system was developed using commercially available rectifier diode for th assessment of quality assurance In radiation therapy, which is capable of the above measurements. The beam characteristics of 6MV, 10MV and 21MV photon of Microtron electron accelerator were measured using seven-diodes as detectors and the results were compared with that of using a film results dosimetry with a X-Y plotter. The seven-diode detetor is versatile enough to be used for checking beam profile, flatness, symmetry and energy.

  • PDF

Output Characteristics of Compact Far Infrared Free Electron Laser driven by a Conventional Microtron (마이크로트론을 이용한 소형 원적외선 자유전자레이저에서의 발진 특성)

  • ;;;;;;Gregory Kazakevich
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.02a
    • /
    • pp.48-49
    • /
    • 2000
  • 한국원자력연구소에서는 가속기의 직경이 70 cm이고, 마그네트론 고주파 발생장치를 사용하는 소형 마이크로트론을 이용한 원적외선 자유전자레이저를 개발하였다$^{(1)}$ . 발진 파장은 100 - 200 $mu extrm{m}$ 영역이며, 첨두 출력은 약 1 - 10 kW이다. 본 연구에서는 개발된 원적외선 자유전자레이저의 시스템 개요와 출력 특성에 관하여 살펴보았다. 최근, 반도체와 물성의 분광학연구, 생명공학연구, 광화학 반응연구, 환경감시 기술개발, 인체영상, 군사용 감시기술 개발 등의 분야에서 새로운 연구와 첨단기술개발에 필요한 원적외선 광원의 요구가 점차 높아지고 있다. 이러한 요구에 부응하기 위하여 원적외선 영역의 다양한 광원 개발이 이루어지고 있으며, 특히, 테라헤르쯔 반도체 소자를 개발하기 위한 노력이 국내외에서 활발히 이루어지고 있다. 그러나, 아직까지는 이러한 광원의 출력이 mW 이하이고, 분광특성이 나빠서 실제응용에 많은 제한이 있다. (중략)

  • PDF

A Study on Characteristics of Diode Detecter for Verification of Radiation Therapy (방사선 치료위치 검증을 위한 다이오드 검출기의 특성에 관한 연구)

  • 이동훈;김윤종;지영훈;이동한;홍승홍
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.106-109
    • /
    • 2000
  • The diode characteristics for therapy radiation sensor have been studied by irradiating therapy radiation from the MM22 microtron accelerator. Signal processing has been performed in the pulse mode which can process the signal fast. We have designed integrator, peak detector and synchronization circuit to detect diode signal in the pulse mode for implementation of portal image. We also read the diode signal by A/D board and displayed the peak value with LabView program. Because the quality of portal image obtained by film in the case of therapy radiation is much worse than that of diagnostic film, Digital radiography system by rectifier diode detector was suggested for portal Image.

  • PDF

The Implementation of A Therapy Radiation Dose Measurement System Using A Microcomputer (마이크로컴퓨터를 이용한 치료방사선 선량측정 시스템의 구현)

  • Lee, D.H.;Kwon, O.S.;Hong, J.P.;Chae, C.S.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.15-17
    • /
    • 1996
  • In this paper, the therapy radiation dose measurement system has been implemented by using a microcomputer after radiation was irradiated on diodes from the MM22 microtron accelerator. We have displayed 7-channel diode output values on the LCD after processing those in the 80196 MCU(Micro Computer Unit). Signal processing has been performed in the pulse mode because we can process the signal fast and use it to perform portal image by increasing a number of diode channels in the future. In order to verify the microcomputer based radiation measurement system of diodes, diode output values were compared with that of semiconductor.

  • PDF

A Study on the Characteristics of Therapy Radiation Detector with Diode (다이오드를 이용한 치료방사선 검출기의 특성에 관한 연구)

  • 이동훈;지영훈
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.129-138
    • /
    • 1995
  • High-energy and high-dose X-ray and electron beam have been used in radiation therapy after developing particle accelerators. It is recommended to irradiate patients exect real dose for improving therapy effectiveness by International Committee on Radiation Units and Measurement. The radiation detector for daily beam checks of medical accelerators is described. Using thirteen silicon diodes, we have designed the diode detector providing information about calibration, beam symmetry, flatness, stability variation according to radiation damage, time and general quality assurance for both photon and eletron beams. we also compared these measurement values with those of using ionization chamber, film and semiconductor dosimeter.

  • PDF