• 제목/요약/키워드: Microscopic observation

검색결과 708건 처리시간 0.024초

Molecular epidemiological survey of pathogenic trypanosomes in naturally infected cattle in northern Côte d'ivoire

  • Jean-Yves Ekra;Edouard K. N'Goran;Leonard E.G. Mboera;Biego Guillaume Gragnon;Koco Rita Nadege Assovie;Eliakunda Michael Mafie
    • Parasites, Hosts and Diseases
    • /
    • 제61권2호
    • /
    • pp.127-137
    • /
    • 2023
  • Bovine trypanosomiasis is a significant health concern for livestock intensification in Côte d'Ivoire. This study aimed to determine the prevalence and distribution of pathogenic trypanosomes and identify the most infected cattle breed in northern Côte d'Ivoire. We examined 700 cattle and found that polymerase chain reaction (PCR) was more sensitive (12.3%) than microscopic observation (5.6%). Among the trypanosome species detected in naturally infected cattle, Trypanosoma vivax was 7.3%, Trypanosoma simiae tsavo was 6.7%, and Trypanosoma congolense was 0.4%. The overall prevalence of trypanosome infection in all cattle breeds was 12.3%, while the prevalence in individual breeds was 14.8%, 7.3%, 10.6%, and 12.3% for N'Dama, Baoule, Zebu, and Mere breed, respectively. The infected animals had low packed cell volume, influencing the prevalence. Our findings indicate that bovine trypanosomes are prevalent in Côte d'Ivoire, and their prevalence varies by region and breed. These pathogens include T. vivax, T. simiae tsavo, and T. congolense.

Quality Improvement to Prevent Shifting Error of Tracked Vehicles (궤도차량 변속오류 예방을 위한 품질개선)

  • Yun, Sunghyun;Baek, Hyun Moo;Park, Dong Min;Oh, Dong-Kyo
    • Journal of Korean Society for Quality Management
    • /
    • 제51권2호
    • /
    • pp.297-313
    • /
    • 2023
  • Purpose: The purpose of this study is to investigate the causes of shifting errors reported in military tracked vehicles and to improve related quality to prevent recurrence. Methods: A systematic disassembly and inspection of the transmission is carried out and an experimental simulation is conducted to reproduce the shifting error phenomenon. Electrical characteristic tests are subsequently performed and microscopic observation is also carried out on the disassembled connector parts such as pins and fractured surfaces. Results: Oil contamination and swelling deformation are observed in the connector to the vehicle due to oil leakage of its counterpart connector to the transmission. This causes electrical contact failure between both connectors in the fastened state, and it is found that shifting error of the tracked vehicle could occur subsequently. To prevent the recurrence of this phenomenon, comprehensive quality improvement is conducted including product improvement of the wiring harness assembly and strengthening activities for quality control and preventive maintenance. Conclusion: This study is expected to be helpful as a prior case study for cause analysis and recurrence prevention in the event of similar cases in the future.

An efficient microscopic technique for aleurone observation with an entire kernel cross-section in maize (Zea mays L.)

  • Jae-Hong Kim;Ji Won Kim;Gibum Yi
    • Korean Journal of Agricultural Science
    • /
    • 제50권4호
    • /
    • pp.645-652
    • /
    • 2023
  • The aleurone layer in maize is crucial as it contains essential nutrients such as minerals, vitamins, and high-quality proteins. While most of the maize varieties are known to possess a single aleurone layer, several multi-aleurone layer mutants and landraces have been suggested for hierarchical genetic control of aleurone development. Conventional microscopy analysis often involves using immature seeds or sampling only a portion of the kernel sample, and whole kernel section analysis using a microtome is technically difficult and time-consuming. Additionally, the larger size of maize kernels posed challenges for comprehensive cross-sectional analysis compared to other cereal crops. Consequently, this study aimed to develop an efficient method to comprehensively understand the aleurone layer characteristics of the entire cross-section in maize. Through observations of diverse maize genetic resources, we confirmed irregular aleurone layer patterns in those with multiple aleurone layers, and we discovered a landrace having multiple aleurone layers. By selectively identifying genetic resources with multiple aleurone layers, this method may contribute to efficient breeding processes in maize.

Microscopical observation and randomly amplified polymorphic DNA (RAPD) analysis of artificially cultivated Ganoderma applanatum

  • Woo-Sik Jo;Young-Hyun Rew;Seung-Chun Park
    • Journal of Mushroom
    • /
    • 제22권2호
    • /
    • pp.48-52
    • /
    • 2024
  • This study investigated the microscopic characteristics and genetic relationships of Ganoderma applanatum fruiting bodies. Basidiospores were brown, ellipsoid, and had one or two large vacuoles and a double wall. The surface of basidiospores was smooth or wrinkled and most had numerous small and shallow holes. The length and width of basidiospores of Ganoderma applanatum isolates GBGA-01, GBGA-02, ASI 50167, ASI 52821, ASI 52822, ASI 52823, and ASI 53399 were on average 7.6×4.8 ㎛, 7.9×4.6 ㎛, 7.7×4.9 ㎛, 8.2×5.3 ㎛, 7.7×5.0 ㎛, 8.0×4.9 ㎛, and 7.9×4.9 mm, respectively. In contrast, the basidiospores of Ganoderma lucidum isolate ASI 7125 were 7.7×5.2 ㎛. Using the universal ITS1/ITS4 primer set, the ITS region of the isolates were amplified and sequenced. The ITS sequences were very closely related to G. applantum isolate GBGA-01, GBGA-02, ASI 50167, ASI 52821, ASI 52822, ASI 52823 and ASI 53399, but were not the same species. Whereas, G. lucidum isolate ASI 7125 belongs to different group.

Microscopic Observation of Pellets Fabricated with Torrefied Larch and Tulip Tree Chips and Effect of Binders on the Durability of the Pellets (반탄화 낙엽송 및 백합나무 칩으로 제조한 펠릿의 현미경 관찰과 펠릿의 내구성에 대한 바인더의 영향)

  • Park, Dae-Hak;Ahn, Byung Jun;Kim, Sang Tae;Lee, Jae-Won;Han, Gyu-Seong;Yang, In
    • Korean Chemical Engineering Research
    • /
    • 제53권2호
    • /
    • pp.224-230
    • /
    • 2015
  • This study was conducted to investigate the effects of several variables on the durability of wood pellets fabricated with torrefied larch (LAR) and tulip tree (TUT) chips. Microscopic observation by scanning electron microscope-energy dispersive X-ray spectrometer was also performed to identify the surface of the wood pellets visually. In addition, torrefied-LAR and TUT pellets were fabricated with the addition of moisture, lignin, starch and protein as binders, and durabilities of the pellets were analyzed statistically. Durabilities of torrefied-LAR and TUT pellets were lower than one of non-torrefied-LAR and TUT pellets. Durabilities of both pellets fabricated with the wood chips, which were torrefied with $230^{\circ}C$ and 30 min, were the highest among all torrefaction conditions used in this study. From the microscopic observations, lignin was distributed broadly on the surface of non-torrefied wood pellets, whereas congregated partially on the surface of torrefied wood pellets. Durability of LAR pellets increased with the addition of moisture, but that of TUT pellets was reduced. Addition of binders contributed to increase the durability of LAR and TUT pellets. As a binder, lignin and protein were more effective than starch for improving the durability. In conclusion, mild torrefaction treatment, such as $230^{\circ}C$ and 30 min, might be an optimal condition to minimize the durability reduction of the LAR and TUT pellets. In addition, when torrefied woody materials with high and low specific gravities are used as a raw material for the production of durable wood pellets, it might be required to adjust moisture content and torrefaction conditions of woody materials, respectively.

Histological Comparison of Vascular Grafts in a Pig to Goat Xenotransplantation Model (돼지-염소 이종이식모델에서 냉동 및 무세포화 혈관이식편의 조직학적 비교분석)

  • Yang Ji-Hyuk;Sung Ki-Ick;Kim Won-Geon
    • Journal of Chest Surgery
    • /
    • 제39권6호
    • /
    • pp.427-433
    • /
    • 2006
  • Background: Current vascular prostheses are considered still inadequate for reconstruction of small-diameter vessels. To evaluate the potential use of xenograft vessels as small diameter arterial grafts, we implanted porcine vessels in goats. The grafts were treated with two different processes, freezing and acellularization, before implantation, and gross inspection as well as microscopic examination followed after a predetermined period. Material and Method: Bilateral porcine carotid arteries were harvested and immediately stored at $-70^{\circ}C$ within tissue preservation solution. One of them was designated as frozen xenograft vessel. The other one was put on acellularization process using NaCl-SDS solution and stored frozen until further use. Grafts were implanted in the place of carotid arteries of the same goat. The grafts have remained implanted for 1, 3, and 6 months in three animals, respectively. Periodic ultrasonographic examinations were performed during the observation period. After explantation, the grafts were analyzed grossly and histologically under light microscope. Result: All animals survived the experimental procedure without problems. Ultrasonographic examinations showed excellent patency of all the grafts during the observation period. Gross examination revealed nonthrombotic, patent lumens with smooth surfaces. Microscopic examinations of the explanted grafts showed cellular reconstruction at the 6-month stage in both grafts. Although more inflammatory responses were observed in the early phase of frozen xenografts, there was no evidence of significant rejection. Conclusion: These findings suggest that porcine xenograft vessels, regardless of pre-implantation processes of acelluarization or freezing, can be acceptably implanted in goats, although short duration of observation in a small number of animals may limit this study.

Studios on Intestinal Trematodes in Korea X. Scanning Electron Microscopic Observation on the Tegument of Fibricola seoulensis (한국의 간흡충에 관한 연구 X. Fibricola seoulensis 표피의 전자현미경적 관찰)

  • 서병설;이순향
    • Parasites, Hosts and Diseases
    • /
    • 제22권1호
    • /
    • pp.21-29
    • /
    • 1984
  • A scanning eletron microscopic study was performed to observe the tegumental surface of adult Fibricola seoulensis. The adult worms were collected from the small intestine of mice 5 days to 3 weeks after experimental infection with the metacercariae. The metacercariae were obtained from the viscera of the snakes, Matrix tigrina lateralis, by artificial digestion technique. The results were as follows: 1. The tegument of anterior body was covered with cobblestone-like cytoplasmic processes and that of posterior body showed finger-like processes. The posterior body had 4-5 large transverse wrinklings which formed many discontinued shallow rugae. 2. The entire surface of anterior body was regularly arranged with the spines of which tips diverged into 3 to 4 points. They were densely packed in anterior mid-median portion of dorsal surface where appeared a few spines indented upto 5 points. Farther laterally and posteriorly from this portion, the pointed spines were more sparse and became single tipped and extended to anterior one-third of posterior body, 3. The posterior surface of oral sucker was armed with 50-60 spines having 2-3 tips and ventral sucker also covered with such spines. On anteriormost dorsal surface arranged 60-70 spade-shaped spines. The tribocytic organ was armed with many stout recurved pile-like spines arranged radially. 4. There were 3 types of sensory papillae. The ciliated knob-like (Type I) papillae were almost bilaterally symmetrical in ventral and dorsal surfaces of anterior body, and abundant especially aroundbases of oral and ventral suckers, tribocytic organ, and in lateral margins of anterior body. About 24 non-ciliated round swellings (Type II) were observed around each lip of oral and ventral suckers. The plate-like elevated papilla without cilium (Type III) was found to distribute only in posterior body. These 3 types of papillae seem to be tangoreceptive and/or rheoreceptive in function when their morphology and distributions are considered.

  • PDF

Material Characteristics and Clay Source Interpretation of the Ancient Ceramic Artifacts from the Wonsinheungdong Site in Daejeon, Korea (대전 원신흥동 유적 출토 고대 세라믹 유물의 재료학적 특성과 원료의 산지해석)

  • Kim, Ran-Hee;Jung, Hae-Sun;Jung, Sang-Hoon;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • 제27권2호
    • /
    • pp.163-179
    • /
    • 2011
  • This study was to identify the material characteristics and provenance of the crucibles, potteries and roof tiles from the Wonsinheungdong site in Daejeon, Korea. Similar mineral composition of each samples showed by microscopic observation and X-ray diffraction analysis. However, wall thickness and mineral characterization of each ceramic artifacts are quite different. The pottery is characterized by thin wall with 0.5 to 0.7 cm and fine grained clay matrix. While the crucible and roof tile has thick wall with 1.3 to 2.5 cm, poorly sorted texture of many quarz, orthoclase and plagioclase whithin ceramic fabric. And large elonagated voids formed by hydrocarbone of straw during the firing and loose matrix obseved in crucible. All ceramic samples and ground soil of the site show similar mineralogical characteristics geochemical behavior and clay-mineralization degree. This indicates making that the soil is probable to be a raw material of all ceramic from the Wonsinheungdong site. Also, firing temperature of most ceramic artifacts are estimated as 850 of all ceramic from the Wonsinheungdong site. Also, firing temperature of most ceramic artifacts are estimated as 850 to $950^{\circ}C$ but hardest pottery fired high temperature between 1,050 to $1,150^{\circ}C$. The vitreous molten materials interpreted in slag included segregation of copper and tin. But it can not exclude the possibility that the glass molten material because observed reddish and greenish vitreous fine structure under microscopic.

STUDY OF PATENCY RATE IN VARIABLE MICROVASCULAR ANASTOMOSIS (다양한 방법으로 적용한 미세혈관문합술간의 개존율연구)

  • Kim, Uk-Kyu;Kim, Yong-Deok;Byun, June-Ho;Shin, Sang-Hun;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제29권5호
    • /
    • pp.349-357
    • /
    • 2003
  • Several microvascular anastomotic techniques have been described with methodical effectiveness, patency rates, healing state of microscopic findings. This experimental study presents the comparison of three types of arterial microvascular anastomotic techniques: end-to-end(ETE) anastomosis, end-in-end(EIE) anastomosis, and continuous technique. Sixty male Sprague-Dawley rats, 60 femoral arteries were used for this study. Twenty rats per each technique were used and sacrificed at post-operation 1 day, 3 days, a week, 2 weeks for scanning electromicroscopic findings. The patency was monitored by miniDoppler throughout total experimental periods. The anastomotic time on each method was measured to compare the technical effectiveness. The final results were as follows: 1. The anastomotic time for the end-in-end technique was significantly shorter than another techniques. The average time for each technique was measured as 15 minutes on EIE technique, 20 minutes on continuous technique and 25 minutes on ETE technique. 2. The patency rate for the end-in-end technique at 2 weeks also was superior to another techniques. The patency rate for each technique was demonstrated as 90 % on EIE technique, 85 % on ETE technique and 80 % on continuous technique. 3. The scanning electromicroscopic findings on healing condition of vessel endothelium during the observation period showed that the end results of EIE technique, ETE technique and continuous technique in sequence were good. The end-in-end technique proved to be the superior with regard to anastomotic time and patency rate when compared to end-to-end technuqe, so EIE techniqe might be well available for the case of large discrepancy of vessel size. The patency rate, microscopic healing findings in continuous technique were seen as the lowest level among the three anastomotic techniques, therefore the application of continuous technique was recommended only on the inevitable case.

Scanning Electron Microscopic Study of the Effect of Tetracycline-HCl on the Change of Implant Surface Microstructure according to Application Time (염산테트라싸이클린의 적용시간에 따른 임플란트 표면변화에 관한 주사전자현미경적 연구)

  • Kim, Woo-Young;Lee, Man-Sup;Park, Joon-Bong;Herr, Yeek
    • Journal of Periodontal and Implant Science
    • /
    • 제32권3호
    • /
    • pp.523-537
    • /
    • 2002
  • The present study was performed to evaluate the effect of tetracycline - HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and $TiO_2blasted$ surface were used. Implant surface was rubbed with 5Omg/ml tetracycline - HCl solution for ${\frac}{1}{2}$ min., 1 min., $1{\frac}{1}{2}$ min., 2 min., and 3min. respectively in the test group and with no conditioning in the control group. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. In the pure titanium machined surfaces, the control specimen showed a more or less rough machined surface composed of alternating positive and negative lines corresponding to grooves and ridges. After treatment, machining line was more pronounced for the control specimens. but in general, test specimens were similar to control. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. subsequently, the acid-etching process crated the micro roughness, which thus was superimposed on the macro roughness. 3. In the SLA surfaces, irrespective of the application time of 50mg/ml tetracycline-HCl solution, in general, test specimens were similar to control. 4. In the $TiO_2blasted$ surfaces the control specimen showed the rough surface with small pits. The irregularity of the $TiO_2blasted$ surfaces with 50mg/ml tetracycline-HCl solution was lessened and the flattened areas were wider relative to the application time of tetracycline - HCl solution. In conclusion, pure titanium machined surfaces and SLA surfaces weren't changed irrespective of the application time of tetracycline-HCl solution. And the $TiO_2blasted$ surfaces conditioned with tetracycline - HCl solution began to be changed from $1{\frac}{1}{2}$ min. This results are expected to be applied to the regenerative procedures for peri-implantitis treatment.