• Title/Summary/Keyword: Microprobes

Search Result 4, Processing Time 0.008 seconds

Highly Productive Process Technologies of Cantilever-type Microprobe Arrays for Wafer Level Chip Testing

  • Lim, Jae-Hwan;Ryu, Jee-Youl;Choi, Woo-Chang
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.2
    • /
    • pp.63-66
    • /
    • 2013
  • This paper describes the highly productive process technologies of microprobe arrays, which were used for a probe card to test a Dynamic Random Access Memory (DRAM) chip with fine pitch pads. Cantilever-type microprobe arrays were fabricated using conventional micro-electro-mechanical system (MEMS) process technologies. Bonding material, gold-tin (Au-Sn) paste, was used to bond the Ni-Co alloy microprobes to the ceramic space transformer. The electrical and mechanical characteristics of a probe card with fabricated microprobes were measured by a conventional probe card tester. A probe card assembled with the fabricated microprobes showed good x-y alignment and planarity errors within ${\pm}5{\mu}m$ and ${\pm}10{\mu}m$, respectively. In addition, the average leakage current and contact resistance were approximately 1.04 nA and 0.054 ohm, respectively. The proposed highly productive microprobes can be applied to a MEMS probe card, to test a DRAM chip with fine pitch pads.

Fabrication and Its Biomedical Application of the pH-ISFET Microprobe (pH-ISFET 마이크로프로브의 製作과 그 生醫學的 應用)

  • Lee, Kwang-Man;Sohn, Byung-Ki
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.11
    • /
    • pp.1335-1341
    • /
    • 1988
  • A pH-ISEFET microprobe for in vivo measurements has been fabricated by combining ISFET (SL-IIS) chip and capillary thin film reference electrode. A two-step TCE oxidation for the gate oxide layer and multilayer encapsulation using silicone rubber and epoxy were specially used for the improvement of the stability and temperature dependence of the ISFET's. The measured sensitivit, response time and temperature dependence of the pH-ISFET microprobes are 50 mV/pH, less than one second, and - 0.01 pH/$^{\circ}$ , respectively. By operating continuously more than 40 days, a long term stability of 0.016 pH/day is obtained. The result of pH monitoring of femoral arterial blood in a rabbit is fairly good agreement with the value of blood gas analysis.

  • PDF

In fluency on Refraction and Phase Cancellation Effect in Ultrasonic CT and its Correction (초음파 CT에서의 굴절 및 위상 상쇄 효과의 영향과 그 보정법)

  • 최종수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.6
    • /
    • pp.33-40
    • /
    • 1982
  • Although ultrasonic CT is one of the useful techniques for tissue characterization, the reconstructed images, such as the velocity distribution and attenuation constant distribution, are degraded by reflection and refraction of ultrasonic beam. This paper studied the degradation effects on attenuation images using agar gel phantoms which were developed to evaluate ultrasonic CT. We found that the reconstructed attenuation constants at the center of the phantoms were less than the actual values by 0.6 dB/cm when phantom velocity differs by 25 m/s from surrounding saline. We also studied a correction method for refraction and phase cancellation effects, where the correction was made using the maximum value in the received subdata, as obtained by sub-arraying microprobes located at each sampling point. Using this method, we could obtain an improvement in the reconstructed image by the correction on the attenuation effect.

  • PDF

Current-in-plane Tunneling Measurement through Patterned Contacts on Top Surfaces of Magnetic Tunnel Junctions

  • Lee, Ching-Ming;Ye, Lin-Xiu;Lee, Jia-Mou;Lin, Yu-Cyun;Huang, Chao-Yuan;Wu, J.C.;Tsunoda, Masakiyo;Takahashi, Migaku;Wu, Te-Ho
    • Journal of Magnetics
    • /
    • v.16 no.2
    • /
    • pp.169-172
    • /
    • 2011
  • This study reports an alternative method for measuring the magnetoresistance of unpatterned magnetic tunnel junctions similar to the current-in-plane tunneling (CIPT) method. Instead of using microprobes, a series of point contacts with different spacings are coated on the top surface of the junctions and R-H loops at various spacings are then measured by the usual four-point probe method. The values of magnetoresistance and resistance-area products can be obtained by fitting the measured data to the CIPT theoretical model. The test results of two types of junctions were highly similar to those obtained from standard CIPT tools. The proposed method may help to accelerate the process for evaluating the quality of magnetic tunnel junctions when commercial CIPT tools are not accessible.