• 제목/요약/키워드: Micropillars

검색결과 8건 처리시간 0.01초

A Bio-Inspired Cell-Microsystem to Manipulate and Detect Living Cells

  • Lim, Jung-Min;Byun, Sang-Won;Park, Tai-Hyun;Seo, Jong-Mo;Yoo, Young-Suk;Hum Chung;Dong-il
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권4호
    • /
    • pp.160-164
    • /
    • 2004
  • In this study, we demonstrate for the first time a bio-inspired Cell-Microsystem to manipulate and detect living cells. Cultured retinal pigment epithelial cell line (ARPE-19) was directed to grow in a pre-defined Cell-Microsystem. The three-dimensional micropillars of 5 ${\mu}{\textrm}{m}$ in height and diameter of the Cell-Microsystem were fabricated. Inhibited DNA synthesis and transformed cell morphology were observed throughout the culture period. The demonstration of manipulating and detecting living cells by the surface topography is a new approach, and it will be very useful for the future design of cell-based biosensors and bioactuators.

마이크로 기둥 구조가 있는 친수성/소수성 표면에서의 겉보기 접촉 각에 대한 연구 (Apparent Contact Angle on the Hydrophilic/Hydrophobic Surfaces with Micro-pillars)

  • 유동인;도승우;곽호재;안호선;김무환;박현선
    • 한국정밀공학회지
    • /
    • 제31권2호
    • /
    • pp.171-178
    • /
    • 2014
  • In this study, the apparent contact angle on the hydrophilic/hydrophobic surfaces with micropillars was studied. The previous researches showed that the Wenzel equation and the Cassie-Baxter equation were thermodynamically derived for the rough hydrophilic/hydrophobic surfaces and generally referenced on the field of wetting phenomena. For the verification of both equations, the apparent contact angle on the hydrophilic/hydrophobic surfaces with micro-pillars was measured. In the comparison between the measured and estimated apparent contact angles with the equations, the differences between the apparent contact angles were analyzed. Conclusively, the available range and limitation of theoretical equations were investigated and further researches about the apparent contact angle on the rough surfaces were proposed.

교차 전기영동법을 이용한 극소형 DNA 추출기 (A DNA Microextractor Using Crossed Field Electrophoresis)

  • 이소연;서경선;조영호
    • 대한기계학회논문집A
    • /
    • 제28권8호
    • /
    • pp.1135-1139
    • /
    • 2004
  • This paper presents a microextractor for the separation of DNA molecules by their sizes. The DNA microextractor immobilizes the DNA molecules of specific size in the micropillar array by adjusting the period of the crossed electric field, thus providing a starting-point independent target DNA extraction method without separation process monitoring. The DNA microextractor has been fabricated by a three-mask micromachining process. The velocity of three different DNA molecules has been measured at the electric field of E=5V/0.8cm in the fabricated DNA microextractor, resulting in the reorientation times of $4.80{\pm}0.44sec,\;7.12{\pm}0.75sec$, and $9.88{\pm}0.30sec$ for ${\lambda}$ DNA, micrococcus DNA, and T4 DNA, respectively. T4 DNA is trapped in the micropillar array when the crossed electric field of 5V/0.8cm is applied alternately at a 10 second time interval. The present DNA microextractor filters the DNA in a specific size range by adjusting the magnitude and/or the period of the crossed electric field applied in the micropillar array.

Development of the Microfluidic Device to Regulate Shear Stress Gradients

  • Kim, Tae Hyeon;Lee, Jong Min;Ahrberg, Christian D.;Chung, Bong Geun
    • BioChip Journal
    • /
    • 제12권4호
    • /
    • pp.294-303
    • /
    • 2018
  • Shear stress occurs in flowing liquids, especially at the interface of a flowing liquid and a stationary solid phase. Thus, it occurs inside the artery system of the human body, where it is responsible for a number of biological functions. The shear stress level generally remains less than $70dyne/cm^2$ in the whole circulatory system, but in the stenotic arteries, which are constricted by 95%, a shear stress greater than $1,000dyne/cm^2$ can be reached. Methods of researching the effects of shear stress on cells are of large interest to understand these processes. Here, we show the development of a microfluidic device for generating shear stress gradients. The performance of the shear stress gradient generator was theoretically simulated prior to experiments. Through simple manipulations of the liquid flow, the shape and magnitude of the shear stress gradients can be manipulated. Our microfluidic device consisted of five portions divided by arrays of micropillars. The generated shear stress gradient has five distinct levels at 8.38, 6.55, 4.42, 2.97, and $2.24dyne/cm^2$. Thereafter, an application of the microfluidic device was demonstrated testing the effect of shear stress on human umbilical vein endothelial cells.

Depth-dependent EBIC microscopy of radial-junction Si micropillar arrays

  • Kaden M. Powell;Heayoung P. Yoon
    • Applied Microscopy
    • /
    • 제50권
    • /
    • pp.17.1-17.9
    • /
    • 2020
  • Recent advances in fabrication have enabled radial-junction architectures for cost-effective and high-performance optoelectronic devices. Unlike a planar PN junction, a radial-junction geometry maximizes the optical interaction in the three-dimensional (3D) structures, while effectively extracting the generated carriers via the conformal PN junction. In this paper, we report characterizations of radial PN junctions that consist of p-type Si micropillars created by deep reactive-ion etching (DRIE) and an n-type layer formed by phosphorus gas diffusion. We use electron-beam induced current (EBIC) microscopy to access the 3D junction profile from the sidewall of the pillars. Our EBIC images reveal uniform PN junctions conformally constructed on the 3D pillar array. Based on Monte-Carlo simulations and EBIC modeling, we estimate local carrier separation/collection efficiency that reflects the quality of the PN junction. We find the EBIC efficiency of the pillar array increases with the incident electron beam energy, consistent with the EBIC behaviors observed in a high-quality planar PN junction. The magnitude of the EBIC efficiency of our pillar array is about 70% at 10 kV, slightly lower than that of the planar device (≈ 81%). We suggest that this reduction could be attributed to the unpassivated pillar surface and the unintended recombination centers in the pillar cores introduced during the DRIE processes. Our results support that the depth-dependent EBIC approach is ideally suitable for evaluating PN junctions formed on micro/nanostructured semiconductors with various geometry.

미세유체의 효율적인 액적 합류를 위한 정체현상 조절 (Stagnation of Droplet for Efficient Merging in Microfluidic System)

  • 진시형;김종민;장성찬;노영무;이창수
    • Korean Chemical Engineering Research
    • /
    • 제52권1호
    • /
    • pp.106-112
    • /
    • 2014
  • 본 연구에서는 미세액적을 효과적으로 합류시키기 위하여 미세기둥 구조들에 따른 영향 및 정체 현상 조절에 관한 연구를 수행하였다. 최적의 미세액적 합류조건을 찾기 위하여 매우 정교하게 조절이 가능한 미세 밸브를 접목하였다. 수용성 미세액적은 연속상으로 0.5 wt% Span 80이 함유된 미네랄 오일을 사용하였다. 합류과정은 미세유체 칩 내부에 위치한 미세기둥의 구조와 배치를 통해 액적 주위의 압력과 액적 내부의 라플라스 압력의 차이를 조정하여 수행된다. 마지막으로 최적의 합류 구조를 지닌 미세유체시스템에서 효소 생화학반응 실험을 수행함으로써 본 장치가 생물학 및 생화학 실험을 수행하는 유용한 도구로서 사용될 수 있음을 입증하였다.

Characterization of Nanopores on Micropillars Pt Electrodes for Non-Enzymatic Electrochemical Sensor Applications

  • Park, Dae-Joon;Lee, Yi-Jae;Park, Jae-Yeong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제7권3호
    • /
    • pp.161-165
    • /
    • 2007
  • In this paper, mesoporous Pt on micro pillars Pt electrode is newly designed, fabricated, and characterized on silicon substrate for non-enzymatic electrochemical sensor micro-chip integrated with CMOS readout circuitry. The fabricated micro/nano Pt electrode has cylindrical hexangular arrayed nano Pt pores with a diameter of 3.2 nm which is formed on top of the micro pillars Pt electrode with approximately $6{\mu}m$ in diameter, $6{\mu}m$ in space, and $50{\mu}m$ in height. The measured current responses of the fabricated plane Pt, mesoporous Pt, and mesoporous Pt on the micro pillar Pt electrodes are approximately $9.9nA/mm^2,\;6.72{\mu}A/mm^2,\;and\;7.67{\mu}A/mm^2$ in 10mM glucose solution with 0.1M phosphate buffered saline (PBS) solution, respectively. In addition, the measured current responses of the fabricated plane Pt, mesoporous Pt, and mesoporous Pt on the micro pillar Pt electrodes are approximately $0.15{\mu}A/mm^2,\;0.56{\mu}A/mm^2,\;and\;0.74{\mu}A/mm^2$ in 0.1mM ascorbic acid (AA) solution with 0.1M phosphate buffered saline (PBS) solution, respectively. This experimental results show that the proposed micro/nano Pt electrode is highly sensitive and promising for CMOS integrated non-enzymatic electrochemical sensor applications. Since the micro-pillar Pt electrode can also be utilized with a micro-fluidic mixer in the sensor chip, the sensor chip can be much smaller, cheaper, and easier to be fabricated.