• 제목/요약/키워드: MicroCT

검색결과 426건 처리시간 0.025초

Micro-computed tomography analysis of changes in the periodontal ligament and alveolar bone proper induced by occlusal hypofunction of rat molars

  • Shimizu, Yasuhiro;Hosomichi, Jun;Nakamura, Saeko;Ono, Takashi
    • 대한치과교정학회지
    • /
    • 제44권5호
    • /
    • pp.263-267
    • /
    • 2014
  • Objective: To three-dimensionally elucidate the effects of occlusal hypofunction on the periodontal ligament and alveolar bone proper of rat molars by micro-computed tomography (micro-CT). Methods: Occlusal function in the molar area was restricted by attaching an anterior bite plate on the maxillary incisors and a metal cap on the mandibular incisors of 5-week-old male Wistar rats for 1 week. The periodontal ligament space and alveolar bone proper around roots of the mandibular first molar were assessed by histology and micro-CT. Results: The periodontal ligament space was narrower and the alveolar bone proper was sparser and less continuous in the hypofunction group than in the control group. Further, both the volume of the periodontal ligament and the volumetric ratio of the alveolar bone proper to the total tissue in the region of interest were significantly lower in the hypofunction group (p < 0.05). Conclusions: Occlusal hypofunction induces atrophic changes in the periodontal ligament and alveolar bone proper of rat molars.

A micro-computed tomographic study of remaining filling materials of two bioceramic sealers and epoxy resin sealer after retreatment

  • Kim, KyungJae;Kim, Da Vin;Kim, Sin-Young;Yang, SungEun
    • Restorative Dentistry and Endodontics
    • /
    • 제44권2호
    • /
    • pp.18.1-18.9
    • /
    • 2019
  • Objective: This study evaluated the presence of residual root canal filling material after retreatment using micro-computed tomography (micro-CT). Materials and Methods: Extracted human teeth (single- and double-rooted, n = 21/each; C-shaped, n = 15) were prepared with ProFile and randomly assigned to three subgroups for obturation with gutta-percha and three different sealers (EndoSeal MTA, EndoSequence BC sealer, and AH Plus). After 10 days, the filling material was removed and the root canals were instrumented one size up from the previous master apical file size. The teeth were scanned using micro-CT before and after retreatment. The percentage of remaining filling material after retreatment was calculated at the coronal, middle, and apical thirds. Data were analyzed using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni post hoc correction. Results: The tested sealers showed no significant differences in the percentage of remaining filling material in single- and double-rooted teeth, although EndoSeal MTA showed the highest value in C-shaped roots (p < 0.05). The percentage of remaining filling material of AH Plus and EndoSeal MTA was significantly higher in C-shaped roots than in single- or double-roots (p < 0.05), while that of BC sealer was similar across all root types. EndoSeal MTA showed the highest values at the apical thirds of single- and double-roots (p < 0.05); otherwise, no significant differences were observed among the coronal, middle, and apical thirds. Conclusions: Within the limitations of this study, a large amount of EndoSeal MTA remained after retreatment, especially in C-shaped root canals.

Morphotypes of the apical constriction of maxillary molars: a micro-computed tomographic evaluation

  • Jeffrey Wen-Wei Chang;Kuzhanchinathan Manigandan;Lakshman Samaranayake;Chellapandian NandhaKumar;Pazhamalai AdhityaVasun;Johny Diji;Angambakkam Rajasekharan PradeepKumar
    • Restorative Dentistry and Endodontics
    • /
    • 제47권2호
    • /
    • pp.19.1-19.15
    • /
    • 2022
  • Objectives: The aim of this study was to evaluate and compare the apical constriction (AC) and apical canal morphology of maxillary first and second molars, using micro-computed tomography (micro-CT). Materials and Methods: The anatomical features of 313 root canals from 41 maxillary first molars and 57 maxillary second molars of patients with known age and sex were evaluated using micro-CT, with a resolution of 26.7 ㎛. The factors evaluated were the presence or absence of AC, the morphotypes, bucco-lingual dimension, mesio-distal dimension, and the profile (shape) of AC and the apical root canal. The apical root canal dimensions, location of the apical foramen (AF), AC to AF distance, and presence of accessory canals in the apical 5 mm were also assessed. Descriptive and analytical statistics were used for data evaluation. Results: AC was present in all 313 root canals. Patients' age and sex did not significantly impact either AC or the apical canal dimensions. The most common AC morphotype detected was the traditional (single) constriction (52%), followed by the parallel (29%) morphotype. The mean AC dimensions in maxillary first molars were not significantly different from those in maxillary second molars. Sixty percent of AF were located within 0.5 mm from the anatomic apex. Conclusions: The most common morphotype of AC detected was the traditional constriction. Neither patients' age nor sex had a significant impact on the dimensions of the AC or the apical root canal. The majority of AF (60%) were located within 0.5 mm from the anatomic apex.

인접면 초기 우식 병소의 깊이에 따른 therapeutic sealing의 유효성 평가 (EVALUATION OF THE EFFECTIVENESS OF THERAPEUTIC SEALING ACCORDING TO THE LESION DEPTHS OF PROXIMAL EARLY CARIES)

  • 이금랑;안명기;정태성;김신
    • 대한소아치과학회지
    • /
    • 제36권3호
    • /
    • pp.394-403
    • /
    • 2009
  • 인접면 초기 우식병소에 대하여 레진 접착제를 도포하는 최소 침습적 개념의 therapeutic sealing은 치질 삭제가 불필요하다는 점에서 의미있는 술식으로 인정된다. 그러나 이 방법이 초기 우식병소의 법랑질 내 침투 깊이와 무관하게 여전히 유효할 것인지에 대해 의문이 들어 이번 연구는 그 유효성을 평가해 보기 위해 시도되었다. 인접면에 초기 우식병소를 보이는 발거된 소구치 21개를 대상으로 하고, micro-CT 촬영을 통해 병소의 깊이에 따라 분류하였다. 전체 시편을 병소가 법랑질 외층에 국한된 시편의 표면 절반에 접착제를 도포한 1군과 하지 않은 2군, 병소가 법랑질 내층까지 진행된 시편의 표면 절반에 접착제를 도포한 3군과 하지 않은 4군, 비와동성 초기 병소가 법랑-상아 경계까지 진행된 시편의 표면 절반에 접착제를 도포한 5군과 하지 않은 6군으로 분류하였다. 열순환 후 2주간 인공 우식을 유발하고 분류과정과 동일한 평면을 찾아 micro-CT를 촬영하고 병소의 방사선 밀도 변화를 관찰하여 다음과 같은 결과를 얻었다. 1. 인접면 초기 우식병소의 침투 깊이가 증가할수록 병소 본체의 방사선 밀도는 낮아지는 것이 관찰되었다. 2. 병소의 깊이에 무관하게, 레진 접착제를 도포한 모든 실험군에서 처리하지 않은 대조군에 비하여 인공 우식 처리 전후의 방사선 밀도 변화 가 작게 나타났다(p<0.05). 3. 병소가 법랑-상아 경계에 도달한 5군에서도 레진 접착제를 도포하고 인공 우식 처리시, 실험 전후의 유의한 방사선 밀도 변화가 나타나지 않았다(p<0.05).

  • PDF

마이크로 패턴 성형을 위한 인서트 코어 적용 µ-PIM 표준금형 개발에 관한 연구 (Development of µ-PIM standard mold with exchangable insert core in order to manufacture micro pattern)

  • 박치열;서찬열;김용대
    • Design & Manufacturing
    • /
    • 제11권3호
    • /
    • pp.29-34
    • /
    • 2017
  • Increased demand for parts with micro-pattern structure made of metals, ceramics, and composites in various fields such as medical ultrasonic sensors, CT collimators, and ultra-small actuator parts. Micro powder injection molding (PIM) is a technology for manufacturing micro size, high volume, complex, precision, net-shape components from either metal or ceramic powder. In the present study, a standard mold with a variable insert core capable of producing various micro patterns was investigated. An injection molding test was performed on a standard mold using a line type micro-pattern core having an aspect ratio of 2, a slenderness ratio of 70, a pattern size of $200{\mu}m$, and a pattern spacing of $150{\mu}m$. During the filling process, the deformation of the mold with large aspect ratio and slenderness ratio was analyzed by the experiment and the numerical simulation according to the position of the gate. We proposed a mold structure that minimizes mold deformation by gate modification and enables uniform pattern filling behavior.

마이크로 포커스 X-ray CT를 이용한 콘크리트 손상균열의 정량적 평가 (Quantitative Evaluation of Concrete Damage by X-ray CT Methods)

  • 정자혜
    • 지질공학
    • /
    • 제28권3호
    • /
    • pp.455-463
    • /
    • 2018
  • 본 연구에서는 치핑작업중에 콘크리트에 발생할 수 있는 손상균열을 정량분석하기 위해 X-ray CT 이미지를 이용하는 방법을 제안하고자 한다. 이를 위해 치핑작업을 수행한 후, 균열이 발생한 콘크리트 블록을 코어링하여 직경 50 mm, 길이 100 mm의 시편을 준비하였다. 그 후 마이크로 포커스 X-ray CT 촬영을 하여 얻은 이미지를 3D 이미지로 재구성(reconstruction)하였다. 이렇게 얻어진 3D CT 이미지에 3DMA (3 Dimensional Medial axis Analysis)법을 적용하여, 손상 평가 파라메타로 시편의 위치에 따라 균열의 성질을 평가하여 손상을 분석하였다. 분석결과 치핑에 의한 손상은 치핑 표면으로부터 3 cm 깊이까지 발생한 것으로 나타났다. 또한 CT이미지 공간분석법에서 사용되는 여러 파라메타 중 공극률 지표(Porosity index), Burn number 그리고 Medial axis 의 파라메타를 이용해 치핑표면 근처의 손상 분석이 가능하다는 것이 확인되었다. 이 방법은 내부구조에 변화가 발생한 암석을 대상으로 한 연구에서도 비파괴 상태로 내부의 균열 평가, 가시화에 적용가능하다.

동적 시준을 이용한 CT 촬영과 볼록한 관심영역의 영상재구성 (Dynamically Collimated CT Scan and Image Reconstruction of Convex Region-of-Interest)

  • 진승오;권오경
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.151-159
    • /
    • 2014
  • Computed tomography (CT) is one of the most widely used medical imaging modality. However, substantial x-ray dose exposed to the human subject during the CT scan is a great concern. Region-of-interest (ROI) CT is considered to be a possible solution for its potential to reduce the x-ray dose to the human subject. In most of ROI-CT scans, the ROI is set to a circular shape whose diameter is often considerably smaller than the full field-of-view (FOV). However, an arbitrarily shaped ROI is very desirable to reduce the x-ray dose more than the circularly shaped ROI can do. We propose a new method to make a non-circular convex-shaped ROI along with the image reconstruction method. To make a ROI with an arbitrary convex shape, dynamic collimations are necessary to minimize the x-ray dose at each angle of view. In addition to the dynamic collimation, we get the ROI projection data with slightly lower sampling rate in the view direction to further reduce the x-ray dose. We reconstruct images from the ROI projection data in the compressed sensing (CS) framework assisted by the exterior projection data acquired from the pilot scan to set the ROI. To validate the proposed method, we used the experimental micro-CT projection data after truncating them to simulate the dynamic collimation. The reconstructed ROI images showed little errors as compared to the images reconstructed from the full-FOV scan data as well as little artifacts inside the ROI. We expect the proposed method can significantly reduce the x-ray dose in CT scans if the dynamic collimation is realized in real CT machines.

지도학습 기반 분할기법을 이용한 단층 촬영된 단방향 복합재료의 유한요소모델 생성 및 검증 (Generation and Validation of Finite Element Models of Computed Tomography for Unidirectional Composites Using Supervised Learning-based Segmentation Techniques)

  • 김대의;진성원;김영배;임재혁;김윤호
    • Composites Research
    • /
    • 제36권6호
    • /
    • pp.395-401
    • /
    • 2023
  • 본 연구에서는 지도학습 기반 분할기법을 이용하여 단층 촬영된 단방향 복합재료의 유한요소모델링을 실시하였다. 우선, 단방향 복합재료의 형상 정보를 얻기 위해 Micro-CT 스캔을 수행하여 단방향 복합재료의 순수 체적(raw volume)을 획득하였고 여기에 몇 개의 단면을 선택하여 재료의 마이크로 구조인 섬유의 형상을 라벨링하였다. 이후 재료의 단면 이미지와 라벨링한 이미지를 각각 입출력으로 U-net 모델을 훈련시켰다. 이를 사용하여 선택되지 않은 단층촬영 이미지를 섬유형상을 구분하는 분할을 수행하였고 이렇게 생성된 3차원 정보를 이용해서 유한요소모델을 생성하였다. 최종적으로 단방향 복합재료 시편과 유한요소모델의 섬유체적비를 비교하여 제안된 방법의 적절성을 확인하였다.

PET-CT 검사 시 호흡 동조 시스템들의 유용성 평가 (An Assessment of the Utility of Respiratory Synchronized Systems in the PET/CT Examination)

  • 성용준;윤석환;현준호;이홍재;김진의
    • 핵의학기술
    • /
    • 제21권1호
    • /
    • pp.34-38
    • /
    • 2017
  • PET/CT 검사 시 호흡으로 인한 내부장기의 움직임은 여러 호흡주기 동안 영상화되어 종양크기는 실제보다 증가하고 SUV에도 영향을 미치게 된다. 호흡 동조 시스템들을 이용하여 종양크기와 SUV 변화 유무를 평가해보고자 한다. 장비는 Biograph mCT 64를 사용하였고 호흡 동조 시스템은 RPM과 Anzai 시스템을 사용하였다. 실험을 위해 Point source와 Micro-phantom을 환자는 2016년 8월에서 9월까지 폐 기저부 또는 간 상부에 고형종양이 확인된 환자 12명을 대상으로 호기-호흡상태에서의 PET영상과 호기 후 멈춤 상태의 CT영상을 얻어 기존 Static, RPM, Anzai방식에서의 방사능 농도(kBq/mL), SUVmax, Cylinder diameter(mm), Tumor diameter (mm) 변화 유무를 평가하였다. Point source 방사능 농도 측정 결과 Static 대비 RPM 94%, Anzai 91% 상승하였고 Micro-phantom에서 방사능량을 달리한 2개의 Cylinder에서 SUVmax값은 Static 대비 RPM 61%, 78%, Anzai 58%, 77%로 각각 상승하였고 Cylinder diameter는 RPM -26%, -28%, Anzai -28%, -26% 감소하였다. 환자의 경우 SUVmax값은 Static 대비 RPM은 최소 8.2%에서 최대 94.4%, Anzai는 최소7.6%에서 최대 68.3% 상승하였고 Tumor diameter는 RPM은 최소 -7.6%에서 최대 -28.9%, Anzai는 최소 -9.6%에서 최대 -27.7% 감소하였다. 호흡 동조 시스템 RPM과 Anzai에서 phantom study는 별 차이가 없었지만 환자의 종양에서는 유의미한 차이가 있었다(P<0.05). 호흡 동조 시스템 RPM과 Anzai는 호흡이 일정한 주기로 이루어지는 phantom study에서 별 차이가 없었지만 환자의 경우 일정하지 않은 호흡주기와 시스템간 차이 때문에 유의미한 차이가 발생함을 알 수 있었다. 하지만 호흡 동조 시스템은 기존 Static 대비 종양의 크기는 감소하고 SUV는 증가하여 정확한 진단과 SUV측정에 유용할 것으로 사료된다.

  • PDF