Micro-Vibration Test on a Two-Axis Gimbal Antenna System with Stepping Motors (스텝핑 모터 특성에 따른 2축 짐발 안테나 시스템의 미소진동 측정 시험)

  • Kim, Dae-Kwan;Choi, Hong-Taek;Park, Gee-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.420-424
    • /
    • 2012
  • A 2-axis gimbal system is one of main disturbance sources affecting on image jitter response of a satellite. The gimbal system can be rotated on its azimuth and elevation axes, resulting in variation of its moment of inertia and structural modes, so that generates non-linear vibration characteristics. In order to estimate the jitter response, it is an indispensable process to characterize micro-vibration disturbance of the 2-axis gimbal system. In the present research, the vibration characteristics of the 2-axis gimbal system was investigated with respect to the types of stepping motors. The micro-vibration tests were performed for 2-phase and 5-phase stepping motors. The test results show that the disturbance can be reduced with vibration attenuation ratio of 60% by replacing the 2-phase stepping motor with the 5-phase one.

  • PDF

Micro-Vibration Measurement, Analysis and Attenuation Techniques of Reaction Wheel Assembly in Satellite (인공위성 반작용휠의 미소진동 측정, 해석 및 저감 기술)

  • Oh, Shi-Hwan;Rhee, Seung-Wu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.8
    • /
    • pp.126-132
    • /
    • 2002
  • Jitter induced from several payloads on-board satellites degrade the performance of pointing accuracy and attenuate the resolving power of highly-precise camera image such as KOMPSAT II. In this paper, we introduce a micro-vibration measurement technique, analysis of dynamic characteristics, and modeling method for a reaction wheel assembly which is one of the major sources of jitter in satellites and an effective vibration reduction techniques are considered. Based on these techniques, vibration measurement and passive control were performed with an micro-vibration generator which was designed to have similar dynamic performances with an actual reaction wheel assembly above 50Hz.

Micro-vibration Test on a Two-axis Gimbal Antenna System with Stepping Motors (스텝핑 모터 특성에 따른 2축 짐발 안테나 시스템의 미소진동 측정 시험)

  • Kim, Dae-Kwan;Yong, Ki-Lyuk;Choi, Hong-Taek;Park, Gee-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.11
    • /
    • pp.1042-1048
    • /
    • 2012
  • A 2-axis gimbal system is one of main disturbance sources affecting image jitter response of a satellite. The gimbal system comprises azimuth stage and elevation stage, and these pointing mechanism can be rotated by stepping motors about its azimuth and elevation axes simultaneously. Because of the complex and coupled dynamic motion of the gimbal system, its moment of inertia and structural modes can be changed according to the system configuration, and thus the gimbal system generates complicated and non-linear disturbance characteristics. In order to improve the jitter response of a spacecraft, it is an indispensable process to reduce the micro-vibration disturbance level of the antenna system. In the present research, a 2-axis gimbal system was manufactured and then its micro-vibration test was performed in terms of two types of stepping motors(2-phase and 5-phase). The test results show that the disturbance level of the gimbal system can be reduced by replacing the 2-phase stepping motor with the 5-phase one, and the average disturbance attenuation ratio is 56 % in peak level and 48 % in standard deviation level. The experimental results confirm that it is an efficient jitter reduction method to adopt a high-phase stepping motor.

Vibration Reduction Device for Directional Moving Satellite Antenna (지향성을 가지고 동작하는 위성 안테나 진동저감 장치 )

  • SeokWeon Choi;Sang-Soon Yong
    • Journal of Space Technology and Applications
    • /
    • v.2 no.3
    • /
    • pp.187-194
    • /
    • 2022
  • Although the magnitude of the disturbance caused by the driving of the motor operated to secure the high-speed and precise directivity of the antenna is small, it acts as a major cause of impairing the image quality of the observation satellite, which requires precision directing performance. In order to acquire high-resolution image information through the improvement of the high-resolution observation satellite, proper vibration isolation and reduction design are required so that jitter generated when the directional antenna motor is driven is not transmitted to the main mission equipment. In this paper, the development process of the directional antenna vibration reduction device applied to real satellites and the effect of micro vibration reduction before and after application will be examined. This device was designed as a way to significantly improve the jitter problem by replacing only one gear in the directional antenna driving unit with a spring damper gear without any additional interface equipment. It was first applied and launched to a high-resolution earth observation satellite, and has been successfully operated so far.

STSAT RWA Micro-Vibration Test and Analysis (과학기술위성 반작용휠의 미소진동 측정 및 분석)

  • Oh, Shi-Hwan;Nam, Myeong-Ryong;Park, Yon-Mook;Yim, Jo-Ryeong;Keum, Jung-Hoon;Rhee, Seung-Wu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.695-698
    • /
    • 2004
  • STSAT RWA (Reaction Wheel Assembly) micro-vibration is measured using KISTLER dynamic plate that can provide the time signals of three orthogonal forces and torques simultaneously up to 400Hz. In the post-processing, measured data are evaluated with respect to the wheel spin rate in both time and frequency domains, and the static/dynamic unbalances are evaluated from the extracted first harmonic component. Also the friction torque profile at each wheel speed is estimated from the measured data. Several higher order harmonic components are observed, that comes from its rotor shape as well as the wheel bearing characteristics. One of the most peculiar characteristics of this wheel is that the dynamic properties of two radial unbalance components are much different from each other as the RWA mounting configuration on a spacecraft is different from conventional RWA mounting configuration. Rocking mode is not appeared below 400Hz for all operating speed because the wheel size is very small. The post-processed results will be used for jitter analysis of STSAT due to RWA micro-vibration.

  • PDF

Analytical & Experimental Study on Microvibration Effects of Satellite (인공위성의 미소 진동 영향성에 관한 해석 및 실험적 연구)

  • Park, Geeyong;Lee, Dae-Oen;Yoon, Jae-San;Han, Jae-Hung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.533-539
    • /
    • 2013
  • Number of components and payload systems installed in satellites were found to be exposed to various disturbance sources such as the reaction wheel assembly, the control moment gyro, coolers, and others. A micro-level of vibration can introduce jitter problems into an optical payload system and cause significant degradation of the image quality. Moreover, the prediction of on-orbit vibration effects on the performance of optical payloads during the development process is always important. However, analyzing interactions between subsystems and predicting the vibration level of the payloads is extremely difficult. Therefore, this paper describes the analytical and experimental approach to microvibration effects on satellite optical payload performance with integrated jitter analysis framework, micro vibration emulator and satellite structure testbed.

  • PDF

Performance Test of Isolator for Reaction Wheel Micro-Vibration (인공위성 반작용휠 미소진동 감쇠기의 성능 측정)

  • Oh, Shi-Hwan;Seo, Hyun-Ho;Yim, Jo-Ryeong;Rhee, Seung-Wu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.376-379
    • /
    • 2006
  • Reaction Wheel Assembly (RWA) is one of the major disturbance sources that have influence upon the Line of Sight (LOS) of payload. A micro-vibration induced by RWA is propagated through the satellite structure and decrease the LOS stability performance of payload. This effect shall be analyzed through the jitter analysis. If a requirement or specification of payload jitter level is found to be not satisfied according to the jitter analysis campaign, some modification or redesign should be done on the satellite structure or a couple of isolator should be attached on the RWA interface in order to reduce the transmitted vibration level of RWA. The purpose of ???RWA isolator test? is to roughly evaluate the performance of vibration suppression level with a passive RWA isolator made of rubber. For this test, actual RWA is used as a vibration source and a couple of cube-shaped rubber mount designed for satellite is used as a passive isolator. There may be several considerations in order to accommodate RWA isolator to spacecraft such as not only vibration reduction performance but also thermal conduction problem, mechanical size, RWA alignment problem, etc. But in this report the feasibility of RWA isolator is analyzed only in a vibration suppression point of view. As a result, high frequency vibration of RWA above 50Hz is perfectly attenuated with isolators, however, first harmonic components below 50Hz became larger due to the additional low frequency resonance modes of roll, pitch, yaw rigid body motion of RWA+bracket.

  • PDF

TAMAM RWA Micro-Vibration Test and Analysis (TAMAM 반작용휠의 미소진동 측정 및 분석)

  • 오시환;이승우;최홍택;이선호;용기력
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.836-839
    • /
    • 2003
  • In this paper, we briefly introduce the test bench and test method of RWA micro-vibration. TAMAM RWA (Reaction Wheel Assembly) micro-vibration was measured on a KISTLER dynamic plate which can measure time signals of three orthogonal forces and torques simultaneously up to 400Hz, and test data was analyzed. Measured data were evaluated with respect to the wheel spin rate and the static/dynamic unbalances were estimated from the extracted first harmonic component. The estimated static and dynamic unbalances were 0.79gㆍcm and 17.4gㆍ$\textrm{cm}^2$ respectively. The resonance mode and two rocking modes were observed as a results of its frequency analysis. Several higher order harmonic components were observed, which comes from its rotor shape as well as the wheel bearing.

  • PDF

Optimal positioning of reaction wheel assemblies of optical observation satellite for minimizing image quality degradation (광학관측위성의 영상품질열화 최소화를 위한 반작용휠 최적위치 선정)

  • Im, Jeong Heum;Lim, Jae Hyuk;Kim, Kyung-Won;Yoon, Hyung-Joo;Kim, Sung-Hoon
    • Journal of Aerospace System Engineering
    • /
    • v.12 no.6
    • /
    • pp.9-16
    • /
    • 2018
  • This paper describes how to find out the optimum position of the reaction wheel assembly (RWA) to minimize image quality degradation through the integrated system jitter prediction combining the micro-vibration test with finite element analysis considering optical coefficients. Micro-vibration generated from RWA that is widely used for satellite maneuver, is one of key factors that degrades the quality of satellite image. Due to varying vibration characteristics of each RWA, its accommodation position may affect image quality even though the same company manufactured them. To resolve this issue, an integrated system jitter prediction is conducted with all possible RWA accommodation location, and finally we determine optimal RWA position from the analysis results.

Verification of Micro-vibration Isolation Performance by using Low Rotational Stiffness Isolator under Elevation Direction Operation of the X-band Antenna (저 회전강성 진동 절연기에 의한 X-밴드 안테나의 고각방향 미소진동 절연 효과 검증)

  • Jeon, Su-Hyeon;Lee, Jae-Gyeong;Jeong, Sae-Han-Sol;Lee, Myeong-Jae;Oh, Hyun-Ung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.4
    • /
    • pp.238-246
    • /
    • 2015
  • A stepping motor is widely used to operate the elevation and azimuth stage of the X-band antenna with 2-axis gimbal system for effective image data transmission from a satellite to a ground station. However, such stepping motor also generates an undesirable micro-vibration which is one of the main disturbance sources affecting image quality of the high-resolution observation satellite. In order to improve the image quality, the micro-vibration isolation of the X-band antenna system is essential. In this study, the low rotational stiffness isolator has been proposed to reduce the micro-vibration disturbance induced by elevation direction operation of the X-band antenna. In addition, its structural safety was confirmed by the structure analysis based on the derived torque budget. The effectiveness of the design was also verified through the micro-vibration measurement test.