• 제목/요약/키워드: Micro-sized

검색결과 404건 처리시간 0.026초

마이크로 ESPI기법을 이용한 동 박막의 인장 특성 측정 (Measurement of Tensile Properties of Copper Foil using Micro-ESPI Technique)

  • 김동일;허용학;기창두
    • 한국정밀공학회지
    • /
    • 제21권8호
    • /
    • pp.89-96
    • /
    • 2004
  • Micro-tensile testing system, consisting of a micro tensile loading system and micro-ESPI(Electronic Speckle Pattern Interferometry) system, has been developed for measurement of micro-tensile properties of thin micro-materials. Micro-tensile loading system had a load cell with the maximum capacity of 50N and micro actuator with resolution of 4.5nm in stroke. The system was used to apply a tensile load to the micro-sized specimen. During tensile loading, the micro-ESPI system acquired interferornetric speckle patterns in the deformed specimen and measured the in-plane tensile strain. The ESPI system consisted of a CCD-camera with a lens and the window-based program developed for this experiment. Using this system, stress-strain curves for 4 kinds of electrolytic copper foil 18$\square$m thick were obtained. From these curves, tensile properties, including the elastic modulus. yielding strength and tensile strength, were determined and also values of the plastic exponent and coefficient based on Ramberg-Osgood relationship were evaluated.

마이크로 체결부품 전조성형공정에 관한 해석 및 실험적 고찰(Part II: M0.8급 마이크로 스크류 전조공정 적용) (Numerical Analysis and Experimental Study of Thread Rolling Process for Micro-sized Screws(Part II: Application to a Micro-screw with Diameter of 800㎛))

  • 송정한;이종섭;이혜진;이근안;박기동;나승우;이형욱
    • 소성∙가공
    • /
    • 제21권3호
    • /
    • pp.179-185
    • /
    • 2012
  • In this paper, it is proposed to produce high precision screws with a diameter of $800{\mu}m$ and a thread pitch of $200{\mu}m$ ($M0.8{\times}P0.2$) by means of a cold thread rolling process. In this part II of the study, the focus is on the production and reliability testing of the prototype $M0.8{\times}P0.2$ micro-screw. Designs for two flat dies were developed with the aid of the literature and previous studies. Process parameters during the cold thread rolling process were established through FE simulations. The simulation results showed that the threads of the micro-screw are completely formed through the rolling process. Prototype $M0.8{\times}P0.2$ micro-screw were fabricated with a high precision thread rolling machine. In order to verify the simulation results, the deformed shape and dimensions obtained from the experiment were compared with those from the simulations. Hardness and failure torque of the fabricated micro-screw were also measured. The values obtained indicate that the CAE based process design used in this paper is very appropriate for the thread rolling of micro-sized screws.

미세유체칩내 electrode의 opening window형태에 따른 유전전기영동력 특성 규명 (Characterization of Dielectrophoretic Force for the Structural Shapes of Window in Microfluidic Dielectrophoretic Chip)

  • 이재우;곽태준;윤대성;이상우
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권4호
    • /
    • pp.189-196
    • /
    • 2013
  • Dielectrophoresis(DEP) is useful in manipulation and separation of micro-sized particles including biological samples such as bacteria, blood cells, and cancer cells in a micro-fluidic device. Especially, those separation and manipulation techniques using DEP in combination of micro fabrication technique have been researched more and more. Recently, it is revealed that a window structure of insulating layer in microfluidic DEP chip is key role in trap of micro-particles around the window structure. However, the trap phenomenon-driven by DEP force gradient did not fully understand and is still illusive. In this study, we characterize the trap mechanism and efficiency with different shapes of window in a microfluidic DEP chip. To do this characterization, we fabricated 4 different windows shapes such as rhombus, circle, squares, and hexagon inside a micro-fluidic chip, and performed micro-sized particles manipulation experiments as varying the frequency and voltage of AC signal. Moreover, the numerical simulation with the same parameters that were used in the experiment was also performed in order to compare the simulation results and the experimental results. Those comparison shows that both results are closely matched. This study may be helpful in design and development of microfluidic DEP chip for trapping micro-scaled biological particle.

나노 박막을 이용한 듀얼 $SnO_2$ 마이크로 가스센서 어레이 (A Dual Micro Gas Sensor Array with Nano Sized $SnO_2$ Thin Film)

  • 정완영
    • 한국정보통신학회논문지
    • /
    • 제10권9호
    • /
    • pp.1641-1647
    • /
    • 2006
  • 나노입자 크기를 가진 얇은 $SnO_2$ 박막을 이용하여 CO 및 $H_2S$에 대한 우수한 감도를 가지는 복합 마이크로 가스센서 어레이를 제작하였다. 나노입자의 박막을 만들기 위해서 약 $2500{\AA}$ 두께의 $SnO_2,\;SnO_2(+Pt),\;SnO_2(+CuO)$ 막을 셰도우마스크를 사용하여 형성 한 후, 이를 $600{\sim}800^{\circ}C$의 온도에서 산화하므로서 나노입자의 $SnO_2$ 모물질의 가스감지 박막을 형성하였다. 실리콘 기판의 마이크로센서의 형태로 제작된 $SnO_2(Pt)$$SnO_2(+CuO)$ 가스센서는 각각 CO 및 $H_2S$ 가스에 대한 매우 우수한 감도를 나타내는 것을 확인하였다.

Milli-Structure 생산기술개발 (Development of Manufacturing Technology for Milli-Structure)

  • 나경환;박훈재;조남선
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.1039-1042
    • /
    • 2000
  • This research will deal with Innovative manufacturing technology for milli-structure manufacturing technology which is located betweon the traditional manufacturing technology for macro-sized structure and the recently emerging manufacturing technology for micro-scaled structure such as MEMS. There are four fields in this research, which are micro-sheet metal forming technology, micro-bulk forming technology micro-molding technology and micro die making technology. As a project for new-technology in next generation, this research will be carried out through three terms and each term and be composed of three years.

  • PDF

Pd 촉매금속의 표면형상 변형에 의한 고감도 MEMS 형 마이크로 수소가스 센서 제조공정 (Highly Sensitive MEMS-Type Micro Sensor for Hydrogen Gas Detection by Modifying the Surface Morphology of Pd Catalytic Metal)

  • 김정식;김범준
    • 한국재료학회지
    • /
    • 제24권10호
    • /
    • pp.532-537
    • /
    • 2014
  • In this study, highly sensitive hydrogen micro gas sensors of the multi-layer and micro-heater type were designed and fabricated using the micro electro mechanical system (MEMS) process and palladium catalytic metal. The dimensions of the fabricated hydrogen gas sensor were about $5mm{\times}4mm$ and the sensing layer of palladium metal was deposited in the middle of the device. The sensing palladium films were modified to be nano-honeycomb and nano-hemisphere structures using an anodic aluminum oxide (AAO) template and nano-sized polystyrene beads, respectively. The sensitivities (Rs), which are the ratio of the relative resistance were significantly improved and reached levels of 0.783% and 1.045 % with 2,000 ppm H2 at $70^{\circ}C$ for nano-honeycomb and nano-hemisphere structured Pd films, respectively, on the other hand, the sensitivity was 0.638% for the plain Pd thin film. The improvement of sensitivities for the nano-honeycomb and nano-hemisphere structured Pd films with respect to the plain Pd-thin film was thought to be due to the nanoporous surface topographies of AAO and nano-sized polystyrene beads.

Development of Multiple Beam Optical Tweezers

  • Lee Dong-Jin;LeBrun Thomas W.;Balijepalli Arvind;Gorman JasonJ.;Gagnon Cedric;Hong Dae-Hie;Chang Esthe rH.
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1501-1506
    • /
    • 2005
  • This paper presents the design of a multiple beam optical tweezers instrument used for manipulating micro/nano-sized components. The basic equations used in designing the optical tweezers are derived and the stable and time-sharing multiple beam optical tweezers are constructed with scanning mirrors. The laser beam passes through a series of optical components such as lenses, mirrors, and scanning mirrors, and overfills the entrance aperture of microscope objective, which gives a stable trap. By rotating the laser beam with the scanning mirror, the focal positions are translated in the specimen plane and multiple micro/nano-sized objects can be moved. The constructed optical tweezers is used to manipulate cells and liposomes simultaneously and to trap multiple nano-wires. The experiments prove that the developed optical tweezers can be a very versatile manipulation tool for studying gene therapy and nano device fabrication.

  • PDF

정전기력 기반의 마이크로 사이즈 폴리머 비드 주입 공정 연구 (A research about micro size polymer bead injecting process based on electrostatic force)

  • 양봉수;양성욱;고정범;최경현;도양회
    • 동력기계공학회지
    • /
    • 제20권2호
    • /
    • pp.43-50
    • /
    • 2016
  • This research proposal is based on a novel non-contact technique of micro-sized bead injection process for fabrication of electronic paper display. This non-contact injection process is based on the principle of electrostatic force and uses micro-sized metal-coated beads dispersed in a solution. The dispersion retention times of three different solutions with viscosities of 10 cps, 100 cps, and 1000 cps were measured by optical equipment showing the retention times of 5 mins, 10 mins, and 30 mins respectively. The dispersion retention rate dropped as the time passed. The dispersion retention characteristic of 1000 cps solution was more stable as compared to those of 10 cps and 100 cps meaning that higher viscosity has better retention properties. The experimental results of bead injection at different viscosity levels of the solution were also measured and a stable injection result was achieved by using 1000 cps solution. This results show that stable injection is dependent on solution viscosity and dispersion.

The Role of Government Expenditure and Investment for MSME Growth: Empirical Study in Indonesia

  • PRASETYO, P. Eko
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제7권10호
    • /
    • pp.471-480
    • /
    • 2020
  • In Indonesia, micro-, small- and medium-sized enterprises (MSMEs) are introduced to increase income by providing many easier jobs to improve economic growth. They have also been reported to be generally supportive of the local industry. The government policies on investment and expenditure have the ability to promote MSMEs and economic growth. Therefore, this research was conducted to analyze the theoretical background and empirical study to investigate government's role to promote MSMEs growth in Indonesia. The secondary data after the 2008 global financial crisis recorded quarterly from 2009 to 2019 Q3 were analyzed using the Ordinary Least Square (OLS) regression model. The results showed government expenditure has a positive and significant contribution to small- and medium-sized enterprises, but the effect was not significant for micro-businesses. Meanwhile, the investment sector was discovered to have a positive and significant effect on MSMEs. The policy implications of the Indonesian government are expected to focus on its expenditure's role as the most important factor for "social-economic protection of the community" through micro-enterprises, which are numerous and more attached to the real community economic-social life. Therefore, the existence of micro-businesses is very helpful for the lower classes despite their high vulnerability to crisis.

Comparative study on the effects of micro- and nano-sized zinc oxide supplementation on zinc-deficient mice

  • Ja-Seon Yoon;Sang Yoon Nam;Beom Jun Lee;Hyun Jik Lee
    • Journal of Veterinary Science
    • /
    • 제24권1호
    • /
    • pp.3.1-3.13
    • /
    • 2023
  • Background: Zinc (Zn) is an essential cofactor for physiological homeostasis in the body. Zn oxide (ZnO), an inorganic compound that supplies Zn, exists in various sizes, and its bioavailability may vary depending on the size in vivo. However, comparative studies on the nutritional effects of micro-sized ZnO (M-ZnO) and nano-sized ZnO (N-ZnO) supplementation on Zn deficiency (ZnD) animal models have not been reported. Objectives: This study investigated the nutritional bioavailability of N-ZnO and M-ZnO particles in dietary-induced ZnD mice. Methods: Animals were divided into six experimental groups: normal group, ZnD control group, and four ZnO treatment groups (Nano-Low, Nano-High, Micro-Low, and MicroHigh). After ZnD induction, N-ZnO or M-ZnO was administered orally every day for 4 weeks. Results: ZnD-associated clinical signs almost disappeared 7 days after N-ZnO or M-ZnO administration. Serum Zn concentrations were higher in the Nano-High group than in the ZnD and M-ZnO groups on day 7 of ZnO treatment. In the liver and testis, Nano-Low and Nano-High groups showed significantly higher Zn concentrations than the other groups after 14-day treatment. ZnO supplementation increased Mt-1 mRNA expression in the liver and testis and Mt-2 mRNA expression in the liver. Based on hematoxylin-and-eosin staining results, N-ZnO supplementation alleviated histological damage induced by ZnD in the testis and liver. Conclusions: This study suggested that N-ZnO can be utilized faster than M-ZnO for nutritional restoration at the early stage of ZnD condition and presented Mt-1 as an indicator of Zn status in the serum, liver, and testis.