• 제목/요약/키워드: Micro-sized

검색결과 404건 처리시간 0.03초

Toxicity of Two Different Sized Lanthanum Oxides in Cultured Cells and Sprague-Dawley Rats

  • Lim, Cheol-Hong
    • Toxicological Research
    • /
    • 제31권2호
    • /
    • pp.181-189
    • /
    • 2015
  • In recent years, the use of both nano- and micro-sized lanthanum has been increasing in the production of optical glasses, batteries, alloys, etc. However, a hazard assessment has not been performed to determine the degree of toxicity of lanthanum. Therefore, the purpose of this study was to identify the toxicity of both nano- and micro-sized lanthanum oxide in cultured cells and rats. After identifying the size and the morphology of lanthanum oxides, the toxicity of two different sized lanthanum oxides was compared in cultured RAW264.7 cells and A549 cells. The toxicity of the lanthanum oxides was also analyzed using rats. The half maximal inhibitory concentrations of micro-$La_2O_3$ in the RAW264.7 cells, with and without sonication, were 17.3 and 12.7 times higher than those of nano-$La_2O_3$, respectively. Similar to the RAW264.7 cells, the toxicity of nano-$La_2O_3$ was stronger than that of micro-$La_2O_3$ in the A549 cells. We found that nano-$La_2O_3$ was absorbed in the lungs more and was eliminated more slowly than micro-$La_2O_3$. At a dosage that did not affect the body weight, numbers of leukocytes, and concentrations of lactate dehydrogenase and albumin in the bronchoalveolar lavage (BAL) fluids, the weight of the lungs increased. Inflammatory effects on BAL decreased over time, but lung weight increased and the proteinosis of the lung became severe over time. The effects of particle size on the toxicity of lanthanum oxides in rats were less than in the cultured cells. In conclusion, smaller lanthanum oxides were more toxic in the cultured cells, and sonication decreased their size and increased their toxicity. The smaller-sized lanthanum was absorbed more into the lungs and caused more toxicity in the lungs. The histopathological symptoms caused by lanthanum oxide in the lungs did not go away and continued to worsen until 13 weeks after the initial exposure.

침전법과 고상반응법으로 제조한 $ZnGa_2O_4$ 형광체의 특성 (Characteristics of $ZnGa_2O_4$ phosphor prepared by Precipitation method and Solid-state reaction method)

  • 차재혁;김세준;곽현호;최형욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.383-384
    • /
    • 2007
  • The nano and micro-sized $ZnGa_2O_4$ phosphor were prepared by precipitation method and solid-state method. The luminescence, formation process and structure of phosphor powders were investigated by means of XRD, SEM and PL. The result of XRD analysis showed that $ZnGa_2O_4$ spinel structure was formed at as-prepared in the case of precipitation method. However, micro-sized phosphor was required high heating treatment to have a satisfactory spinel structure. The CL intensity of nano-sized phosphor was about 4-fold higher than that of micro-sized phosphor. The emission spectra of all $ZnGa_2O_4$ phosphor show a self activated blue emission band at around 420 nm in the wide range of 300~600 nm.

  • PDF

마이크로 ESPI 기법에 의한 면내 변형 측정 민감도 향상 (Improvement of Sensitivity to In-plane Strain/Deformation Measurement by Micro-ESPI Technique)

  • 김동일;허용학;기창두
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1442-1445
    • /
    • 2005
  • Several test methods, including micro strain/deformation measurement techniques, have been studied to more reliably measure the micro properties in micro/nano materials. Therefore, in this study, the continuous measurement of in-plane tensile strain in micro-sized specimens of thin film materials was introduced using the micro-ESPI technique. TiN and Au thin films 1 and $0.47\;\mu{m}$ thick, respectively, were deposited on the silicon wafer and fabricated into the micro-sized tensile specimens using the electromachining process. The micro-tensile loading system and micro-ESPI system were developed to measure the tensile strain during micro-tensile test. The micro-tensile stress-strain for these materials was determined using the algorithm for continuous strain measurement. Furthermore, algorithm for enhancing the sensitivity to measurement of in-plane tensile strain was suggested. According to the algorithm for enhancement of sensitivity, micro-tensile strain data between interfringe were calculated. It is shown that the algorithm for enhancement of the sensitivity suggested in this study makes the sensitivity to the in-plane tensile strain increase.

  • PDF

미세접촉인쇄기법의 설계와 다중스케일해석 (Design and Multi-scale Analysis of Micro Contact Printing)

  • 김정엽;김재현;최병익
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1927-1931
    • /
    • 2003
  • Nanometer-sized structures are being applied to many fields including micro/nano electronics, optoelectronics, quantum computing, biosensors, etc. Micro contact printing is one of the most promising methods for manufacturing the nanometer-sized structures. The crucial element for the micro contact printing is the nano-resolution printing technique using polymeric stamps. In this study, a multi-scale analysis scheme for simulating the micro contact printing process is proposed and some useful analysis results are presented. Using the slip-link model [1], the dependency of viscoelasticity on molecular weight of polymer stamp is predicted. Deformation behaviors of polymeric stamps are analyzed using finite element method based upon the predicted viscoelastic properties.

  • PDF

A Newly Designed a TiO2-Loaded Spherical ZnS Nano/Micro-Composites for High Hydrogen Production from Methanol/Water Solution Photo-Splitting

  • Kim, Ji-Eun;Kang, Mi-Sook
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권7호
    • /
    • pp.2133-2139
    • /
    • 2012
  • A new system using $TiO_2$ (nano-sized, band-gap 3.14 eV)-impregnated spherical ZnS (micro-sized, band-gap 2.73 eV) nano/micro-composites (Ti 0.001, 0.005, 0.01, and 0.05 mol %/ZnS) was developed to enhance the production of hydrogen from methanol/water splitting. The ZnS particles in a spherical morphology with a diameter of about 2-4 mm which can absorb around 455 nm were prepared by hydrothermal method. This material was used as a photocatalyst with loading by nano-sized $TiO_2$ (20-30 nm) for hydrogen production. The evolution of $H_2$ from methanol/water (1:1) photo splitting over the $TiO_2$/ZnS composite in the liquid system was enhanced, compared with that over pure $TiO_2$ and ZnS. In particular, 1.2 mmol of $H_2$ gas was produced after 12 h when 0.005 mol % $TiO_2$/ZnS nano/micro-composite was used. On the basis of cyclic voltammeter (CV) and UV-visible spectrums results, the high photoactivity was attributed to the larger band gap and the lower LUMO in the $TiO_2$/ZnS composite, due to the decreased recombination between the excited electrons and holes.

Self-cleaning measurements on tiles manufactured with micro-sized photoactive TiO2

  • Bianchi, C.L.;Gatto, S.;Nucci, S.;Cerrato, G.;Capucci, V.
    • Advances in materials Research
    • /
    • 제2권1호
    • /
    • pp.65-75
    • /
    • 2013
  • Heterogeneous photocatalysis is a rapidly developing field in environmental engineering. It has a great potential to cope with the increasing pollution in the air. The addition of a photocatalyst to ordinary building materials such as tiles, concrete, paints, creates environmental friendly materials by which air pollution or pollution of the surface itself can be controlled and diminished. This work reports the results of the laboratory research, especially carried out towards air purifying action and self-cleaning measurements. In particular the research was focused on the study of the photocatalytic behavior of industrially prepared tiles produced starting from commercial micro-sized $TiO_2$. Air purification action has been investigated through NOx degradation tests. On the contrary, the degradation of pollution at the surface, also called as self-cleaning action, is verified by the degradation of two different organic dyes: Rhodamine B (red color) and Metanil yellow (yellow).

AHP 모형을 활용한 소상공인 신용평가시스템 구축 (The Credit Evaluation System for Micro-small Sized Individual Firms Using the Analytic Hierarchy Process)

  • 이주민;김승연;하은호;노태협
    • 한국정보시스템학회지:정보시스템연구
    • /
    • 제16권3호
    • /
    • pp.109-132
    • /
    • 2007
  • In the paper, we builds an advanced new credit evaluation system for Micro-small sized individual firms through appropriate evaluation factors derived by logistic regression analysis for credit evaluation model using in Korean Federation of Credit Guarantee Foundations, and the weights of factors computed by analytic hierarchy process(AHP). Industry characteristics are more applied to previous credit model with the additional the financial fact-information and non-financial judgement-information. Our results show that the financial factors have become more important than three years ago. Moreover, in the non-financial factors, the fact-information factors consider more important then the judgement-information factors. A new credit evaluation system is developed based on this credit evaluation model.

  • PDF

기포를 이용한 미세 부유 폴리에틸렌 입자 포획에 대한 연구 (Study of capturing micro-sized floating polyethylene particles using a bubble)

  • 최진용;박형민
    • 한국가시화정보학회지
    • /
    • 제20권3호
    • /
    • pp.67-73
    • /
    • 2022
  • Underwater environmental pollution caused by microplastic particles is considered to be one of the most serious problems in many oceans and countries nearby. Previous academic studies or field technologies tried to remove the micro-sized particles are often energy-consuming and costly, so it is hard to be employed for the actual uses. In this study, the mechanism of removal of micro-sized polyethylene spheres (size in order of 100㎛) using a rising bubble is experimentally investigated. It is found that the particles are either affected by bubble wake, thus translocated close to the water surface, or pushed far away by the surrounding fluid flow, depending on their initial position relative to the bubble. By scrutinizing the visualized behaviors of bubble-particle interaction, we draw the governing parameter, i.e., the polar angle between the particle and the bubble, to determine the effective capturing of the particles with a rising bubble.

Design and Analysis of an Electro-Magnetic Micro Gripper for Grasping Miniature Sized Objects

  • Jaehong Shim;Won Choe;Kim, Kyunghwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.103.1-103
    • /
    • 2001
  • This paper presents the development of a micro gripper for grasping miniature sized parts in micro-assembly. Particularly, we have paid attention to the problem of manipulating objects of a well defined size range: the one between 1 mm and 0.1mm. In fact, objects larger than 1 mm can be easily handled by conventional precise grippers, while objects smaller than 1 $\mu\textrm{m}$ can be manipulated with special tools like AFM or STM. In this range, we can distinguish between mechanical and biological objects. We have focused our gripping research on the micro mechanical objects. We started from a f degree of freedom planar configuration. The structure of the micro gripper was a type of the elastic flexure hinge and was fabricated in ...

  • PDF

Micro-PIV measurement of internal flow in a micro droplet

  • KINOSHITA Haruyuki;KOBAYASHI Toshio;OSHIMA Marie
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2004년도 Proceedings of 2004 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.141-145
    • /
    • 2004
  • Visualization and PIV measurements of the symmetrical recirculation flow in a nanoliter-sized droplet have been performed using the micro PIV system. The airflow sweeps over the nanoliter-sized liquid droplet fixed in a microchannel and the frictional force drags the liquid on the round interface, which causes the symmetrical recirculation flow in the droplet. The internal recirculation flow in the droplet has been visualized and measured successfully. The results of micro PIV measurement show the maximum speed of the recirculation flow is up to 10 mm/s. The high-speed recirculation can enhance a stirring effect and generate strong shear in the droplet, resulting in acceleration of mixing.

  • PDF