• 제목/요약/키워드: Micro-gas turbine

검색결과 140건 처리시간 0.027초

삼성테크윈의 터보식 공기 압축기 소개 (An Introduction of a Turbo Air Compressor in STW)

  • 이형태;이영섭;권우성;문경찬;인배석
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.315-322
    • /
    • 2003
  • High performance turbo compressor, Turbo Master, was successfully developed by applying combined technology and experience based on aero gas turbine engines. The Turbo Master, developed using our own technology, was designed for high performance and reliability And the Turbo Master will supply absolutely oil-free compressed air to your facilities. In special, a next-generation micro compressor was lately developed, using air foil bearing and high speed motor known as the latest high technology.

  • PDF

바이오가스 마이크로 터빈 발전용 전처리시스템 전산유동해석 (Computational Fluid Dynamics Analysis of the Pretreatment System for Livestock BIO-GAS MGT Power Generation)

  • 허광범;박정극;임상규;김재훈
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.260-263
    • /
    • 2008
  • KEPCO(Korea Electric Power Corporation) is performing the nation's first biogas-MGT project as an effort to encourage the utilization of wasted biogas which contains useful CH4. The goals of this project are to develop the Pretreatment system of Livestock bio-gas and set up the biogas-MGT co-generation system. The project will not only utilze flared biogas as precious energy but also improve the economics of the plant a lot. The pretreatment system mainly consists of sulfur removal tower, biogas compressor and many filtering systems. A computational fluid dynamics study in the bio gas sulfur removal tower and sulfur absorption filter was carried out. Understanding of the flow in the sulfur removal tower and sulfur adsorption filter obtained by this study can be used to identify the problems in the sulfur removal tower and to improve the sulfur removal efficiency of the sulfur removal tower. Resistance material modeling is used to simulate the sulfur adsorption filter, and the resistance coefficient was adjusted to reflect the experimental pressure loss value. And the pressure loss change with the flowrate is predicted

  • PDF

Thermal and Electrical Energy Mix Optimization(EMO) Method for Real Large-scaled Residential Town Plan

  • Kang, Cha-Nyeong;Cho, Soo-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.513-520
    • /
    • 2018
  • Since Paris Climate Change Conference in 2015, many policies to reduce the emission of greenhouse gas have been accelerating, which are mainly related to renewable energy resources and micro-grid. Presently, the technology development and demonstration projects are mostly focused on diversifying the power resources by adding wind turbine, photo-voltaic and battery storage system in the island-type small micro-grid. It is expected that the large-scaled micro-grid projects based on the regional district and town/complex city, e.g. the block type micro-grid project in Daegu national industrial complex will proceed in the near future. In this case, the economic cost or the carbon emission can be optimized by the efficient operation of energy mix and the appropriate construction of electric and heat supplying facilities such as cogeneration, renewable energy resources, BESS, thermal storage and the existing heat and electricity supplying networks. However, when planning a large residential town or city, the concrete plan of the energy infrastructure has not been established until the construction plan stage and provided by the individual energy suppliers of water, heat, electricity and gas. So, it is difficult to build the efficient energy portfolio considering the characteristics of town or city. This paper introduces an energy mix optimization(EMO) method to determine the optimal capacity of thermal and electric resources which can be applied in the design stage of the real large-scaled residential town or city, and examines the feasibility of the proposed method by applying the real heat and electricity demand data of large-scale residential towns with thousands of households and by comparing the result of HOMER simulation developed by National Renewable Energy Laboratory(NREL).

매립가스 마이크로가스터빈 배가스 분석에 관한 실험적 연구 (Experimental Study of the Landfill Gas Fuelled Micro Gas Turbine Exhaust Gas Analysis)

  • 박정극;허광범;임상규;오일홍;이인화
    • 신재생에너지
    • /
    • 제7권3호
    • /
    • pp.67-73
    • /
    • 2011
  • MGT fuelled by landfill gas was tested to asses feasibility of its exhaust gas application for $CO_2$ enrichment. The exhaust gas was analyzed during start-up and normal operation with different MGT load conditions. Due to the changes of air/fuel ratio and combustion mode, $O_2$, $CO_2$, CO and NOx concentration were varied within wide ranges during the MGT start-up. Especially, NOx emissioin level was increased up to 20.01 ppmv. Different tendencies of $O_2$, $CO_2$, CO and NOx concentrations were observed with MGT output changes. $O_2$ and CO concentrations were shown to be decreased and NOx and $CO_2$ concentrations were shown to have opposite trends. NOx emission level (0.8~1.88 ppmv) was very low compared to other types of combustion based power generation equipment. Unburned hydrocarbon emission level was substantially decreased with MGT load increase. Especially, $C_2H_4$ concentration was below the detection limit(0.2 ppmv) around the nominal load condition. The exhaust gas from landfill gas fuelled MGT system was shown to be feasible for $CO_2$ fertilization. Concentrations of major components were within or below the maximum allowable ranges.

터보 제너레이터의 시동기 제어에 관한 연구 (A Study on the Starter Control of the Turbo Generator)

  • 박승엽;노민식
    • 제어로봇시스템학회논문지
    • /
    • 제10권3호
    • /
    • pp.286-293
    • /
    • 2004
  • This paper presents the result of a study on the starter control for a turbo generator. Because a starter in gear box type turbo-generator system is composed of gearbox and brush DC motor, it should be replaced with High Speed Generator(HSG)) in HSG type Turbo-generator. There-ore, it is necessary to design a new starting algorithm and starter. In gearbox type system, brush DC motor is rotated to the designed speed using low voltage-high current battery power. After brush DC motor speed is increased to several times by gearbox, gas turbine engine can be rotated to designed starting speed. If we implement a starter with High Speed Generator(HSG), it is necessary to drive high-speed generator to high-speed motor. High-speed generator with permanent magnet on rotor has a low leakage inductance fur driving high-speed rotation, and it is necessary high DC link voltage for inverter when High-speed generator is driven to high speed. This paper presents result of development of the boost converter for converting high voltage DC from low battery voltage and design of the inverter for controlling a high frequency current to be injected to motor winding. Also, we show performance of the designed starter by driving the turbo generator.

마이크로그리드 과도상태 시 전력 수급 균형 전략 (Power Balancing Strategy in the Microgrid During Transient)

  • 서재진;이학주;정원욱;원동준
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.707-714
    • /
    • 2010
  • When problems such as line fault, breakdown of a substation or a generator, etc. arise on the grid, the Microgrid is designed to be separated or isolated from the grid. Most existing DGs(Distributed Generators) in distribution system use rotating machine. However, new DGs such as micro gas turbine, fuel cell, photo voltaic, wind turbine, etc. will be interfaced with the Microgrid through an inverter. So the Microgrid may have very lower inertia than the conventional distribution system. By the way, the rate of change of frequency depends on the inertia of the power system. Moreover, frequency has a strong coupling with active power in power system. Because the frequency of the Microgrid may change rapidly and largely during transient, appropriate and fast control strategy is needed for stable operation of the Microgrid. Therefore, this paper presents a power balancing strategy in Microgrid during transient. Despite of strong power or frequency excursions, power balancing in the Microgrid can be maintained.

고속 발전기 직접 구동 방식의 터보 제너레이터 시스템 개발 (The Development of the Turbo Generator System with Direct Driving High Speed Generator)

  • 노민식;박승엽
    • 전자공학회논문지SC
    • /
    • 제40권6호
    • /
    • pp.87-94
    • /
    • 2003
  • 본 연구에서는 고속 발전기를 고속의 가스 터빈 엔진에 직결 장착한 터보 제너레이터 시스템의 개발 연구결과를 보인다. 고속 발전기를 직결 장착한 터보 제너레이터 시스템은 터보 샤프트 발전 시스템에 비하여 무게, 크기, 윤활 시스템, 시스템의 복잡성 측면에서 많은 장점을 가지고 있다. 그러나 고속 회전체 시스템의 직접 운전에 따른 안정된 고속 제너레이터의 설계, 가스 터빈 엔진의 시동 시의 신뢰성 있는 점화를 위한 고속 모터 구동 알고리즘 구현, 고 주파수의 출력 전력을 상용 교류전력 혹은 필요한 직류 전력을 얻기 위한 전력 변환 장치의 설계를 요구한다.

기상정보를 활용한 도시규모-EMS용 태양광 발전량 예측모델 (PV Power Prediction Models for City Energy Management System based on Weather Forecast Information)

  • 엄지영;최형진;조수환
    • 전기학회논문지
    • /
    • 제64권3호
    • /
    • pp.393-398
    • /
    • 2015
  • City or Community-scale Energy Management System(CEMS) is used to reduce the total energy consumed in the city by arranging the energy resources efficiently at the planning stage and controlling them economically at the operating stage. Of the operational functions of the CEMS, generation forecasting of renewable energy resources is an essential feature for the effective supply scheduling. This is because it can develop daily operating schedules of controllable generators in the city (e.g. diesel turbine, micro-gas turbine, ESS, CHP and so on) in order to minimize the inflow of the external power supply system, considering the amount of power generated by the uncontrollable renewable energy resources. This paper is written to introduce numerical models for photo-voltaic power generation prediction based on the weather forecasting information. Unlike the conventional methods using the average radiation or average utilization rate, the proposed models are developed for CEMS applications using the realtime weather forecast information provided by the National Weather Service.

플라즈마 용사 열차폐 코팅의 열화 평가 (Evaluation of Degradation of Isothermally Aged Plasma-Sprayed Thermal Barrier Coating)

  • 구재민;석창성;강민성;김대진;이동훈;김문영
    • 대한기계학회논문집A
    • /
    • 제34권4호
    • /
    • pp.475-480
    • /
    • 2010
  • 가스터빈 블레이드는 터빈 가동 시 발생하는 고온화염으로부터 블레이드를 보호하고, 구조물의 표면 온도를 안전한 수준으로 낮추기 위하여 블레이드 표면에 열차폐 코팅(TBC; Thermal barrier coating)을 하여 사용하고 있다. 본 논문에서는 가스터빈 1단 블레이드에 적용되는 코팅 방식을 이용하여 코인형 시험편을 제작하였고 열화 온도 및 유지 시간의 변화에 따른 코팅 계면 산화물의 성장 거동을 분석하였다. 코팅 단면에 대하여 코팅 계면 산화물의 두께와 마이크로 비커스 경도를 측정하여 열화 특성을 평가 하였다. 또한 성분분석을 통하여 미세조직의 변화를 관찰함으로써 열차폐 코팅의 열적 열화특성을 평가하였다.

Performance Analysis of SOFC/MGT Hybrid System

  • Kim, Jae-Hwan;Suzuki, Kenjiro
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.703-707
    • /
    • 2001
  • A performance analysis of a SOFC/MGT hybrid system has been carried out for concept design. Thermo-dynamic models for each component being able to describe electrochemical characteristics and heat and mate-rial balance are proposed. Estimated is the power capacity of a SOFC suitable for the hybrid operation with a 5kW class MGT. Effects of current density and operating pressure are also investigated. Electric efficiency showed weak dependence on operating pressure and current density. It is desirable that the SOFC operates at high current density in manufacturing cost's point of view though operating with high current density slightly decreases the electric efficiency find specific power.

  • PDF