• Title/Summary/Keyword: Micro-current

Search Result 1,178, Processing Time 0.038 seconds

Iontophoretic Delivery of Levodopa: Permeation Enhancement by Oleic Acid Microemulsion and Ethanol (Levodopa의 이온토포레시스 경피전달: 올레인산 아이크로에멀젼 및 에탄올의 투과증진)

  • Jung, Shin-Ae;Gwak, Hye-Sun;Chun, In-Koo;Oh, Seaung-Youl
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.6
    • /
    • pp.373-380
    • /
    • 2008
  • In order to develop optimal formulation and iontophoresis condition for the transdermal delivery of levodopa, we have evaluated the effect of two permeation enhancers, ethanol and oleic acid in microemulsion, on transdermal delivery of levodopa. In vitro flux studies were performed at $33^{\circ}C$, using side-by-side diffusion cell and full thickness hairless mouse skin. Current density applied was $0.4\;mA/cm^2$ and current was off after 6 hours application. Levodopa was analysed by HPLC at 280 nm. The o/w microemulsions of oleic acid in buffer solution (pH 2.5 & 4.5) were prepared using oleic acid, Tween 80 and ethanol. The existence of microemulsion regions were investigated in pseudo-ternary phase diagrams. Contrary to our expectation, cumulative amount of levodopa transported from microemulsion (pH 2.5) for 10 hours was similar to that from aqueous solution in all delivery methods (passive, anodal and cathodal). When pH of the micro-emulsion was pH 4.5, cumulative amount of levodopa transported for 10 hours increased about 40% (anodal) to 50% (cathodal), when compared to that from aqueous solution. Flux from pH 4.5 microemulsion showed higher value than that from pH 2.5 in all delivery methods. These results seem to indicate that electroosmosis plays more dominant role than electrorepulsion in the flux of levodopa at pH 2.5. The effect of ethanol on iontophoretic flux was studied using pH 2.5 phosphate buffer solution containing 3% or 5% (v/v) ethanol. Flux enhancement was observed in passive and anodal delivery as the concentration of the ethanol increased. Without ethanol, cathodal delivery showed higher flux than anodal delivery. Anodal delivery increased the cumulative amount of levodopa transported 1.6 fold by 5% ethanol after 10 hours. However, in cathodal delivery, no flux enhancement of levodopa was observed during current application and only marginal increase in cumulative amount transported after 10 hours was observed by 5% ethanol. These results seem to be related to the decrease in dielectric constant of the medium and the lipid extraction of the ethanol, which decrease the electroosmotic flow, and thus decrease the flux. Overall, the results provide important insights into the role of electroosmosis and electrorepulsion in the transport of levodopa through skin, and provide some useful informations for optimal formulation for levodopa.

Coolant Leak Effect on Polymer Electrolyte Membrane Fuel Cell (고분자전해질연료전지의 냉각수 누설에 대한 연구)

  • Song, Hyun-Do;Kang, Jung-Tak;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.4
    • /
    • pp.301-305
    • /
    • 2007
  • The performance of polymer electrolyte membrane fuel cell could be decreased due to coolant leaked from connection part. Micro pump was used to put small amount of coolant and investigate the effect on fuel cell. The stoichiometric ratio of hydrogen/air was 1.5/2.0, both side of gas was fully humidified, and current density of $400mA/cm^2$ was used as standard condition in this experiment. Constant current method was used to check performance recovery from coolant effect in 3 cell stack. The performance was recovered when coolant was injected in cathode side. On the other hand, the performance was not recovered when coolant was injected in anode side. Ethylene glycol could be converted to CO in oxidation process and cause poisoning effect on platinum catalyst or be adhered on GDL and cause gas diffusion block effect resulting performance decrease. Water with nitrogen gas was supplied in anode side to check performance recovery. Polarization curve, cyclic voltammetry, electrochemical impedance spectroscopy was used to check performance, and gas chromatography was used to check coolant concentration. Constant current method was not enough in full recovery of performance. However, water injection method was proved good method in full recovery of performance.

Corrosion Behaviors of Dental Implant Alloy after Micro-sized Surface Modification in Electrolytes Containing Mn Ion

  • Kang, Jung-In;Son, Mee-Kyoung;Choe, Han-Cheol
    • Journal of Korean Dental Science
    • /
    • v.11 no.2
    • /
    • pp.71-81
    • /
    • 2018
  • Purpose: The purpose of this study was to investigate the corrosion behaviors of dental implant alloy after microsized surface modification in electrolytes containing Mn ion. Materials and Methods: $Mn-TiO_2$ coatings were prepared on the Ti-6Al-4V alloy for dental implants using a plasma electrolytic oxidation (PEO) method carried out in electrolytes containing different concentrations of Mn, namely, 0%, 5%, and 20%. Potentiodynamic method was employed to examine the corrosion behaviors, and the alternatingcurrent (AC) impedance behaviors were examined in 0.9% NaCl solution at $36.5^{\circ}C{\pm}1.0^{\circ}C$ using a potentiostat and an electrochemical impedance spectroscope. The potentiodynamic test was performed with a scanning rate of $1.667mV\;s^{-1}$ from -1,500 to 2,000 mV. A frequency range of $10^{-1}$ to $10^5Hz$ was used for the electrochemical impedance spectroscopy (EIS) measurements. The amplitude of the AC signal was 10 mV, and 5 points per decade were used. The morphology and structure of the samples were examined using field-emission scanning electron microscopy and thin-film X-ray diffraction. The elemental analysis was performed using energy-dispersive X-ray spectroscopy. Result: The PEO-treated surface exhibited an irregular pore shape, and the pore size and number of the pores increased with an increase in the Mn concentration. For the PEO-treated surface, a higher corrosion current density ($I_{corr}$) and a lower corrosion potential ($E_{corr}$) was obtained as compared to that of the bulk surface. However, the current density in the passive regions ($I_{pass}$) was found to be more stable for the PEO-treated surface than that of the bulk surface. As the Mn concentration increased, the capacitance values of the outer porous layer and the barrier layer decreased, and the polarization resistance of the barrier layers increased. In the case of the Mn/Ca-P coatings, the corroded surface was found to be covered with corrosion products. Conclusion: It is confirmed that corrosion resistance and polarization resistance of PEO-treated alloy increased as Mn content increased, and PEO-treated surface showed lower current density in the passive region.

Changes in Emissions of Highway Sections according to the GHG Reduction Target (온실가스 감축목표에 따른 고속도로 구간 배출량 변화 연구)

  • Choi, Seonghun;Chang, Hyunho;Yoon, Byungjo
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.4
    • /
    • pp.849-856
    • /
    • 2020
  • Purpose: Greenhouse gases are one of the major causes of global warming, a global disaster. It aims to improve how effective the GHG reduction policy, which is the main cause of global warming in the transportation sector, has been effective on the highway and how to calculate GHG emissions. Method: Using the DSRC raw data, we estimate the emissions of Namhae Expressway (Yeongam-Suncheon) from 2017 to 2019 in two ways, a macro method (conventional) and a micro method (individual vehicle). Result: As a result of calculating the emission of the highway, the result was far exceeding the estimated emission, and it was found that when the calculation was performed for each vehicle, it was underestimated by more than 20%. Conclusion: If more emissions are continuously emitted than expected in the current transportation sector, additional emission reduction policies are needed to achieve the current greenhouse gas reduction targets. In addition, in the calculation of emissions, which is the basis of this policy, analysis was conducted for each individual vehicle using the current DSRC raw data, but using GPS afterwards will enable precise emission calculation through a more microscopic analysis.

Risk Analysis of Household Debt in Korea: Using Micro CB Data (개인CB 자료를 이용한 우리나라 가계의 부채상환위험 분석)

  • Hahm, Joon-Ho;Kim, Jung In;Lee, Young Sook
    • KDI Journal of Economic Policy
    • /
    • v.32 no.4
    • /
    • pp.1-34
    • /
    • 2010
  • We conduct a comprehensive risk analysis of household debt in Korea for the first time using the whole sample credit bureau (CB) data of 2.2 million individual debtors. After analysing debt service capacity profiles of debtor groups classified by the borrower characteristics such as income, age, occupation, credit scoring, and the type of creditor business companies, we investigate the impact of interest rate and income changes on debt service-to-income ratios (DTIs) and default rates of respective debtor groups. Empirical results indicate that debt service burdens are relatively high for low income wage earners, high income self-employed, low income capital and card loan holders, and high income mutual savings loan holders. We also find that debtors from multiple financial companies are particularly weak in their debt service capacity. The scenario analysis indicates that financial companies, with the current level of capital buffers, may be able to absorb negative consequences arising from the increase in DTIs and loan default rates if the interest rate and income changes remain modest. However, the negative consequences may fall disproportionately on non-bank financial companies such as capital, credit card, and mutual savings banks, whose debtors' DTIs are already high. We also find that the refinancing risk of household debt is relatively high in Korea as more than half of household mortgage debts are bullet loans. As the DTIs of mortgage loan holders are already high, under the current DTI regulation, mortgage loans may not be readily refinanced especially when the interest rate rises. Disruptions in mortgage loan refinancing may put downward pressure on housing prices, which may in turn magnify refinancing risk under the current loan-to-value (LTV) regulation. Overall our analysis suggests that, for more effective monitoring of household debt risk, it is necessary to combine existing surveillance schemes based on macro aggregate indicators with more comprehensive and detailed risk analyses based on micro individual data.

  • PDF

A Study on Development of Market Oriented MIS Curriculum (시장지향적 MIS 교육과정 개편을 위한 연구)

  • Lee, Ji-Myoun;Bock, Gee-Woo
    • Information Systems Review
    • /
    • v.10 no.3
    • /
    • pp.207-222
    • /
    • 2008
  • In recent business environment, we realize that MIS is taking important role in which it has been involved. However, we are having difficulty to find out the identity of MIS in business studies since MIS is derived from Micro Economics, Operations Research, Computer Science and so on. And there is no clear boundary in order to classify with other business area in consisting curriculums. Furthermore, IT staffs in the field are facing difficulties to utilize what they have learned MIS curriculums provided from business studies. In this research, we would like to present implications for development of market oriented MIS curriculums, which can be the actual needs of IT fields, through analysis of System Integration project for recent three years, analysis of IT capability based on the survey of IT consultants and analysis of application S/W technology trend in global vendor referred to "MIS Curriculum: The Current State of the Art and a Proposed Future Model (Lee et al, 2007)". As enterprise application software technology develop, the system integration can be achieved through special system solutions such as ERP, CRM, SCM, BI, etc. We also have acknowledged that solution consultants who have the ability of packaged S/W application are in demand since S/W vendors have become larger and more practical through M&A. Therefore, we have come to a conclusion regarding new direction of curriculum for increasing human power in IT industry which we demonstrated in detail through this research.

Design and Implementation of Low-power Neuromodulation S/W based on MSP430 (MSP430 기반 저전력 뇌 신경자극기 S/W 설계 및 구현)

  • Hong, Sangpyo;Quan, Cheng-Hao;Shim, Hyun-Min;Lee, Sangmin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.7
    • /
    • pp.110-120
    • /
    • 2016
  • A power-efficient neuromodulator is needed for implantable systems. In spite of their stimulation signal's simplicity of wave shape and waiting time of MCU(micro controller unit) much longer than execution time, there is no consideration for low-power design. In this paper, we propose a novel of low-power algorithm based on the characteristics of stimulation signals. Then, we designed and implement a neuromodulation software that we call NMS(neuro modulation simulation). In order to implement low-power algorithm, first, we analyze running time of every function in existing NMS. Then, we calculate execution time and waiting time for these functions. Subsequently, we estimate the transition time between active mode (AM) and low-power mode (LPM). By using these results, we redesign the architecture of NMS in the proposed low-power algorithm: a stimulation signal divided into a number of segments by using characteristics of the signal from which AM or LPM segments are defined for determining the MCU power reduces to turn off or not. Our experimental results indicate that NMS with low-power algorithm reducing current consumption of MCU by 76.31 percent compared to NMS without low-power algorithm.

The Design and Construction of the Nuclear Microprobe (핵 마이크로프로브 설계 및 제작)

  • Woo, Hyung-Ju;Kim, Jun-Gon;Choi, Han-Woo;Hong, Wan;Kim, Young-Seok;Lee, Jin-Ho;Kim, Ki-Dong;Yang, Tae-Gun
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.3
    • /
    • pp.380-386
    • /
    • 2001
  • A nuclear microprobe system with adjustable precision object slits and a magnetic quadrupole doublet was designed by the beam optics simulation using a first order matrix formalism, and installed in a $30^{\circ}$ beam line connected with KIGAM 1.7 MV Tandem VDG Accelerator. Demagnification factors for x and y axis are calculated to be 25 and 4.9, respectively, and a minimum beam spot side is expected to be about 5 $\mu\textrm{m}$ for 3 MeV proton beams with a current of about 1 nA. A multi-purpose octagonal target chamber has been built to facilitate MeV ion-beam analytical techniques of PIXE, RBS, ERDA, and ion beam micro-machining. It contains X-ray and particle detectors, a zoom microscope, a Faraday cup, a 4-axis sample manipulator and a high vacuum pumping system. The system performance of the nuclear microprobe is now being tested, and automatic manipulator control and data acquisition system will be installed for routine applications of micro ion-beam analytical techniques.

  • PDF

Morphology of RF-sputtered Mn-Coatings for Ti-29Nb-xHf Alloys after Micro-Pore Form by PEO

  • Park, Min-Gyu;Park, Seon-Yeong;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.197-197
    • /
    • 2016
  • Commercially pure titanium (CP Ti) and Ti-6Al-4V alloys have been widely used for biomedical applications. However, the use of the Ti-6Al-4V alloy in biomaterial is then a subject of controversy because aluminum ions and vanadium oxide have potential detrimental influence on the human body due to vanadium and aluminum. Hence, recent works showed that the synthesis of new Ti-based alloys for implant application involves more biocompatible metallic alloying element, such as, Nb, Hf, Zr and Mo. In particular, Nb and Hf are one of the most effective Ti ${\beta}-stabilizer$ and reducing the elastic modulus. Plasma electrolyte oxidation (PEO) is known as excellent method in the biocompatibility of biomaterial due to quickly coating time and controlled coating condition. The anodized oxide layer and diameter modulation of Ti alloys can be obtained function of improvement of cell adhesion. Manganese(Mn) plays very important roles in essential for normal growth and metabolism of skeletal tissue in vertebrates and can be detected as minor constituents in teeth and bone. Radio frequency(RF) magnetron sputtering in the various PVD methods has high deposition rates, high-purity films, extremely high adhesion of films, and excellent uniform layers for depositing a wide range of materials, including metals, alloys and ceramics like a hydroxyapatite. The aim of this study is to research the Mn coatings on the micro-pore formed Ti-29Nb-xHf alloys by RF-magnetron sputtering for dental applications. Ti-29Nb-xHf (x= 0, 3, 7 and 15wt%, mass fraction) alloys were prepared Ti-29Nb-xHf alloys of containing Hf up from 0 wt% to 15 wt% were melted by using a vacuum furnace. Ti-29Nb-xHf alloys were homogenized for 2 hr at $1050^{\circ}C$. Each alloy was anodized in solution containing typically 0.15 M calcium acetate monohydrate + 0.02 M calcium glycerophosphate at room temperature. A direct current power source was used for the process of anodization. Anodized alloys was prepared using 270V~300V anodization voltage at room. Mn coatings was produced by RF-magnetron sputtering system. RF power of 100W was applied to the target for 1h at room temperature. The microstructure, phase and composition of Mn coated oxide surface of Ti-29Nb-xHf alloys were examined by FE-SEM, EDS, and XRD.

  • PDF

Comparison between the Road-based and the Parcel-based Address Coordinates for Urban Air Pollution Estimation - A Case Study of Yeongdeungpo-gu, Seoul, Korea - (도심대기오염추정을 위한 도로명주소좌표와 지번주소좌표의 비교 - 서울 영등포 지역의 사례연구 -)

  • Park, Jinwoo;Choi, Jinmu;Hong, Seong-Yun
    • Journal of Cadastre & Land InformatiX
    • /
    • v.46 no.2
    • /
    • pp.169-181
    • /
    • 2016
  • The address system in Korea was changed to the road-based system in 2014, but the current address coordinates are still largely based on the old, parcel-based system. Compared to the parcel-based address system that defines the center of a parcel as its coordinates, the road-based system locates the coordinates at a certain distance away from the road on which the parcel fronts. The difference in coordinates between these two systems is small, but it can be crucial for micro-level modelling. In order to assess the impact of the discrepancy between the two address systems, this study measured the degree of air pollution exposure at two different locations, the road-based address coordinates and the parcel-based address coordinates, for each of 252 buildings in Yeongdeungpo-gu, Seoul. The air pollution values were estimated using a microscopic air pollution dispersion model, CALINE4, and t-tests and F-tests were conducted to evaluate statistical significance on the observed difference. The results showed a considerable difference in the level of air pollution exposure between the two address systems, suggesting that the on-going use of the parcel-based address coordinates could cause potentially significant errors in micro-level analysis.