• 제목/요약/키워드: Micro-actuator

검색결과 413건 처리시간 0.027초

능동 진동제어용 전자기 액츄에이터 설계 (A Design of Electromagnet Actuator for Active Vibration Control)

  • 이주훈;전정우;황돈하;강동식;최영규
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.522-524
    • /
    • 2005
  • In this paper, we address an actuator system, which suppresses the micro-vibration engaged by environment. The actuator system consists of two modules with a permanent and an electromagnet. In vertical mode, one module is upper the other is lower. For optimal control of alternating vibration, the rate of the attraction force and the repulsion force is exactly one. Generally, the repulsive force is smaller than the attractive force. For linear control of engaged vibration, the ratio of repulsive force and attractive force is designed to equal. The actuator system will be applied to an active vibration control system for precise vibration suppression. In this paper, the actuator structure and its important sizes are calculated by RMS and FEM analysis.

  • PDF

미세 골조직의 공극탄성계수 측정을 위한 예비 연구 (A Pilot study of poroelastic modulus measurement in micro-bone tissue)

  • 박영환;홍정화
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1038-1041
    • /
    • 2004
  • In this study, developed a micro-level experimental setup to measure pore pressure and poroelastic modulus in various strain and strain rate about a stress in micro-structure of bone tissue. It is essential device in the development of the model to analysis the interstitial bone fluid flow of the lacuno-canalicular system to be known that would effect on the bone remodeling. The constitution of the experimental setup is as follows, microscopic image processing system; actuator control unit; load measurement system. A pilot study was used an artificial chemical wood to have similar poroelastic property of bone matrix and conducted to validate the suitability of the measurement system.

  • PDF

이중서보제어루프를 통한 서보모터-압전구동기의 초정밀위치결정 시스템 (Ultra precision positioning system for Servo Motor-Piezo actualtor using dual servo loop)

  • 이동성;박종호;박희재
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.437-441
    • /
    • 1995
  • In this paper, the ultra precision positioning system for servo motor and piezo actuator using dual servo loop control has been developed. For positioning system having long distance with ultra precision, the combination of global stage and micro stage is required. Servo moter and ball screw are used as a master stage and piezo acuator as a fine stage. By using this system, an positional precision witin .+-. 30nm has been achieved at dual servo loop control. When using micro stage, an positional precision within .+-. 10nm has been achieved. This result can be applied to develop semiconductor equipment such as wafer stepper.

  • PDF

유체 진동자의 최적 설계 (Optimum Design of a Micro-fluidic Oscillator)

  • 노유정;윤성기;김문언
    • 대한기계학회논문집A
    • /
    • 제28권1호
    • /
    • pp.22-30
    • /
    • 2004
  • A micro-fluidic oscillator is used to control a linear actuator in a dynamic microsystem. The pressure difference at its two output ports causes the linear actuator to move, and it is a standard of judging the performance of the oscillator. The performance can be improved by optimizing the geometry of the oscillator, which has to enable fluid jet to switch at low inlet velocity. For this, in this study the relationship between the pressure coefficient (difference) and geometric parameters is obtained through the analysis using the software FLUENT. From the results the optimized model that maximize the output pressure difference is obtained by using a cyclic coordinate method that is one of optimization methods. As a result not only the performance is improved, but also the working range is more widen.

모터를 이용한 바퀴형 체내이동 메커니즘의 개발 (Development of a Wheel Type Locomotive Mechanism Using Micro motor for a Capsule-Type Endoscope)

  • 이영재;김병규;임영모;박종오;홍예선;김수현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집B
    • /
    • pp.289-294
    • /
    • 2001
  • The two prototypes of a Wheel Type Locomotive Mechanism Using Micro motor for a Capsule-Type Endoscope are outlined and realized. Basic concept of these mechanisms is to use a rod-shaped wheel, with which these mechanisms can go over the haustral folds inside colon. The actuator of Prototype I is geared dc motor and the actuator for steering is Shape Memory Alloy. Prototype I goes through the whole area of colonoscopy training model. Prototype II can not only go forward and backward, but also be steerable with 2 geared dc motors. Prototype II goes through dead pig colon.

  • PDF

열 보조 자기기록용 광 전달 레이저 모듈의 설계 및 평가 (Design and evaluation of laser module for light delivery in heat assisted magnetic recording)

  • 최용복;이문호;김영주
    • 정보저장시스템학회논문집
    • /
    • 제7권1호
    • /
    • pp.36-41
    • /
    • 2011
  • The micro laser module was designed and prepared to deliver the light to the HAMR head. It consists of laser diode, photo diode and actuator to realize stable light delivery even though the head is fluctuated during the disk rotation. The optical evaluation was carried out with the actual distance between the light source and HAMR head with a range of reflectivity and it was found that the incident angle could be controlled within ${\pm}0.125^{\circ}$ to maintain same intensity into the HAMR head. It was also confirmed that the designed micro laser module is thermally stable without any severe effect on the magnetic head.

직립보행로봇 Actuator 개발에 관한 연구 (A study on Development of Actuator for Biped Walking Robot)

  • 문진수;김철우
    • 조명전기설비학회논문지
    • /
    • 제19권7호
    • /
    • pp.73-80
    • /
    • 2005
  • 직립보행로봇은 동적인 시스템 구현을 위해 에너지원과 제어장치부가 로봇에 탑재되어야 한다. 때문에 본 연구에서는 소형에서 높은 기동 토크를 얻을 수 있는 직류전동기를 선택하였다. 직류전동기 서보시스템에는 아날로그 처리방식의 파워앰프를 이용하여, 제어기와 구동기가 일체화된 하나의 모들로 개발하였다. 이를 로봇액추에이터에 적용하고 동작과 복귀시의 응답특성을 연구하였다. 주 제어부는 PIC(Micro controller)를 채용하여 서보시스템과 함께 소형경량으로 로봇에 탑재할 수 있다.

BLDC 모터를 이용한 고기동 추력기용 밸브 구동장치 제어기 개발 (Development of BLDC Motor Valve Actuator Controller for Rapid Maneuvering Thruster)

  • 이정운;장희진;박치형;박상준;장기원
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2011년도 제37회 추계학술대회논문집
    • /
    • pp.929-932
    • /
    • 2011
  • 추력기 시스템에 적용되는 밸브 구동장치용 제어기를 개발하였다. 추력기 시스템은 총 4개의 구동장치로 구성되어 있으며, 구동장치는 BLDC 모터를 적용하였다. 제어기는 구동장치 운용 조건과 제어 요건을 고려하여 설계 및 제작 되었다. 제어기 구성은 전원부, 제어부, 증폭부의 3부분으로 구성된다. 제어부의 Micro-controller는 TI사(社)의 TMS320F28335를 사용하여 Digital PID 제어 및 CAN 통신을 구현 하였다. 증폭부는 IGBT를 사용하여 3상 BLDC 모터의 구동을 수행 하였다.

  • PDF

미세동작제어를 위한 자기유변유체 구동기의 동적 특성 (Dynamic Characteristics of Magneto-rheological Fluid Actuator for Micro-motion Control)

  • 김평화;한철희;칼루반 수레쉬;박춘용;신철수;최승복
    • 한국소음진동공학회논문집
    • /
    • 제26권5호
    • /
    • pp.511-517
    • /
    • 2016
  • This paper presents dynamic characteristics of a new actuator using magneto-rheological(MR) fluid between two electrode type coils. The concept of the actuator is to strengthen the force due to the magnetic field produced by the electrode-coil for MR fluid. The amount and direction of current input to the electrode-coils decide the characteristics of contraction-mode and extension-mode. For achieving the required actuating displacement and actuating force, the yield stress of the MR fluid between two electrode-coils is precisely changed by the input current. In this work, the MR fluid is operated in squeeze mode. The experimental results shown in this paper depict that it can be applied in the micro-level displacement and vibration control system.

Design of a VCM actuator for dual servo system

  • Choi, Hyeun-Seok;Han, Chang-Soo;Kim, Seung-Soo;Kim, Eung-Zu;Choi, Tae-Hoon;Na, Kyoung-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.301-306
    • /
    • 2004
  • In this study, Dual servo mechanism with VCM(Voice Coil Motor) and PZT is designed for a high precision force and position control. We designed the VCM actuator and dual servo mechanism with leaf spring. VCM actuators, with their high linearity, simple structure, low weight, and high efficiency, are increasingly being used in micro-positioning applications. There are many kinds of VCM with a structure. VCM actuators are divided into two types by moving parts. One is moving magnet type and the other moving coil type. We described the properties of these two types of VCM. Design parameters of VCM are defined through the FEM simulation analysis of magnetic field and dynamic model of dual servo mechanism. These researches help to for decreasing loss in the air gap of VCM. We present dual servo mechanism is effective mechanism for a force control in hi h precision, properties of designed VCM.

  • PDF