• 제목/요약/키워드: Micro-Screw

검색결과 60건 처리시간 0.025초

Precise contact force control of a flip chip mounting head system

  • Shim, Jaehong;Cho, Youngim;Oh, Yeontaek
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.109.1-109
    • /
    • 2002
  • This paper presents a macro/micro flip chip mounting head system for precise force control. In the proposed macro/ micro system, the macro actuator is conventional do servomotor with a ball screw mechanism and the micro actuator is a voice coil motor(VCM) that consists of four NdFeB magnets and a winded moving coil. For force control, a sensitive strain-gauge force sensor is mounted in the micro actuator. Through harmonic motion between macro and micro actuator, we would like to get precise contact force control when small sized flip chip is mounted on flexible substrate in high speed. In order to show the effectiveness of the proposed macro/micro flip chip mounting head system, we com...

  • PDF

High Lead Ball Screw를 사용한 고속이송계의 특성 (The Characteristics of High Speed Feed Drive System using High Lean Screw)

  • 고해주;박성호;정윤교
    • 한국공작기계학회논문집
    • /
    • 제10권4호
    • /
    • pp.97-103
    • /
    • 2001
  • The study on the high-speed machine tool is very important for the improvement of productivity since it can shortens cutting and non-cutting time. Especially, high speed of feed drive system is the major research field. In the industries of the advanced countries, the feed drive systems at the speed of 60 m/min have been already developed based on the high lead ball screws. In this study, a high speed feed drive system at the speed of 60 m/ min has been developed, and its movements characteris-tics are investigated. As the movement characteristics, positioning accuracy, angular accuracy, straightness and micro step-response are measured. Thermal characteristics of the system is also discussed. For measuring the movement characteris-tics, a laser interferometer, a memory-based Hi-coder and a cooling device are used. The experimental results confirm that the movement characteristics and the thermal behavior of the system are satisfactory in the aspect of accuracy and stability.

  • PDF

포토 마이크로 센서를 이용한 볼나사 구동 리니어 스테이지의 위치결정 실험 (A Position Decision Experiment in Ball-screw Driven Linear Stage using a Photomicrosensor)

  • 차영엽
    • 제어로봇시스템학회논문지
    • /
    • 제20권4호
    • /
    • pp.463-467
    • /
    • 2014
  • High precision machining technology has become one of the most important parts in the development of a precision machine. Such a machine requires high precision positioning as well as high speed on a large workspace. For machining systems having high precision positioning with a long stroke, it is necessary to examine the repeatability of the reference position decision. Though ball-screw driven linear stages equipped with linear scale have high precision feed drivers and a long stroke, they have some limitations for reference position decisions if they have not been equipped with an accurate home sensor. This study is performed to experimentally examine the repeatability for home position decision of a photo micro sensor as a home switch of a ball-screw driven linear stage by using a capacitance probe.

Surface Mounting Device의 동역학적 모델링 및 상태 민감도 해석 (A Dynamic Modeling & State Sensitivity Analysis of the Surface Mounting Device)

  • 장진희;한창수;김정덕
    • 한국정밀공학회지
    • /
    • 제13권7호
    • /
    • pp.90-99
    • /
    • 1996
  • In the area of assembly process of micro-chips and electronic parts on the printed circuit board, surface mounting device(SMD) is used as a fundamental tool. Generally speaking, the motion of the SMD is based on the ball screw system operated by any type of actuators. The ball screw system is a mechanical transformed which converts the mechanical rotational motion to the translational one. Also, this system could be considered as an efficient motion device against mechanical backlash and friction. Therefore a dynamic modeling and state sensitivity analysis of the ball screw system in SMD have to be done in the initial design stage. In this paper, a simple mathematical dynamic model for this system and the sensit- ivity analysis are mentioned. Especially, the bond graph approach is used for graphical modeling of the dynamic system before analysis stage. And the direct differentiation method is used for the state sensit- ivity analysis of the system. Finally, some trends for the state variables with respect to the design variables could be suggested for the better design and faster operating based on the results of dynamic and state sensitivity.

  • PDF

마이크로 펀칭시스템 구현을 위한 심벌변위확대기구의 설계 (Design of Cymbal Displacement Amplification Device for Micro Punching System)

  • 최종필;이광호;이해진;이낙규;김성욱;주은덕;김병희
    • 한국공작기계학회논문집
    • /
    • 제18권1호
    • /
    • pp.36-41
    • /
    • 2009
  • This paper presents the development of a micro punching system with modified cymbal mechanism. To realize the micro punching, we introduced the hybrid system with a macro moving part and micro punching part. The macro moving part consists of a ball screw, a linear guide and the micro step motor and micro punching part includes the PZT actuators and displacement amplification device with modified cymbal mechanism. The PZT actuator is capable of producing very large force, but they provide only limited displacements which are several micro meters. Thus the displacement amplification device is necessary to make those actuators more efficient and useful. For this purpose, a cymbal mechanism in series is proposed. The finite element method was used to design the cymbal mechanism and to analyze the mode shape of the one. The displacement and mode shape error between the FEM results and experiments are within 10%. A considerable design effort has been focused on optimizing the flexure hinge to increase the output displacement and punching force.

척추극돌간 미세움직임 재현 보형물의 개발 및 평가 (Development and Evaluation for the Micro-Movement Structure of Interspinous)

  • 박준식;서태일;배종석;윤길상
    • 한국공작기계학회논문집
    • /
    • 제15권3호
    • /
    • pp.127-131
    • /
    • 2006
  • Existing orthopedic implants such as pedicle screw and spinal cage were designed to fix the spinal structure. But, nowadays, physicians want to rehabilitate there original functions. To achieve this request, we studied micro-movable structure for interspinous. As a first step, we designed interspinous structure by 3D CAD to join each spinous processes. Next, we simulate it with various factors such as the thickness of micro-movement structure and the design of clip. At last, we performed static compressive test to satisfy the failure load of 339N and dynamic endurance test of 1.2M cycle. As a result, we developed interspinous implant and did several surgery to evaluated its satisfaction.

Hydroxyapatite를 이식한 임플란트 주위 골결손부에서 rhPDGF-BB와 rhBMP-2가 골내 임플란트 osseointegration에 미치는 영향: Micro-CT 분석과 조직학적 평가 (EFFECT OF RHPDGF-BB AND RHBMP-2 ON OSSEOINTEGRATION OF TITANIUM IMPLANTS AT PERIIMPLANT BONE DEFECTS GRAFTED WITH HYDROXYAPATITE: MICRO-CT AND HISTOLOGIC ANALYSIS)

  • 박지현;황순정;김명진
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권6호
    • /
    • pp.461-468
    • /
    • 2009
  • Purpose: Platelet derived growth factor(PDGF)-BB and bone morphogenetic protein(BMP)-2 are well-known representative growth factors. The purposes of this study were to investigate the effect of rhPDGFBB and rhBMP-2 on osseointegration of titanium implants at periimplant bone defects grafted with hydroxyapatite and to evaluate the feasibility of imaging bone structures around screw-type titanium implant with micro-CT. Materials and Methods: The first molar and all premolars in the mandible region of four beagle dogs were extracted. Following a healing period of 4 months, three $8{\times}8{\times}6mm$-sized bony defects were formed and screw-type titanium implants were placed with hydroxyapatite(HA) block and growth factors; Control group, PDGF group and BMP group. Two months post-implantation, the mandible was harvested. Bone volume(BV), bone-to-implant contact(BIC) and bone mineral density(BMD) were analyzed with micro-CT and histology. Results: According to micro-CT analysis, BV and BMD measures of PDGF and BMP group were significantly higher than control group(BV; PDGF group: $p{\fallingdotseq}0.011$, BMP group: $p{\fallingdotseq}0.006$/BMD; PDGF group: $p{\fallingdotseq}0.020$, BMP group: $p{\fallingdotseq}0.011$) and BIC measures of BMP group were significantly higher than PDGF group($p{\fallingdotseq}0.015$). In histologic evaluation, BIC measures of BMP group was significantly higher than PDGF group($p{\fallingdotseq}0.048$). The values of BV in histologic sections were higher than in micro-CT images and the values of BIC in micro-CT images were higher than in histologic sections. Conclusion: The findings of this experimental study indicates that the use of rhPDGF-BB and rhBMP-2 can increase new bone formation in a large bony defect around titanium implant, and rhBMP-2 is more effective than rhPDGF-BB. Micro-CT can be considered useful for assessment as a rapid and nondestructive method for 3-dimensional measurement of bone healing around implants. Further study is necessary, however, to remove metal artifacts around titanium implant and to standardize the method.

고속 압출 전처리 공정을 이용한 Chlorella sp. 당화 및 바이오에탄올 생산 (Saccharification and Ethanol Production from Chlorella sp. Through High Speed Extrusion Pretreatment)

  • 이춘근;최운용;서용창;송치호;안주희;정경환;이상은;강도형;이현용
    • KSBB Journal
    • /
    • 제27권3호
    • /
    • pp.137-144
    • /
    • 2012
  • Among various pretreatment processes for bioethanol production, extrusion pretreatment, one of cheap and simple process was investigated to efficiently produce fermentable sugars from micro alga, Chlorella sp. The biomass was pretreated in a single screw extruder at five different barrel temperatures of 45, 50, 55, 60 and $65^{\circ}C$, respectively with five screw rotation speed of 10, 50, 100, 150 and 200 rpm. The pretreated biomass was reacted with two different hydrolyzing enzymes of cellulase and amyloglucosidase since the biomass contained different types of carbohydrates, compared to cellulose of agricultural by-products such wheat and corn stovers, etc. In general, higher glucose conversion yield was obtained as 13.24 (%, w/w) at $55^{\circ}C$ of barrel temperature and 100 rpm of screw speed conditions. In treating 5 FPU/glucan of cellulase and 150 Unit/mL of amyloglucosidase, ca. 64% of cellulose and 40% of polysaccharides in the micro alga were converted into glucose, which was higher yields than those from other reported data without applying an extrusion process. 84% of the fermentable sugars obtained from the hyrolyzing processes were fermented into ethanol in considering 50% of theoretical maximum fermentation yield of the yeast. These results implied that high speed extrusion could be suitable as a pretreatment process for the production of bioethanol from Chlorella sp.

Skeletal Anchorage System의 식립을 위한 한국인 악골의 피질골 두께에 대한 연구 (STUDY OF MAXILLARY CORTICAL BONE THICKNESS FOR SKELETAL ANCHORAGE SYSTEM IN KOREAN)

  • 김지혁;주재용;박영욱;차봉근;김성민
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제28권4호
    • /
    • pp.249-255
    • /
    • 2002
  • Recently, Skeletal Anchorage System (SAS) has been focused clinically with the view point that it could provide the absolute intraoral anchorage. First, it began to be used for the patient of orthognathic surgery who had difficulty in taking intermaxillary fixation due to multiple loss of teeth. And then, its uses have been extended to many cases, the control of bone segments after orthognathic surgery, stable anchorage in orthodontic treatment, and anchorage for temporary prosthesis and so on. SAS has been developed as dental implants technique has been developed and also called in several names; mini-screw anchorage, micro-screw anchorage, mini-implant anchorage, micro-implant anchorage (MIA), and orthosystem implant etc. Now many clinicians use SAS, but the anatomical knowledges for the installed depth of intraosseous screws are totally dependent on general experiences. So we try to study for the cortical thickness of maxilla and mandible in Korean adults without any pathologic conditions with the use of Computed Tomography at the representative sites for the screw installation.