멀티톤/멀티채널의 FXLMS 알고리즘을 이용한 변압기 소음제어에 관한 연구 (A study of transformer noise control using multi-tone/multi-channel of filtered LMS algorithm)

  • 박우용;김성중;이부원;이종화;김봉기;이욱륜;이준신;안경덕;김영달
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.379-380
    • /
    • 2007
  • 본 연구에서는 대용량변압기의 주 소음원인 120[Hz]와 240{Hz] 및 360[Hz] 주파수에 대한 다중음을 다채널(4채널)의 FXLMS 알고리즘을 적용한 변압기 소음 감쇠시스템을 구축하고 현장실험을 통해 소음이 저감되는 것을 확인하였다.

  • PDF

배전원격관리를 위한 차세대 디지털 적산전력계 개발 (Development of ADWHM(Advanced Digital Watt-Hour Meter) for Remote Management of Distribution Systems)

  • 고윤석;윤상문;서성진;강태규
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권6호
    • /
    • pp.316-323
    • /
    • 2004
  • This paper develops an ADWHM(Advanced Digital Watt-Hour Meter) which integrates and implements the voltage management data record function and the load management data record function in the electronic watt-hour meter. ADWHM is developed based on PIC16F874 which is 8bit micro-controller of RISK type for the easy of programing and maintenance, and electronic power signal processing module is located at front of it to reduce the computing load of processor. Also, a 16kbyte EEPROM is used to record the voltage management data and load management data for a week as well as watt-hour data and USART communication mode is used to transfer data from ADWHM to PC. The accuracy of the voltage and unt measuring for ADWHM is verified by identifying the LCD display values of the ADWHM after the voltage signals of id levels from digital function generator is applied to PT(Potential Transformer) and CT(Current Transformer) output under state which it is separated from real power line. On the its basic functions such as watt-hour data recording function, voltage management data recording function and load management data recording function was verified by showing data for three days among the collected data to PC by RS232C communication from ADWHM which was connected to real power lines for a week.

몰드형 건식 계기용 변압기 제작을 위한 수지 충진 해석 연구 (Numerical Analysis of Resin Filling Process for a Molded Dry-type Potential Transformer)

  • 김무선;장동욱;김승모
    • 한국산학기술학회논문지
    • /
    • 제17권12호
    • /
    • pp.511-517
    • /
    • 2016
  • 철도 차량에 쓰이는 기존 유입식 형태의 계기용 변압기는 장치 내부에 절연유가 충진 된 형태이므로, 차량 운행 중에 내부 압력이 상승할 수 있는 가능성이 있으며. 그에 따른 폭발위험성이 존재한다. 따라서 폭발 방지를 위해 몰드형 건식 계기용 변압기를 개발 중에 있다. 몰드형 건식 계기용 변압기 개발시 주의 하여야 할 점은 몰드를 구성하는 절연용 에폭시 수지를 주입할 때 권선 코일이 감겨진 코어 주변에 기공이 없어야 한다는 것이다. 이는 몰드 내부의 기공에서 스파크 등의 발생 위험이 있기 때문이다. 몰드 내의 기공 발생 요인으로는, 수지 내에 미세 기공(micro void)이 잔재되어 있는 경우와, 성형 중 함침 구조물의 형태에 따라서 대형 기공(macro void)이 발생할 수 있는 점 등이다. 현재 개발 중인 코어는 변압기 성능 향상을 위해 중공(cavity)이 존재하는 형태이며 점도가 높은 에폭시 주입시 중공 내부에 대형 기공이 갇힐 위험이 있다. 따라서 이번 연구에서는, 몰드 내부에 발생할 수 있는 대형 기공의 형성 과정을 이해하고, 기공 형성 요인을 제거할 수 있는 방안으로, 개선된 성형 조건 적용시 기공 형성 결과를 확인하기 위해, 몰드 충진 과정을 VOF기법을 적용한 자유 표면 유동의 수치해석을 통하여 확인하였다.

WiMAX 응용을 위한 결합 공진기 기반의 PCB 내장형 평형신호 듀플렉서의 설계 (Design of PCB Embedded Balanced-to-unbalanced WiMax Duplexer Using Coupled LC Resonators)

  • 박주용;박종철;박재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1587_1588
    • /
    • 2009
  • In this paper, PCB embedded balanced-to-unbalamced duplexer using coupled LC resonator was introduced for low cost dualband WiMax front-end-module application. In order to obtain the function of bandpass filter and balun transformer, proposed duplexer was configured by using magnetically coupled LC resonator. Out-of-band suppression was enhanced by applying two m-Derived transform circuits to obtain transmission zeros at 2GHz and 4.8GHz. In order to reduce the size of embedded duplexer, BaSrTiO3 (BST) composite high Dk RCC film was applied to improve the capacitance density. This high Dk film provided the capacitance density of 12.2 pF/mm2. The simulation results shows that fabricated duplexer had an insertion loss of 2.9dB and 5.5dB and return loss of 15dB and 16dB for 2.5GHz~2.6GHz and 3.5GHz~3.6GHz, respectively. The maximum magnitude and phase imbalance were 0.01dB and 0.17dB, and 1degree and 2degree in its passband, respectively. The out-of-band suppression was observed approximately 29dB and 40dB below 1.9GHz and over 4.5GHz, respectively. It has a volume of 6 mm $\times$ 7 mm $\times$ 0.7 mm (height).

  • PDF

플라이백 컨버터를 이용한 인버터 직류링크 전압의 절연 궤환 (Isolated Feedback of Inverter DC-Link Voltage Using Flyback Converters)

  • 김경서
    • 전력전자학회논문지
    • /
    • 제23권4호
    • /
    • pp.281-285
    • /
    • 2018
  • An isolated feedback method for measuring the inverter DC-link voltage is proposed. This method provides a simple and economical solution to inverter control systems that use a flyback converter as a controller power supply. In the proposed method, data on the DC-link voltage are acquired when the primary side voltage appears on the secondary side of the flyback transformer, thereby eliminating the need to adopt an extra signal isolation method. To solve the non-synchronization problem between the flyback converter switching and main controller sampling, the external interrupt function of the micro-controller is used as a trigger signal for the A/D conversion.

Surface Mounting Device의 동역학적 모델링 및 상태 민감도 해석

  • 장진희;한창수;김정덕
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.628-634
    • /
    • 1995
  • In the area of assembly process of micro-chips and electronic parts on the printed circuit board, surface mounting device(SMD) is used as a fundamental tool. Generally speaking, the motion of the SMD is based on the ball screw system operated by any type of actuators. The ball screw system is a mechanical transformer which converts the mechanical rotational motion to the translational one. Also, this system could be considered as an efficient motion device against mechanical backash and friction. Therefore a dynamic modeling and stste sensitivity analysis of the ball screw system in SMD have to be done in the initial design stage. In this paper, a simple mathematical dynamic model for this system and the sensitivity snalysis are mentioned. Especially, the bond graph approach is used for graphical modeling of the dynamic system before analysis stage. And the direct differentiation method is used for the state sensitivity analysis of the system. Finally, some trends for the state variables with respect to the design variables could be suggested for the better design based on the results on the results of dynamic and state sensitivity.

  • PDF

고온고압 환경피로실험 오토클래이브 내부용 미소변위 측정장치 개발 (Development of Micro Displacement Extensometer for Environmental Fatigue Test in a High Temperature and High Pressure Autoclave)

  • 정일석;하각현;김태룡;전현익;김영신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.368-371
    • /
    • 2008
  • An extensometer system to measure strain and displacement of cylindrical fatigue specimen in a autoclave of high temperature and high pressure environment has been developed by KEPRI. The extensometer reads the displacement caused by fatigue loads at the target length of the specimen installed inside the autoclave. The performance of the extensometer were tested at 15MPa, $315^{\circ}C$ of a operating pressurized water reactor. Two LVDT's of magnet type were connected to the extensometer and used for converting the fatigue displacement to electronic signal. The device is being used for developing environmental fatigue curve of CF8M cast austenitic stainless steel (CASS) in the test condition of low cycle and low strain. This paper introduces the background and results of the development.

  • PDF

고속전철용 입력 AC/DC PWM 컨버터의 병령운전 (The Parallel Operation of AC to DC PWM Converters for a High Speed Railway Train)

  • 류홍제;우명호;김종수;임근희;원충연
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권4호
    • /
    • pp.272-281
    • /
    • 2000
  • This paper deals with the parallel operation of several numbers of PWM converters for a high speed railway train application. Several considerations are made to reduce the transformer interaction which can cause a current control problem in severe case. Also, in this paper, novel control strategy is proposed to achieve a harmonic free primary-side current control under a light load condition using one current sensor independent of the number of converters. In addition, the modified predictive current controller, which is suitable to a digital current controller with a relatively large sampling period, is used. Finally, to verify the system validity, digital control system with TMS320C44 micro-processor and small scale simulator are made and tested.

  • PDF

A Simple Prediction Model for PCC Voltage Variation Due to Active Power Fluctuation of a Grid Connected Wind Turbine

  • Kim, Sang-Jin;Seong, Se-Jin
    • Journal of Power Electronics
    • /
    • 제9권1호
    • /
    • pp.85-92
    • /
    • 2009
  • This paper studies the method to predict voltage variation that can be presented in the case of operating a small-sized wind turbine in grid connection to the isolated small-sized power system. In order to do this, it makes up the simplified simulation model of the existing power plant connected to the isolated system, load, transformer, and wind turbine on the basis of PSCAD/EMTDC and compares them with the operating characteristics of the actual established wind turbine. In particular, it suggests a simplified model formed with equivalent impedance of the power system network including the load to analytically predict voltage variation at the connected point. It also confirms that the voltage variation amount calculated by the suggested method accords well with both simulation and actually measured data. The results can be utilized as a tool to ensure security and reliability in the stage of system design and preliminary investigation of a small-sized grid connected wind turbine.

60Hz용 변압기를 이용한 인버터 AC 스폿용접시스템의 용접시간 최소화 (Minimization of Welding Time for an AC Resistance Spot Welding System With 60Hz Transformer)

  • 석진규;강성관;송웅협;노의철;김인동;김흥근;전태원
    • 전력전자학회논문지
    • /
    • 제15권3호
    • /
    • pp.218-225
    • /
    • 2010
  • 본 논문은 인버터 AC 스폿용접시스템의 용접시간을 최소화하기 위한 방법에 관한 것이다. 기존의 SCR 회로방식을 이용한 스폿용접시스템의 경우 제어속도가 느리고 전류제어가 정밀하지 않다. 따라서 최근에는 인버터를 이용한 용접시스템이 점차 증가하고 있다. 2차전지의 전극과 같은 박판을 용접해야 하는 경우에는 용접시간이 수 [ms] 정도로 짧아야 한다. 수 [ms] 정도로 용접시간을 최소화하면서 수 천 [A]에 달하는 대전류를 흘리기 위해서 일반적으로 수십개의 스위칭 소자들을 병렬로 연결하여 사용하기도 한다. 본 논문에서는 단지 4개의 IGBT로 구성된 인버터와 60[Hz] 변압기만으로 수 [ms] 대의 용접이 가능한 비용절감형 용접시스템을 제안하고 특성을 분석하였다. 그리고 실험을 통하여 타당성과 효용성을 입증하였다.