• Title/Summary/Keyword: Micro sensor array

Search Result 70, Processing Time 0.038 seconds

Nano and micro structures for label-free detection of biomolecules

  • Eom, Kil-Ho;Kwon, Tae-Yun;Sohn, Young-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.403-420
    • /
    • 2010
  • Nano and micro structure-based biosensors are promising tool for label-free detection of biomolecular interactions with great accuracy. This review gives a brief survey on nano and micro platforms to sense a variety of analytes such as DNA, proteins and viruses. Among incredible nano and micro structure for bio-analytical applications, the scope of this paper will be limited to micro and nano resonators and nanowire field-effect transistors. Nanomechanical motion of the resonators transducers biological information to readable signals. They are commonly combined with an optical, capacitive or piezo-resistive detection systems. Binding of target molecule to the modified surface of nanowire modulates the current of the nanowire through electrical field-effect. Both detection methods have advantages of label-free, real-time and high sensitive detection. These structures can be extended to fabricate array-type sensors for multiplexed detection and high-throughput analysis. The biosensors based on these structures will be applied to lab-on-a-chip platforms and point-of-care diagnostics. Basic concepts including detection mechanisms and trends in their fields will be covered in this review.

Sensor-less Approaches for Maximum Photovoltaic Power Tracking Control

  • Matsui Mikihiko;Kitano Tatsuya
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.626-630
    • /
    • 2001
  • MPPT (maximum power point tracking) control is very important for the practical PV (photovoltaic) systems to maintain efficient power generating conditions irrespective of the deviation in the PV array insolation or/and temperature conditions. Although a plenty of researches have been done so far, most of them are too costly because of being too dependant on expensive sensors for measuring photovoltaic power and micro-processors for achieving elaborate and complicated control strategies. From this point of view, authors have been researching on sensor-less approaches for MPPT control, and have proposed two types of new control schemes 'Power Equilibrium Scheme' and 'Limit Cycle Scheme'. This paper summarises these two schemes with focussing on their :- operating principles and some results of simulation and experiments.

  • PDF

Quantitative analysis of gas mixtures using a tin oxide gas sensor and fast pattern recognition methods (반도체식 가스센서와 패턴인식방법을 이용한 혼합가스의 정량적 분석)

  • Lee, Jeong-Hun;Cho, Jung-Hwan;Jeon, Gi-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2005.10b
    • /
    • pp.138-140
    • /
    • 2005
  • A fuzzy ARTMAP neural network and a fuzzy ART neural network are proposed to identify $H_2S$, $NH_3$ and their mixtures and to estimate their concentrations, respectively. Features are extracted from a micro gas sensor array operated in a thermal modulation plan. After dimensions of the features are reduced by a preprocessing scheme, the features are fed into the proposed fuzzy neural networks. By computer simulations, the proposed methods are shown to be fast in learning and accurate in concentration estimating. The results are compared with other methods and discussed.

  • PDF

Fabrication of Metallic Nano-filter Using UV-Imprinting Process (UV 임프린팅 공정을 이용한 금속막 필터제작)

  • Noh Cheol Yong;Lee Namseok;Lim Jiseok;Kim Seok-min;Kang Shinill
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.237-240
    • /
    • 2005
  • The demand of micro electrical mechanical system (MEMS) bio/chemical sensor is rapidly increasing. To prevent the contamination of sensing area, a filtration system is required in on-chip total analyzing MEMS bio/chemical sensor. A nano-filter was mainly applied in some application detecting submicron feature size bio/chemical products such as bacteria, fungi and so on. We suggested a simple nano-filter fabrication process based on replication process. The mother pattern was fabricated by holographic lithography and reactive ion etching process, and the replication process was carried out using polymer mold and UV-imprinting process. Finally the nano-filter is obtained after removing the replicated part of metal deposited replica. In this study, as a practical example of the suggested process, a nano-dot array was replicated to fabricate nano-filter fur bacteria sensor application.

  • PDF

Fabrication of Auto-replacable Micro Dissolved Oxygen Sensor Array (자동 교체형 초소형 용존 산소량 측정 센서 어레이의 제작)

  • Lee, Hyun-jin;Park, Jae-Hyoung;Lee, Seung-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1217-1218
    • /
    • 2015
  • 용존 산소 센서는 하천과 연안으로 유입되는 오염원을 측정하는 곳에 사용되고 있다. 상용화되고 있는 용존 산소 센서는 멤브레인의 부유물 점착 및 전해질 변질로 인해 수명이 단축되는 문제점이 있다. 본 연구팀에서는 수명 문제를 해결하기 위해 실시간 연속 측정이 가능한 자동 교체형 초소형 용존 산소 센서를 개발하고자 한다.

  • PDF

A portable electronic nose (E-Nose) system using PDA device (개인 휴대 단말기 (PDA)를 기반으로 한 휴대용 E-Nose의 개발)

  • Yang, Yoon-Seok;Kim, Yong-Shin;Ha, Seung-Chul;Kim, Yong-Jun;Cho, Seong-Mok;Pyo, Hyeon-Bong;Choi, Chang-Auck
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.69-77
    • /
    • 2005
  • The electronic nose (e-nose) has been used in food industry and quality controls in plastic packaging. Recently it finds its applications in medical diagnosis, specifically on detection of diabetes, pulmonary or gastrointestinal problem, or infections by examining odors in the breath or tissues with its odor characterizing ability. Moreover, the use of portable e-nose enables the on-site measurements and analysis of vapors without extra gas-sampling units. This is expected to widen the application of the e-nose in various fields including point-of-care-test or e-health. In this study, a PDA-based portable e-nose was developed using micro-machined gas sensor array and miniaturized electronic interfaces. The rich capacities of the PDA in its computing power and various interfaces are expected to provide the rapid and application specific development of the diagnostic devices, and easy connection to other facilities through information technology (IT) infra. For performance verification of the developed portable e-nose system, Six different vapors were measured using the system. Seven different carbon-black polymer composites were used for the sensor array. The results showed the reproducibility of the measured data and the distinguishable patterns between the vapor species. Additionally, the application of two typical pattern recognition algorithms verified the possibility of the automatic vapor recognition from the portable measurements. These validated the portable e-nose based on PDA developed in this study.

Voltammetric Studies of Anion Transfer Reactions Across a Microhole Array-Water/PVC-NPOE Gel Interface

  • Hossain, Md. Mokarrom;Girault, Hubert H.;Lee, Hye-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.5
    • /
    • pp.1734-1740
    • /
    • 2012
  • Voltammetric characterization of hydrophilic anion transfer processes across a 66 microhole array interface between the water and polyvinylchloride-2-nitrophenyloctylether gel layer is demonstrated. Since the transfer of hydrophilic anions including $Br^-$, $NO_3{^-}$, $I^-$, $SCN^-$ and $ClO_4{^-}$ across the liquid/gel interface usually sets the potential window within a negative potential region, a highly hydrophobic organic electrolyte, tetraoctylammonium tetrakis(pentafluorophenyl)borate, providing a wider potential window was incorporated into the gel phase. The transfer reaction of perchlorate anions across the microhole-water/gel interface was first studied using cyclic voltammetry and differential pulse voltammetry. The full voltammetric response of perchlorate anion transfer was then used as a reference for evaluating the half-wave transfer potentials, the formal transfer potentials and the formal Gibbs transfer energies of more hydrophilic anions such as $Br^-$, $NO_3{^-}$, $I^-$, and $SCN^-$. The current response associated with the perchlorate anion transfer across the micro-water/gel interface versus the perchlorate concentration was also demonstrated for sensing applications.

Three-dimensional Machine Vision System based on moire Interferometry for the Ball Shape Inspection of Micro BGA Packages (마이크로 BGA 패키지의 볼 형상 시각검사를 위한 모아레 간섭계 기반 3차원 머신 비젼 시스템)

  • Kim, Min-Young
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.1
    • /
    • pp.81-87
    • /
    • 2012
  • This paper focuses on three-dimensional measurement system of micro balls on micro Ball-Grid-Array(BGA) packages in-line. Most of visual inspection system still suffers from sophisticate reflection characteristics of micro balls. For accurate shape measurement of them, a specially designed visual sensor system is proposed under the sensing principle of phase shifting moire interferometry. The system consists of a pattern projection system with four projection subsystems and an imaging system. In the projection system, four subsystems have spatially different projection directions to make target objects experience the pattern illuminations with different incident directions. For the phase shifting, each grating pattern of subsystem is regularly moved by PZT actuator. To remove specular noise and shadow area of BGA balls efficiently, a compact multiple-pattern projection and imaging system is implemented and tested. Especially, a sensor fusion algorithm to integrate four information sets, acquired from multiple projections, into one is proposed with the basis of Bayesian sensor fusion theory. To see how the proposed system works, a series of experiments is performed and the results are analyzed in detail.

Laboratory test of MEMS based astronomical adaptive optics

  • Yu, Hyung-Jun;Park, Yong-Sun;Chae, Jong-Chul;Yang, Hee-Su
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.65.1-65.1
    • /
    • 2011
  • We built a simple Adaptive Optics (AO) system at laboratory. This AO system is a step toward developing AO system for astronomical use. In this step, the AO system consists of He-Ne laser as a artificial light source, wavefront sensor, MEMS (Micro electro mechanical system) type deformable mirror and several lenses. MEMS deformable mirror allows the compact system at low cost and the only several mm sized collimated beam. We made Shack-Hartmann wavefront sensor using a lenslet array and a fast frame CCD. Its performance is verified using an artificial phase disturber and noting the movement of spot images by the lenslet array. The frame rate of the driving software is about 70 fps, depending on the control parameters. The characteristics of MEMS deformable mirror was measured which includes the voltage-to-deflection relation, influence function, and cross-talk. The total system is operated under closed-loop control for the artificial phase disturber and the wavefront is found to be compensated successfully.

  • PDF

Design of a Charge-Redistribution ADC Using Bit Extension (비트 확장을 이용한 전하재분배 방식 ADC의 설계)

  • Kim, Kyu-Chull;Doh, Hyung-Wook
    • Journal of IKEEE
    • /
    • v.9 no.1 s.16
    • /
    • pp.65-71
    • /
    • 2005
  • Physical signals generated in the real world are transformed into electrical signals through sensors and fed into electronic circuits. The electrical signals input to electronic circuits are in analog form, thus they must be converted to digital signals using an ADC(Analog-Digital Converter) for digital processing. Signal processing circuits and ADCs that are to be integrated on a single chip together with silicon micro sensors should be designed to have less silicon area and less power consumption. This paper proposed a charge redistribution ADC which reduces silicon area considerably. The proposed method achieves 8 bit conversion by performing 4-bit conversion twice. It reduced the area of capacitor array, which takes most of the ADC area, by 1/16 when compared to a conventional method. Though it uses twice the number of clocks as a conventional method, it would be appropriate to be integrated with a silicon pressure sensor on a single chip since it does not demand high conversion rate.

  • PDF