• 제목/요약/키워드: Micro plasma

검색결과 504건 처리시간 0.031초

O2/ Ar 플라즈마 처리에 의해 개질된 폴리카보네이트 기판에서 Cu의 밀착성 (Adhesion of Cu on Polycarbonate Modified by O2/ Ar Plasma Treatment)

  • 박준규;김동원;김상호;이연승
    • 한국재료학회지
    • /
    • 제12권9호
    • /
    • pp.740-746
    • /
    • 2002
  • In this study, the polycarbonate surface was treated by $O_2$/ Ar gases plasma for the enhancement of adhesion with Cu electrode. From the point of view of hydrophilicity and the functionality, the micro-roughness, new functional groups and oxygen content of the polycarbonate surface were increased by the $O_2$/ Ar gases plasma treatment. The Cu films deposited on the as-received polycarbonate were easily detached while, after the$ O_2$/ Ar gases plasma treatment the adhesive Cu films on polycarbonate could be obtained. These results can be explained that the polycarbonate had a hydrophilic surface with uniform micro-roughness and new functional groups by $O_2$/ Ar gases plasma treatment. Therefore,$O_2$/ Ar gases plasma treatment is a promising method for improvement of adhesion between polycarbonate and Cu electrode.

진공 플라즈마 용사공정에 의한 MCrAlY코팅재의 음향방출 신호 특성 연구 (A Study on Acoustic Emission Characteristics of MCrAlY Coated Material by Vacuum Plasma Spray Process)

  • 박진효;이구현;예경환;김정석;강명창
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.921-924
    • /
    • 2004
  • This paper is to investigate a crack for plasma sprayed MCrAlY coated material by acoustic emission method in 4-point bending test. The CoNiCrAlY is coated on Inconel-718 by vacuum plasma spray process. Micro-hardness measurement was conducted by means of Micro Vickers-hardness indentor. The porosity of coating layer was measured using a SEM and Image Analyzer. AE monitoring system is composed of PICO type sensor, a wide band preamplifier(40dB), a PC and AE DSP(16/32 PAC) board. The AE count, Hit and energy of coating specimens is measured according to coating thickness.

  • PDF

상압 마이크로 글로우 방전 분사 소자 (Atmospheric Micro Glow Plasma-jet Device)

  • 김강일;홍용철;김근영;양상식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1533_1534
    • /
    • 2009
  • This paper presents an atmospheric micro glow plasma-jet device. The device consists of four components; a thin Ni anode, a porous alumina insulater, a stainless steel cathode and an aluminum case. The Ni anode is fabricated using micromachining technology. The anode has 10 holes, of which the hole diameter and the depth are $250{\mu}m$ and $60{\mu}m$, respectively. The discharge test is performed in nitrogen gas at atmospheric pressure for 20 kHz AC bias. The breakdown voltage is 3.5 kV at gas flow rate of 4 L/min and the the plasma-jet is blown out to ambient at 5.5 kV. In order to verify the characteristics of plasma, the current and the voltage of device are measured. The maximum temperature of plasma is $37^{\circ}C$. The plasma is well generated and stable at high voltage.

  • PDF

Plasma Post-operative miR-21 Expression in the Prognosis of Gastric Cancers

  • Ma, Guo-Jian;Gu, Rong-Min;Zhu, Ming;Wen, Xu;Li, Jin-Tian;Zhang, Yuan-Ying;Zhang, Xiao-Mei;Chen, Sen-Qing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제14권12호
    • /
    • pp.7551-7554
    • /
    • 2013
  • Tumor-associated microRNAs have been detected in serum or plasma, but whether plasma microRNA-21 (miR-21) could be a potential circulating biomarker for gastric cancer (GC) prognosis in Chinese is still uncertain. Real-time quantitative reverse transcription PCR (qRT-PCR) was employed in this study to compare the relative expression of miR-21 between pre-operative and post-operative paired plasmas from 42 patients with primary GCs. The results showed that the expression levels of miR-21 in the post-operative plasmas were significantly reduced by an average of 18.2 times in all patients when compared to the pre-operative plasmas, and by 22.1 times in the subgroup of patients without family history, while only 1.76 times in the subgroup of patients with a family history. With respect of clinicopathological characteristics, the plasma miR-21 expression was highly associated with differentiation degree and lymph node metastasis rate. The results suggested plasma miR-21 could be a novel potential biomarker for GC prognosis and evaluation of surgery outcomes, especially in patients without a family history.

직류 마이크로 할로우 음극 방전을 이용한 이단 마이크로 플라즈마 추력기의 배기 플룸의 형상 특성 (Shape Characteristics of Exhaust Plume of Dual-Stage Plasma Thruster using Direct-Current Micro-Hollow Cathode Discharge)

  • ;신지철
    • 한국추진공학회지
    • /
    • 제20권3호
    • /
    • pp.54-62
    • /
    • 2016
  • 이단 마이크로 할로우 음극 방전(MHCD) 플라즈마를 사용하는 마이크로 플라즈마 추력기(${\mu}PT$)에 대한 실험 연구가 수행되었다. 40 sccm의 아르곤 유량과 10 W 미만의 전력으로 보다 더 직진성 있고 긴 침투 길이를 가진 배기 플룸을 만드는 정전기적 가속이 이단 MHCD에 의해 발생되었다. 전압-전류 특성에서는 이단 운전 시 두 번째 단의 가속 전압이 일정하게 되는 최적 영역이 있음을 보였다. 추정된 배기 플룸의 길이가 가속 전압으로 추산된 이론적 배출 속도와 비슷한 증가 경향을 보였다. 다중 채널을 가진 마이크로 플라즈마 추력기는 동일한 총 전력량에 대하여 단일 채널 추력기와 비슷한 특성을 보여, 이는 채널 당 허용 전력량을 낮춰 전체 전력량을 높일 수 있음을 의미한다. 아르곤 원자 분광선의 볼츠만 그래프에서 배기 플룸의 평균 전자 여기 온도는 약 2.6 eV(=약 30,170 K)임이 확인되었다.

실험 계획법을 이용한 점착방지막용 플라즈마 증착 공정변수의 최적화 연구 (Optimizing the Plasma Deposition Process Parameters of Antistiction Layers Using a DOE (Design of Experiment))

  • 차남구;박창화;조민수;박진구;정준호;이응숙
    • 한국재료학회지
    • /
    • 제15권11호
    • /
    • pp.705-710
    • /
    • 2005
  • NIL (nanoimprint lithography) technique has demonstrated a high potential for wafer size definition of nanometer as well as micrometer size patterns. During the replication process by NIL, the stiction between the stamp and the polymer is one of major problems. This stiction problem is moi·e important in small sized patterns. An antistiction layer prevents this stiction ana insures a clean demolding process. In this paper, we were using a TCP (transfer coupled plasma) equipment and $C_4F_8$ as a precursor to make a Teflon-like antistiction layer. This antistiction layer was deposited on a 6 inch silicon wafer to have nanometer scale thicknesses. The thickness of deposited antistiction layer was measured by ellipsometry. To optimize the process factor such as table height (TH), substrate temperature (ST), working pressure (WP) and plasma power (PP), we were using a design of experimental (DOE) method. The table of full factorial arrays was set by the 4 factors and 2 levels. Using this table, experiments were organized to achieve 2 responses such as deposition rate and non-uniformity. It was investigated that the main effects and interaction effects between parameters. Deposition rate was in proportion to table height, working pressure and plasma power. Non-uniformity was in proportion to substrate temperature and working pressure. Using a response optimization, we were able to get the optimized deposition condition at desired deposition rate and an experimental deposition rate showed similar results.

생체 삽입형 유연한 마이크로 전극의 제작 및 평가 (Fabrication and Evaluation of the Flexible and Implantable Micro Electrode)

  • 백주열;권구한;이상운;이기암;이상훈
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권2호
    • /
    • pp.93-99
    • /
    • 2006
  • In this paper, we fabricated and evaluated polydimethylsiloxane(PDMS)-based flexible and implantable micro electrodes. The electrode patterning was carried out with the photolithography and chemical etching process after e-beam evaporation of 100 ATi and 1000 A Au. The PDMS substrate was treated by oxygen plasma using reactive ion etching(RIE) system to improve the adhesiveness of PDMS and metal layers. The minimum line width of fabricated micro electrode was 20 $\mu$m. After finished patterning, we did packaging with PDMS and then brought up the electrode's part about 40 $\mu$m with gold electroplating. The Hank's balanced salt solution(HBSS) test was carried out for 6 month for endurance of fabricated micro electrode. We carried out in-vivo test for the evaluation of biocompatibility by implanting electrodes under the ICR mouse skin for 42 days.

마이크로 엔드밀에 의한 미세격벽가공의 가공특성에 관한 연구 (A Study on the Machining Characteristics fur Micro Barrier Ribs by using Micro Endmilling)

  • 민승기;이선우;이동주;이응숙;제태진
    • 한국공작기계학회논문집
    • /
    • 제11권3호
    • /
    • pp.14-20
    • /
    • 2002
  • Recently, miniaturization and mass production are the main trends in manufacturing fields. Therefore, ultraprecision machining and MEMS technology have been taken more 7md more important position in machining of microparts. Micro endmilling is one of the prominent technology that has wide spectrum of application field ranging from duo parts to micro products, such as PDP md IT components, in precision products manufacturing. However, decreasing of burr is significant problem in making smooth and precise parts in micro endmilling. This paper shows removal characteristics of burr generated by micro endmilling process. This results satisfies micro endmilling for micro barrier ribs of heights is $50{\mu}m$, $100{\mu}m$, $200{\mu}m$, $300{\mu}m$, and observation from of burr. Additionally, it is necessary to understand the formation mechanism of burr of micro barrier ribs to iud proper decreasing method.

Plasma Surface Modification of Patterned Polyurethane Acrylate (PUA) Film for Biomedical Applications

  • Yun, Young-Shik;Kang, Eun-Hye;Yun, In-Sik;Kim, Yong-Oock;Yeo, Jong-Souk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.223.2-223.2
    • /
    • 2015
  • Polyurethane acrylate (PUA) has been introduced to utilize as a mold material for sub-100 nm lithography as it provides advantages of stiffness for nanostructure formation, short curing time, flexibility for large area replication and transparency for relevant biomedical applications. Due to the ability to fabricate nanostructures on PUA, there have been many efforts to mimic extracellular matrix (ECM) using PUA especially in a field of tissue engineering. It has been demonstrated that PUA is useful for investigating the nanoscale-topographical effects on cell behavior in vitro such as cell attachment, spreading on a substrate, proliferation, and stem cell fate with various types of nanostructures. In this study, we have conducted surface modification of PUA films with micro/nanostructures on their surfaces using plasma treatment. In general, it is widely known that the plasma treated surface increases cell attachment as well as adsorption of ECM materials such as fibronectin, collagen and gelatin. Effect of plasma treatment on PUA especially with surface of micro/nanostructures needs to be understood further for its biomedical applications. We have evaluated the modified PUA film as a culture platform using adipose derived stem cells. Then, the behavior of stem cells and the level of adsorbed protein have been analyzed.

  • PDF

플라즈마 제트에서의 분말 용융특성에 따른 Y2O3 코팅층의 미세조직 형성거동 (Effects of Powder Melting Degree on Microstructural Features of Plasma Sprayed Y2O3 Coating)

  • 강상운;백경호
    • 한국재료학회지
    • /
    • 제26권5호
    • /
    • pp.229-234
    • /
    • 2016
  • In this study, the degree of particle melting in $Y_2O_3$ plasma spraying and its effects on coating characteristics have been investigated in terms of microstructural features, microhardness and scratch resistance. Plasma sprayed $Y_2O_3$ coatings were formed using two different powder feeding systems: a system in which the powder is fed inside the plasma gun and a system in which the powder is fed externally. The internal powder spraying method generated a well-defined lamellae structure that was characterized by a thin porous layer at the splat boundary and microcracks within individual splats. Such micro-defects were generated by the large thermal contraction of splats from fully-molten droplets. The external powder spraying method formed a relatively dense coating with a particulate deposition mode, and the deposition of a higher fraction of partially-melted droplets led to a much reduced number of inter-splat pores and intra-splat microcracks. The microhardness and scratch resistance of the $Y_2O_3$ coatings were improved by external powder spraying; this result was mainly attributed to the reduced number of micro-defects.