• Title/Summary/Keyword: Micro optical system

Search Result 357, Processing Time 0.032 seconds

Tolerance design of position accuracy of optical components for micro optical system (마이크로 광 시스템 구현을 위한 광학 부품의 위치 정밀도 허용오차 설계)

  • 이재영;황병철;박헌용;박세근;이승걸;오범환;이일항;최두선
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.7
    • /
    • pp.13-20
    • /
    • 2004
  • In order to set up the design of micro optical bench, optical coupling efficiencies of two sets of test benches are calculated. Simple linear connections of incoming and outgoing optical fibers with and without ball lenses are designed. Positional errors that are possible in actual fabrication processes we considered in the calculations and their tolerances are determined from -3 ㏈ conditions. For a simple fiber-to-fiber connection, the lateral misalignment should be limited to 2.7 um and tilt error 5.8o. In case of the fiber-to-fiber with ball lens, the working distance between fibers can be extended over 60 um. The optical coupling efficiency depends strongly on the positional errors of ball lenses along the optical axis, and it is also found that the lateral and vertical positional errors should be considered simultaneously in order to keep the high coupling efficiency.

The Scattering Beam Measurement of the RBC and the Fabrication of the Micro Cell Biochip (적혈구의 산란빔 측정과 마이크로 세포 분석 바이오칩 제작)

  • Byun, In Soo;Kwon, Ki Jin;Lee, Joon Ha
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.116-121
    • /
    • 2014
  • Next future, The bio technology will be a rapidly developing. This paper is the scattering beam measurement of the red blood cell (RBC) and the fabrication of the micro cell biochip using the bio micro electro mechanical system (Bio-MEMS) process technology. The Major process method of Bio-MEMS technology was used the buffered oxide etchant (BOE), electro chemical discharge (ECD) and ultraviolet sensitive adhesives (UVSA). All experiments were the 10 times according to the process conditions. The experiment and research are required the ultraviolet expose, the micro fluid current, the cell control and the measurement of the output voltage Vpp (peak to peak) waveform by scattering angles. The transmitting and receiving of the laser beam was used the single mode optical fiber. The principles of the optical properties are as follows. The red blood cells were injected into the micro channel. The single mode optical fiber was inserting in the guide channel. The He-Ne laser beam was focusing in the single mode optical fiber. The transmission He-Ne laser beam is irradiating to the red blood cells. The manufactured guide channel consists of the four inputs and the four outputs. The red blood cell was allowed with the cylinder pump. The output voltage Vpp waveform of the scattering beam was measured with a photo detector. The receiving angle of the output optical fiber is $0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $15^{\circ}$. The magnitude of the output voltage Vpp waveform was measured in the decrease according to increase of the reception angles. The difference of the output voltage Vpp waveform is due differences of the light transmittance of the red blood cells.

Absolute Positioning System of Mobile Robot using Light Navigation Path (광궤도를 이용한 이동로봇의 절대위치 보정 시스템)

  • 박용택;정효용;국금환
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.10
    • /
    • pp.141-147
    • /
    • 2003
  • This paper represents an absolute positioning system using a light navigation path for mobile robot. The absolute positioning system is composed of the projector unit which generates a laser beam using laser diode and mobile robot with the optical detector which has some optical sensors. The projector unit is fixed over the navigating plane of mobile robot to generate the light navigation path, and the optical detector located upper part of mobile robot detects the generated laser beam from the projector. The navigation of mobile robot is controlled by the micro-processor which compares the detected present position from the detector with the previously programmed navigation path. And experimental results show that our sensor system can be used for the absolute positioning system of the mobile robot.

Application of a New NDI Method using Magneto-Optical Film for Inspection of Micro-Cracks (미소균열 탐상을 위한 자기광학소자를 이용한 비파괴탐상법의 제안과 적용)

  • Lee, Hyoung-No;Park, Han-Ju;Shoji, Tetsuo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.2
    • /
    • pp.197-203
    • /
    • 2001
  • Micro-defects induced by design and production failure or working environments are known as the cause of SCC(Stress Corrosion Cracking) in aged structures. Therefore, the evaluation of structural integrity based on micro-cracks is required not only a manufacturing step but also in-service term. So we introduce a new nondestructive inspection method using the magneto-optical film to detect micro-cracks. The method has some advantage such as high testing speed, real time data acquistion and the possibility of remote sensing by using of a magneto-optical film that takes advantage of the change of magnetic domains and domain walls. This paper introduces the concept of the new nondestructive inspection method using the magneto-optical film, also proves the possibility of this method as a remote testing system under oscillating load considering application on real fields by applying the method to four types of specimens.

  • PDF

Trends of Flat Mold Machining Technology with Micro Pattern (미세패턴 평판 금형가공 기술동향)

  • Je, Tae-Jin;Choi, Doo-Sun;Jeon, Eun-Chae;Park, Eun-Suk;Choi, Hwan-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.2
    • /
    • pp.1-6
    • /
    • 2012
  • Recent ultra-precision machining systems have nano-scale resolution, and can machine various shapes of complex structures using five-axis driven modules. These systems are also multi-functional, which can perform various processes such as planing, milling, turning et al. in one system. Micro machining technology using these systems is being developed for machining fine patterns, hybrid patterns and high aspect-ratio patterns on large-area molds with high productivity. These technology is and will be applied continuously to the fields of optics, display, energy, bio, communications and et al. Domestic and foreign trends of micro machining technologies for flat molds were investigated in this study. Especially, we focused on the types and the characteristics of ultra-precision machining systems and application fields of micro patterns machined by the machining system.

A Ghost-Imaging System Based on a Microfluidic Chip

  • Wang, Kaimin;Han, Xiaoxuan;Ye, Hualong;Wang, Zhaorui;Zhang, Leihong;Hu, Jiafeng;Xu, Meiyong;Xin, Xiangjun;Zhang, Dawei
    • Current Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.147-154
    • /
    • 2021
  • Microfluidic chip technology is a research focus in biology, chemistry, and medicine, for example. However, microfluidic chips are rarely applied in imaging, especially in ghost imaging. Thus in this work we propose a ghost-imaging system, in which we deploy a novel microfluidic chip modulator (MCM) constructed of double-layer zigzag micro pipelines. While in traditional situations a spatial light modulator (SLM) and supporting computers are required, we can get rid of active modulation devices and computers with this proposed scheme. The corresponding simulation analysis verifies good feasibility of the scheme, which can ensure the quality of data transmission and achieve convenient, fast ghost imaging passively.

An optical true time delay for 10 GHz linear phased array antennas composed of optical 2×2 MEMS switches and fiber delay lines (광 2×2 MEMS 스위치와 광섬유 지연선로를 이용한 10 GHz 선형 위상배열 안테나용 광 실시간 지연선로)

  • 이백송;신종덕;김부균
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.4
    • /
    • pp.466-472
    • /
    • 2003
  • In this paper, we proposed an optical true time-delay (TTD) feeder system for phased array antennas (PAAs). The system possesses high-speed beam scan capability since, in this scheme, different lengths of fiber delay-lines are selected by optical 2${\times}$2 MEMS switches at high speed. An optical TTD capable of beam scanning in one of eight different directions has been built for 10 GHz linear PAA systems. Experimental results on time delay measurements show that the maximum time delay error is less than 0.2 ps corresponding to a scan angle error of less than 0.84o. We have also designed a 10 GHz linear PAA composed of eight micro-strip patch antenna elements driven by the proposed TTD, and the radiation patterns of this PAA have been analyzed by simulation.

Design and Fabrication of Micro SLM for Phase and Amplitude Modulation (위상 및 방향 변조를 위한 초소형 광 변조기의 설계와 제작)

  • Chung, Seok-Whan;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3298-3300
    • /
    • 1999
  • In this paper, a $10{\times}10$ micro SLM array for phase and amplitude modulation of incident light is designed and fabricated using surface micromachining technology. Hidden spring structure is used in order to maximize the fill-factor and minimize diffraction effect at the support posts. Static and dynamic characteristics of designed micro SLM are simulated with ABAQUS and measured with optical measurement system using He-Ne laser and PSD(position sensitive devise).

  • PDF

Detection of Tendon Tears by Degree of Linear Polarization Imaging

  • Kim, Ji-Hoon;Oh, Jung-Hwan;Kang, Hyun-Wook;Lee, Ho;Kim, Jee-Hyun
    • Journal of the Optical Society of Korea
    • /
    • v.13 no.4
    • /
    • pp.472-477
    • /
    • 2009
  • A Stokes polarimetry imaging (SPI) system was developed and utilized to detect tendon tears by constructing the degree of linear polarization (DOLP) image maps after linearly polarized light illumination. The micro and partial-thickness tears of turkey tendons were made and imaged by the SPI system at different incident polarization angles (IPA) with different mechanical loads on the tendon. The micro and partial-thickness tendon tears were detected by the DOLP images due to weak birefringence around the tears. The tendon tears were detected by a highest DOLP contrast at longest visible wavelength (Red, 650 ${\pm}$ 50 nm). All polarized images showed modulated DOLP as the incident polarization angle (IPA) was varied. The varying DOLP allowed the optimal detection of the micro and partial-thickness tendon tears at a certain IPA. The SPI system with variable IPA and spectral information can improve the detection of the tendon tears by higher visibility of fiber orientations, and thereby improve diagnosis and treatment of the tendon related injuries.

Fabrication of 3D structures using micro-stereolithography technology (극소 광 조형기술을 이용한 3차원 구조물의 제작)

  • 이인환;조동우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.1080-1083
    • /
    • 1997
  • Micro-stereolithography is a newly proposed technology as a means that can fabricate 3D micro-structures of free form. It makes a 3D structure by dividing the shape into many slices of relevant thickness along honzontal surfaces, hardening each layer of slice with a laser, and stacking them up to a des~red shape. Scale effect becomes important in this micro-fabrication process, d~fferently from the conventional stereolithography. To realize this micro-stereolithography technology, we developed an equipment using Ar+ laser, xyz stages, controllers and all the optic devices. Using the equipment, a number of micro-structures were successfully fabricated including a winecup of several tens of micrometers.

  • PDF