• Title/Summary/Keyword: Micro mechanical device

Search Result 267, Processing Time 0.028 seconds

Correction Method for Orientation of Cylindrical Moving Part in Micro-Positioning Device (정밀 위치 결정 기구에서 원통형 구동부의 자세 보정)

  • Jo, Nam-Gyu;Kim, Do-Hyeon;Gwon, Gi-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.11
    • /
    • pp.42-50
    • /
    • 2001
  • In this paper, a new technique and theory are proposed which correct the orientation (inclination of a vertical axis) of a cylinder in vertical-micro positioning device. An algorithm for determining the orientation of the cylinder with a pair of displacement sensor units is derived and two types of the correction methods are described. To assess the performance and efficiency of the developed correction technique, the compensation errors originated from the correction algorithm and the machined characteristics of cylinder surface are evaluated from the geometrical considerations and the statistical techniques. Based upon the evaluation results, the maximum compensation error is estimated for the orientation of cylinder and the optimum correction technique is derived.

  • PDF

Flow Visualization in a new CSC micromixer (새로운 CSC micromixer 를 이용한 유동가시화)

  • Singh, Kanika;Kim, Hyun-Hoon;Min, Young-Uk;Kim, Hyung-Dong;Kim, Kyung-Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.63-65
    • /
    • 2007
  • The paper reports on a new type of combinatorial chaotic and serpentine micromixer. Such a new and novel micromixer is simple to fabricate and easy to use. The micromixer is characterized and visualized with the help of the Micro-LIF technique. The new micromixer will e further applied to lab-on-chip device. The mixing capabilities of this mixer is about 30-33%.

  • PDF

Development of 3D Micro-Nano Hybrid Patterns Using Anodized Aluminum and Micro-Indentation (양극산화된 알루미늄과 마이크로 인덴데이션을 이용한 3차원 마이크로-나노 하이브리드 패턴 제작)

  • Kwon, Jong-Tae;Shin, Hong-Gue;Kim, Byeong-Hee;Seo, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.12
    • /
    • pp.1139-1143
    • /
    • 2007
  • A simple method for the fabrication of 3D micro-nano hybrid patterns was presented. In conventional fabrication methods of the micro-nano hybrid patterns, micro-patterns were firstly fabricated and then nano-patterns were formatted on the micro-patterns. Moreover, these micro-nano hybrid patterns could be fabricated on the flat substrate. In this paper, we suggested the fabrication method of 3D micro-nano hybrid patterns using micro-indentation on the anodized aluminum substrate. Since diameter of the hemispherical nano-pattern can be controlled by electrolyte and applied voltage in the anodizing process, we can easily fabricated nano-patterns of diameter of loom to 300nm. Nano-patterns were firstly formatted on the aluminum substrate, and then micro-patterns were fabricated by deforming the nano-patterned aluminum substrate. Hemispherical nano-patterns of diameter of 150nm were fabricated by anodizing process, and then micro-pyramid patterns of the side-length of $50{\mu}m$ were formatted on the nano-patterns using micro-indentation. Finally we successfully replicated 3D micro-nano hybrid patterns by hot-embossing process. 3D micro-nano hybrid patterns can be applied to nano-photonic device and nano-biochip application.

Mechanism Design of the Micro Weighing Device by Using Null Balance Method (영위법을 이용한 미소중량 측정 장치의 기구설계)

  • Choi, In-Mook;Woo, Sam-Yong;Kim, Boo-Shik;Kim, Soo-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.1
    • /
    • pp.183-193
    • /
    • 2003
  • Micro-weighing device by using null balance method is being essential part in fields of high-technology industries such as precision semiconductor industry, precision chemistry, biotechnology and genetics etc. Also, requirements for high resolution and for large measurement range increase more and more. The performance of the micro-weighing device can be determined by the mechanism design and analysis. The analytical design method has been proposed for the performance improvement such as resolution, measurement range and fast response. The 2-stage displacement amplification is designed to overcome the limit of conventional force transmitting lever. The parallel spring is designed for the measurement result independent of the input force position variation. Also, the natural frequency of mechanism is analyzed for the fast response. After each analysis, optimal design has been carried out. To verify the analysis and design result, characteristics experiments had been carried out after construction. Finally, the system had been controlled.

Development of Wear Analysis Model of Precision Small Rotating Device (정밀소형회전기구의 마모해석모델에 관한 연구)

  • 여은구;조선형;이용신
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.355-358
    • /
    • 2003
  • Recently, micro forming process technology have been developed since the size of machine parts become the crucial factor for minimizing of products in general electronic products. Most small machine parts consist of gear and rotation axis and the wear by mechanical contact is known as the primary factor for life reduction of high precision machine part. Lots of studies for mechanical wear and friction have been reported and many researches of MEMS technology have been studied recently. But just few studies for wear of micro or milli sized machine part have teen implemented. In this research, the wear equation is suggested according to the contact shape of axial part in micro or milli sized machine part. And wear analysis model which can predict the magnitude of wear through this suggested equation with numerical analysis program.

  • PDF

Evaluation of micro jet nozzle using finite elements method (유한요소해석을 이용한 마이크로 분사 노즐 특성 평가)

  • Lim, Dong-Wook;Choi, Doo-Sun;Kim, Tae-min;Park, Jung-Rae;Park, Kyu-Bag;Ham, Hwi-Chan;Kim, Ji-Hun
    • Design & Manufacturing
    • /
    • v.14 no.3
    • /
    • pp.57-62
    • /
    • 2020
  • In the drug delivery system industry, the technology with even split injection becomes important for maximizing efficiency and minimizing the side effects. In conventional drug delivery system, infection can occur due to pain and splashing. Also, various applications are impossible due to disposable use, and it is the reason to avoid to use this system because of the complexity of the driving method. Therefore, in this study, a painless drug delivery device is developed for non-pain with electrical insulation breakdown method. Finite elements analysis was used to evaluate the ejection characteristics of drugs according to the shape of the micro ejection nozzle. The effect of the number of holes in the micro nozzle, the length of the nozzle and the inner shape of the nozzle on the drug discharge characteristics were analyzed.

A Study on Laser Interferometer Development for Micro Displacement Measurement in Micro Former (마이크로 성형기에서 미세 변위 측정을 위한 레이저 간섭계 개발에 관한 연구)

  • 최재원;김대현;최경현;이석희;김승수;나경환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1195-1198
    • /
    • 2003
  • Micro former has been known as a useful tool for machining micro parts. It makes micro holes automatically with punches, a hole-shape die and material by rotation of crank shaft synchronously. Micro displacement in micro forming affects on the performance of machining because micro forming size is similar with its mechanical displacement. Therefore, the measurement of this micro displacement is essential to be guaranteed to obtain high forming precision in the whole machine as well as its devices. This paper addresses the development of a laser interferometer to measure micro displacement for a micro former. The laser interferometer is able to measure micro displacement during a few micro seconds with non-contact. For the experiment, a laser probe is installed on the optical table with optical devices and a micro displacement generating device. The velocity decoding board is also added to calculate doppler shift frequency directly. Finally simple experiments are conducted to confirm its functional operation.

  • PDF

Performance Evaluation of Microchip Removal Device Rotating by Conveyor Belt with Neodymium Permanent Magnet (네오디뮴 영구자석을 이용한 컨베이어벨트 구동형 미세칩 포집장치의 성능 평가)

  • Choi, Sung-Yun;Wang, Jun-hyeong;Wang, Duck Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.1
    • /
    • pp.103-109
    • /
    • 2021
  • Fine chips generated by machining have an impact on machine failure and quality of machined products, it is necessary to remove the chips, so the microchip collection and removal device by rotating conveyor belt with neodymium permanent magnets was developed. In this research, to solve the problem for reducing the existing microchips in the tank, a micro-chip removal device by rotating conveyor belt with neodymium permanent magnets developed. In the development of micro-chip removal device, 3D CATIA modeling was used, and the flow analysis and the electromagnetic force analysis were performed with COMSOL Multiphysics program. To evaluate the performance of the prototypes produced, design of experiments (DOE) is used to obtain the effect of neodymium conveyor movement speed on chip removal for the ANOVA analysis of recovered powders. An experiment was conducted to investigate the effect of the conveyor feed rate on the chip removal performance in detail. As a result of the experiment, it was confirmed that the slower the feeding speed of the fine chip removing device, the more efficient the chip removal.

Theoretical Velocity Analysis of Micro Robot Based on Crawling Locomotive Mechanism for Pipe Inspection Micro Robot (Crawling 방식을 이용한 관 탐사용 소형 로봇의 이동속도 해석)

  • Jang, Ki-Hyun;Park, Hyun-Jun;Kim, Byung-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.8
    • /
    • pp.633-641
    • /
    • 2008
  • Recently, the necessity for diagnosis and management of pipes has emerged as the issue due to contamination of water supply generated by corrosion of pipes. Although inspection has been performed with industrial endoscopes, the method has limits for full diagnosis of pipes due to the lack of working range. As a solution for this problem, many locomotive mechanisms for a micro robot with endoscope functions were proposed. In this paper, we analyze the locomotive mechanism of crawling robot proposed as locomotive device for pipe inspection. Based on a mechanical modeling of motor and micro robot inside small pipe, the theoretical formula for velocity is obtained. This derived theoretical formula is demonstrated the feasibility through the comparison with experimental result. Also, we could find the most important element influencing the moving velocity of micro robot when the robot operates in small pipe. Consequently, it is expected that this study can supply useful information to design of crawling robot to move in small pipe.

PRESSURE MODULAION ON MICRO-MACHINED PORT FUEL INJECTOR PERFORMANCE

  • Kim, H.;Im, K.S.;Lai, M.C.
    • International Journal of Automotive Technology
    • /
    • v.5 no.1
    • /
    • pp.9-16
    • /
    • 2004
  • An experimental study was carried out to characterize the spray atomization process of micro-machined port fuel injectors with a piezoelectric atomization device, which can generate pressure pulsations through vibration of a piezoelectric transducer. In this study, several types of micro-machined arrays such as 30∼200-microns of hole arrays were tested. Both a dual-stream and a central-port injectors with micro-machined arrays were tested and compared with normal port fuel injectors. The spray visualization was conducted to characterize overall spray structure and phase Doppler particle analyzer (PDPA) system was used to quantify the droplet size and velocity. In addition, the pressure history was recorded by using digitized signal from pressure transducer. The results showed that modulation is effective to the spray atomization for tested injectors and atomization performance depends on injector design factors, orifice sizes, and frequency and power of the modulator. A number of resonance frequencies of the modulator was modified by injector parameters and temperature. In addition, our results suggested that design of sufficient space among holes is critical to avoid droplet coalescence in the multi-hole micro-machined injectors.