• 제목/요약/키워드: Micro features

Search Result 384, Processing Time 0.031 seconds

Integrated Management of OSI network and TCP/IP interned with Delegation and Security Features (위임과 보안 성질을 통한 OSI망과 TCP/IP 인터네트의 통합관리)

  • Kim, Tae-Yeon;Seo, Jae-Hyeon;No, Bong-Nam
    • The Transactions of the Korea Information Processing Society
    • /
    • v.2 no.6
    • /
    • pp.891-902
    • /
    • 1995
  • To integrate both the OSI network and the TCP/IP internet, the application gateway that have the powerful and flexible paradigms has been used, but due to the micro-managements of the gateway produce the high costs and the long delay of communication in the case of emergency. The mechanism that maps the access control policies between two domains using the different security policies is needed. These problems are caused by integrating both domains with the different standards. In this paper, the application gateway that delegating to an agent the powerful and flexible services of the CMIP as well as the management functions were proposed. A proposed algorithm that delegates he management script to an gateway safely by capitalizing on the Diffie-Hellman's distribution method, and presents the security mechanism mediating the security policies for guaranteeing the secure communication between two domains using the different security policies.

  • PDF

Diagnostic and Prognostic Value of miR-205 in Colorectal Cancer

  • Orang, Ayla Valinezhad;Safaralizadeh, Reza;Feizi, Mohammad Ali Hosseinpour;Somi, Mohammad Hossein
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.9
    • /
    • pp.4033-4037
    • /
    • 2014
  • Emerging evidence has shown associations of microRNA-205 (miR-205) with crucial cell processes such as the epithelial-mesenchymal transition (EMT) and aberrant expression with tumorigenesis in many types of human malignancy. This prospective study characterized the contribution of miR-205 to the colorectal cancer (CRC) tumorigenesis. The real-time reverse transcription-polymerase chain reaction was used to examine miR-205 levels prospectively in 36 pairs of samples of CRC tissue and adjacent noncancerous tissue (>2 cm from cancer tissue). In addition, the relationship between miR-205 levels and clinicopathological features was explored. The capability of miR-205 to function as a tumor marker was also examined. miR-205 expression levels did not show significant changes overall. However, miR-205 was significantly downregulated in a group of CRC samples compared with matched noncancerous tissue samples. Moreover, decreased miR-205 correlated significantly with lymphatic metastasis. A receiver operating characteristic (ROC) curve also showed an optimum cut off point of $1.4{\times}10^{-3}$ to distinguish lymphatic metastatic CRCs from non-metastatic CRCs. Interestingly we found lymphatic metastasis in almost 80% of the depressed samples. This study suggested that miR-205 could be reduced in the majority of metastatic CRCs and the risk of CRC metastasis may be predicted by monitoring miR-205 in patient samples collected at the time of the initial diagnosis. Therefore, targeting miR-205 and its potential environmental activators might be a promising therapeutic option to prevent malignant progression toward metastasis.

The Deformation Properties and their Formative Processes in Ogcheon Terrain around Ogcheon Town, North Chungcheong Province, Korea (옥천대(沃天帶)의 변형특성(變形特性)과 그 형성(形成) 과정(過程) -충북(忠北) 남서단(南西端)을 예(例)로 하여-)

  • Lee, Byung-Joo;Park, Bong-Soon
    • Economic and Environmental Geology
    • /
    • v.16 no.2
    • /
    • pp.111-123
    • /
    • 1983
  • The studied area is situated in tho southern part of the Ogcheon fold belt, where the "Ogcheon Group" is widespread with Jurassic and Cretaceous intrusions. The regional stratigraphy may be divided into three formations, the lower pebble bearing phyllitic, the middle dark grey phyllitic, and the upper black phyllitic formations. For the purposes of the present study, the area has been partitioned to three structural subareas based on major fold axes and fault line. The main subjects of the research have been discussed from two different points, multiple deformation and minor-micro fold styles. The former is analyzed by pebble elongation, folding and lineation in a pebbly formation as well as schistosity, crenulation cleavage and crenulated lineation in the phyllitic formation. The later describes the characteristic features of fold style in each formation and structural subarea. Although minor fold axes within broad pelitic rocks usually tend to trend northeast and to plunge northward, most of these were probably formed by two stages, first a similar fold phase and second a kink fold phase. Measured structural elements indicate that crenulation cleavage in phyllite formed parallel to fold axes of folded pebble followed a NE phase of first deformation and a fold axes of pebbles diagonal to bedding of phyllite are represented by a NW phase of a second deformation. Microscopically, quartz and mica grains form a micro fold enabling one to establish tectonic levels which occur in different deformation modes in each stratigraphic sequence. Microtextures such as crenulation cleavage, kink band, aggregate band of mica and pressure shadows of porphyroblast of quartz related to qarnet and staurolite may suggest the time relation of crystallization and tectonism. The result of this study may conform that three deformation phase, NE first phase-NE second phase-NW phase, occurred in the area.

  • PDF

Features on the Vertical Size Distribution of Aerosols using Ballon-borne Optical Particle Counter at Anmyeon (광학입자계수기를 이용한 안면도 연직 에어러솔 수농도 크기 분포 특성)

  • Choi, B.C.;Iwasaka, Y.;Lim, J.C.;Jeong, S.B.;Kim, Y.S.;Dmitri, T.;Nagatani, T.;Yamada, M.;Kim, S.B.;Hong, G.M.;Lee, Y.G.;Yoo, H.J.
    • Atmosphere
    • /
    • v.15 no.3
    • /
    • pp.149-153
    • /
    • 2005
  • A balloon-borne Optical Particle Counter (hereafter "OPC Sonde"), which was developed by the atmospheric research group of Nagoya University, is used for getting the information of vertical profile of particle size and concentration in Anmyeon ($36^{\circ}32^{\prime}N$ $126^{\circ}19^{\prime}E$) on 18 March 2005. A range of five different particle sizes is shown in the vertical profile of aerosol number density estimated from the OPC Sonde. It was found that small size particles have vertically larger aerosol number density than relatively big ones. For all size ranges the vertical aerosol number density shows a decreased pattern as the altitude becomes higher. The aerosol number density of $0.3{\sim}0.5{\mu}m$, $0.5{\sim}0.8{\mu}m$, $0.8{\sim}1.2{\mu}m$ size ranges at the 10km height, which is the tropopause approximately, are $1,000,000ea/m^3$, $100,000ea/m^3$, $10,000ea/m^3$ respectively. The data of OPC Sonde are also compared with the data of PM10 $\beta$-ray) and Micro Pulse Lidar which are operating at Korea Global Atmosphere Watch Observatory in Anmyeon.

Design and Implementation of Integrated System for Microarray Data (마이크로어레이 실험 및 분석 데이터 처리를 위한 통합 관리 시스템의 설계와 구현)

  • 이미경;최정현;조환규
    • Microbiology and Biotechnology Letters
    • /
    • v.31 no.2
    • /
    • pp.182-190
    • /
    • 2003
  • As DNA microarrays are widely used recently, the amount of microarray data is exponentially increasing. Until now, however, no domestic system is available for the efficient management of such data. Because the number of experimental data in a specific laboratory is limited, it is necessary to avoid redundant experiments and to accumulate the results using a shared data management system for microarrays. In this paper, a system named WEMA (WEb management of Micro Arrays) was designed and implemented to manage and process the microarray data. WEMA system was designed to include the basic feature of MIAME (Minimal Information About a Microarray Experiment), and general data units were also defined in the system in order to systematically manage the data. The WEMA system has three main features: efficient management of microarray data, integration of input/ouput data, and metafile processing. The system was tested with actual microarray data produced by a molecular biology laboratory, and we found that the biologists could systematically manage and easily analyze the microarray data. As a consequence, the researchers could reduce the cost of data exchange and communication.

Micro to Nano-scale Electrohydrodynamic Nano-Inkjet Printing for Printed Electronics: Fundamentals and Solar Cell Applications

  • Byeon, Do-Yeong
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.3.2-3.2
    • /
    • 2011
  • In recent years, inkjet printing technology has received significant attention as a micro/nanofabrication technique for flexible printing of electronic circuits and solar cells, as well for biomaterial patterning. It eliminates the need for physical masks, causes fewer environment problems, lowers fabrication costs, and offers good layer-to-layer registration. To fulfill the requirements for use in the above applications, however, the inkjet system must meet certain criteria such as high frequency jetting, uniform droplet size, high density nozzle array, etc. Existing inkjet devices are either based on thermal bubbles or piezoelectric pumping; they have several drawbacks for flexible printing. For instance, thermal bubble jetting has limitations in terms of size and density of the nozzle array as well as the ejection frequency. Piezoelectric based devices suffer from poor pumping energy in addition to inadequate ejection frequency. Recently, an electrohydrodynamic (EHD) printing technique has been suggested and proposed as an alternative to thermal bubble or piezoelectric devices. In EHD jetting, a liquid (ink) is pumped through a nozzle and a strong electric field is applied between the nozzle and an extractor plate, which induce charges at the surfaces of the liquid meniscus. This electric field creates an electric stress that stretches the meniscus in the direction of the electric field. Once the electric field force is larger than the surface tension force, a liquid droplet is formed. An EHD inkjet head can produce droplets smaller than the size of the nozzle that produce them. Furthermore, the EHD nano-inkjet can eject high viscosity liquid through the nozzle forming tiny structures. These unique features distinguish EHD printing from conventional methods for sub-micron resolution printing. In this presentation, I will introduce the recent research results regarding the EHD nano-inkjet and the printing system, which has been applied to solar cell or thin film transistor applications.

  • PDF

Novel Low-Volume Solder-on-Pad Process for Fine Pitch Cu Pillar Bump Interconnection

  • Bae, Hyun-Cheol;Lee, Haksun;Eom, Yong-Sung;Choi, Kwang-Seong
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.2
    • /
    • pp.55-59
    • /
    • 2015
  • Novel low-volume solder-on-pad (SoP) process is proposed for a fine pitch Cu pillar bump interconnection. A novel solder bumping material (SBM) has been developed for the $60{\mu}m$ pitch SoP using screen printing process. SBM, which is composed of ternary Sn-3.0Ag-0.5Cu (SAC305) solder powder and a polymer resin, is a paste material to perform a fine-pitch SoP in place of the electroplating process. By optimizing the volumetric ratio of the resin, deoxidizing agent, and SAC305 solder powder; the oxide layers on the solder powder and Cu pads are successfully removed during the bumping process without additional treatment or equipment. The Si chip and substrate with daisy-chain pattern are fabricated to develop the fine pitch SoP process and evaluate the fine-pitch interconnection. The fabricated Si substrate has 6724 under bump metallization (UBM) with a $45{\mu}m$ diameter and $60{\mu}m$ pitch. The Si chip with Cu pillar bump is flip chip bonded with the SoP formed substrate using an underfill material with fluxing features. Using the fluxing underfill material is advantageous since it eliminates the flux cleaning process and capillary flow process of underfill. The optimized interconnection process has been validated by the electrical characterization of the daisy-chain pattern. This work is the first report on a successful operation of a fine-pitch SoP and micro bump interconnection using a screen printing process.

An Ultra-precision Lathe for Large-area Micro-structured Roll Molds (대면적 미세패턴 롤 금형 가공용 초정밀 롤 선반 개발)

  • Oh, Jeong Seok;Song, Chang Kyu;Hwang, Jooho;Shim, Jong Youp;Park, Chun Hong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.12
    • /
    • pp.1303-1312
    • /
    • 2013
  • We report an ultra-precision lathe designed to machine micron-scale features on a large-area roll mold. The lathe can machine rolls up to 600 mm in diameter and 2,500 mm in length. All axes use hydrostatic oil bearings to exploit the high-precision, stiffness, and damping characteristics. The headstock spindle and rotary tooling table are driven by frameless direct drive motors, while coreless linear motors are used for the two linear axes. Finite element method modeling reveals that the effects of structural deformation on the machining accuracy are less than $1{\mu}m$. The results of thermal testing show that the maximum temperature rise at the spindle outer surface is approximately $0.5^{\circ}C$. Finally, performance evaluations of the error motion, micro-positioning capability, and fine-pitch machining demonstrate that the lathe is capable of producing optical-quality surfaces with micron-scale patterns with feature sizes as small as $20{\mu}m$ on a large-area roll mold.

Hemodynamic Analysis of Blood Flows in the Extraembryonic Blood Vessels of Chicken Embryos (유정란 태아외부혈관 내부 혈액유동에 대한 혈류역학적 연구)

  • Lee, Jung-Yeop;Lee, Sang-Joon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.6-9
    • /
    • 2008
  • Analyzing the characteristics of blood flow in the blood vessels is very important to diagnose the circulatory diseases. In order to investigate the hemodynamic characteristics in vivo, the measurements of blood flows inside the extraembryonic arterial and venous blood vessels of chicken embryos were carried out using an in vivo micro-PIV technique. The circulatory diseases are closely related with the formation of abnormal hemodynamic shear stress regions, thereby it is important to get blood velocity and vessel's morphological information according to the vessel configuration and the flow conditions. In this study, the flow images of RBCs in blood vessels were obtained using a high-speed CMOS camera with a spatial resolution of approximately 14.6${\mu}$m${\times}$14.6${\mu}$m in the whole circulation network of blood vessels. The blood flows in the veins and arteries show steady laminar and unsteady pulsatile flow characteristics, respectively. The mean blood flows merged (in veins) and bifurcated (in arteries) smoothly into the main blood vessel and branches, respectively, without any flow separation or secondary flow which accompanying large variation of shear stress. Vorticity was high in the inner regions for both types of vessels, where the radius of curvature varied greatly. The instantaneous flows in the arterial blood vessels showed noticeable pulsatility due to the heart beat, and the main features of the velocity waveforms, including pulsatile shape, retrograde flow, mean velocity, maximum velocity and pulsatile frequency, were significantly dependent on the pulsatile condition which dominates the arterial blood flow. In near future, these in vivo experimental results of blood flow measured in various extraembryonic blood vessels would be very useful to understand the hemodynamic characteristics of human blood flows and various blood flow researches for clinically useful hemodynamic discoveries as well.

  • PDF

A Continuous Electrical Cell Lysis Chip using a DC Bias Voltage for Cell Disruption and Electroosmotic Flow (한 쌍의 전극으로 전기 삼투 유동과 세포 분쇄 기능을 동시에 구현한 연속적인 세포 분쇄기)

  • Lee, Dong-Woo;Cho, Young-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.10
    • /
    • pp.831-835
    • /
    • 2008
  • We present a continuous electrical cell lysis chip, using a DC bias voltage to generate the focused high electric field for cell lysis as well as the electroosmotic flow for cell transport. The previous cell lysis chips apply an AC voltage between micro-gap electrodes for cell lysis and use pumps or valves for cell transport. The present DC chip generates high electrical field by reducing the width of the channel between a DC electrode pair, while the previous AC chips reducing the gap between an AC electrode pair. The present chip performs continuous cell pumping without using additional flow source, while the previous chips need additional pumps or valves for the discontinuous cell loading and unloading in the lysis chambers. The experimental study features an orifice whose width and length is 20 times narrower and 175 times shorter than the width and length of a microchannel. With an operational voltage of 50 V, the present chip generates high electric field strength of 1.2 kV/cm at the orifice to disrupt cells with 100% lysis rate of Red Blood Cells and low electric field strength of 60 V/cm at the microchannel to generate an electroosmotic flow of $30{\mu}m/s{\pm}9{\mu}m/s$. In conclusion, the present chip is capable of continuous self-pumping cell lysis at a low voltage; thus, it is suitable for a sample pretreatment component of a micro total analysis system or lab-on-a-chip.