• Title/Summary/Keyword: Micro data center

Search Result 209, Processing Time 0.033 seconds

Efficient Operation and Management Scheme of Micro Data Centers for Realization of Edge Computing (에지 컴퓨팅의 실현을 위한 마이크로 데이터센터의 효율적인 운영 및 관리 기법)

  • Choi, JungYul
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.11
    • /
    • pp.30-39
    • /
    • 2020
  • As 5G mobile communication services are provided, efforts are being made to provide various services to users with ultra-low latency. This raises interest in edge computing, which can provide high performance computing services near users instead of cloud computing at the network core. This paper presents an efficient operation and management scheme of a micro data center, which is an essential equipment for realizing edge computing. First, we present the functional structure and deployment plan of edge computing. Next, we present the requirements for the micro data centers for edge computing and the operation and management scheme accordingly. Finally, in order to efficiently manage resources in the micro data centers, we present resource management items to be collected and monitored, and propose a performance indicator to measure the energy efficiency.

Improvement of Sensitivity to In-plane Strain/Deformation Measurement by Micro-ESPI Technique (마이크로 ESPI 기법에 의한 면내 변형 측정 민감도 향상)

  • Kim D.I.;Huh Y.H.;Kee C.D.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1442-1445
    • /
    • 2005
  • Several test methods, including micro strain/deformation measurement techniques, have been studied to more reliably measure the micro properties in micro/nano materials. Therefore, in this study, the continuous measurement of in-plane tensile strain in micro-sized specimens of thin film materials was introduced using the micro-ESPI technique. TiN and Au thin films 1 and $0.47\;\mu{m}$ thick, respectively, were deposited on the silicon wafer and fabricated into the micro-sized tensile specimens using the electromachining process. The micro-tensile loading system and micro-ESPI system were developed to measure the tensile strain during micro-tensile test. The micro-tensile stress-strain for these materials was determined using the algorithm for continuous strain measurement. Furthermore, algorithm for enhancing the sensitivity to measurement of in-plane tensile strain was suggested. According to the algorithm for enhancement of sensitivity, micro-tensile strain data between interfringe were calculated. It is shown that the algorithm for enhancement of the sensitivity suggested in this study makes the sensitivity to the in-plane tensile strain increase.

  • PDF

Filling Behavior of Polymer Melt in Micro Injection Molding for V-Grooves Pattern (V-Groove 패턴을 위한 마이크로 사출성형의 폴리머 멜트 충전 거동)

  • Kim, Moo Sun;Kim, Seung Mo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.3
    • /
    • pp.291-298
    • /
    • 2014
  • This study uses two numerical approaches to analyze the filling behavior of micro patterns on micro-injection molding for V-grooves pattern which cannot be simulated with conventional CAE packages. The parametric studies have been performed to examine the fidelity of micro patterns with respect to temperature, pressure, inlet velocity and pattern location on the mold according to the boundary condition from the macro pressure and velocity data which can be obtained by conventional CAE packages. Through these numerical approaches, the filling behavior of polymer melt in micro patterns can be understood, the quality of replication can be predicted, and the V-groove pattern can be shaped uniformly during the process of injection molding.

microRNA target prediction when negative data is not available for learning (학습을 위한 네거티브 데이터가 존재하지 않는 경우의 microRNA 타겟 예측 방법)

  • Rhee, Je-Keun;Kim, Soo-Jin;Zhang, Byoung-Tak
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06c
    • /
    • pp.212-216
    • /
    • 2008
  • 기존의 알려진 데이터에 기반하여 분류 알고리즘을 통해 새로운 생물학적인 사실을 예측하는 것은 생물학 연구에 매우 유용하다. 하지만 생물학 데이터 분류 문제에서 positive 데이터만 존재할 뿐, negative 데이터는 존재하지 않는 경우가 많다. 이와 같은 상황에서는 많은 경우에 임의로 negative data를 구성하여 사용하게 된다. 하지만, negative 데이터는 실제로 negative임이 보장된 것이 아니고, 임의로 생성된 데이터의 특성에 따라 분류 성능 및 모델의 특성에 많은 차이를 보일 수 있다. 따라서 본 논문에서는 단일 클래스 분류 알고리즘 중 하나인 support vector data description(SVDD) 방법을 이용하여 실제 microRNA target 예측 문제에서 positive 데이터만을 이용하여 학습하고 분류를 수행하였다. 이를 통해 일반적인 이진 분류 방법에 비해 이와 같은 방법이 실제 생물학 문제에 보다 적합하게 적용될 수 있음을 확인한다.

  • PDF

miR-195/miR-497 Regulate CD274 Expression of Immune Regulatory Ligands in Triple-Negative Breast Cancer

  • Yang, Lianzhou;Cai, Yuchen;Zhang, Dongsheng;Sun, Jian;Xu, Chenyu;Zhao, Wenli;Jiang, Wenqi;Pan, Chunhua
    • Journal of Breast Cancer
    • /
    • v.21 no.4
    • /
    • pp.371-381
    • /
    • 2018
  • Purpose: Immune suppression is common in patients with advanced breast cancer but the mechanisms underlying this phenomenon have not been sufficiently studied. In this study, we aimed to identify B7 family members that were able to predict the immune status of patients, and which may serve as potential targets for the treatment of breast cancer. We also aimed to identify microRNAs that may regulate the expression of B7 family members. Methods: The Cancer Genome Atlas data from 1,092 patients with breast cancer, including gene expression, microRNA expression and survival data, were used for statistical and survival analyses. Polymerase chain reaction and Western blot were used to measure messenger RNA and protein expression, respectively. Luciferase assay was used to investigate direct microRNA target. Results: Bioinformatic analysis predicted that microRNA (miR)-93, miR-195, miR-497, and miR-340 are potential regulators of the immune evasion of breast cancer cells, and that they exert this function by targeting CD274, PDCD1LG2, and NCR3LG1. We chose CD274 for further investigations. We found that miR-195, miR-497, and CD274 expression levels were inversely correlated in MDA-MB-231 cells, and miR-195 and miR-497 expressions mimic inhibited CD274 expression in vitro. Mechanistic investigations demonstrated that miR-195 and miR-497 directly target CD274 3' untranslated region. Conclusion: Our data indicated that the level of B7 family members can predict the prognosis of breast cancer patients, and miR-195/miR-497 regulate CD274 expression in triple negative breast cancer. This regulation may further influence tumor progression and the immune tolerance mechanism in breast cancer and may be able to predict the effect of immunotherapy on patients.

Measurement on Vibration Mode of Tire Wheel as a Energy Source of Micro Power (초소형 동력 에너지원으로서의 타이어 휠 진동 모드 측정)

  • Shin, You-Hwan;Lee, Yoon-Pyo
    • Journal of Hydrogen and New Energy
    • /
    • v.20 no.1
    • /
    • pp.64-72
    • /
    • 2009
  • In order to convert efficiently vibration energy of a car tire wheel into electrical power by using piezoelectric materials, the design of the materials must be performed for the dynamic characteristics of the piezoelectric materials to be matched with them of the vibration energy sources well. An accelerometer was installed on the tire wheel with a slip ring to investigate the dynamic mode of the wheel as one of the vibration energy sources. During road test, the measurement on the vibration mode of the tire wheel was performed with variations of car speed and road condition. The experimental data were analyzed details for availability as a micro power source for wireless TPMS(Tire Pressure Monitoring System).

Flight Test Measurement and Assessment of a Flapping Micro Air Vehicle

  • Kim, Jong-Heon;Park, Chan-Yik;Jun, Seung-Moon;Chung, Dae-Keun;Kim, Jong-Rok;Hwang, Hee-Chul;Stanford, Bret;Beran, Philip;Parker, Gregory;Mrozinski, Denny
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.2
    • /
    • pp.238-249
    • /
    • 2012
  • Flight test of flapping micro air vehicles (FMAVs) is carried out using an instrumented measurement system to obtain various engineering parameters and hence to assess the flight performance of the vehicles through the data investigation. An indoor flight test facility equipped with a motion capture system and tracking cameras is used for the work presented in this paper. Maneuvers including straight-level flight, ground flapping, takeoff and landing are tested. Spatial position and orientation data are obtained from the retro-reflective tracking markers attached to the vehicles. Subsequent test analysis is carried out by generating performance parameters from raw data and then assessing the flight performance by comparison of the vehicles. The main findings of this work confirm that the test method and procedures presented here enable the systematic numerical data measurement and assessment of the flying performances of these vehicles, and show the applicability for the test and evaluation of general flapping MAVs.

MOBILE FRAMEWORK FOR INTEGRATED 4S DATA

  • Oh, Byoung-Woo;Kim, Mi-Jeong;Lee, Eun-Kyu;Kim, Min-Soo
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.838-843
    • /
    • 2002
  • Recently, PDA and cellular phone with color LCD have been widely used in various fields by high efficiency and micro miniaturization technology. According to maturity of these mobile environments, user request about mobile application field is increased. Mobile applications provide various information which is concerned with user's position through cable and wireless transmission. This paper discusses the issues related to the mobile framework for integrated 4S data. The integrated 4S data mean spatial data fusion on GIS, SIIS, ITS, and GNSS. The mobile framework provides not only spatial data but also location services such as reverse geocoding, directory service, etc. It consists of client subsystem, service provider, and data provider.

  • PDF

Experimental Investigation on Flow Characteristics of Chicken Blood in a Micro Tube Using a Micro-PIV Technique (마이크로 PIV를 이용한 미세튜브 내부 조류 혈액유동에 관한 실험적 연구)

  • Yeo, Chang-Sub;Ji, Ho-Seong;Lee, Sang-Joon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.11 s.254
    • /
    • pp.1027-1034
    • /
    • 2006
  • In order to investigate flow characteristics of chicken blood in a micro tube of 100$\mu$m in diameter, in-vitro experiments were carried out using a micro-PIV technique. The micro-PIV system consists of a microscope, 2-head Nd:YAG laser, 12 bit cooled CCD camera and a delay generator. Chicken blood with 40% hematocrit was supplied into a micro tube using a syringe pump. The blood flow shows clearly the cell free layer near the tube wall and its thickness is increased with increasing the flow speed. The hemorheological characteristics of chicken blood, including shear rate and shear stress were estimated from the PIV velocity field data obtained. Since the aggregation index of chicken blood is less than 50% of human blood, non-Newtonian flow characteristics of chicken blood are smaller than those of human blood. As the flow rate increases, the degree of flatness in the velocity profile at the center region is decreased and the parabola-shaped shear stress distribution becomes to have a linear profile. Under the same flow rate, chicken blood shows higher shear stress, compared with human blood.

Application of White Light Interferometery Method for the Measurement of Surface Micro-structure of Paper Products and Prints (백색광 주사간섭법을 이용한 표면미세형상 측정과 그 적용)

  • Sung Yong Joo;Ryu Jeong Yong;Song Bong Keun
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.36 no.4 s.107
    • /
    • pp.33-40
    • /
    • 2004
  • A white light interferometery (WLI) method for investigating surface microstructure was introduced. Brief description of the principle of this method was provided. The surface structure of various samples, for example, a liner board paper, a pigment coated paper, a intaglio printed paper and a polymer laminated paper were tested and characterized with the WLI method. The data showed the WLI method provided very detailed information about surface topography, which were little affected by the surface condition such as color, opacity, roughness, etc. The data stitching mode of the WLI method could provide high spatial resolution over a large field-of-view, which made it possible to obtain the statistically valid results. Fast and high repeatability also made this method a promising way for investigating the surface micro-structure of paper products and prints.