• Title/Summary/Keyword: Micro controller unit

Search Result 120, Processing Time 0.025 seconds

A Wrist Watch-type Cardiovascular Monitoring System using Concurrent ECG and APW Measurement

  • Lee, Kwonjoon;Song, Kiseok;Roh, Taehwan;Yoo, Hoi-jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.702-712
    • /
    • 2016
  • A wrist watch type wearable cardiovascular monitoring device is proposed for continuous and convenient monitoring of the patient's cardiovascular system. For comprehensive monitoring of the patient's cardiovascular system, the concurrent electrocardiogram (ECG) and arterial pulse wave (APW) sensor front-end are fabricated in $0.18{\mu}m$ CMOS technology. The ECG sensor frontend achieves 84.6-dB CMRR and $2.3-{\mu}Vrms$-input referred noise with $30-{\mu}W$ power consumption. The APW sensor front-end achieves $3.2-V/{\Omega}$ sensitivity with accurate bio-impedance measurement lesser than 1% error, consuming only $984-{\mu}W$. The ECG and APW sensor front-end is combined with power management unit, micro controller unit (MCU), display and Bluetooth transceiver so that concurrently measured ECG and APW can be transmitted into smartphone, showing patient's cardiovascular state in real time. In order to verify operation of the cardiovascular monitoring system, cardiovascular indicator is extracted from the healthy volunteer. As a result, 5.74 m/second-pulse wave velocity (PWV), 79.1 beats/minute-heart rate (HR) and positive slope of b-d peak-accelerated arterial pulse wave (AAPW) are achieved, showing the volunteer's healthy cardiovascular state.

Analog-Digital Signal Processing System Based on TMS320F28377D (TMS320F28377D 기반 아날로그-디지털 신호 처리 시스템)

  • Kim, Hyoung-Woo;Nam, Ki Gon;Choi, Joon-Young
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.14 no.1
    • /
    • pp.33-41
    • /
    • 2019
  • We propose an embedded solution to design a high-speed and high-accuracy 16bit analog-digital signal processing interface for the control systems using various external analog signals. Choosing TMS320F28377D micro controller unit (MCU) featuring high-performance processing in the 32-bit floating point operation, low power consumption, and various I/O device supports, we design and build the proposed system that supports both 16-bit analog-digital converter (ADC) interface and high precision digital-analog converter (DAC) interface. The ADC receives voltage-level differential signals from fully differential amplifiers, and the DAC communicates with MCU through 50 MHz bandwidth high-fast serial peripheral interface (SPI). We port the boot loader and device drivers to the implemented board, and construct the firmware development environment for the application programming. The performance of the entire implemented system is demonstrated by analog-digital signal processing tests, and is verified by comparing the test results with those of existing similar systems.

Single-Phase Self-Excited Induction Generator with Static VAR Compensator Voltage Regulation for Simple and Low Cost Stand-Alone Renewable Energy Utilizations Part II : Simulation and Experimental Results

  • Ahmed, Tarek;Noro, Osamu;Soshin, Koji;Sato, Shinji;Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.1
    • /
    • pp.27-34
    • /
    • 2003
  • In this paper, the power conditioner composed of the stand-alone single-phase squirrel cage rotor type self-excited induction generator (SEIG) driven by prime movers such as a wind turbine and a micro gas turbine (MGT) is presented by using the steady-state circuit analysis based on the two nodal admittance approaches using the per-unit frequency in addition to a new state variable defined by the per-unit slip frequency along with its performance evaluations for the stand-alone energy utilizations. The stande-alone single-phase SEIG operating performances in unregulated voltage control loop are then evaluated on line under the conditions of the speed change transients of the prime mover and the stand-alone electrical passive load power variations with the simple theoretical analysis and the efficient computation processing procedures described in the part I of this paper. In addition, a feasuible PI controlled feedback closed-loop voltage regulation scheme of the stande-alone single-phase SEIG is designed on the basis of the static VAR compensate. (SVC) and discussed in experiment for the promising stand-alone power conditioner. The experimental operating performance results are illustrated and give good agreements with the simulation ones. The simulation and experimental results of the stand-alone single-phase SEIG with the simple SVC controller for its stabilized voltage regulation prove the practical effectiveness of the additional SVC control loop scheme including the PI controller with fast response characteristics and steady-sate performance improvements.

Implementation of Improved safety and reliability Embedded system using Backup and Restore of TMR Architecture (TMR 구조에서의 백업과 복원을 활용한 안정성 및 신뢰성 향상 임베디드 시스템 구현)

  • Park, Joo-Yul;Lee, Jun-Hwan;Kim, Hyo-Sang;Kim, Bong-Taek;Chung, Ki-Seok
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.188-194
    • /
    • 2011
  • The purpose of this paper is to explain the implementation method in order to enhance stability and reliability of embedded system. In this research, Texas Instrument (TI)'s TMS570 MCU(Micro Controller Unit) is used to satisfy the standard of stability that is IEC 61508. IEC 61508 suggest SIL(Safety Integrity Level) from 1 to 4 and TMS570 is satisfied SIL3. Also, TMS570 can provide several stability functions can be used in realtime system. To use such functions, this paper suggest the solution about the defect that can be used in realtime system. In basic way TMR(Triple Modular Redundancy) suggested in addition to explain about the way to improve safety and reliability. Also this paper will suggest the method that reinforce the stability of calculation by using multiplex voter and memory.

  • PDF

Model-based Optimal Control Algorithm for the Clamp Switch of Zero-Voltage Switching DC-DC Converter

  • Ahn, Minho;Park, Jin-Hyuk;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.323-333
    • /
    • 2017
  • This paper proposes a model-based optimal control algorithm for the clamp switch of a zero-voltage switching (ZVS) bidirectional DC-DC converter. The bidirectional DC-DC converter (BDC) can accomplish the ZVS operation using the clamp switch. The minimum current for the ZVS operation is maintained, and the inductor current is separated from the input and output voltages by the clamp switch in this topology. The clamp switch can decrease the inductor current ripple, switching loss, and conduction loss of the system. Therefore, the optimal control of the clamp switch is significant to improve the efficiency of the system. This paper proposes a model-based optimal control algorithm using phase shift in a micro-controller unit. The proposed control algorithm is demonstrated by the results of PSIM simulations and an experiment conducted in a 1-kW ZVS BDC system.

Development of drive and control circuit for direct LED BLU (직하형 LED BLU의 구동 및 제어회로에 관한 연구)

  • Cheon, Woo-Young;Song, Sang-Bin;Kim, Jin-Hong;Kim, Ji-Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.119-124
    • /
    • 2007
  • 24" LCD Monitor용 LED BLU를 개발하기 위하여 1.5W R,G,G,B가 하나의 PKG에 들어있는 LED를 이용하여 Direct type의 Back Light Unit을 개발하였다. 방열 및 휘도 균일도를 고려하여 LED part를 설계, 개발 하였고 LED를 pulse로 구동하기 위하여 Switching circuit이 포함되는 구동회로 부분을 설계, 개발하였다. 또한 Color Sensor와 ICM (Integrated Color Management) IC를 사용하여 Color를 Control하는 제어회로 부분도 개발을 하였다. 제어회로 부분을 개발하기 위하여 MicroController를 사용하였으며 ICM IC와의 통신을 위한 부분도 개발하였다. 이러한 구성을 개발하여 시제품을 직접 제작하였다. 평가를 위하여 성능시험을 실시하였고 광학적인 평가도 시행하였다. 제작된 시제품은 $L558{\times}W359{\times}H30$으로 하였다. 휘도는 목표휘도를 이루었으며 균일도는 85% 이상이 되었다.

  • PDF

Implementation of a Stand-alone Photovoltaic Pumping System with Maximum Power Point Tracking

  • Zhengming Zhao;Kunlun Chen;Liqiang Yuan
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.635-638
    • /
    • 2001
  • Photovoltaic (PV) pumping systems with maximum power point tracking (MPPT) technique aims at obtaining the highest possible power to the pump under various insolation and temperature, thus overcomes the mismatch between the photovoltaic panel and the pumping load. A simple method of tracking the maximum power points and forcing the system to operate close to these points is presented in this paper. The MC68HC908GP32 micro control unit (MCU) is employed to implement the proposed MPPT controller. Experimental results will also show the performances of the photovoltaic pumping system with the MPPT technique.

  • PDF

Automatic Control of the Combine(II) -Automatic Header Height Control of the Head-feed Combine- (콤바인의 자동제어(自動制御)에 관한 연구(硏究)(II) -자탈형(自脱型) 콤바인의 예취(刈取)높이제어(制御)-)

  • Chung, C.J.;Nam, Y.S.;Nam, S.I.
    • Journal of Biosystems Engineering
    • /
    • v.14 no.2
    • /
    • pp.85-93
    • /
    • 1989
  • This study was intended to develop the system which controls header height of combine automatically by means of sensing the difference between the header and the ground surface. A micro-computer was used for the controller. The sensing unit designed for the study was composed of potentiometer, oscillating link, and gage wheel. An electric-hydraulic circuit was driven by microcomputer to control header height of combine. Performance of the control system was tested by computer simulation, stationary operation of header, and traveling on the simulated ground.

  • PDF

Automatic Distribution System using a Micro Controller Unit (MCU를 이용한 자동 분류 시스템)

  • Kim, Tae-Hyoung;Lee, Chan-Jae;Kwon, Jae-Hyoung;Kim, Young-Seong;Kim, Yik-Hyoun;Tak, Bo-Mi;Soh, Dea-Wha
    • Journal of the Speleological Society of Korea
    • /
    • no.81
    • /
    • pp.35-41
    • /
    • 2007
  • According as the industry develops recently, the import and export freight amount is increasing sharply, but physical distribution processing equipment ability had achieved conveyance, surge and setup of physical distribution by human's labor ability. But, inefficiency is indicated in operation of product line and warehouse or physical distribution storage equipment because is ceilinged the processing physical distribution amount and the efficiency in physical distribution processing by these labor ability.

Exhaust Gas Analysis System (배출가스 검사시스템)

  • Kim, Gwan-Hyung;Oh, Am-Suk
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.544-545
    • /
    • 2015
  • 오늘날 자동차에서 배출되는 유해 가스로 인한 지구 온난화를 막기 위하여 많은 환경규제를 받고 있다. 때문에 대부분의 국가들은 출시되는 자동차나 운행 중인 자동차에 대하여 배출가스 검사를 의무적으로 실시하여 배출가스에 의한 대기오염을 줄일 수 있도록 법제화하고 있다. 본 논문에서는 "배출가스 검사/진단시스템" 개발에 대한 고찰을 통하여 배출가스, RPM, 소음을 측정할 수 있는 MCU(micro controller unit) 기반의 데이터 계측기에 대한 설계방안을 제시하고자 한다. 또한, MCU를 기반으로 배출가스(HC, CO, CO2 등) 데이터 확보를 위한 광학 필터처리 기술 및 신호처리 알고리즘을 검토하였다. 자동차의 RPM을 측정할 수 있는 알고리즘에 대한 검토와 배출가스 및 소음을 측정할 수 있는 알고리즘을 개발하여 RS-485, TCP/IP 기반으로 데이터를 전송할 수 있는 배출가스 검사시스템을 제시하고자 한다.

  • PDF