Implementation of Improved safety and reliability Embedded system using Backup and Restore of TMR Architecture

TMR 구조에서의 백업과 복원을 활용한 안정성 및 신뢰성 향상 임베디드 시스템 구현

  • 박주열 (한양대학교 일반대학원 전자컴퓨터통신공학과, 샬롬엔지니어링(주)) ;
  • 이준환 (샬롬엔지니어링(주)) ;
  • 김효상 (샬롬엔지니어링(주)) ;
  • 김봉택 (샬롬엔지니어링(주)) ;
  • 정기석 (한양대학교 정보통신대학)
  • Published : 2011.10.20

Abstract

The purpose of this paper is to explain the implementation method in order to enhance stability and reliability of embedded system. In this research, Texas Instrument (TI)'s TMS570 MCU(Micro Controller Unit) is used to satisfy the standard of stability that is IEC 61508. IEC 61508 suggest SIL(Safety Integrity Level) from 1 to 4 and TMS570 is satisfied SIL3. Also, TMS570 can provide several stability functions can be used in realtime system. To use such functions, this paper suggest the solution about the defect that can be used in realtime system. In basic way TMR(Triple Modular Redundancy) suggested in addition to explain about the way to improve safety and reliability. Also this paper will suggest the method that reinforce the stability of calculation by using multiplex voter and memory.

Keywords